Synergy of demand water heaters with solar and radiant floor heating
|
|
|
- Marcus Newman
- 9 years ago
- Views:
Transcription
1 Synergy of demand water heaters with solar and radiant floor heating... butter with a chain saw Heating water with electricity is like cutting -Amory Lovins Everybody likes a hot shower, but that doesn t mean I want a nuclear powered shower -Larry Bohs
2 We ve been using tankless propane water heaters for years now and they have improved the designs to the point that it s all we install these days but there are a few misconceptions about them and some limitations as well as some opportunities that need to be considered. First is the assumption that you can just take out a tank water heater and install a demand water heater and all will be well. Demand water heaters suffer from maximum through put issues that can lead to variable hot water pressure and they can send out slugs of un-heated water (the cold water sandwich effect.) which require tempering tanks to resolve. These issues are discussed in my essay in Fine Homebuilding Magazine. Second is the energy efficiency issue. While tankless gas water heaters do use less energy to heat a given quantity of water per year, the fact that they can provide as much as 5-8 gallons per minute of hot water all day long may mean that you may end up using so much more hot water that your energy bill will actually go up. (I think that if you have lots of teenagers the most energy efficient water heater may be a 20 gallon electric tank that runs out of hot water quickly so they have to keep their showers short.) I think of you a demand water heater as more of a luxury item than an energy efficiency item for this reason. For this reason it is best to use a solar water heater to pre-heat water for the demand water heater to mitigate the tendency to use more hot water when faced with an inexhaustible supply. Due to the fact that solar water heaters sized to provide sufficient hot water in the winter can provide far more than necessary in the warmer months a combination of solar and demand water heating can be ideal to provide heat for a radiant floor system that would then be able to use excess heat collected from the sun to warm the floors of the home Adding a solar water heater to pre-heat the water going into the system. Once we have solved the cold water sandwich and the variable pressure problems by linking the demand water heater system with the 12 gallon tempering we still may not see the promised savings due to the energy efficiency of the demand water heater simply because we never run out of hot water so we tend to use more of it.
3 With all these new tax credits it sure would be tempting to hook it up to a solar water heater. As it turns out it s a piece of cake, just plumb the solar water heater into the line running from the hot water heater to the cold water inlet of the demand water heater. Up until now everything I said about demand water heaters could apply to any brand, but once you hook up a solar heated water tank you really need a unit that can measure the temperature of the incoming water and modulate the flame to only heat it as much as needed to meet the desired output temp. To the best of my knowledge the Rinnai, Tagaki, and Rheem/Ruud are the only brands that can do this. Set the output temp on the solar tank to about 170 degrees or so and when the pump cycles it won t cycle for long and the heated water will just flow straight through the DWH to the tempering tank and then out to the house through the tempering valve at 120 degrees. Use a radiant floor to turbo charge your solar panels. Finally, we ve noticed that in our homes with solar hot water sized to provide sufficient hot water in the winter months frequently will have much more water heating capacity than many families have a use for in the spring and fall when their heating systems are burning fuel to heat the homes. Many days will start out with pretty hot water in the solar storage tank from the day before even if it s cold enough outside that the furnace is fired up and heating the house. By linking the solar hot water to a section of radiant floor we can dump that excess heat into the house. Every BTU from the sun that we can use to heat the home is a BTU we don t have to buy from a utility company. By dumping the heat from the sun into the floor when appropriate we can keep the solar tank cool so that when the sun comes out we will have someplace to put the heat. (Everybody asks me if the house won t get too hot in the summer, if the thermostat doesn t call for heat it will just accumulate in the solar storage tanks) because the demand water heater is a very capable back up we can use all our solar BTU s for space heating and still not have to worry about not having enough heat to take a shower, or ten showers in a row if the need should arise. We use these systems to supplement the heating needs of the house. To use one of these systems as the sole heat source for the house would necessitate hiring an engineer to do the sizing. Our homes generally have heat pumps and woodstoves so if the radiant system should prove inadequate to the needs of the
4 home on a very cold day there are multiple back-up options. Without the solar assist our experience has been that radiant floor heat is actually less energy efficient than a well designed and installed 15 SEER heat pump or a 90+ gas furnace. Lessons learned from designing and installing combined demand/solar/radiant heating systems People have been using potable water in radiant floor applications for years but there is some evidence indicating that there may be negative health implications to breathing steam in a shower while bathing in water that has been heated and cooled repeatedly especially in staple-up (non-slab) radiant floor applications. Isolating this water is therefore considered a best practice. The system shown uses a flat plate heat exchanger to isolate the radiant water from the potable water. Since radiant floor systems are often creatively zoned the design shows slab zone as well as a staple up zone such as would be used with a plywood subfloor or warm-board. Slabs generally utilize two pumps, one circulates the water continuously through the floor to minimize hot spots and over heating the other adds heat to the floor as required by the thermostat. Staple up systems generally are insertion only as they operate at much higher temperatures in order to push the heat across the radiant barrier of the finished flooring. Linking a solar collector to a slab radiant floor is generally much more effective than linking it to staple up due to the fact that the water displaced out of a slab by the incoming water will generally be less than 75 degrees but the water returning from a staple up radiant floor can easily be 120 degrees. (Assuming it can flow into a small zone at 135 degrees and only lose 15 degrees to the floor before leaving to return to the heat exchanger.) In this situation the water leaving the heat exchanger and flowing into the solar storage tank would be 120 degrees and the ability of the solar storage tank to gain BTUs from the sun would be compromised. A solution to this problem is to install a thermostat on the pipe leaving from the staple up floor manifold that would break the circuit to the staple-up circulation pump if the floor was returning water hotter than 110 degrees to the heat exchanger. Since this would only affect the staple up loop it would leave the slab loop and tempering tank thermostat fully functional while the staple up floor is resting. Many of our homes have very small staple up zone dedicated to the floor of the master bathroom only. These zones are so small that there is no practical way to run them off the heat exchanger. In lieu of this we run them off the re-circulating hot water system using the same time delay occupancy sensor that controls the bath fan in that bathroom circulates the hot water returning from the master bath to the water heater through a small staple up loop in the bath room floor on the way back to the water heater as
5 demanded by occupancy in the master bathroom. A bypass valve in the master bath vanity or similar discrete location allows the recirculation to bring hot water to the bath in the summer time with out heating the bathroom floor. Because these systems can have numerous zones the pump that circulates water through the heat exchanger must respond to numerous different thermostats. The simple way to accomplish this is to allow those thermostats to control the flow of water through the heat exchanger on the radiant side and to use a reed type low voltage flow switch to sense that flow of water and activate the pump on the water heater side. To accomplish this in the simplest way possible we link the Sika VS 20M low flow reed switch (.59 gpm sensitivity) with a Honeywell RA89A unified transformer switch controller per the side bar. Working out all the details and nuances involved in making these systems operate efficiently has been the work of years of research, plagiarism, and all too much trial and error. I want to take this opportunity to publicly apologize to all my very patient and tolerant clients who have welcomed me into their homes over and over again as I worked the bugs out of these experimental systems. I hope to atone for this by sharing these lessons learned in hopes that future builders may profit from my mistakes.
TANKLESS WATER HEATER INSTALLATION DIAGRAMS
TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water
FYI > California Title 24
FYI > California Title 24 Rinnai America Corporation ("RAC") prepared the below summary of California Title 24, primarily based on the California Energy Commission s 2013 Building Energy Efficiency Standards.
Integrated Solar Radiant Systems
Integrated Solar Radiant Systems William Shady PE President Topics Radiant heating Indoor air quality Radiant Cooling Project Photos Questions and answers The goal for our clients Healthy Comfort Why Radiant
Get more from your hot water
Get more from your hot water 3 action sheet Whether you re choosing a new hot water system or using the one you already have, there are some easy ways to reduce your energy use without compromising on
Laddomat 21. For accumulation when using a wood-fired boiler. Picture 1. The wood-fired boiler is is connected to to. accumulator tank with bypass
Picture 1 For accumulation when using a wood-fired boiler The wood-fired boiler is is connected to to an accumulator tank with bypass and dwh with......... Laddomat 21 and this is is how it it works...
CONDENSING TANKLESS WATER HEATERS
Ty Tipton, Tipton Company Brian Fenske, Navien America CONDENSING TANKLESS WATER HEATERS THE BASICS OF TANKLESS WATER HEATERS Tankless water heaters are available in Electric Natural gas Propane fired
GENERAL SUPPLEMENT 410. Radiantec CONTROLS FOR RADIANT HEATING CONTROLS PURPOSE OF RADIANTEC CONTROLS
Radiantec ONTROLS FOR RADIANT HEATING GENERAL SUPPLEMENT 410 ONTROLS This supplement presents a layman s language narrative about Radiantec ompany controls, their design and their installation. This supplement
Tankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners
Tankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners Your Questions Answered Common applications Benefits of performance How to select, size and install Efficient water heating
RESEARCH HIGHLIGHT. The Impact of Heat Pump Water Heaters on Whole-House Energy Consumption
RESEARCH HIGHLIGHT December 2014 Technical Series 14-104 The Impact of Heat Pump Water Heaters on Whole-House Energy Consumption INTRODUCTION Heat pump water heaters are one of the most energyefficient
Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs.
Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs. Fuel for thought Choosing the right heating system for
BPC Green Builders. Green building for new and existing homes. Health Comfort Energy
BPC Green Builders Green building for new and existing homes Health Comfort Energy Mechanical Systems Installed HVAC Systems Primary energy source large, roof mounted, solar thermal array (AET flat plate)
Condensing Boiler Efficiency
Condensing Boiler Efficiency Date: July 17, 2012 PRES E NT ED BY DO N L E O NA RDI LE O N A RD I I NC. HV AC T RAI N I N G & C ON SU LT IN G Concepts 1 The current state of evolution in boiler design 2
Water Heating and Heat Recovery 1
PID 113 (488) Water Heating and Heat Recovery 1 Florida Power Corporation 2 ENERGY-EFFICIENT WATER HEATING: IT S THE EASIEST WAY TO SAVE ENERGY DOLLARS Anywhere from 10% to 25% of the money you spend on
Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC 916 549 7080 gary@aim4sustainability.
Codes and High Performance Hot Water Systems Gary Klein Affiliated International Management, LLC 916 549 7080 [email protected] Annual Energy Use for Heating Water Natural Gas Gallons Per Day
High Efficiency Heating
High Efficiency Heating Mike Pace Senior Engineer National Grid C&I Efficiency Programs Prescriptive Controls Energy Star Programmable Thermostats A thermostat that is able to be programmed to set back
Building Energy Systems. - HVAC: Heating, Distribution -
* Some of the images used in these slides are taken from the internet for instructional purposes only Building Energy Systems - HVAC: Heating, Distribution - Bryan Eisenhower Associate Director Center
Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS
Solar MAX ELECTRIC BOOSTED SPECIFICATIONS Proudly Australian ALL AUSSIE GAS & ELECTRIC BOOSTED WATER S Harness the power of the Sun. 1 Energy efficiency that s out of this world AquaMAX high efficiency
General Information. Do programmable thermostats really save energy?
General Information Do programmable thermostats really save energy? Yes, programmable thermostats can save energy which in turn saves you money on your utility bill. The US Department of Energy states
Water Heaters. Condensing Storage. In my 30-plus years as a plumbing contractor,
Condensing Storage Water Heaters These heaters are up to 96 percent efficient and typically easier to retrofit than tankless models by Jim Lunt In my 30-plus years as a plumbing contractor, I ve replaced
CHAPTER 9: WATER HEATING
Chapter 9: Water Heating 145 CHAPTER 9: WATER HEATING Energy costs for water heating can be as great as the costs for heating, for an energy efficient house, in a mild climate. Estimating hot water usage
Multi Drum Heat Storage By John Canivan
Multi Drum Heat Storage By John Canivan http://www.jc-solarhomes.com/drum.htm Solar collectors are used to harvest the sun s heat energy from rooftops, but solar collectors are just the tip of the iceberg
SECTION 22000. Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)
SECTION 22000 Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters) PART I - GENERAL A. Description This section includes requirements for materials for installation of Hot
Selecting a New Water Heater
U ENERGY EFFICIENCY AND RENEWABLE ENERGY CLEARINGHOUSE Selecting a New Water Heater Many homeowners wait until their heater fails before shopping for a replacement. Because they are in a hurry to regain
Fully Pumped Systems
Fully Pumped Systems (also see the picture gallery and System Basics) The term for any boiler that uses a pump to move all the heat from the boiler to every part of the system is fully pumped. As a rule
How to choose a heat pump and use it wisely
How to choose a heat pump and use it wisely Contents How does a heat pump work? 2 Insulating your home 3 Heat loss in the home Not all heat pumps are created equal 4 Choosing a heat pump 4 Choosing by
Solar Aquaponics Designing a 100% Solar Aquaponics Greenhouse
Solar Aquaponics Designing a 100% Solar Aquaponics Greenhouse Dan Chiras, Ph.D. Director, The Evergreen Institute Gerald, MO 63037 www.evergreeninstitute.org Topics Creating a 100% solar operation Efficiency
ENERGY EFFICIENCY ENERGY EFFICIENCY: Saving Dollars While Clearing the Air
: Saving Dollars While Clearing the Air After labor and food, energy is the largest controllable cost in a restaurant s operation. And energy is a great place to start in becoming a green restaurant because
UNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-23 09 93 (November 2015) ----------------------------- Preparing Activity: USACE Superseding UFGS-23 09 23 (May 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS References
Hot Water South Australia
Hot Water South Australia The Offer Hot Water Solutions Offered in - Natural Gas - Electric - LPG Full Product Range in - Traditional Tank - Instantaneous - Heat Pump - Solar Other Services Include - Delivery
SunMor SM-V30 Solar Water Heater Installation Manual
SunMor SM-V30 Solar Water Heater Installation Manual Rev. 1.02 Congratulations on the purchase of your new SunMor SM-V30 from Nature s Comfort LLC! You must read this entire instruction manual before beginning
Using Water Heaters for Radiant Heat
Using Water Heaters for Radiant Heat Gas-fired water heaters can provide reliable, efficient space heating as well as domestic hot water by Bill Clinton, Jurnal of Light Construction, Web Page from 1999
HOW TO-SOLAR HOT WATER
HOW TO-SOLAR HOT WATER GREENPOWERSCIENCE.COM February 21,2008 Heat your water or home for less than $500. Heating water for a shower or water to circulate in a floor radiator or underfloor heating system
DESIGN AND CONSTRUCTION SUGGESTIONS
DESIGN AND CONSTRUCTION SUGGESTIONS Designing a system is easier than you might think. Radiantec will help. Call us for assistance with your design. 1-800-451-7593 TABLE OF CONTENTS 1. Radiant Heating
Drake Landing Solar Community
www.dlsc.ca Innovation. Drake Landing Solar Community The Drake Landing Solar Community (DLSC) is a master-planned neighbourhood of 52 homes in the Town of Okotoks, Alberta, Canada that has successfully
RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00
RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls
Thermal Imaging for Home Inspectors
Thermal Imaging for Home Inspectors Structural member placement The gabled end of a cathedral ceiling. Note the studs and the ceiling joists with blocking. What is that glow in the upper right hand corner?
ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International
ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International Presentation Overview Water Heater Piping Strategies How to size a water heater?
Range Tribune HE Solar Unvented Direct and Indirect Cylinders
Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar cylinders have been designed specifically with Solar applications in mind and are based on the highly successful Range
Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide
Water Circulation Pumps & Circulators Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide Taco Catalog # 100-41 Supersedes: 08/07/15 Effective Date: 09/01/15 Printed in
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
STATE SUPER HIGH EFFICIENCY Up To 96% Thermal RESIDENTIAL PREMIER POWER-VENT MODELS
STATE SUPER HIGH EFFICIENCY Up To 96% Thermal GAS WATER HEATERS Efficiency RESIDENTIAL PREMIER POWER-VENT MODELS PREMIER POWER-VENT DV RESIDENTIAL GAS WATER HEATER The ideal choice for high-demand homes
Making Your Home Ready For Solar Water Heating
Making Your Home Ready For Solar Water Heating During construction or a major renovation, making a home ready to use solar energy can be easy and inexpensive. When the time comes to install your solar
The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.
MSV: Square Footage: 24,844 No. of Floors: 1 Year Built: 1963 Type of Use: Lounge and dining area open all night for snacks Steam Water-cooled condenser, 50-Ton York unit with a 6 cylinder-reciprocating
Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot
Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot Craig Selover Selover Consulting [email protected] H:248 542-3010 C:248 917-1380 Floor Plan Floor Plan All Piping WaterSense,HERS,
Heat Recovery and Compressed Air Systems
Heat Recovery and Compressed Air Systems By Frank Moskowitz for the Compressed Air Challenge Having a fundamental understanding of how your plant s compressed air system works and what forces influence
Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk
Solid Fuel Association Guide to Central Heating Link-Up Combining solid fuel with other central heating technologies using various methods ranging from a simple link-up to a fully integrated thermal store
Installation Questions
Installation Questions How do I determine what type of heat I have? There may be several ways to determine what type of heat you have. First, if you can access the unit that is responsible for creating
NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS
RHEEM CONTINUOUS FLOW GAS HOT WATER REVISED MAY 2013 GAS 6 ENERGY RATING 1-6 PERSONS 12-54 L/MIN CAPACITY 10 YEAR WARRANTY 3 NOW 6 STAR EFFICIENT HOT WATER THAT NEVER RUNS OUT factor COMES ON STEADY, HOT
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
Laundromat saves with hot water recycler
Laundromat saves with hot water recycler By REBECCA BROWN COURIER STAFF LITTLETON To Ed Zuk, saving hot water is like putting money in the bank. His Littleton Easy Wash on Pleasant Street is the first
GEOTHERMAL HEATING APPLICATIONS FOR RESIDENTIAL HOMES
GEOTHERMAL HEATING APPLICATIONS FOR RESIDENTIAL HOMES GAGNON HEATING & AIR CONDITIONING RT. 302, P.O. BOX 814 BRIDGTON, ME 04009 207-647-8782 mainegeothermal.com GOODWIN WELL & WATER, INC. 2282 AUBURN
HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?
WHAT IS A BTU? The standard energy measurement is the BTU (British Thermal Unit). Each BTU unit is determined by the amount of thermal energy required to raise the temperature of one pound of water by
Morco House Riverview Road Beverley HU17 0LD
Morco House Riverview Road Beverley HU17 0LD Morco Products Ltd Tel: 01482 325456 Fax: 01482 212869 Email [email protected] Web www.morcoproducts.co.uk Combi Boilers - Poor Hot Water Delivery Combi
Rainwater Harvesting
Rainwater Harvesting With climate change now a reality rather than a speculated possibility, the demand on water resources has gone up, whilst the amount of water available for supply has gone down. Forth
Cost Estimation for Materials and Installation of Hot Water Piping Insulation
Cost Estimation for Materials and Installation of Hot Water Piping Insulation Prepared for Pacific Northwest National Laboratory Under Contract Number: 18O9O2 By Gary Klein, Managing Partner Affiliated
Thermo Siphon Solar Systems
Thermo Siphon Solar Systems Thermo Siphon Solar Systems are a very cost effective way of producing hot water due to their simplicity in design and installation requirements. Usually more common in hotter
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
Solar Thermal TECHNOLOGY. Eric Buchanan Renewable Energy Scientist West Central Research and Outreach Center Wcroc.cfans.umn.edu
Solar Thermal TECHNOLOGY Eric Buchanan Renewable Energy Scientist West Central Research and Outreach Center Wcroc.cfans.umn.edu Solar Energy History Solar Thermal 700 BC Chinese use burning mirrors 1760
Ground Source Heat Pumps The Fundamentals. Southington, Connecticut 860 628 4622 John F. Sima III P.E.
Ground Source Heat Pumps The Fundamentals Southington, Connecticut 860 628 4622 John F. Sima III P.E. Winter/Spring 2010 Ground Source Heat Pumps The Fundamentals TOPICS: Heat Pump Terminology Basic Physics
How To Improve Energy Efficiency In A Data Center
Google s Green Data Centers: Network POP Case Study Table of Contents Introduction... 2 Best practices: Measuring. performance, optimizing air flow,. and turning up the thermostat... 2...Best Practice
HVAC Processes. Lecture 7
HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump
OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)
OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12) Revision 1.0 Page 1 of 50 THE INFORMATION CONTAINED IN THIS DOCUMENT IS THE SOLE PROPERTY OF INTERNATIONAL THERMAL RESEARCH, LTD. ANY REPRODUCTION
UNDERSTANDING CENTRAL HEATING SYSTEMS
UNDERSTANDING CENTRAL HEATING SYSTEMS This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential basic
Energy Efficiency HOSPITALITY. www.energia.ie
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
SERIES 12-600 VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE
Eemax Inc., 353 Christian Street, Oxford, CT 06478 1 E ema X SERIES 12-600 VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE WARNING
Sea Water Heat Pump Project
Sea Water Heat Pump Project Alaska SeaLife Center, Seward, AK Presenter: Andy Baker, PE, YourCleanEnergy LLC Also Present is ASLC Operations Manager: Darryl Schaefermeyer ACEP Rural Energy Conference Forum
01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09
0000-00 01-3 6810-20 1. FFH SPECIFICATION 01-4 0000-00 2. SYSTEM LAYOUT AND COMPONENTS 0000-00 01-5 01-6 0000-00 3. FFH GENERAL INFORMATION The system is to increase the coolant temperature quickly by
I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit
I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit IMPORTANT: These installation instructions are meant to be used as a guide for woodstove owners and
Description of functions
Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the
A COMPARISON OF WATER LEAK DETECTION AND SHUTOFF SYSTEMS
A COMPARISON OF WATER LEAK DETECTION AND SHUTOFF SYSTEMS By Charles Ergle January 16, 2012 As every appraiser knows, water damage is the single highest continual source of claims at Chubb. Fires happen,
HEAT RECOVERY FROM CHILLED WATER SYSTEMS. Applications for Heat Reclaim Chillers
HEAT RECOVERY FROM CHILLED WATER SYSTEMS Applications for Heat Reclaim Chillers April 2008 TABLE OF CONTENTS INTRODUCTION... 3 WASTE HEAT SOURCES... 3,4 Capturing Sufficient Heat for Useful Purposes...
Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED
High Efficiency Condensing Boilers Proven Reliability, American-Made Home Heating Comfort. Look for this logo throughout this literature to see the unique features that set U.S. Boiler Company apart from
Heat and Temperature: Front End Evaluation Report. Joshua Gutwill. October 1999
Heat and Temperature: Front End Evaluation Report Joshua Gutwill October 1999 Keywords: 1 Heat and Temperature Front End Evaluation Report October 28, 1999 Goal:
Lessons Learned, Best Practices and Observations. 2014 2016 Plant Winterization Visits
Lessons Learned, Best Practices and Observations 2014 2016 Plant Winterization Visits EQUIPMENT PROTECTION: Although some of the observations and practices were unique to an entity, the following can be
Quik Lining Systems Heater Owners Guide
Quik Lining Systems Heater Owners Guide Quik Lining Systems, Inc is pleased to present the Quik Heater, an innovative heater used to cure cured in place pipe for sewer laterals. The unit is the most cost
Energy Efficiency, Let s Save Energy!
, Let s Save Energy! Instructor Guide Subject Area Unit Grade Time Science Earth Science K -1st grade 45 minutes Overview This lesson presents various ways to the student can save energy in their home
E-gas Instant Gas Water Heaters
The Proven Preferred Choice! E-gas Instant Gas Water Heaters Training & Information Manual: There are important functional and operational differences between the conventional hot water geyser and the
HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS
HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS INTRODUCTION 1. There are no general EU regulations and standards for outdoor swimming pool heating. Local regulations in the member countries are covering most
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
SOLAR ENERGY FUNDAMENTALS
Radiantec SOLAR ENERGY FUNDAMENTALS G E N E R A L S U P P L E M E N T 420 by Radiantec Company What is Solar Energy? What is the Sun? The sun is a star, not much different from the billions of others in
High kw Electric Tankless Water Heater Troubleshooting Guide
Technical Service Bulletin High kw Electric Tankless Water Heater Troubleshooting Guide Models: WH17, WH27, WH36 AE115, AE125, (FD108 and higher) DANGER: ELECTRIC SHOCK ELECTRICITY IS EXTREMELY DANGEROUS.
BoilerMate SP. benchmark. user instructions A - C L A S S
A - C L A S S BoilerMate SP user instructions benchmark TM The code of practice for the installation, commissioning & servicing of central heating systems In the interest of continuously improving the
Hybrid (Dual Fuel) - Gas Heat and Air Source Heat Pump
s.doty 10-2014 White Paper #30 Hybrid (Dual Fuel) - Gas Heat and Air Source Heat Pump System Switches Fuels Automatically for Economy. What is an Air-Source Heat Pump? A heat pump is a modified air conditioning
Your guide to heating your home
Your guide to heating your home The average household could save 250 by being more energy efficient around the home. (Source: Energy Saving Trust) Why it pays to save energy It s perfectly natural to want
Laddomat 21-60 Charging unit
Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the
RESEARCH HIGHLIGHT. Performance Assessment of a Cold-Climate Air Source Heat Pump
RESEARCH HIGHLIGHT December 2014 Technical Series 14-102 Performance Assessment of a Cold-Climate Air Source Heat Pump INTRODUCTION Most Canadians are familiar with air source heat pump technology in the
HYDRONIC DESIGNER / INSTALLER MODULE DESCRIPTIONS
HYDRONIC DESIGNER / INSTALLER MODULE DESCRIPTIONS PIP301: Blueprint Reading This module covers the basic skills required for interpreting information provided by drawings. These skills are essential in
CERT. TO ASSE STD 1016 AND 1017 1016 AND 1017 1016 AND 1017 WT. LBS.
SUBMITTAL DATA/INSTRUCTION SHEET SD/IS 150 EFFECTIVE September 004 Supercedes March 3, 004 AM-1 SERIES TM ANTI-SCALD PROPORTIONAL THERMOSTATIC MIXING DIVERTING VALVE PATENTED, WITH DUAL ASSE 10 CERTIFICATION,
REGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
Preventing Overheated Boiler Incidents
Preventing Overheated Boiler Incidents PSE&G Appliance Service October 2012 Runaway Boiler Explosion Review Items Hazard Background Past Incidents PSE&G Emergency Response Future Process Improvements What
The Truth about Tankless Water Heaters Courtesy of the Cooperative Research Network
STA January 2010 CRN Consumer Product Review Word Count: 915 The Truth about Tankless Water Heaters Courtesy of the Cooperative Research Network Many homeowners have seen advertisements for tankless water
What you can expect from your Solar Hot Water System
Owner s Manual Your Solar Hot Water System Thank you for your investment in the FAFCO Solar Hot Water System. Since 1969 our goal has been to design, test, and produce solar heating systems that save you
