Plug and Socket Devices CES 63 A Series 8579



Similar documents
Plug and Socket Devices SolConeX 16 A Series 8570

Series 8146/5-V37 and Series 8150/5-V37

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Terminal Boxes Series 8146

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Linear Luminaire with LED Series EXLUX 6402/2

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Flameproof Audible Signal 115 db (A) Series YA90

Control and Distribution Boxes made of Stainless Steel Series 8150

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

A good connection. International approvals.

Control Stations Made of Polyester Resin Series 8146

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

7 Lighting Technology

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Technical Data. Dimensions

Technical Data. Dimensions

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

5SV Residual Current Protective Devices

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Electronic overload relay EF19 and EF45

Type: DILM32 10(24V50HZ) Article No.:

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Type: DILM50(230V50HZ,240V60HZ) Article No.:

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

9 Control Equipment. Control Button Series 8082

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Electronic overload relay EF65, EF96 and EF146

Bimetallic Overload Relay Specifications

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Inductive sensor NI10-M18-Y1X-H1141

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

R.C.C.B. s two-pole LEXIC

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Explosion proof enclosures

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Type: DILM9 10(24VDC) Article No.:

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Floodlight Range Installation Guide

Operating Instructions

PSR The compact range Description

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Solenoid Valve Island Type 3965

Electric Rotary Actuator - On/Off or programmable control actuator

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Manual motor starter MS116

Manual Motor Starter MS 116 up to 16 A Technical Data

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Three-phase monitoring relay CM-PFE

Technical Information RIA14

Inductive slot sensor

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Compact pressure switch Flameproof enclosure Ex d Model PCA

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

49 Series - Relay interface modules A. Features

8146/5 Series Breaker Panelboards

BETA Protecting SITOR Semiconductor Fuses

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

400 Series Buccaneer BUCCANEER POWER. bulgin

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Redundancy Module QUINT-DIODE/40

Instructions for Safe Use

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Cable Plug acc. to DIN EN , Form A

Software and Display instruments

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Power Supplies 3. SDN-P DIN Rail Series

ASSEMBLED SOCKET-COMBINATIONS

Technical data sheet TDS0070

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

48 SERIES Relay interface modules 10 A

Product and functional description

Safety detection solutions

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

HERZ-Thermal Actuators

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Feed-through terminal block - SSK 110 KER-EX

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

1756 ControlLogix Chassis Specifications

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Air damper actuators

RY2 miniature industrial relays

Technical Specifications

Transcription:

www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated pins, flexibly embedded > Optimal contact by means of self-cleaning laminated contacts > With an integrated auxiliary contact for control and signalling purposes > With motor switching capacity AC-3 acc. to IEC 60947-3 > IP66 in any application position 14507E00 The plug and socket devices of the Series SolConeX 8579 are 63 A versions. An important safety criterion is their reliable load disconnect switch with a highly visible position indication. Plugging in and unplugging is done easily and safely in 0-position. The plug and socket devices comply with IEC/EN 60309-1/-2 (CEE), IEC/EN 60079-0, IEC/EN 60079-1 and IEC/EN 60079-7. The ability to plug the Ex plugs into non-ex sockets is guaranteed. In contrast, operation of the Ex sockets using non-ex plugs is reliably prevented. ATEX / IECEx Zone 0 1 2 20 21 22 Installation in x x x x WebCode 8579A Installation Equipment /1

Selection Table Version No. of poles Voltage Colour Frequency h Metal Order number Weight code adapter [V] Hz kg CES 63 A Switch socket 01679E00 200... 250 blue 50 and 60 9 8579/31-409 7.800 380... 415 red 50 and 60 6 8579/31-406 7.800 440... 460 red 60 11 8579/31-411 7.800 480... 500 black 50 and 60 7 8579/31-407 7.800 600... 690 black 50 and 60 5 8579/31-405 7.800 120 / 208... 144 / 250 277 / 480... 288 / 500 250 / 440... 265 / 460 347 / 600... 400 / 690 For metal cable glands, versions with metal adapter blue 50 and 60 9 8579/31-509 7.800 red 50 and 60 6 8579/31-506 7.800 black 50 and 60 7 8579/31-507 7.800 red 60 11 8579/31-511 7.800 black 50 and 60 5 8579/31-505 7.800 380... 415 red 50 and 60 6 M32 x 1.5 8579/31-406-S008 7.800 380... 415 red 50 and 60 6 M40 x 1.5 8579/31-406-S001 7.800 380... 415 red 50 and 60 6 M50 x 1.5 8579/31-406-S002 7.800 CES 63 A Plug Note 01675E00 red 50 and 60 6 M32 x 1.5 8579/31-506-S008 7.800 red 50 and 60 6 M40 x 1.5 8579/31-506-S001 7.800 red 50 and 60 6 M50 x 1.5 8579/31-506-S002 7.800 For metal cable glands, versions with metal adapter and earth connection* 09191E00 09196E00 380... 415 red 50 and 60 6 M32 x 1.5 8579/31-406-S009 7.800 380... 415 red 50 and 60 6 M40 x 1.5 8579/31-406-S010 7.800 380... 415 red 50 and 60 6 M50 x 1.5 8579/31-406-S011 7.800 red 50 and 60 6 M32 x 1.5 8579/31-506-S009 7.800 red 50 and 60 6 M40 x 1.5 8579/31-506-S010 7.800 red 50 and 60 6 M50 x 1.5 8579/31-506-S011 7.800 200... 250 blue 50 and 60 9 8579/12-409 0.880 380... 415 red 50 and 60 6 8579/12-406 0.880 440... 460 red 60 11 8579/12-411 0.940 480... 500 black 50 and 60 7 8579/12-407 0.880 600... 690 black 50 and 60 5 8579/12-405 0.880 120 / 208... 144 / 250 250 / 440... 265 / 460 277 / 480... 288 / 500 347 / 600... 400 / 690 blue 50 and 60 9 8579/12-509 0.940 red 50 and 60 6 8579/12-506 0.940 red 60 11 8579/12-511 0.940 black 50 and 60 7 8579/12-507 0.940 black 50 and 60 5 8579/12-505 0.940 - Please order the additional auxiliary contacts separately, for the order number see chapter "Accessories and Spare Parts". - Switch sockets with Ex i auxiliary contacts available on request. * Earth connection outside on the enclosure 70 mm 2 /2 Installation Equipment

Explosion Protection Global (IECEx) Gas and dust IECEx PTB 06.0020 Ex d e IIC T6 Gb Ex d e IIC T5 Gb with intrinsically safe auxiliary contacts: Ex d e [ib Gb] IIC T6 Gb Ex d e [ib Gb] IIC T5 Gb Ex tb IIIC T60 C... T75 C Db Europe (ATEX) Gas and dust PTB 01 ATEX 1150 E II 2 G Ex d e IIC T6 Gb E II 2 G Ex d e IIC T5 Gb with intrinsically safe auxiliary contacts: E II 2 G Ex d e [ib Gb] IIC T6 Gb E II 2 G Ex d e [ib Gb] IIC T5 Gb E II 2 D Ex tb IIIC T60 C... T75 C Db Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), China (China-Ex), India (PESO), Canada (CSA), Kazakhstan (TR), Korea (KCs), Russia (TR), Serbia (SRPS), Ukraine (TR), USA (FM), Belarus (TR) Technical Data Electrical data Main contacts Rated operational voltage max. 690 V Rated insulation voltage max. 690 V Rated operational current 63 A ) 100 Hz, 50 A Switching capacity according to IEC/EN 60947-3: AC-3 DC-23 DC-1 690 V, 63 A 220 V, 63 A 3) 220 V, 63 A 3) 18.5 kw, 220 / 230 / 240 V 120 V, 63 A 120 V, 63 A 30 kw, 380 / 400 / 415 V 60 V, 63 A 60 V, 63 A 37 kw, 500 V 55 kw, 690 V Short-circuit protection With thermal protection Without thermal protection Auxiliary contacts Rated operational voltage 1 contact 2 contacts connected in series 3) 3 contacts connected in series 80 A gg 63 A gg 250 V AC for unequal potential 125 V DC 400 V AC, for equal potential of both contacts 500 V AC, when 1 NC + 1 NO and the same potential of both contacts is used max. 6 A Rated operational current Short-circuit protection 6 A, tripping characteristic gg acc. to IEC/EN 60269-1 Ambient conditions Ambient temperature see Explosion Protection data - 45 C on request (internal lubrication with silicone grease) Mechanical data Service life electrical 20,000 operating cycles Mechanical 100,000 operating cycles Version Socket 8579/31 Material Enclosure material glass-fibre reinforced polyester Switch handle polyacetate, can be locked in 0- and I-position Degree of protection IP66 acc. to IEC/EN 60529 Version Plug 8579/12 Degree of protection IP66 acc. to IEC/EN 60529 Enclosure material Polyamide Installation Equipment /3

Technical Data Mounting / Installation Main contacts Version Socket 8579/31 Connection cross-section max. 1 x 16... 50 mm 2, finely stranded / stranded; 2 x 16 mm 2 6 Nm Version Plug 8579/12 Connection cross-section 2,5... 16 mm 2 max. 2 Nm Auxiliary contacts Standard version Possible auxiliary contacts 8080/1-1: 1 NC contact + 1 NO contact in left installation slot NO contact ON delayed NO contact OFF leading (> 20 ms before opening of the main contacts) NC contacts synchronizing max. 2 auxiliary contact blocks of type 8080/1 (slow-action contacts) 8080/1-1: 1 NC contact / 1 NO contact NO contact ON delayed NO contact OFF advanced (> 20 ms before opening of the main contacts) NC contact synchronising 8080/1-3: 2 NC contacts 8080/1-4: 2 NO contacts only in the left installation slot, synchronising in the right installation slot synchronising in all installation slots Connection cross-section 1.5... 2.5 mm 2 (AWG 16... 14) solid / finely stranded 0.4 Nm Cable entries Cable gland 1 x M50 x 1.5, cable dia. range 23... 35 mm; max. 2 x M40 x 1.5 Stopping plug 1 x M25 x 1.5 Arrangement of contacts and terminal markings View from the front. The illustrations show the 6 h position. 09195E00 230 V = 6 h 3 P + 3 P + N + 02395E00 Accessories and Spare Parts Designation Figure Description Art. no. Weight Auxiliary contact, Series 8080/1 Protective cap 12446E00 kg 1 NC contact + 1 NO contact (8080/1-168351 0.026 2 NC contacts (8080/1-3) 168356 0.026 2 NO contacts (8080/1-4) 168353 0.026 The switching function of the auxiliary contact depends on the installation slot used. Left: delayed (ON), leading (OFF); Right: synchronising Left and right: synchronising protecs the plug pins from pollution 153261 0.100 Switch insert 05365E00 8544/1-31L 167239 2.200 Plastic cable gland 14441E00 8161/7-M25-1707 1 piece 7... 17 mm 2 229918 0.020 02055E00 8161/7-M50-3516 1 piece 16... 35 mm 2 229951 0.091 /4 Installation Equipment

Accessories and Spare Parts Designation Figure Description Art. no. Weight kg Stopping plug 8290/3-M25 x 1,5 1 pieces 143524 0.007 Ex i cover 04840E00 Ex i cover for auxiliary contacts for use in Ex i circuits 168855 0.008 Auxiliary contact key 12451E00 for removing the mounted auxiliary contact 201909 0.035 14151E00 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Type A B C D 8579/31-4.. (63 A, 3 P + ) 260 84.0 69.5 112 04508E00 04511E00 8579/31-... CES 63 A Switch socket 8579/12-... CES 63 A Plug We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Installation Equipment /5