Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Similar documents
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

MODEL INSTALLATION INSTRUCTIONS

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Horizontal Jet Pumps 1/3-1-1/2 HP

Fire Pump Plan Review March 2010

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

WGL20, WGL20H, WGL20F Grinder Pumps

SRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Explosion-Proof Electric Unit Heaters

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Utility Distribution Systems

motralec Engineered Basins by Crane Pumps & Systems, Inc.

300 Series PA Pump and Cooler Assemblies

Pump Maintenance - Repair

1/3 HP Submersible Sump Pump with Vertical Float Switch

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

Goulds Water Technology

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

INSTRUCTION MANUAL IM042. Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

ECOFILTER PUMP VAULT

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

FAIRBANKS NIJHUIS FIRE PUMPS.

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

SUBMERSIBLE PUMP 250 WATTS, WITH FLOAT Model 45014

Dry Pit Solids Handling Pumps

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Multi-Pitch Pitching Machine USER MANUAL

CRN A-F-G-E-HQQE 3x400D 50 HZ

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

What Does A Sump Pump Do?

PRESSURE REDUCING CONTROL VALVE

MODEL NO. QWIK JON 100/101/102 SYSTEMS DATE CODE: INSTALLATION INSTRUCTIONS DATE INSTALLED: PREINSTALLATION CHECKLIST

MAC-120HE-01 Air-Cooled Chiller

APCO SLOW CLOSING AIR/VACUUM VALVES

Multistage high-pressure multistage centrifugal pumps

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

Specifications SHA Series

Series description: Wilo-Drain TC 40

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

American- Darling 5¼" B-84-B-5.

MODELS WG/WGX20* GRINDER PUMP. *Used in Hazardous Locations Class I, Division 1, Groups C & D INSTALLATION AND SERVICE MANUAL

Model 1210C Battery Powered Pump Shown. Description

INSTALLATION and OPERATION RANGE BALL CONVEYOR MODEL NO: BC-001AN

TROUBLESHOOTING GUIDE

BOWIE PUMPS OPERATION - MAINTENANCE

FLASH TANK ECONOMIZER PRODUCT GUIDE

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

Conlift1, Conlift2, Conlift2 ph+

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

The conditions below apply to the curves shown on the following pages.

Project: Model: Chk d: Date: Model 32DGUII61.5S

Morrison Bros. Co. General Product Specifications

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

Design & Construction Standards, Revised January

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Centro-Matic Automatic Lubrication Systems System Controls

OPERATION & MAINTENANCE MANUAL SUBMERSIBLE SEWAGE PUMP

NAVIEN AMERICA INC FITCH AVENUE

Frequently Asked Questions Generators

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Advantium 2 Plus Alarm

MDT5N25 & MTD5N40 SERVICE PARTS

Installation Manual DIAPHRAGM WELL TANK

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

TECHNICAL INFORMATION Bulletin

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Flygt Ball Check Valves

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

accidents which arise due to nonobservance and the safety information herein.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

COMPRESSED AIR DRYER

SunMaxx Solar Filling Station Operating Instructions

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

System Accessories Pricing. Page 0 Effective 7/02

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING. Flygt

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415

Transcription:

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

250-Series Dimensional Data 250_P2 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

250-Series Electrical Data MODEL HP VOLTAGE PHASE FULL LOAD AMPS LOCKED ROTOR AMPS THERMAL OVERLOAD TEMP STATOR WINDING CLASS CORD LENGTH FT DISCHARGE AUTOMATIC 250 1/3 115 1 5.2 8 105 C / 221 F B 10 1 1/2 251 1/3 115 1 5.2 8 105 C / 221 F B 10 1 1/2 253 1/3 115 1 5.2 8 105 C / 221 F B 10 1 1/2 257 1/3 115 1 5.2 8 105 C / 221 F B 10 1 1/2 NO MANUAL YES INTEGRAL FLOAT YES PIGGY BACK FLOAT YES INTEGRAL VERTICLE FLOAT 250-Series Cord Length Options* Model 10' 25'(-2) 35'(-3) 50'(-5) 250 Standard Optional Optional Optional 251 Standard Optional Optional Optional 253 Standard Optional Optional N/A 257 Standard Optional N/A N/A 10' cord length standard on all models. For optional lengths, add -2, -3 or -5 suffix to model number. Example: for model 250 with 35' cord. Order 250-3 WARNING: *Always use a replacement power cord assembly of the same length and type as originally installed on the Liberty product. Using a cord of improper gauge or length may lead to exceeding the electrical rating of the cord and could result in death, injury, fire or other significant failure. 250_P3 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

250-Series Technical Data IMPELLER VORTEX ENGINEERED POLYMER SOLIDS HANDLING SIZE ½ PAINT MAX LIQUID TEMP MAX STATOR TEMP THERMAL OVERLOAD POWER CORD TYPE MOTOR HOUSING / VOLUTE SHAFT HARDWARE ORINGS SEAL WEIGHT POWDER COAT 60 C 140 C CLASS B 130 C/ 266 F 105 C / 221 F SJTW (10ft & 25ft models) SJTOOW (35ft & 50ft models) CLASS 25 CAST IRON STAINLESS STAINLESS BUNA N ENGINEERED DOUBLE LIP SEAL WITH STAINLESS STEEL SPRINGS 23 LBS 250-Series Specifications 1.01 GENERAL: The contractor shall provide labor, material, equipment, and incidentals required to provide (QTY) centrifugal pumps as specified herein. The pump models covered in this specification are Series 250 single phase pumps. The pump furnished for this application shall be model as manufactured by Liberty pumps. 2.01 OPERATING CONDITIONS: Each submersible pump shall be rated at 1/3 hp, 115 volts, single phase, 60 Hz., 3450 RPM. The unit shall produce G.P.M. at feet of total dynamic head. The submersible pump shall be capable of handling effluent with 1/2 solid handling capability. The submersible pump shall have a shut-off head of 23 feet and a maximum flow of 44 GPM @ 5 feet of total dynamic head. The pump shall be controlled with: A piggy back style on/off float switch. An integrally wired on/off float switch. A Vertical Mechanical Float (VMF) type on/off switch. A NEMA 4X outdoor simplex control panel with three float switches and a high water alarm. A NEMA 1 indoor simplex control panel with three float switches and a high water alarm. A NEMA 4X outdoor simplex control panel with four float switches and a high water alarm. A NEMA 1 indoor simplex control panel with four float switches and a high water alarm. A NEMA 4X outdoor duplex control panel with three float switches and a high water alarm. 250_P4 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

A NEMA 1 indoor duplex control panel with three float switches and a high water alarm. A NEMA 4X outdoor duplex control panel with four float switches and a high water alarm. A NEMA 1 indoor duplex control panel with four float switches and a high water alarm. 3.01 CONSTRUCTION: Each centrifugal effluent pump shall be equal to the certified Series 250 SERIES pumps as manufactured by Liberty Pumps, Bergen NY. The castings shall be constructed of class 25 cast iron. The motor housing shall be oil filled to dissipate heat. Air filled motors shall not be considered equal since they do not properly dissipate heat from the motor. All mating parts shall be machined and sealed with a Buna-N o-ring. All fasteners exposed to the liquid shall be stainless steel. The motor shall be protected on the top side with sealed cord entry plate with molded pins to conduct electricity eliminating the ability of water to enter internally through the cord. The motor shall be protected on the lower side with an engineered double lip seal with stainless steel springs. The pump shall be furnished with stainless steel handle. 4.01 ELECTRICAL POWER CORD The submersible pump shall be supplied with 10, 25, 35, or 50 feet of multiconductor power cord. It shall be cord type SJTW, or SJTOOW capable of continued exposure to the pumped liquid. The power cord shall be sized for the rated full load amps of the pump in accordance with the National Electric Code. The power cable shall not enter the motor housing directly but will conduct electricity to the motor by means of a water tight compression fitting cord plate assembly, with molded pins to conduct electricity. This will eliminate the ability of water to enter internally through the cord, by means of a damaged or wicking cord. 5.01 MOTORS Single phase motors shall be oil filled, permanent split capacitor, class B insulated NEMA B design, rated for continuous duty. At maximum load the winding temperature shall not exceed 130 degrees C unsubmerged. Since air filled motors are not capable of dissipating heat they shall not be considered equal. The pump motor shall have an integral thermal overload switch in the windings for protecting the motor. The capacitor circuit shall be mounted internally in the pump. 6.01 BEARINGS AND SHAFT Upper and lower ball bearings shall be required. The bearings shall be a single ball / race type bearing. Both bearings shall be permanently lubricated by the oil, which fills the motor housing. The motor shaft shall be made of 300 or 400 series stainless steel and have a minimum diameter of.311". 7.01 SEALS The pump shall have an engineered double lip seal with stainless steel springs. The motor plate / housing interface shall be sealed with a Buna-N o-ring. 8.01 IMPELLER The impeller shall be engineered polymer, with pump out vanes on the back shroud to keep debris away from the seal area. It shall be threaded to the motor shaft. 9.01 CONTROLS All pumps can be supplied with a CSA and UL approved VMF type switch, an integrally wired wide angle tilt float switch, or piggy back type wide angle tilt float switches. The piggy back style switches are equipped with a plug that allows the pump to be operated manually without the removal of the pump in the event that a switch becomes inoperable. Manual pumps are operable by means of a pump control panel. 250_P5 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

10.01 PAINT The exterior of the casting shall be protected with Powder Coat paint. 11.01 SUPPORT The pump shall have cast iron support legs, enabling it to be a free standing unit. 12.01 SERVICEABILTY Components required for the repair of the pump shall be shipped within a period of 24 hours. 13.01 FACTORY ASSEMBLED TANK SYSTEMS WITH GUIDE RAIL AND QUICK DISCONNECT DISCHARGE Guide factory mounted rail system with pump suspended by means of bolt on quick disconnect which is sealed by means of nitrile grommets or o-rings. Discharge piping shall be schedule 80 PVC and furnished with a PVC shut-off ball valve. The Tank shall be wound fiberglass or roto-molded plastic. An inlet hub shall be provided with the fiberglass systems. Stainless steel Guide Rail Zinc plated steel Guide Rail "diameter of basin size "height of basin size "distance from top of tank to discharge pipe outlet Fiberglass cover Structural foam polymer cover Steel cover Simplex System with Outdoor panel and alarm Duplex System with Outdoor panel and alarm Separate Outdoor Alarm Remote Outdoor Alarm 14.01 TESTING The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for electrical integrity, moisture content and insulation defects. The motor and volute housing shall be pressurized, and an air leak decay test is performed to ensure integrity of the motor housing. The pump shall be run, voltage current monitored, and the tester checks for noise or other malfunction. 15.01 QUALITY CONTROL The pump shall be manufactured in an ISO 9001 certified Facility. 16.01 WARRANTY Standard limited warranty shall be 3 years. 250_P6 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.