Heat-treated Glass. GUARDIAN A Company of Vision PATTERNED GLASS HORTICULTURAL GLASS SUN PERFORMANCE GLASS VISION GLASS SILKSCREENED GLASS THIN GLASS



Similar documents
INFORMATION REGARDING GLASS TYPES AND PROPERTIES

Pyroguard Wired Glass

TECHNICAL BULLETIN TECHNICAL DESCRIPTION DESCRIPTION OVERVIEW PROGRAMS. Data Sheet. Pilkington Toughened Safety Glass

Spandrel Glass Types and Recommendations

2010 edition. Handbook of. Fire-Rated Glass. for schools

Handling, Inspecting, Fabricating & Glazing Pilkington Solar-E on Tinted Glass

Impact-Resistant Windows and Sliding Glass Doors

Light Architecture. Colors Sweden. Light

Window Glass Design 5 According to ASTM E 1300

Technical Information. What you need to know to BUILD WITH LIGHT

Roller Wave Distortion Definition, Causes and a Novel Approach to Accurate, On-line Measurement

Residential Windows, 3 rd edition Corrected index 1

SunGuard IS 20 Technical Information

Thermal Breakage Prediction

Design qualification and type approval of PV modules

Building Code Clarifications - 7. Fire Resistance

Standard Specification for Flat Glass 1

Zero Width Glass Cutting with CO 2 Laser

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

The BASA Guide to the ISO Classification of Sealants for Building Construction

Scottsdale, Arizona. Presentation by: Hermes Norero, P.E. President and CEO

NICKEL SULPHIDE INCLUSIONS

PYROSWISS VETROFLAM CONTRAFLAM

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction

Unbeatable energy efficient glass curtain wall system

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector

Lecture 9: Annealing and Tempering

To Help Keep Danger Out Bring 3M In

SOLAR WATER HEATER USER AND INSTALLATION MANUAL

Mechanical Properties and Fracture Analysis of Glass. David Dutt Chromaglass, Inc.

Comparative Analysis of Retrofit Window Film to Replacement with High Performance Windows

North American Stainless

iku windows the intelligent self cleaning window AUTOMATIC system

Classification of reaction to fire of glass products Recommendation from Glass for Europe

ENERGY SAVING WINDOW FILMS S LAR CONTROL

The Industry s Most Advanced Sun-Sensing, Adaptive-Tinting Technology For Dynamic Windows

JIS G3472 Electric Resistance Welded Carbon Steel Tubes for Automobile Structural Purposes

Photovoltaic Glass Solutions

easytouch Projected capacitive touch for industrial applications Version: July 2013

Standard Specification for Laminated Architectural Flat Glass 1

Test Report No. C829QPEN

Glass Technical Document

A concise guide to Safety Glasses, the different standards and the effects of light on the eye. Contents. Links. Year of publication: 2010

CHAPTER 24 GLASS AND GLAZING

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

RACKING AND ATTACHMENT CRITERIA FOR EFFECTIVE MEMBRANE ROOF SYSTEM INTEGRATION Public Version 1: July 9, 2012

CODE OF PRACTICE FOR USE OF GLASS IN BUILDINGS

ASTM A860/A860M-09 Standard Specification for Wrought High Strength. Ferritic Steel Butt Welding Fittings. 1. Scope :- 2. Reference Documents :-

Selecting Energy Efficient New Windows in Florida

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Double Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.

Types Name Description. Films Polyethylene 4 and 6 mil Regular UV. Rigid Plastics Fiberglass" Fiber reinforced. "Plexiglass" or equal

WITH LOW EMISSIVITY GLASS

Unit 6: EXTRUSION. Difficult to form metals like stainless steels, nickel based alloys and high temperature metals can also be extruded.

Tube Control Measurement, Sorting Modular System for Glass Tube

Glossary. Argon: An inert, nontoxic gas used in insulating glass units to reduce heat transfer.

Fire-Rated Glass and Glazing START

Window Thermal Performance Optimization in Governmental Emirati Housing Prototype in Abu Dhabi, UAE

Energy efficiency of windows in historic buildings

Architectural Testing

3M Products for Solar Energy. Designed for efficiency. Built to last.

North American Stainless

North American Stainless

3M Certified Platinum Partner

Fire Resistant Systems

SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames.

Understanding BS EN 771-3: Aggregate concrete masonry units

Data sheets Material characteristics 1.2/1

REPORT ON THE TESTING OF SEALED UNITS TO VERIFY THE IMPACT OF PRESSURE EQUALISATION ON INSULATION VALUES.

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

TIE-32: Thermal loads on optical glass

High performance. Architectural glazings utilise thin. low-emissivity coating. Coating technology

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Solid shape molding is not desired in injection molding due to following reasons.

Prefabricated building PVC vertical sliding window

Pilkington Activ. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.

Building Integrated Photovoltaic (BIPV)

SOLAR SOLUTIONS BONDED MOUNTING TECHNOLOGY. DURABLE BONDING OF PV MODULES TO MOUNTING SYSTEMS WITH Sikasil

ElastoFlake & ElastoTec

Attenuation: Bending Loss

THE COMPOSITE DISC - A NEW JOINT FOR HIGH POWER DRIVESHAFTS

Selecting Energy Efficient New Windows in Texas

ENERGY SMARTS: ENERGY EFFICIENT WINDOWS

EUROPEAN STANDARD DRAFT NORME EUROPÉENNE pren EUROPÄISCHE NORM October 2009

Development of High-Speed High-Precision Cooling Plate

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Rooflighting and Glazing

Prism Solar Installation Manual

Selecting Energy-Efficient Windows

For the modifications listed below, the Qualification Approval tests in IEC and IEC 61646, shall be used as a guideline by the assessor:

North American Stainless

EN Insulating glass units, intended to be used in buildings and construction works

WATERPROOF PHOTOVOLTAIC SYSTEM

SHIELD NATIONAL OFFICE MELBOURNE 2-4 Freight Drive, Somerton, VIC 3062 Ph:

Pilkington Reflite Handling and Processing Guidelines Solar Control

Cathode Ray Tube. Introduction. Functional principle

Torque motors. direct drive technology

SFxxx-S PID Test Report (Potential Induced Degradation) TUV Rheinland Japan. ARC Product Management Ver. 1

Transcription:

Heat-treated Heat-treated Glass Glass Heat-treated Glass Heat-treated Heat-treated Glass Glass REFLECTIVE GLASS LAMINATED GLASS TEMPERED GLASS FLOAT GLASS MIRRORS LOW-E GLASS SUNGUARD PATTERNED GLASS HORTICULTURAL GLASS SUN PERFORMANCE GLASS VISION GLASS SILKSCREENED GLASS THIN GLASS A Company of Vision

Ordinary float glass is one of the most durable building materials. The durability of float glass under normal conditions of exposure is excellent, but it s thermal resistance and mechanical strenght properties are limited. Where added resistance to wind load and thermal stress is required, Float Glass might need to be heattreated in order to increase its strength.

Guardian, one of the leading glass making Companies worldwide, offers two heattreated glass products for architectural as well as residential and automotive applications. One heat-treated glass product which is suitable where safety glazing requirements need to be respected is tempered glass. In areas where added resistance to wind load and thermal stress is required, the heat-strengthened glass shall be the product of choice. Process The heat-treatment process of ordinary Float Glass consists in heating the glass beyond its softening point (over 600 C) and then cooling it down rapidly. This cooling freezes the outer surfaces in their dilated mode while allowing the inner material to retract as temperature drops, thus creating compression strength on the outer layers and tension in the inner layer. Compression strengths in tempered glass are higher than in heatstrengthened glass. At Guardian, heat treatment is performed in horizontal furnaces, ensuring good surface properties with tight tolerances. However, the treatment process causes some optical distortion of the glass surface which is often referred to as roller-wave and warp. Such distortion is inherent to the process and can not be considered as a defect, provided it is in between the tolerance levels as laid down in the applicable standards.

Tempered Glass Tempered glass has been available to the architectural marketplace for more than 30 years and is surpassed in volume only by annealed glass. Guardian alone has produced millions of square metres of tempered glass for a wide variety of applications. Tempered glass has been used traditionally in commercial applications where wind, snow or thermal loads exceed the strengths capabilities of heat-strengthened glass and in situations where tempered glass is mandated as a safety glass meeting legal regulations. Characteristics Tempered glass offers higher mechanical and thermal strength than annealed or heat-strengthened glass, while retaining other normal properties. Tempered glass has approximately four times the mechanical and thermal strength of annealed glass of equal thickness. With the exception of strength and breakage characteristics, tempered glass retains the normal properties of annealed glass, including chemical resistance, hardness, expansion and deflection. Tempered glass has a breakage pattern of small particles, that are much safer than the large and sharp pieces resulting from a broken lite of annealed glass. It is therefore called safety glass. Applications Suitable where safety glazing is required. Emergency exits. Entry areas and store fronts, where required by building regulations. Extremely high wind loads. Important note With tempered glass, spontaneous breakage can occur occasionally resulting from inclusion of materials such as nickel sulfide. These inclusions are inherent to in the production process. When the window breaks, the tempered glass splinters into numerous pieces, which can fall out of the opening either wedged together or as individual pieces. Although the risk of spontaneous breakage is usually minimal, planners should take alternatives into consideration, where applicable. Guardian recommends heat-strengthened glass, for which such cases of spontaneous breakage are unknown. In areas, for which tempered glass is mandatory, Guardian performs additional heat soak tests on the tempered glass. When nickel sulfide inclusions are heated, their volume can increase. If this happens, small transverse forces can then lead to spontaneous breakage. Heat soaking accelerates this heat up and expansion process. The heat-soak test consists in heating the tempered glass at 290 C for 8 hours. If inclusions are present, breakage is far more apt to occur during heat soaking than later at the installation site. Nevertheless, heat soaking is not an absolute guarantee that tempered glass cannot break after it is installed. However, this process does significantly decrease the probability of spontaneous breakage resulting from nickel sulfide inclusions. Conformances BS 6206A: 1981 Kitemark Licence KM 10170 DIN 1249 Part 12 EN 12150 ASTM 1048-92 Availability Minimum dimensions: 152 x 382 mm Maximum dimensions: 2000 x 3650 mm Thickness: 3 to 12 mm Optional for clear - and Low-e tempered: Heat soak test Mandatory for solar control and reflective tempered: Heat soak test

Heatstrengthened Glass Generally Guardian s heat-strengthened glass is recommended for designing building facades. Its typical radial breaking properties also ensure a maximum safety standard, because the glass remains in the frame. Heat-strengthened glass has even higher quality surface characteristics as compared to tempered glass. Moreover, heat-strengthened glass eliminates the danger of occasional spontaneous breakage, as can occur with tempered glass as a result of nickel sulfide inclusions. Characteristics Heat-strengthened glass offers higher mechanical and thermal strength than annealed glass, while retaining other normal properties. Heat strengthened glass has approximately twice the mechanical and thermal strength of annealed glass of equal thickness. With the exception of strength and breakage characteristics, heat-strengthened glass retains the normal properties of annealed glass, including chemical resistance, hardness, expansion and deflection. Heat-strengthened glass normally has a breakage pattern of large pieces, similar to the breakage pattern of annealed glass. The exact nature of the break pattern depends on the intensity of the applied load, position of the break origin, the glass temperature and the related factors. Heat-strengthened glass is hardly prone to spontaneous breakage than tempered glass. Applications Suitable for use in spandrel and/or vision areas where added resistance to wind load and thermal stress is required. Laminated solariums. Laminated skylights. High wind load areas. Important note: Heat-strengthened glass does not meet the provisions of the BS6206A as a safety glass product. The use of heat-strengthened glass in entryways is prohibited. Availability Minimum dimensions: Maximum dimensions: Thickness 300 x 400 mm 2000 x 3650 mm 4 to 10 mm Physical effects - not to be classified as product faults: Iridescence: physical effect with heat treated glass resulting from the distribution of the internal stress. Perception of dark-coloured rings or stripes with polarized light and/or when observed through polarizing lenses is possible depending on the viewing angle. Interference: prism effect of insulating glass when light is reflected or transmitted, visible in the form of coloured stripes or rings (Newton s rings) on the surface of the glass. Conformances EN1863 ASTM C 1048-92