Compact pressure switch Flameproof enclosure Ex d Model PCA

Similar documents
Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Bimetal thermometer Model 52, industrial series

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Pressure transmitter For general industrial applications Model A-10

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Terminal Boxes Series 8146

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Technical data sheet TDS0070

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Threaded resistance thermometer Model TR10-C, with protection tube

Differential Pressure Transmitter Model DPT-10

Bypass level indicator With magnetic display Model BNA

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Technical Data. Dimensions

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

B-Series Switches Pressure, Differential Pressure & Hydraulic

Explosion proof enclosures

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Flow switches Series AD/VH

Control and Distribution Boxes made of Stainless Steel Series 8150

B-Series Temperature Switches

Precision digital pressure gauge Model CPG1500

Series 8146/5-V37 and Series 8150/5-V37

Linear Luminaire with LED Series EXLUX 6402/2

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Plastic tube flowmeters Series PT/PS

Solenoid Valve Island Type 3965

Operating Instructions

Terminal Box. Specifications TNCN

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

4/2-Way Pneumatic Solenoid Valve

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Control- and feedback head for integrated mounting on Robolux valves Type 2036

TEIP11 I/P signal converter for standard signals. Measurement made easy

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Safety instructions VEGADIS DIS81.CEIA/V****

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

SITRANS F flowmeters SITRANS F M

2.12. page Products for Explosion hazardous Environment

Solenoid valves 2/2-way direct-operated Type EV210A

Worcester DS/DM Series UltraSwitch Switch box

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Rosemount 751 Field Signal Indicator

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

Technical Specifications

Flameproof Audible Signal 115 db (A) Series YA90

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Hand-held thermometer Model CTH7000

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Digital inductive conductivity transmitter

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Aluminium Standard. Technical Data. Included in delivery

Scraper Passage Indicator. Electrical Indicator. Features

Operating Instructions

Operating Instructions

Inductive sensor NI10-M18-Y1X-H1141

Technical Information RIA14

Assisted lift operated 2/2-way solenoid valves Type EV250B

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

8146/5 Series Breaker Panelboards

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

Technical Data. Dimensions

Plug and Socket Devices CES 63 A Series 8579

SQUARE D INDUSTRIAL CONTROL PRODUCTS

OPTIMASS 6000 Technical Datasheet

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Solenoid valves Type EVU

Floodlight Range Installation Guide

Instruction Manual Differential Pressure Transmitter

distributing & controlling system solutions

Inductive slot sensor

ISO/VDMA Actuators. Engineering GREAT Solutions

Rosemount DIN-Style Temperature Sensors and Thermowells (Metric)

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

Relative pressure transmitter type 520

Micro Motion 3098 Gas Specific Gravity Meter

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Fluxi 2000/TZ Turbine Gas Meter

Instructions for Safe Use

SEISMIC VELOCITY TRANSDUCER T1-40

4 Posiflow Proportional Solenoid Valves

STB Series Enclosures

Micro Motion Model D and DL Coriolis Flow and Density Meters

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

How To Use A Flowmeter

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Electric Rotary Actuator - On/Off or programmable control actuator

Solenoid Valve Type 3962

2/2 and 3/2 Solenoid Control Valves

A good connection. International approvals.

API Flanged Safety Relief Valves Series 526 CATALOG

Proportional pressure regulators VPPE

Transcription:

Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring and control of processes Safety-critical applications in general process instrumentation, especially in the chemical and petrochemical industries, oil and gas industries, power generation incl. nuclear power plants, water/wastewater industries, mining For gaseous and liquid, aggressive, highly viscous or contaminated media, also in aggressive ambience For measuring points with limited space, e.g. control panels Special features No power supply needed for switching of electrical loads Robust switch enclosure from aluminium alloy or stainless steel, IP 66, NEMA 4X Setting ranges from 0.2... 1.2 to 200... 1,000 bar, vacuum ranges Repeatability of the set point 1% of span 1 set point, SPDT or DPDT, high switching power up to AC 250 V, 15 A Fig. left: Switch enclosure aluminium alloy Fig. right: Switch enclosure stainless steel Description The pressure switches have been developed especially for safety-critical applications with limited space. The high quality of the products and manufacturing in accordance with ISO 9001 ensure reliable monitoring of your plant. In production, the switches are traced by quality assurance software at every step and subsequently are 100 % tested. All wetted parts are from stainless steel as a standard. The switch enclosure is available in aluminium alloy or stainless steel. To adjust the set point simply open the access cover plate. This access can be sealed as an option. The access to the terminal block for the electrical connection is protected by a screw-on lid, which is secured with a screwtype lock against unauthorised intervention. The pressure switches are fitted with one micro switch, which enables the switching of an electrical load of up to AC 250 V, 15 A directly. For lower switching power ratings, such as for PLC applications, argon gas-filled micro switches with gold-plated contacts can be selected as an option. For two separate circuits the switches are also available in the version DPDT (double pole double throw). By using a diaphragm with antagonist spring as measuring element, the model PCA pressure switch is extremely robust and guarantees optimal operating characteristics. For medium and high setting ranges starting at 3 25 bar, a piston replaces or completes the diaphragm as a measuring element. The piston measuring element is designed for the specific requirements of liquid media. WIKA data sheet PV 33.31 11/2015 Page 1 of 5 Data sheets showing similar products: Pressure switch, ignition protection type Ex ia; model PCS; see data sheet PV 33.30

Standard version Switch enclosure Aluminium alloy, copper-free, epoxy resin coated Stainless steel 316L Tamper-proof. Laser-engraved product label from stainless steel. Ignition protection type Ex d I Mb (mines), only available with stainless steel switch enclosure Ex d IIC T6/T4 1) Ga/Gb (gas) Ex ta/tb IIIC T85/T135 1) Da/Db (dust) 1) The temperature class is related to the ambient temperature range. See the type examination certificate for further details. Ingress protection IP 66 per EN 60529 / lec 60529, NEMA 4X Permissible temperature Ambient T amb : -40... +85 C Medium T M : See table on next page. Depending on measuring element. Switch contact Micro switches with fixed dead band. 1 x SPDT (single pole double throw) 1 x DPDT (double pole double throw) The DPDT function is realised with 2 simultaneously triggering SPDT micro switches within 2 % of the span. Contact version Electrical rating (resistive load) AC DC A 1 x SPDT, silver 250 V, 15 A 24 V, 2 A, 125 V, 0.5 A, 220 V, 0.25 A B 1 x SPDT, silver, hermetically sealed, argon gas filling 1) 250 V, 15 A 24 V, 2 A, 220 V, 0.5 A C 1 x SPDT, gold-plated, hermetically sealed, argon gas filling 1) 125 V, 1 A 24 V, 0.5 A G 1 x DPDT, silver 250 V, 5 A 24 V, 0.5 A H 1 x DPDT, silver, hermetically sealed, argon gas filling 1) 250 V, 5 A 24 V, 0.5 A 1) Permissible ambient temperature range: -30... +70 C Set point adjustment The set point can be specified by the customer or factory set within the setting range. Subsequent adjustment of the set point on site is made using the adjustment bushing, which is covered by the access cover plate with lead seal option. Repeatability of the set point 1 % of span Please specify: Set point, switching direction for the contact, e.g. : Set point: 5 bar, increasing After unscrewing the access cover plate, set point adjustment can be made using the adjustment bushing. The set point is selectable within the entire setting range. For optimal performance we suggest to adjust the set point between 25... 75 % of the setting range. Example: Setting range: 1.6... 10 bar with one switch contact Repeatability: 1 % of 10 bar = 100 mbar Dead band = 200 mbar (see table setting ranges) Rising pressure: Adjust set point between 2.0... 10 bar. Falling pressure: Adjust set point between 1.6... 9.6 bar. Process connection Stainless steel 316L, lower mount (LM) ¼ NPT female (standard) ½ NPT, G ½ A, G ¼ A male via adapter ½ NPT, G ¼ female via adapter M20 x 1.5 male via adapter Electrical connection ½ NPT female (standard) ¾ NPT female M20 x 1.5 female Cable gland non-armoured Ex d, nickel-plated brass Cable gland non-armoured Ex d, AISI 304 Cable gland armoured Ex d, nickel-plated brass Cable gland armoured Ex d, AISI 304 For cable connections to the internal terminal block use wire cross-sections between 0.5... 1.5 mm 2. For the grounding cable connection to the protective conductor screws use max. 2.5 mm 2 for the internal screw and max. 4 mm 2 for the external screw. Dielectric strength Safety class I (IEC 61298-2: 2008) Page 2 of 5 WIKA data sheet PV 33.31 11/2015

Measuring element Measuring element Wetted parts Permissible medium temperature V Diaphragm with antagonist spring NBR -30... +110 C T Diaphragm with antagonist spring PTFE -30... +110 C M Diaphragm with antagonist spring Inconel, O-ring FPM -30... +200 C P Piston with antagonist spring 1) Stainless steel 316, O-ring FPM 0... 200 C G Piston with antagonist spring and welded diaphragm Hastelloy C276-40... +140 C 1) Particularly suited for liquid media. Setting range Setting range Measuring element Working range Proof pressure Dead band for contact version in bar in bar in bar A, B, C in bar G in bar H in bar -1... -0.2 V -1... 6 10 0.03 0.06 0.12 0.1... 2.5 M -1... 30 40 0.05 0.1 0.4 0.2... 1.2 T 0... 6 10 0.03 0.06 0.12 0.5... 2.5 M -1... 10 40 0.05 0.1 0.4 0.8... 6 M -1... 10 40 0.06 0.2 0.8 1.6... 10 M -1... 25 40 0.2 0.4 1.06 3... 25 P, G 0... 250 400 2 4 16 3.5... 70 P, G 0... 140 500 7 7 21 4... 25 M -1... 25 60 0.25 0.75 3 8... 40 P, G 0... 100 400 2 4 16 10... 40 M -1... 60 100 1 2 8 16... 100 P, G 0... 250 400 5 5 20 20... 100 M 0... 100 150 7 9 20 20... 220 P, G 0... 350 500 8 15 24 40... 250 P, G 0... 400 600 12 20 80 60... 250 P, G 0... 400 600 5... 12 to 12... 20 2) - - 80... 400 P, G 0... 600 600 20 20 80 100... 600 P, G 0... 600 700 30 30 120 100... 700 P 0... 700 1,050 30... 100 2) 200... 1,000 P 0... 1,000 1,500 40... 110 2) 2) The dead band depends on the set point adjustment. The indicated ranges are valid for start and end of the setting range. Other setting ranges are proportional. Mounting Direct or wall mounting Option: Mounting bracket for 2" pipe mounting Weight 1.0 kg, switch enclosure aluminium alloy 1.5 kg, switch enclosure stainless steel For mounting positions see drawing on page 5. Options Cleaned for oxygen service Drying of wetted parts Measuring element piston with O-ring NBR (permissible medium temperature: -10... +110 C) Permissible ambient temperature to -60 C 3) Offshore version with increased corrosion protection 4) NACE compliant to MR 0175, ISO 15156 and MR 0103 4) 3) only available for silver contacts without hermetic sealing and with measuring element M (see table on next page) 4) WIKA recommends argon gas-filled contact versions WIKA data sheet PV 33.31 11/2015 Page 3 of 5

Assembly (Option) Shut-off valve model 910.11, see data sheet AC 09.02 Barstock valve model 910.81, see data sheet AC 09.18 Diaphragm seals, see website Approvals Logo Description Country EC declaration of conformity Pressure equipment directive 97/23/EC PED, annex 1, category IV, safety accessories, module B + D Low voltage directive 2006/95/EC, EN 60730-1 European Community ATEX 1) directive 94/9/EC; annex III, IV I M 2 (only available with stainless steel 316L switch enclosure) II 1/2 GD II 2 GD (only with measuring element P ) IECEx 1) per IEC 60079-0, IEC 60079-1, IEC 60079-26, IEC 60079-31 Ex d I Mb (only available with stainless steel 316L switch enclosure) Ex d IIC T6/T4 2) Ga/Gb (gas), Ex ta/tb IIIC T85/T135 2) Da/Db (dust) Ex d IIC T6/T4 2) Gb, Ex tb IIIC T85/T135 2) Db (only with measuring element P ) IECEx member states EAC (option) Hazardous areas (option) INMETRO (option) Hazardous areas (option) KOSHA (option) Hazardous areas Eurasian Economic Community Brazil South Korea 1) Double marking ATEX and IECEx on the same product label. 2) The temperature class is related to the ambient temperature range. See the type examination certification for further details. Manufacturer s information and certifications Logo Description SIL 2 rating (option), per IEC 61508 Functional safety The electrical rating for DC applications is limited to 30 V... 100 ma Certificates (option) 2.2 test report per EN 10204 3.1 inspection certificate per EN 10204 Approvals and certificates, see website Page 4 of 5 WIKA data sheet PV 33.31 11/2015

Dimensions in mm Aluminium alloy Stainless steel B B ME = M, T = 28 ME = V = 25 A ME = M, T = 23 ME = V = 25 A ME = P 39 ME = G 59 SW 36 ME = P 35 WIKA data sheet PV 33.31 11/2015 Page 5 of 5 11/2015 EN ME = G 55 SW 36 Legend Ground screw, outside Adjustment bushing Terminal block Ground screw, inside Set point adjustment rod Calibration scale A Process connection Access cover plate B Electrical connection SW Spanner width ME Measuring Element, see table on page 3 Permissible mounting positions Aluminium alloy Stainless steel Ordering information Model / Unit / Setting range of set point / Contact version / Process connection / Electrical connection / Wetted parts / Options 2009 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de