A.V.R. R250. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. 50Hz. 47.5Hz. 57Hz LAM 1 13% 2 25% OFF LAM OFF 9

Similar documents
R438 A.V.R. Installation and maintenance R 438. This manual is to be given to. the end user T10. Armature 6- Field X2 Z1 X1 Z2 E+ E- 0V

R448 & R448 V50 A.V.R.

R450 T DETECT. 3 PH 3 PH. SENSING 7000 / 8000 RAPIDE FAST RAPIDE VOLTAGE 80V ~ 320V SHUNT / AREP SERIES PMG NORMAL NORMAL NORMAL NORMAL 5000 / 6000

Automatic Voltage Regulator User s Manual

SX460. Generator Automatic Voltage Regulator Operation Manual

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

Welcome to Linear Controls Quarterly Training

Single-Phase AC Synchronous Generator

TROUBLESHOOTING PRELIMINARY

FAULT FINDING MANUAL For Self Excited and Separately Excited Generators

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual

FAULT FINDING MANUAL. For Stamford AC Generators

Diesel Engine Driven Generators Page 1 of 6

Model EC5111 Speed Controller Isochronous / Droop

Safety technique. Emergency stop module BO 5988 safemaster

Rutland 913 Windcharger Fault Finding Guide

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

SECTION VARIABLE FREQUENCY DRIVES

TT TOYS TOYS - OWNER S MANUAL. We are delighted that you have decided to purchase this TT Toys Toys children s car.

4 LEAD DEDICATED SINGLE PHASE LIMA MAC GENERATOR MODELS 250MSL1185 AND 250MSL1152

Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE

AutoRanging Digital MultiMeter

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

ST Style Generator. Owners/Operators Manual

PM734F - Technical Data Sheet Winding 28

X. Dealing with Signature Differences

TIG INVERTER INSTRUCTION MANUAL

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

Technical Information

GPD 506/P5 Start-up Procedure and Checklist

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

Speed Control Relays SX2

Mounting Instructions. Torque Transducer. A en

GAE953 Electrical Alarm Unit 19" with Indicator

YSmart Technology Co.,Ltd

is then retained absolutely without interruption.

Thermistor motor protection

3753 en /b VE/B - VE/RG Va V riable speed drives

How To Control A Battery Cell Phone With A Battery Power Control System

Three-phase monitoring relay CM-PFE

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Residual current socket 30mA Order No.:

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Residual Current Circuit Breaker

Annex-A TECHNICAL SPECIFICATION

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

UCI274C - Technical Data Sheet

UCI274H - Technical Data Sheet

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

User Manual THR840DUK Digital Thermostat

Analog Door Phone Model LUADS MAT Code #

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Directions for use : Dosing chutes type DSX.

Power surges can also be generated by equipment in your facility such as:

Permissible ambient temperature Operation Storage, transport

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Low Voltage Alternators - 4 pole LSA 50.2

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

Problem / Solution. The problem:

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

4 DEDICATED SINGLE PHASE LIMA MAC GENERATOR LIGHT TOWER DUTY MODELS 250MSL1278 AND 250MSL1299 SERVICE PROCEDURE ELECTRICAL COMPONENT TESTING

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Synchronous motor. Type. Non-excited motors

A1000 Cheat Sheet (Open Loop Vector)

SECTION STANDBY GENERATOR TESTING AND COMMISSIONING

Manual Ranging MultiMeter

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Guidance for upgrading to GB (IEC : 2005, MOD)

Section B: Electricity

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

Please read operating instructions carefully before use and keep for further reference.

Power Generation. Power Control PCL System Generator Set Control

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

EXPERT REMANUFACTURED WIND TURBINE

PI734D - Technical Data Sheet

ABB PSPS Erich Steinmann; Generator control-2013

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

PI734B - Technical Data Sheet

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Installation and Operation Guide for PD4000 Series Power Control Center

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters

User s Manual Before using the inverter, you need to read and save the safety instructions.

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.

BCI184E - Technical Data Sheet

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

Product Information Sheet UH36 Hi Pot Tester

Report On Surge Protection & Voltage Fluctuation

Kit Watt Audio Amplifier

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Cross-beam scanning system to detect slim objects. 100 mm in

Transcription:

110 0V E+ E- VOLT STAB KNEE 47.5Hz OFF 9 SPECIAL 8 KNEE 65Hz 7 OFF KNEE 6 57Hz OFF 7 8 50Hz o 9 0 5 6 1 2 3 4 OFF 1 13% 2 25% 3 OFF 4 13% 5 25% 60Hz FREQ. & L.A.M. CONFIG.

This manual concerns the alternator which you have just purchased. We wish to draw your attention to the contents of this maintenance manual. SAFETY MEASURES Before using your machine for the first time, it is important to read the whole of this installation and maintenance manual. All necessary operations and interventions on this machine must be performed by a qualified technician. Our technical support service will be pleased to provide any additional information you may require. The various operations described in this manual are accompanied by recommendations or symbols to alert the user to potential risks of accidents. It is vital that you understand and take notice of the following warning symbols. WARNING Warning symbol for an operation capable of damaging or destroying the machine or surrounding equipment. Warning symbol for general danger to personnel. All servicing or repair operations performed on the AVR should be undertaken by personnel trained in the commissioning, servicing and maintenance of electrical and mechanical components. When the generator is driven at a frequency less than 28 Hz for more than 30 seconds with an analogic regulator, the AC power must be disconnected. WARNING This can be incorporated in a machine marked C.E. This manual is be given to the end user. - We reserve the right to modify the characteristics of its products at any time in order to incorporate the latest technological developments. The informa-tion contained in this document may therefore be changed without notice. This document may not be reproduced in any form without prior authorization. All brands and models have been registered and patents applied for. Warning symbol for electrical danger to personnel. 2

SUMMARY 1 - SUPPLY...4 1.1 - SHUNT excitation system...4 2 -...5 2.1 - Characteristics...5 2.2 - U/F fonction and...5 2.3 - option...6 2.4 - Characteristics...6 2.5 - Typical effects of the...7 3 - INSTALLATION - COMMISIONING...8 3.1 - Electrical checks on the AVR...8 3.2 - Settings...8 3.3 - Electrical faults...9 4 - SPARE PARTS...10 4.1 - Designation...10 4.2 - Technical support service...10 Disposal and recycling instructions The is an IP00 product. It must be installed inside a unit so that this unit s cover can provide IP20 minimum total protection (it must only be installed on our alternators in the appropriate location so that when viewed externally, it has a higher degree of protection than IP20). 3

1 - SUPPLY 1.1 - SHUNT excitation system The SHUNT excitation alternator is autoexcited with a voltage regulator. The regulator controls the excitation current according to the alternator s output voltage. With a very simple conception, the SHUNT excitation alternator does not have a short circuit capacity. SHUNT SYSTEM MAIN FIELD STATOR : 12 wires (marking T1 to T12) T1 T7 T2 T8 T3 T9 Varistor Induced 5+ 6- Field T4 T10 T5 T11 T6 T12 75 mm 110 0V E+ E- 140 mm 4 x holes Ø 5.8 x 50 x 115 mm F1 P1 P2 Slow fuse 250V 8 A Voltage Stability VOLT STAB KNEE 47.5Hz OFF 9 SPECIAL 8 KNEE 65Hz OFF KNEE 57Hz OFF 7 6 50Hz o 9 0 5 6 7 8 4 1 2 3 5 60Hz 1 2 4 OFF 13% 25% 3 OFF 13% 25% FREQ. & L.A.M. CONFIG. Frequency selector 50 Hz / 60 Hz for U/F fonction and adjustement ST4 Option External potentiometrer for voltage adjusting 4

2-2.1 - Characteristics - Storage: -55 C; +85 C - Operation: -40 C; +70 C - Voltage regulation: around ± 0,5 %. - Supply range/voltage detection 85 to 139 V (50/60Hz). - Rapid response time (500 ms) for a transient voltage variation amplitude of ± 20 %. - Voltage setting P1. - Stability setting P2. - Power supply protected by 8 A fuse, replacement product: Ferraz-Shawmut T084013T fast-blow fuse, 8 A FA 250 V, breaking capacity 30 ka. 2.2 - U/F Fonction and The threshold position (50 Hz - 60 Hz) to action the U/F fonction as well as the setting type is selected using the potentionmeter. KNEE 47.5Hz OFF SPECIAL 8 KNEE 65Hz OFF KNEE 57Hz OFF 7 9 6 7 8 6 50Hz 9 0 5 WARNING: The jumper settings must correspond to the rated operating frequency (see the nameplate on the alternator). Risk of destruction for the alternator. o 1 2 3 4 5 60Hz 1 4 2 3 OFF 13% 25% OFF 13% 25% The threshhold position and fonction settings are done with the jumper. Operating at 50 Hz: (U/F gradient) 0: threshold at 48 Hz without for impacts between 30 and 40% of the rated load. 1: threshold at 48 Hz with 13% for impacts between 40 and 70% of the rated load. 2: threshold at 48 Hz with 25% for impacts > 70% of the rated load. Operating at 60 Hz: (U/F gradient) 3: threshold at 58 Hz without for impacts between 30 and 40% of the rated load. 4: threshold at 58Hz with 13% for impacts 40 and 70% of the rated load. 5: threshold at 58Hz with 25% for impacts > 70% of the rated load. Specific operating 6: threshold at 57Hz without for speed variations at a steady state > 2 Hz 7: threshold at 65Hz without for variable speed and tractelec / gearlec (U/F gradient). 8: special: the factory setting 48Hz 2U/F gradient ; a special programme is possible on request. This programme must be specified before ordering, during the project study. 9: threshold at 47.5 Hz without for speed variations at a steady state > 2 Hz. For hydraulic applications, it is advisable to select: - position 0 for 50 Hz - position 3 for 60 Hz 5

2.3 - option Potentiometer for voltage setting, 1000 W / 0,5 W min: setting range ± 5 %. - Remove the ST4 jumper. It is advised to use the at 25% for load impacts > at 70% of the genset rated power. Voltage UN Voltage 0,85 UN U/f For wiring up the external potentiometer; the earth wires must be isolated as well as the potentiometer terminals (wires at the same voltage as the power). 0 ST3 48 or 58 Hz fc 50 or 60 Hz fn 2.4 - characteristics (Load Acceptance Module) 2.4.1 - Voltage drop The system is integrated in the It is active as standard. It can be adjusted to 13% or 25%. - Role of the (Load Adjustment Module): On application of a load, the rotation speed of the generator set decreases. When it passes below the preset frequency threshold, the causes the voltage to drop by approximately 13% or 25% and consequently the amount of active load applied is reduced by approximately 25% to 50%, until the speed reaches its rated value again. Hence the can be used either to reduce the speed variation (frequency) and its duration for a given applied load, or to increase the applied load possible for one speed variation (turbo-charged engines). To avoid voltage oscillations, the trip threshold for the function should be set approximately 2 Hz below the lowest frequency in steady state. 2.4.2 - Gradual voltage return function During load impacts, the function helps the genset to return to its rated speed faster thanks to a gradual increase in voltage according to the following principles: - if the speed drops between 46 Hz and 50 Hz, the rated voltage follows a fast gradient as it is restored. - if the speed drops below 46 Hz, since the engine needs more help, the voltage follows a slow gradient as it returns to the reference value. U 0 Drop N > 46 Hz Drop N < 46 Hz Time 6

2.5 - Typical effects of the with a diesel engine or without a (U/F only) 2.5.1 - Voltage UN Transient voltage drop 0,9 0,8 with (U/f) without Time 0 1 s 2 s 3 s 2.5.2 - Frequency fn Max speed drop with 0,9 0,8 without Time 0 1 s 2 s 3 s 2.5.3 - Power Load on shaft (kw) Shedding due to "" Load variation Time 0 1 s 2 s 3 s 7

3 - INSTALLATION - COMMISSIONING 3.1 - Electrical checks on the AVR - Check that all connections have been made properly as shown in the attached wiring diagram. - Check that the position of the jumper corresponds to the operating frequency. - Check whether the ST4 jumper or the remote adjustment potentiometer have been connected. 3.2.2 - Special type of use WARNING Excitation circuit E+, E- must not be left open when the machine is running: damage will occur. 3.2.2.1 - field weakening (SHUNT) 3.2 - Settings 110 0V E+ E- The different settings made during the trial are to be done by qualified personnel. Respecting the load speed specified on the nameplate is vital in order to start a settings procedure. After operational testing, replace all access panels or covers. The only possible settings on the machine are to be done with the 3.2.1 - settings (SHUNT system) Initial potentiometer positions - voltage setting potentiometer P1 for the : full left - remote voltage setting potentiometer: in the middle. Operate the alternator at its rated speed: if the voltage does not rise it is necessary to re-magnatise the magnetic circuit. - slowly adjust the voltage potentiometer of the P1 until the output voltage reaches its rated value. - Stability setting with P2. The exciter is switched off by disconnecting the power supply (1 wire - 0 or 110V). Contact rating: 16A - 250V AC Do not reclose the power supply until the voltage has reached a value 15% of the rated voltage (approximately 5 seconds after opening) 3.2.2.2 - field forcing 110 0V E+ E- (400V - 10A) - + Battery (B Volt) The battery must be isolated from the mass. t Excitation Inducer Diode Exciter field may be at line potential. 8

3.3 - Electrical faults Fault Action Effect Check/cause No voltage at no load on start-up Voltage too low Voltage too high Voltage oscillations Voltage correct at no load and too low when on load (*) Connect a new battery of 4 to 12 volts to terminals E- and E+ respecting the polarity for 2 to 3 seconds Check the drive speed Adjust potentiometer Adjust stability potentiometer Run at no load and check the voltage between E+ and E- on the The alternator starts up and its voltage is still correct when the battery is removed. The alternator starts up but its voltage does not reach the rated value when the battery is removed. The alternator starts up but its voltage disappears when the battery is removed Correct speed Speed too low Adjustment ineffective - Lack of residual magnetism - Check the connection of the voltage reference to the - Faulty diodes - Induced short circuit - Faulty - Exciter field short-circuited - Short-circuit in the main field. Check the resistance Check the connections ( may be faulty) - Field windings short-circuited - Rotating diodes burnt out - Main field winding short-circuited - Check the resistance Increase the drive speed (Do not touch the pot (P1) before returning to the correct speed.) - Faulty - 1 faulty diode - Check the speed: possibility of cyclic irregularity - Loose terminals - Faulty - Speed too low on load (or U/F gradient set too high) - Check the speed (or U/F gradient set too high) - Faulty rotating diodes - Short-circuit in the main field. Check the resistance - Faulty induced excitaion (*) Warning: For single-phase operation, check that the sensing wires coming from the are correctly connected to the operating terminals (see the alternator manual). Voltage disappears during operation Check the, the surge suppressor, the rotating diodes and replace any defective components The voltage does not return to the rated value - Exciter winding open circuit - Faulty induced excitation - Faulty - Main field open circuit or short-circuited Warning: after setting-up or troubleshooting, replace all access panels or covers. 9

4 - SPARE PARTS 4.1 - Designation Description Type Code AEM 110 RE 019 4.2 - Technical support service Our technical support service will be pleased to help you with any information needed. For replacement part orders, it is necessary to indicate the type and the code number of the Please contact your usual correspondant. An extensive network of service centres is available to rapidly supply any necessary parts. In order to ensure the correct operation and safety of our machines, we strongly recommend that original manufacturer s spare parts are used. Failure to do so, will discharge the manufacturer from liabilty in the case of damage. 10

Disposal and recycling instructions We are committed to limit the environmental impact of our activity. We continuously survey our production processes, material sourcing and products design to improve recyclability and diminish our footprint. These instructions are for information purposes only. It is the user responsibility to comply with local legislation regarding product disposal and recycling. The oil and grease from the lubrication system should be considered as a hazardous waste and has to be handled according to local legislation. Recyclable materials Our alternators are mainly built out of iron, steel and copper materials, which can be reclaimed for recycling purposes. These materials can be reclaimed through a combination of manual dismantling, mechanical separation and melting processes. Our technical support department can provide detailed directions on products dismounting upon request. Waste & hazardous materials The following components and materials need a special treatment and need to be separated from the alternator before the recycling process: - electronic materials found in the terminal box, including the Automatic Voltage Regulator (198), Current Transformers (176), interference suppression module (199) and other semi-conductors. - diode Bridge (343) and Surge suppressor (347), found on the alternator rotor. - major plastic components, such as the terminal box structure on some products. These components are usually marked with plastic type information. All materials listed above need special treatment to separate waste from reclaimable material and should be handed to specialized disposal companies. 11

12

13

14

Service & Support Our worldwide service network of over 80 facilities is at your service. This local presence is our guarantee for fast and efficient repair, support and maintenance services. Trust your alternator maintenance and support to electric power generation experts. Our field personnel are 100% qualified and fully trained to operate in all environments and on all machine types. We know alternators operation inside out, providing the best value service to optimize your cost of ownership. Where we can help: Conception Consulting & specification Maintenance contracts Life Extension Remanufacturing System upgrade Start-up Commissioning Training Optimization Monitoring System audit Operation Genuine spare parts Repair services Contact us: Americas: +1 (507) 625 4011 Europe & International: +33 238 609 908 Asia Pacific: +65 6263 6334 China: +86 591 88373036 India: +91 806 726 4867 service.epg@leroy-somer.com Scan the code or go to: www.lrsm.co/support

www.emersonindustrial.com www.emerson.com/epg