Mixing Valves. ARGUS Application Note: Mixing Valves

Similar documents
Industrial Steam System Process Control Schemes

Condensing Boiler Efficiency

Technical Support Bulletin Nr. 20 Special AC Functions

HVAC Processes. Lecture 7

Applying Pressure Independent Control Valves in H.V.A.C. Systems. A Presentation to: Orange Empire ASHRAE Santa Ana Nov. 17, 2009

presents Hydraulic Separation Beyond Primary / Secondary Piping

ABB i-bus KNX Fan Coil Controller FC/S 1.1

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Printing and Publishing Energy Savings Guide

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

Example. Fluid Power. Circuits

HEAT RECOVERY FROM CHILLED WATER SYSTEMS. Applications for Heat Reclaim Chillers

Frequently Asked Questions

HOT WATER SYSTEMS CONTENTS

HVAC: Cool Thermal Storage

Floor Heating Warehouse.co.uk

Lesson 36 Selection Of Air Conditioning Systems

Glossary of Heating, Ventilation and Air Conditioning Terms

HVAC Systems: Overview

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Fundamentals of Hydronic Design

CGC s Hybrid System Loop Control

HERZ-Thermal Actuators

CHILLER PLANT CONTROL MULTIPLE CHILLER CONTROLS

VARIABLE VOLUME / VARIABLE SPEED SYSTEMS APPLICATIONS

The Chilled Water and Hot Water Building Deferential Pressure Setpoint Calculation Chilled Water and Hot Water Pump Speed Control

Using Building Energy Management Systems (BEMS) Best Practice for Energy and Carbon Savings.

Principals of Condensing Boiler System Design

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Boiler Applications Drawings

By Steven C. Severini, P.E., Member ASHRAE

IDEA Presentation SMALL CAMPUS CHILLED WATER PLANT OPTIMIZATION.

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

M&V of Hot Water Boiler Plant. Boban Ratkovich, P. Eng, CEM, BESA, LEED AP President CES Engineering Ltd

Building Performance With District Cooling

How Ground/Water Source Heat Pumps Work

Natural Gas Energy Efficiency Opportunities for Commercial & Industrial Customers. Michael Pace Lead Engineer C & I Efficiency Programs

Why and How we Use Capacity Control

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

for Plans Examiners and Building Inspectors

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Laddomat Charging unit

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

Cast-Iron Performance Meeting today s commercial demands with effi ciency, strength and intelligent controls.

Description of functions

To Condense, or Not to Condense? Installation Practices Leave Boiler Savings on the Table

News in Data Center Cooling

FILLING AND PURGING THE SYSTEM

Process Control Primer

Y-200 Multi-Stage Sequencer

Heating, ventilation and air conditioning (HVAC) equipment. A guide to equipment eligible for Enhanced Capital Allowances

Contents. Introduction

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Recognizing and understanding schematic symbols will enable you to comprehend a circuit s function.

Air Conditioning Clinic

Sanitary Type Electronic Flow Switches

Ener.co & Viridian Energy & Env. Using Data Loggers to Improve Chilled Water Plant Efficiency. Randy Mead, C.E.M, CMVP

Building Technologies. Thermostats and room controllers. General Product range overview Thermostats

Hot water supply, distribution and use

C. starting positive displacement pumps with the discharge valve closed.

Commissioning - Construction Documents (Page 1 of 6)

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

With the background of fulfilling public commitments for ECONO-PILOT ENERGY-SAVING SYSTEM FOR WATER PUMPS

EcoDesign & Labelling Directive (ErP)

Some Criteria for Choosing a Steam Boiler for a Microbrewery

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

SECTION Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)

HCE80/HCC80/HCE80R/HCC80R

FYI > California Title 24

Design guidelines for hybrid boiler systems.

Adjustable room thermostat for heating only or cooling only systems

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Commercial Refrigeration Temperature and Defrost Controls

Laddomat 21. For accumulation when using a wood-fired boiler. Picture 1. The wood-fired boiler is is connected to to. accumulator tank with bypass

Building Energy Systems. - HVAC: Heating, Distribution -

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

Commercial Semi-Instantaneous Water Heaters

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics

Centrifugal Fans and Pumps are sized to meet the maximum

Synergy of demand water heaters with solar and radiant floor heating

Comfort Compact Controller ZG 215N

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Chapter 10. Control Design: Intuition or Analysis?

EHDC. Cooling system for Data Center and server cabinets.

Technology: Heating, Ventilation and Air Condition (HVAC) Zone Controls

Gas Boilers - Commercial

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

OEH Energy Efficient HVAC for Business Training Course

Electric Coolant Pumps. Always at the Correct Temperature

newsletter engineers energy-saving strategies for Water-Source Heat Pump Systems volume 36 2 providing insights for today s hvac system designer

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

HC900 for Boiler Control Applications

Transcription:

Mixing Valves Most radiant hot water heating systems in greenhouses use mixing valves to control the temperature of heating pipes. Both 3-way and 4- way valves are commonly used. Mixing valves provide the ability to: Regulate the temperature of the heating pipes in a climate by controlling the flow of hot water from the central supply system to the local heating zone. Proportion and ration the available system heat over several independent zones, when boiler capacity is temporarily exceeded. By carefully adjusting the temperature of the water in the heating pipes, the Argus system is able to closely balance the heating energy applied with the heat loss in each compartment. This results in very even temperature management. The computer constantly monitors the compartment and outdoor conditions and compares them to target values. It then calculates the desired pipe temperature required to sustain the current air target setpoint and positions the mixing valve to achieve this pipe temperature in the local heating zone. temperature sensors are used to provide feedback correction for valve positioning. Rev. 2: February 5, 2003 1

Tyes of Mixing Valves 3-Way Mixing Valves A Typical 3-Way Mixing Valve Installation Gradations No Recirculation Full Heat No Heat Some Recirculation Some Heat Cool 3-way Mixing Valve SUPPLY BOILER Shunt RETURN ZONE 1 ZONE 2 ZONE 3 A typical 3-way valve installation. A shunt pump provides boiler mixing (mixes hot water from the boiler supply with return water from the greenhouse zones) and keeps the boiler return at a higher temperature to reduce thermal shock and condensation. Figure 1. A typical 3-way mixing valve installation Three-way valves are typically used in situations where the central supply and return pipes are not recirculated by a ring main transport pump. recirculation pumps and mixing valves are used to circulate and recirculate the contents of each zone s heating pipes. When no heat is required, this is a closed loop (see Figure 2). When heat is required, the Argus system opens the mixing valve, allowing hot water from the heating supply to be drawn into the zone loop by the zone pump (see Figure 3). When fully opened, no recirculation occurs within the compartment and full heating occurs (see Figure 4). Three-way valves must be used when heat/cold storage is used with CO 2 extraction systems, as the design does not contaminate the main return water temperature with supply water. This is a good design choice for operations up to a few acres in size with supply and return pipes up to a few hundred feet in length. 2

. 3 - Way Mixing Valve, No Heat 3 - Way Mixing Valve Some Recirculation, Some Heat Gradations Cool Gradations Mixing Valve No Heat Mixing Valve Some Heat Figure 2. Figure 3. 3 - Way Mixing Valve No Recirculation, Full Heat Gradations Mixing Valve No Recirculation Full Heat Figure 4. 3

4-Way Mixing Valves A Typical 4-Way Mixing Valve Installation Gradations No Recirculation Full Heat No Heat Some Recirculation Some Heat Cool Loop Transport Loop 4-way Mixing Valve Loop BOILER Loop SUPPLY TRANSPORT LOOP Transport Loop Valve RETURN ZONE 1 ZONE 2 ZONE 3 A typical 4-way valve installation. A transport pump pushes water out to the zones allowing the use of much longer supply and return lines. The boiler loop pump circulates all boiler water. Any supply water not taken up by the transport loop is returned to the boiler to prevent thermal shock. Condensation within the boiler is prevented by controlling the transport loop valve. Figure 5. A typical 4-way mixing valve installation Four-way valves are used when the zone is supplied by a transport or ring main system that has its own circulation pump to create a pressure differential between the supply and return sides of the system. In these systems, both the ring main and the individual zones can be continuously circulated independent of one another. When no heat is required by any of the zones, the ring main recirculates its hot water via a transport pump and each zone recirculates its water by means of a zone recirculating pump (see Figure 6). When fully closed, both the supply and return pipes to the zone are isolated from the ring main. When heat is required, the 4-way valve opens to allow supply water to enter the zone and return water to exit the zone (see Figure 7). When full opened, supply water flows directly through the zone with no recirculation (see Figure 8). Four-way valves are normally only used with transport systems. They provide alternate pathways between the supply and return valves for any unused hot water pushed through by the transport pump. 4

. 4 - Way Mixing Valve, No Heat 4 - Way Mixing Valve Some Recirculation, Some Heat Gradations Cool Gradations Figure 6. Figure 7. 4 - Way Mixing Valve No Recirculation, Full Heat Gradations Figure 8. 5

Mixing Valve Control The Argus control system is supplied with several specialized programs for managing hot water heating systems. By using pipe temperature control for operating mixing valves, the system is extremely responsive to changes in the amount of heating energy delivered to the climate zones. This helps to precisely match the current heating demand, avoiding costly overshoots. Mixing valve movements can be controlled by either time or an optional position sensor. The control system can provide either direct digital control (ON/OFF or Tri State Floating) or analog (4-20ma) control output depending on the type of valve motor actuators you are using. Several specialized mixing applications are supported including: Heat Mixing Valves Heat Mixing Valves request specific pipe temperatures based directly on their own current climate requirements. Minimum pipe temperatures can be specified for each heating period as well as during CO2 application. You can also specify the minimum pipe temperature to use for each valve when snow-loading conditions are present. Maximum pipe temperature settings are provided to protect heat distribution equipment such as plastic piping. Crop activation settings enable you to configure time and light based pipe temperature increases. return temperature limit settings can be used to protect your central heating equipment and to allocate the available heat to specified priority zones during peak demand periods. Mixing valve operation can be grouped with circulating pumps. Many lead/lag pump options are provided including alternating or fixed cycling, and pipe temperature based secondary circ pump operation Calibration settings to allow for loose linkages and non-linear valve opening position/output proportional response ratios. 6

. Heat /Cool Applications In addition to the standard heat zone features, you can manage mixing valves on systems that provide both heating and cooling through the same distribution equipment. Linearization tables to correct for non uniform output in relation to percent opening. Stand Alone Mixing Valves These types of valves operate similar to heat zone mixing valves except that they are optimized for non-climate uses such as bench or soil heating. Direct sensor based values can be used to control operation or multiple external values can be mapped and calibrated to govern valve operation. Transport Mixing Valve Settings A transport mixing valve controls the pipe temperature of a hot water heating system's distribution piping (commonly known as a transport loop or a ring main). Usually, several heating zones draw their hot water from this common transport loop. The pipe temperature of the transport loop is controlled by the requirements of the heating zones connected to it. Floating temperature offset above the highest zone request values. This enables the transport line to always attempt to have hotter water available (within the system wide constraints) than the highest temperature requested by the zones it supplies. 7