EVALUATION ACCORDING TO ASTM F

Similar documents
100 Year Service Life of Polypropylene And Polyethylene Gravity Sewer Pipes. Summary Technical Report

Sarah Chung, Ken Oliphant, Patrick Vibien and Jingguo Zhang Jana Laboratories Inc., Aurora, Ontario, Canada

R-Value and Thermal Conductivity of PEX and PE-RT TR-48/2014

PEX Pipes for Plumbing Applications

PEX Pipes for Service Line Applications

Polyethylene Piping Distribution Systems for Components of Liquid Petroleum Gases TR-22

KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET

Engineering Specifications

ASTM D 1599 Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings

Worldwide tank building applications using PP-Sheets: The effect of Foaming on properties

BUMAX. REYHER your partner for the BUMAX range

More inside :: Tackle even the toughest water treatment piping challenges with

HDPE Physical Properties. HDPE_physical-properties_v002 Copyright Marley Pipe Systems (Pty) Ltd 2010

Standard Specifications, Standard Test Methods and Codes for PE (Polyethylene) Piping Systems

OUTLINE. How PEX pipes are made Capabilities of PEX pipes, standards, testing PEX pipes for Plumbing and other applications

General Guidelines for Butt, Saddle, and Socket Fusion of Unlike Polyethylene Pipes and Fittings TN-13/2007

Series Pressure/Pipe Testing Systems. Continuous and Short-Term Hydrostatic Pressure Testing per ASTM D1598 and D1599

Tubing Data. Contents. Tubing Selection. Tubing Handling. Tubing Material. Tubing Outside Diameter Hardness. Tubing Wall Thickness

PMS Reflex Blue C Mining PMS 8401C

Piping Systems. From design to your turnkey partner


INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Stress Strain Relationships

Environmental Stress Crack Resistance of Polyethylene Pipe Materials

Overheating limit control

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Torsion Tests. Subjects of interest

How To Use A Flowmeter

PENETRATION OF BITUMINOUS MATERIALS

TRENCHLESS TECHNOLOGY GUIDELINES CLOSE FIT THERMOPLASTIC LINING

Royal Seal Gasketed Sewer Pipe

TEST REPORT. Rendered to: DEXERDRY. For: Deck Weatherproofing System Installed with AZEK Deck Boards

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

Polyolefin Heat Shrink Tubing for Tight-Tolerance Medical Applications

FIBERGLASS REINFORCED PLASTIC (FRP) PIPING SYSTEMS DESIGNING PROCESS / FACILITIES PIPING SYSTEMS WITH FRP

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Trade Standard of Town Construction in PRC

PERFORMANCE TEST REPORT. Rendered to: FORMTECH ENTERPRISES, INC. SERIES/MODEL: Truline PRODUCT TYPE: PVC Seawall

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

CH 6: Fatigue Failure Resulting from Variable Loading

MANUFACTURER'S CERTIFICATION SCHEDULE 40 PVC PIPE And SCHEDULE 80 PVC PIPE

sealed close coupled pumps

Series 4000 Fiberglass Pipe and Fittings

GENERAL PROPERTIES //////////////////////////////////////////////////////

Gx Tubing. High-quality Gx Glass Tubing for pharmaceutical packaging. Tubular Glass

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seamless stainless tubes for hydraulic and instrumentation systems

Africa s leading steel supplier CATALOGUE TUBE & PIPE. The Macsteel Group - Africa s leading steel supplier -

Injection molding equipment

Green Thread Product Data

Flowtite Jacking Pipe

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

Best Available Technology for Sodium Hypochlorite Storage Tanks

EXPERIMENTAL ANALYSIS OF HEAT TRANSFER ENHANCEMENT IN A CIRCULAR TUBE WITH DIFFERENT TWIST RATIO OF TWISTED TAPE INSERTS

Material data sheet. EOS StainlessSteel GP1 for EOSINT M 270. Description, application

B05: Cable protection and sheathing

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

Innovation and Progress in Water Treatment Technology

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

The Mechanical Properties of Glass

ElastoFlake & ElastoTec

Plastic tubing, standard O.D.

Industrial Piping Systems

HOSTAFORM C 9021 POM Unfilled

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

SECTION POLYVINYL CHLORIDE (PVC) PIPE

Metal Pressfitting Pipe Systems

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

MICROCABLES. A complete vision of your connectivity needs. Catalogue

Bypass level indicator With magnetic display Model BNA

3D Printed Injection Molding Tool ("PIMT") Guide. Objet Ltd.

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

Company and Product Presentation

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES OUTCOME 2 ENGINEERING COMPONENTS TUTORIAL 1 STRUCTURAL MEMBERS

SIGRAFLEX . Properties. Applications

PP MASTERTM S T I F F N E S S S N 1 2 R I N G THE NEW POLYPROPYLENE SEWER PIPE SYSTEM

DIN STEEL PIPES FOR PIPE LINES FOR THE TRANSPORT OF COMBUSTIBLE FLUIDS AND GASES

TENSILE TESTING PRACTICAL

TABLE OF CONTENTS CHAPTER NO. TITLE PAGE NO. ABSTRACT

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

HDA

ISO INTERNATIONAL STANDARD

Tremco Fire Protection Systems Group Technical Bulletin

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Puddle Flange. FRANK Puddle Flange

Long term performance of polymers

Typical Aluminum GFM Mass Flow Meter

Tensile Testing Laboratory

VeMet, Utrecht, NL «Solution in Wear Protection» Dipl.-Ing. Wolfgang Leichnitz. Quit

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

PRODUCT / APPLICATION INFORMATION

JIS G3472 Electric Resistance Welded Carbon Steel Tubes for Automobile Structural Purposes

TECHNICAL SPECIFICATION

Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing

SITRANS F flowmeters SITRANS F M

Effect of Temperature and Aging Time on 2024 Aluminum Behavior

Experimental assessment of concrete damage due to exposure to high temperature and efficacy of the repair system

Digital inductive conductivity transmitter

Transcription:

Bodycote Report EVALUATION ACCORDING TO ASTM F 2023 Evaluation of the chlorine resistance according to ASTM F 2023 of the PB pipe material PB4267 GREY Mattias Svedberg RESTRICTED DISTRIBUTION

SE-611 82 Nyköping,Sweden P-8129 Phone +46 155 22 14 76 Fax +46 155 26 31 25 E-mail info@bodycotepolymer.com Basell Polyolefine GmbH Handled by: Industriepark Höchst, D 536 Mattias Svedberg 65926 Frankfurt (M) Germany Tech contact: Dr. Klaus Könnecke EVALUATION ACCORDING TO ASTM F 2023 Evaluation of the chlorine resistance according to ASTM F 2023 of the PB pipe material PB4267 GREY Abstract Basell Polyolefine GmbH has initiated a test program in order to evaluate the chlorine resistance of PB pipe material PB4267 GREY according to ASTM F 2023. 12 pipe specimens have been started at 95, 105 and 115 C. The chlorine level was set to 4 ppm and the ph level to 6.8. Calculations of the estimated time-to-failure according to ASTM F 2023 have been performed. The table below shows the estimated times to failure for the condition called Traditional Domestic (Cl-TD) and Domestic Continuous Re-circulation (Cl-R). Condition Temperature Hoop stress Service time fraction Traditional domestic 23 C (73 F) 2.20 MPa 75% (Cl-TD) 60 C (140 F) 2.20 MPa 25% Estimated time to failure 253 years Domestic Continuous Re-circulation (Cl-R) 60 C (140 F) 2.20 MPa 100% 65 years All estimations in this report are only valid for the investigated PB pipe material PB4267 GREY with the Bodycote code 3527. 1/16

LIST OF CONTENTS 1 Aim of the project 3 1.1 Summary of the ASTM F2023 test method 3 1.2 Bodycote Polymer approach 3 1.3 Failure types 3 2 Investigated pipe material 4 3 Experimental procedure 5 3.1 Chlorine circulation loop 5 4 Extrapolation techniques 6 4.1 Multiple linear regression 6 4.2 Miner s rule 6 5 Results from the chlorine circulation loop testing 7 5.1 Testing at 95 C 7 5.2 Testing at 105 C 7 5.3 Testing at 115 C 7 6 Evaluation according to ASTM F2023 8 6.1 Extrapolation hoop stress 8 6.2 Multiple linear regression analysis 9 6.3 Lifetime calculations 9 7 Additional comments 9 8 Referred documents 10 Appendices A B C D Client info Investigated pipe material and pressure testing tables Stress rupture diagram Multiple linear regression diagram Report written by Mattias Svedberg Operations Manager Reviewed by Approved by Joakim Jansson Project Manager 2/16 Jarno Hassinen Technical Manager

1 Aim of the project The aim of this project was to evaluate the effect of chlorinated water on the lifetime of PB pipe material PB4267 GREY delivered by Basell. The method of approach has been ASTM F 2023. 1.1 Summary of the ASTM F 2023 test method 1 The PEX tubing or tubing/fitting assemblies are exposed to pressurized test-fluid until failure. All time-to-fail data used for analysis shall be the result of oxidative degradation (Stage III). A minimum number of test temperature and hoop stress conditions are required to allow accurate data analysis and time-to-failure extrapolations. NOTE 2 The procedures described in this test method (with some modifications of test temperatures or stresses, or both) have been used to evaluate pipes manufactured from polybutylene (PB), polyethylene (PE), polypropylene (PP), multilayer (polymer-metal composite), copper, and stainless steel. 1.2 Bodycote Polymer approach Bodycote Polymer applies the ASTM F 2023 as follows; the tubing is tested at three temperatures (95, 105 and 115 C) and at two different pressure levels at each temperature with the aim to only generate Stage III failures. If a failure occurs that cannot be classified as Stage III, pipes will be started at a lower pressure level in order to allow accurate data analysis. When an accurate data set has been achieved, it is analyzed using ISO 9080, 3- and 4-parameter models. The model with the best fit is then used for the time-to-failure extrapolations applying the given service conditions in ASTM F 2023. 1.3 Failure types ASTM F 2023 requires that all data used for analysis shall be the result of environmental or oxidative degradation (Stage III). This report refers to Stage III failures as brittle failures. 1 Recitation from ASTM F 2023 3/16

2 Investigated pipe material Basell delivered the 16 mm SDR 2 9 PB pipe material, PB4267 GREY. All pipes show good visual appearance. The results obtained regarding the dimensions are shown in Table 1. All pipes showed small variations in the specific dimensions. Further information about the material is presented in Appendix B. Table 1 Dimension measurements results Code Outer diameter Min wall thickness Max wall thickness Mean 3 s 4 Mean s Mean s mm mm mm mm mm mm 3527 16.12 0.01 1.84 0.01 2.02 0.01 2 Standard Dimension Ratio 3 Mean value 4 Standard deviation value 4/16

3 Experimental procedure All tests have been performed at Bodycote Polymer, Sweden, and in accordance with ASTM F 2023. 3.1 Chlorine circulation loop The components in the circulation loop are made of inert materials such as titanium, PVDF and PTFE. In the chlorine dosage unit, PE, PVC and PP components have been used. The fittings are made from PFA. The chlorine is produced using sodium hypochlorite at a known ph. The test fluid is continuously purified after sample exposure through a state of the art filtering system including Reverse Osmosis (RO) to avoid contamination of the test fluid. The pipes have been tested in series (vertically), i.e. the pipe ends are unrestrained and allowed to freely expand bi-directionally. Table 2 Property Accuracy of temperature and pressure Temperature accuracy, inside Temperature accuracy, outside Pressure accuracy Value ±1 C ±2.5 C ±0.2 bar Table 3 Measured test parameters Property Set value Average s 5 ph 6.8 6.83 0.08 Chlorine level (inlet) 4.0 ppm 3.97 ppm 0.08 ppm ORP 6 825 mv 878 mv 15 mv Volume flow 54 dm 3 /h 7 - - 5 Standard deviation 6 Oxidation reduction potential 7 Corresponds to 0.13 m/s for a 1/2 SDR 9 pipe 5/16

4 Extrapolation techniques To predict the lifetime under constant conditions is multiple linear regression according to ISO 9080 used (conditions I-III) 8. When the pipes are exposed to different operational conditions the multiple regression analysis is combined with Miner s rule (condition IV). 4.1 Multiple linear regression The multiple linear regression method used for the determination of the time to failure (t fi ) is based on ISO 9080. The 4-parameter model contains four regression coefficients C 1 -C 4 and two independent variables, temperature (T i ) and stress (σ i ). For the 3-parameter model is C 3 =0. Equation 1 The 4-parameter model according to ISO 9080 Log ( t ) C + C + C Log( σ ) fi 1 = 1 2 3 i + C 4 Ti Log T ( σ ) Equation 1 can be used for calculations of the expected failure time at any fixed combination of temperature and pressure (hoop stress) under constant service conditions. i i 4.2 Miner s rule Assuming that each damage (caused by a constant service condition) is proportional to the duration of attack ( proportionality rule ) and the damages from different service conditions i may be cumulatively added ( additivity rule ) Miner s rule appears in ISO 13760 as: Equation 2 Miner s rule according to ISO 13760 i = n 1 t i t tot = t f i = 1 t fi ( Ti, σ i ) Where: t f t fi (T i,σ i ) n t i t tot Lifetime at various conditions Failure time for condition i Number of service conditions Exposure time at condition i Total exposure time The combination of equations 1 and 2 provides the tool for the determination of the expected lifetime of plastic materials subjected to varying service conditions, i.e. alterations in temperature and pressure. 8 Refer to paragraph 6 6/16

5 Results from the chlorine circulation loop testing 12 pipe specimens were started of the PB pipe material PB4267 GREY (code 3527) at 95, 105 and 115 C. The internal medium was chlorinated water of 4 ppm and the external medium was air. The results are presented in Appendix B and shown in Appendix C. All pipes started have whitened inner surfaces and failed in a brittle manner. 5.1 Testing at 95 C At 95 C two pipes were started at each pressure level of 6.0 and 4.5 bar. The average failure times are 13 350 h and 15 922 h, respectively. 5.2 Testing at 105 C At 105 C two pipes were started at each pressure level of 4.5 and 3.0 bar. The average failure times are 5 292 h and 8 183 h, respectively. 5.3 Testing at 115 C At 115 C two pipes were started at each pressure level of 4.5 and 2.5 bar. The average failure times are 2 754 h and 3 111 h, respectively. 7/16

6 Evaluation according to ASTM F 2023 According to the ASTM F 2023, the estimated time-to-failure shall be calculated at a hoop stress corresponding to a sustained internal pressure of 5.5 bar (80 psi) for the standard dimension ratio (SDR) 9 of the tested specimens, see Table 3, at the following temperature exposure conditions; I. 100% of the total time at 23 C (73 F) II. III. IV. 100% of the total time at 60 C (140 F) aka Cl-R 100% of the total time at 82 C (180 F) 25% of the total time at 60 C (140 F) and 75% at 23 C (73 F) aka Cl-TD The conditions II and IV are often referred to as Domestic continuous re-circulation (Cl-R) and Traditional domestic (Cl-TD), respectively. For the conditions I-III the lifetime predictions will be done using multiple linear regression, for condition IV Miner s rule will also be applied. 6.1 Extrapolation hoop stress The extrapolation hoop stress is based on the dimension ratio for the tested pipe. The following equation is used: Equation 3 SDR 1 σ = P 2 Where: Hoop stress equation σ P SDR Extrapolation hoop stress Internal pressure Standard dimension ratio Applying equation 3 to the tested material (SDR 9) at a pressure of 5.5 bar, gives an extrapolation hoop stress of 2.20 MPa. Table 4 Code Extrapolation hoop stress for the investigated material Nominal dimension Standard dimension ratio (SDR) Internal pressure Extrapolation hoop stress 3527 16 x 1.8 mm 9 5.5 bar 2.20 MPa 9 SDR is a selected series of numbers in which the average outside diameter to minimum wall thickness dimension ratios are constant for all sizes of tubing in each standard dimension ratio, and which are the ANSI Z17.1 Preferred Number Series R10 modified by +1. 8/16

6.2 Multiple linear regression analysis The regression analysis has been performed only using oxidative failure data, see Appendix B. Both the 3- and 4-parameter models have been applied, finally the 3-parameter model was chosen. The analysis is based on all of the 12 data points, see Appendix B. Table 5 Result from the regression analysis performed according to ISO 9080 using the 3-parameter model. Code Correlation (R 2 ) C 1 C 2 C 3 C 4 3527 0.980-11.216 5 718.426 0-189.425 According to ASTM F 2023 shall the correlation coefficient (R 2 ) be >0.9. This requirement is fulfilled for the regression analysis of code 3527. 6.3 Lifetime calculations The results from the calculations of the estimated time to failure for the different conditions stated in ASTM F 2023 are presented in Table 6 below. Table 6 Results from the lifetime calculations according to ASTM F 2023 for the pipe code 3527 Condition Temperature Hoop stress Service time fraction Estimated time to failure I 23 C (73 F) 2.20 MPa 100% >500 years II (Cl-R) 60 C (140 F) 2.20 MPa 100% 65 years III 82 C (180 F) 2.20 MPa 100% 5.6 years IV (Cl-TD) 23 C (73 F) 2.20 MPa 75% 60 C (140 F) 2.20 MPa 25% 253 years 7 Additional comments The delivered pipes showed no visual defects and no unusual behaviour were observed during the pressure testing of the PB pipe material PB4267 GREY. 9/16

8 Referred documents ASTM F 2023-05 Standard Test Method for Evaluating the Oxidative Resistance of Crosslinked Polyethylene (PEX) Tubing and Systems to Hot Chlorinated Water ISO 9080:2003 Plastics piping and ducting systems - Determination of the long-term hydrostatic strength of thermoplastics materials in pipe form by extrapolation ISO 13760:1998 Plastics pipes for the conveyance of fluids under pressure - Miner's rule - Calculation method for cumulative damage 10/16

Client info Client: Street adress: Postal code: Country: Contact person: Phone: Fax: Mail: Web: Basell Polyolefine GmbH Industriepark Höchst, D 536 65926 Frankfurt (M) Germany Dr. Klaus Könnecke +49(0)69-305 351 59 +49(0)69-305 177 72 klaus.koennecke@basell.com www.basell.com Appendix A.1 11/16

Appendix B.1 Material info Bodycote code: Trade name: Material: Colour: Nominal dimension: Arrival date at Bodycote: Amount: 3527 PB4267 Grey PB Grey 16 x 1.8 mm 2005-01-26 62 x 1.2 m Cosignor: Marking: Resin producer (date, batch no.): Pipe producer (date, lot no.): Basell Polyolefine GmbH n/a Basell Polyolefine GmbH (n/a) n/a Test info Test laboratory: Responsible: Test method: Length (total/free): Fittings: Internal medium: External medium: Conditioning time: Flow rate: Chlorine source: Chlorine level: ph: ORP: Bodycote Polymer Michael Falkhäll and Urban Westberg ASTM F 2023-05 350/300 mm PFA fittings Chlorinated water Air 1 hour 54 dm 3 /h Sodium hypchlorite (NaOCl) Average 3.97 ppm Standard deviation 0.08 ppm Average 6.83 Standard deviation 0.08 Average 878 mv Standard deviation 15 mv 12/16

Table remarks Code T Date e min d em p σ Internal Bodycote code Test temperature Start date Minimum wall thickness Mean outside diameter Internal pressure Circumferential stress (hoop stress) Appendix B.2 -> The pipe is under test Pipe remarks No remarks 13/16

Appendix B.3 Testing with chlorinated water Code T Date d em e min p σ Failure time [ C] [yymmdd] [mm] [mm] [bar] [MPa] [h] Failure mode Test time Remark 3527-3 95 050218 16.12 1.83 6.0 2.34 12 587 Brittle 3527-4 95 050218 16.12 1.83 6.0 2.34 14 112 Brittle 3527-1 95 050218 16.12 1.82 4.5 1.77 16 099 Brittle 3527-2 95 050218 16.14 1.83 4.5 1.76 15 745 Brittle 3527-7 105 050221 16.12 1.84 4.5 1.75 4 901 Brittle 3527-8 105 050221 16.12 1.84 4.5 1.75 5 682 Brittle 3527-5 105 050221 16.12 1.83 3.0 1.17 8 039 Brittle 3527-6 105 050221 16.11 1.83 3.0 1.17 8 327 Brittle 3527-11 115 050221 16.13 1.84 4.5 1.75 2 671 Brittle 3527-12 115 050221 16.11 1.85 4.5 1.73 2 837 Brittle 3527-9 115 050221 16.12 1.84 2.5 0.97 3 120 Brittle 3527-10 115 050221 16.12 1.84 2.5 0.97 3 101 Brittle 14/16

Appendix C.1 [MPa] HOOP STRESS 15/16 10 Material PB4267 GREY Dimension 16 mm, SDR 9 Bodycote Code 3527 5 Date 4 Test method ASTM F 2023 3 Test conditions Chlorine 4 ppm, ph=6.8 2 95 o C 105 o C 115 o C 1 Ductile mode Brittle mode Mixed mode Under test 0.5 0 10 0 10 1 2 10 2 10 3 4 10 4 5 10 5 6 10 6 10 7 TIME [h] 100 y 1 y 10 y 50 y

Appendix D.1 [MPa] HOOP STRESS 16/16 10 Values according to multiple linear regression Extrapolated values Material PB4267 GREY 5 Dimension 16 mm, SDR 9 4 Bodycote Code 3527 115 C 105 C 95 C 80 C 70 C 60 C 50 C 40 C Extrapolation Method ISO 9080, 3-parameter model Correlation (R2) 0.98 3 2 Date Test method ASTM F 2023 Test conditions Chlorine 4 ppm, ph=6.8 1 115 o C 95 o C 105 o C Brittle mode Under test 0.5 10 0 1 10 1 2 10 2 10 3 4 10 4 5 10 5 6 10 6 7 10 TIME [h] 100 y 1 y 10 y 50 y

EVALUATION ACCORDING TO ASTM F 2023 Evaluation of the chlorine resistance according to ASTM F 2023 of the PB pipe material PB4267 GREY Mattias Svedberg Bodycote Polymer SE-611 82 Nyköping Sweden Phone +46 155 22 14 76 Fax +46 155 26 31 25 www.bodycotepolymer.com info@bodycotepolymer.com