Coupled Inductors. Introducing Coupled Inductors

Similar documents
EE 221 Circuits II. Chapter 13 Magnetically Coupled Circuits

Series and Parallel Resistive Circuits

Nodal and Loop Analysis

Outline. Systems and Signals 214 / 244 & Energy Systems 244 / 344. Ideal Inductor. Ideal Inductor (cont... )

Transformer circuit calculations

Edmund Li. Where is defined as the mutual inductance between and and has the SI units of Henries (H).

Eðlisfræði 2, vor 2007

ES250: Electrical Science. HW7: Energy Storage Elements

Inductors & Inductance. Electronic Components

Chapter 12: Three Phase Circuits

Mutual Inductance and Transformers F3 3. r L = ω o

Chapter 11. Inductors ISU EE. C.Y. Lee

Last time : energy storage elements capacitor.

EE301 Lesson 14 Reading: , , and

Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49

Motor Fundamentals. DC Motor

How To Understand And Understand The Theory Of Electricity

DC-DC Converter Basics

12. Transformers, Impedance Matching and Maximum Power Transfer

13 ELECTRIC MOTORS Basic Relations

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Introduction to Electricity & Magnetism. Dr Lisa Jardine-Wright Cavendish Laboratory

Objectives. Capacitors 262 CHAPTER 5 ENERGY

EMI and t Layout Fundamentals for Switched-Mode Circuits

The Flyback Converter

Induced voltages and Inductance Faraday s Law

ELECTRODYNAMICS 05 AUGUST 2014

Application Note. So You Need to Measure Some Inductors?

Slide 1 / 26. Inductance by Bryan Pflueger

Current Ripple Factor of a Buck Converter

98% Efficient Single-Stage AC/DC Converter Topologies

Coupling Magnetic Signals to a SQUID Amplifier

Inductance. Motors. Generators

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Components. Transformers

1. The diagram below represents magnetic lines of force within a region of space.

RLC Resonant Circuits

An equivalent circuit of a loop antenna.

8 Speed control of Induction Machines

Unit 6 Transformers. Lead-in. Basic principles. Task 1. Task 2. What applications of transformers do you know?

3-Phase AC Calculations Revisited

Chapter 14: Inductor design

The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law.

Power measurement in balanced 3 phase circuits and power factor improvement. 1 Power in Single Phase Circuits. Experiment no 1

Common Mode and Differential Mode Noise Filtering

Transformer Calculations

12. The current in an inductor is changing at the rate of 100 A/s, and the inductor emf is 40 V. What is its self-inductance?

The generation and supply of electricity within the U.K is achieved through the use of a 3-phase system.

Magnetic Field of a Circular Coil Lab 12

Application Note on Transformers (AN )

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

Diodes have an arrow showing the direction of the flow.

Chapter 30 - Magnetic Fields and Torque. A PowerPoint Presentation by Paul E. Tippens, Professor of Physics Southern Polytechnic State University

Chapter 24. Three-Phase Voltage Generation

Linear DC Motors Magnetic Flux Permanent Bar Magnets

30. Bode Plots. Introduction

Module 22: Inductance and Magnetic Field Energy

G019.A (4/99) UNDERSTANDING COMMON MODE NOISE

Inductors. AC Theory. Module 3

Chapter 15: Transformer design

Power supplies. EE328 Power Electronics Assoc. Prof. Dr. Mutlu BOZTEPE Ege University, Dept. of E&E

Transmission Line Transformers

April 1. Physics 272. Spring Prof. Philip von Doetinchem

Lecture 24. Inductance and Switching Power Supplies (how your solar charger voltage converter works)

PHASOR DIAGRAMS HANDS-ON RELAY SCHOOL WSU PULLMAN, WA. RON ALEXANDER - BPA

Inductors. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Capacitors in Circuits

Full representation of the real transformer

AC Generators. Basic Generator

Chapter 30 Inductance

Line Reactors and AC Drives

Equipment: Power Supply, DAI, Transformer (8341), Variable resistance (8311), Variable inductance (8321), Variable capacitance (8331)

45. The peak value of an alternating current in a 1500-W device is 5.4 A. What is the rms voltage across?

Scott Hughes 7 April Massachusetts Institute of Technology Department of Physics Spring Lecture 15: Mutual and Self Inductance.

1 Introduction. 2 Two Phases. J.L. Kirtley Jr.

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Three phase circuits

Phasors. Phasors. by Prof. Dr. Osman SEVAİOĞLU Electrical and Electronics Engineering Department. ^ V cos (wt + θ) ^ V sin (wt + θ)

Basics of Electricity

Drive circuit basics + V. τ e. Industrial Circuits Application Note. Winding resistance and inductance

Module P4.4 Electromagnetic induction

THE PER-UNIT SYSTEM. (2) The per-unit values for various components lie within a narrow range regardless of the equipment rating.

Chapter 16. Current Transformer Design. Copyright 2004 by Marcel Dekker, Inc. All Rights Reserved.

W03 Analysis of DC Circuits. Yrd. Doç. Dr. Aytaç Gören

Homework # Physics 2 for Students of Mechanical Engineering

(3 )Three Phase Alternating Voltage and Current

Impedance Matching. Using transformers Using matching networks

AC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Building the HVPS High Voltage Power Supply

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT

Single Transistor FM Transmitter Design

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

Unit 33 Three-Phase Motors

Alternating Current Circuits and Electromagnetic Waves

Selecting IHLP Composite Inductors for Non-Isolated Converters Utilizing Vishay s Application Sheet

Alternating Current and Direct Current

The full wave rectifier consists of two diodes and a resister as shown in Figure

Chapter 12 Driven RLC Circuits

Understanding SMD Power Inductors. Application Note. July 2011

Transcription:

Coupled Inductors From power distribution across large distances to radio transmissions, coupled inductors are used extensively in electrical applications. Their properties allow for increasing or decreasing voltage and current, transferring impedance through a circuit, and they can isolate two circuits from each other electrically. There are a wide variety of applications which exploit properties of transformers, such as tesla coils, impedance matching in audio frequency applications, potential transformers for reading very high voltages, Scott-T transformers which convert twophase components to three-phase (or vice versa), and many more. This module explains the functions of coupled inductors and explores the equations governing their performance. It will present mutual inductance, dot notation, the coupling coefficient, the turns ratio, and finally the ideal transformer. This module will explain how to model coupled inductors and provide modeling examples in MapleSim. Introducing Coupled Inductors As current flows through a conductor, a magnetic field is generated. Steady-state current

will induce a steady magnetic field, and likewise a time-varying current will induce a timevarying magnetic field. Nearby conductors will generate a current as the varying magnetic flux permates the conductor, as stated by Faraday's law. This principle is known as inductance. To begin investigating coupled inductance, recall that the voltage across an inductor is proportional to the change in current. L is the inductance of the conductor, in henry's.... Eq. (1) Figure 1: Two coils are magnetically coupled, wound around a magnetic core. With coupled inductors, such as those shown in figure 1, two wires are wrapped around a magnetic core. In this diagram, note that the two wires are wrapped around the core in opposite directions and produce the same polarity of voltage. This is due to Lenz's law. A varying magnetic field, generated by the current, will induce a current in the opposite direction on the coupled coil. Heinrich Lenz added the negative sign to Faraday's law of induction, below. Here, is the change in magnetic flux and is the electromotive force.... Eq. (2)

The flux within the magnetic core of the coupled inductors depends on the material of the core, the number of turns of the wire around the core, and the current. The voltage across the inductor is related to the flux by the number of turns of the coil.... Eq. (3) This shows that we can draw a connection between eq. (1) and eq. (4).... Eq. (4)... Eq. (5) The voltage across the second inductor follows eq. (4). The magnetic flux will be the same (as induced by the first coil), and we derive and equation for the mutual inductance.... Eq. (6) The variable M is the mutual inductance of the system, in henrys. This depends on the geometrical properties of the coils, such as the number of turns and radii of the turns of each coil.... Eq. (7) A dot convention is used to specify the direction of the windings around the core. Dots on the same ends of the inductor, like in figure 1, mean that the coils are wrapped clockwisecounterclockwise to each other. If the dots are on the opposite sides like figure 2 shows, then the coils are wrapped in the same directions (clockwise-clockwise or counterclockwisecounterclockwise).

Figure 2: Coupled inductor with dot notation It's important to note that the dot convention follows passive convention. Although figure 2 displays the voltages as the same polarity, one of the voltages will be negative. The dot convention states: If the current enters the dotted terminal of one coil, the voltage will be positive at the dot on the second coil. Similarly, the voltage of the second coil will be negative if the current leaves the dotted terminal of the first coil. Figure 3 illustrates the passive convention.

Figure 3: Induced voltage of coupled inductors. This voltage is the voltage induced by the coupled current. A transformer can have current entering from both the first and second coils. The voltage across each coil will be dependant on the current through this coil and the induced voltage from the other coil. Suppose the dots are on the same end, and both currents enter at the dots. The voltages will be, and If the dots are on the opposite sides of each other, then the voltages will be,... Eq. (8) and... Eq. (9) Because the induction relies on a changing current, coupled inductors must be used with alternating current. This means that we can analyse coupled inductors in the frequency

domain as phasors. Eq. (8) and eq. (9) can be represented with phasors as eq. (10) and eq. (11), respectively. and... Eq. (10) and The Coupling Coefficient... Eq. (11) The coils and mutual inductances depend on material properties of the core. The factor c used represents these properties in a lumped product. Explicity, c is the product of the permeability of free space and the core, the cross-sectional area, and the inverse of the length of the coils.... Eq. (12) From eq. (5) and eq. (7), the mutual inductance is related to the coils inductances by However, this assumes a perfect flux linkage between the two conductors.... Eq. (13) Figure 4: Flux lines cutting through the coils. Some flux lines will not cut through the coupled inductor, which will affect the mutual inductance. Therefore, eq. (13) is multiplied by the coupling coefficient k, a value between 1 (perfectly linked inductors) and 0 (uncoupled inductors). Eq. (13) becomes

... Eq. (14) A coupling coefficient of 0.75 can imply that 75% of the flux lines cut through the other inductor. Different applications try to achieve different coupling coefficients, for example radio circuits will result in low k values and many power system transformers aim for k = 1. Ideal Transformers Turns Ratio and Step Transformers The primary coil in a transformer is the coil connected to the source voltage. The secondary coil is attached to the load of the circuit. The turns ratio is the ratio of some value of the second coil to the first. The turns ratio is defined as... Eq. (15) Where V is the voltage of the transformers at each coil, I is the current, N is the number of turns of each coil, and L is the inductance of the coils. The turns ratio determines whether a transformer will step-up or step-down. A transformer that steps-up the voltage, that is the secondary voltage is greater than the primary voltage, will also step-down the current. Conversely, stepping down the voltage will increase the current on the secondary coil. a)

b) Figure 5: a) Step-up transformer, b) Step-down transformer The voltage of the secondary inductor can then be found with this ratio, and it is related to the primary voltage.... Eq. (16) One big advantage to AC electricity is that it can travel across large distances more efficiently than DC electricity. Power companies use transformers to step-up the voltage as electricity leaves the power plant. Once it arrives at the customer's house, a step-down transformer reduces the voltage down to 110 V or 220 V and increases the current. In these application, it is ideal that the coupling coefficient be as high as possible to reduce lost energy. The ideal transformer is a transformer which has a coupling coefficient equal to 1 (unity). The important factor in an ideal transformer is the turns ratio, which determines the magnitude of the step. They are used to raise and lower voltage and for isolating circuits from each other.

Figure 6: An ideal transformer An ideal transformer does not absorb or store any electrical power while in operation. All of the power delivered to the primary coil will be directly delivered to the secondary coil. The sum of the power within the elements is zero. Consider the circuit in figure 7 with an ideal transformer. Figure 7: A source circuit and load circuit connected with an ideal transformer The impedance on the source circuit will be Find the equivalent values of the current and voltage of the load circuit.... Eq. (17)

and Substitute this into eq. (17).... Eq. (18) Simplifying this shows a relation between the source impedance and load impedance.... Eq. (19)... Eq. (20) This shows that the source experiences an impedance equivalent to the scaled impedance of the load. We can draw an equivelent impedance at the transformer, given the impedance from the load. Formally in the frequency domain, this is represented as... Eq. (21) Modelling Transformers Transformers can be represented where inductive coupling is unavailable with the use of dependent voltage or current sources. Generally, coupled inductors as shown in figure 8 can be modelled as shown in figure 9.

Figure 8: Coupled inductors Figure 9: Inductors coupled via dependent voltage sources. This circuit will behave the same way as coupled inductors function. Similarily, ideal transformers can be represented with dependant sources.

Figure 10: Ideal transformers represented through dependant voltage and current sources. Examples with MapleSim Example 1: Voltage Across Coupled Inductors Example 2: Calculating Power in a Transformer Circuit References: R. Dorf, J. Svoboda. "Introduction to Electric Circuits", 8th Edition. RRD Jefferson City, 2010, John Wiley and Sons, Inc. Veluvolu, K. (n.d.). "Magnetically Coupled Circuits" [PDF Document]. Retrieved online from http://m80.knu.ac.kr/~veluvolu/lecture_notes/ct2/magneticckts.pdf