Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM



Similar documents
Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

Chapter 7: Sandwich Valves

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

KDG3V-5/7/8, 10 Series

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY /US

Chapter 5: Flow Valves

Check Valves Valve locator

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Bulletin 2537-M4/USA Service Bulletin Series CPOM

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Series PVP Variable Volume Piston Pumps

Variable Displacement Pump AA10VSO

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Pressure reducing valve, direct operated, Type ZDR 6 D

Denotes New Winner s Circle Product Line. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Pneumatic Grippers Parallel and Angular Grippers. Catalog /US

2-way flow control valve Type 2FRM 6

Pressure relief valves Size 6

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Vickers Vane Pumps Single and Double Vane Pumps. Model Series V10, V20, V2010, and V2020 for Industrial Equipment

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

PVH131/141 Variable Displacement Piston Pump - 11 Design

PUMP AND MOTOR DIVISION

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

Spool Center Condition * Orifice Closed Open 2-Position Soft Shift Size Voltage Energize De-Energize Energize De-Energize Energize De-Energize

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Solenoid Operated Directional Valves

Hydraulic Flow Control Valves

Solenoid Operated Directional Valves

Pressure Relief. Pressure Relief Valves. Vickers

SystemStak. SystemStak Valves. Vickers

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

15/40/80CN Series Coreless Medium Pressure Filters

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V

Vickers Vane Pumps V Series - Low Noise Vane Pumps. High Performance Intravane Pumps For Industrial Applications

005 SERIES MODULAR VALVES. Pub. EC General Information Up to 25 MPa (3630 PSI), 10 L /m in (2.6 U.S.GPM) Modular Valve Type

15/40/80CN Series Medium Pressure Filters

HMC Series Dual Displacement Staffa Motor

Char-Lynn Hydraulic Motors. Repair Information. W Series Geroler Motors 002, 003. April, 1999

3/2- and 2/2-way cartridge valve type BVE

Pressure Relief and Regulating Valves

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

Flow Control (and Check) Valves FG FCG -01/02/03/06/10. Specifications / Model Number Designation / Others. Min. Metred Flow Capacity

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

LINEAR MOTION CONTROL

Char-Lynn Disc Valve Motors. Parts Information Compact Series

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

1.Booklet. Hydraulic Motors. General Purpose MotorsR Series

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

Float and Thermostatic Traps Series H, C and X

Series TMM Axial Piston Motor. Technical Information

Quiz On Information Learned From Chapter 1

PVM Piston Pumps Service Manual

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY CD/US

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

HYDRAULIC MOTORS Concentric AB

Proportional Pressure Reducing Valves

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Pressure Relief Valves SPV, SPVF

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY CD/US

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Reusable contamination basket prevents loss of retained contaminants into the reservoir during element replacement.

Unit 24: Applications of Pneumatics and Hydraulics

NORMAN FILTER COMPANY PRODUCT OVERVIEW

Vickers. Piston Pumps

3/2 Solenoid Cartridge Valve, Size 6

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division

Valve systems Base plates, according to standard ISO Brochure

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

Oil Pressure Regulating Valve

4 Posiflow Proportional Solenoid Valves

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

Chapter 6: Check Valves

HYDRAULIC MOTORS HYDRAULIC SYSTEMS DIVISION. Outstanding Hydraulic Products, Service and Expertise, Worldwide

Rexroth Hydraulic Pump A10VO Series User Manual

Vickers. Overhaul Manual. Relief Valves. Balanced Piston Relief Valves. CG/CS/CS5-03/06/10 Series CT/CT5/CG5-06/10 Series

IMPORTANT DOCUMENTATION DO NOT DISCARD!

SAFETY BLOCK type BS 9.3 E 01-12

Table of Contents. M Series Variable Displacement Piston Pumps

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

Electro-hydraulic pressure switches type DG

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

Proportional Pressure Relief Valves

THE SIMPLEX HAND PUMP

SureSite Magnetic Liquid Level Indicator

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

DT Series. Features FLOW. DT-MFMO Male Flare 37 JIC Inlet to Male O-Ring Boss Outlet. DT-MSMO Male Seal-Lok Inlet to Male O-Ring Boss Outlet

Transcription:

Introduction Manapak valves provide a variety of check, flow control, pressure relief and pressure reducing functions in a compact NFPA D03, D05 and D08 sandwich style valve. The NFPA D03 valve body conforms to the ISO 40 mm (1.57") thickness. These valves are mounted between directional control valves and their mounting surface. Check Valves Series CM provide extra strength and durability for Positive shut-off is provided by a fully guided poppet and allows full flow in the unchecked position. Parker Manapak CM sandwich style check valves can be used either on the 'P', 'A', '', 'T' port or combination. Large internal flow paths allow high flow at low pressure drop. The NFPA D03 Manapak valves may also be used in conjunction with Parker's Cartpak Series of sandwich valves which offer a wide variety of additional functions including relief, pressure reducing/relieving, load check, back pressure check, needle, flow control, pressure compensated flow control, crossover, relief and directional valves. CM*AA CM* CM*AAF CM*F CM*DD CM*DDF CM*PT CM*PP CM*TT P. O. Check Valves Series CPOM Parker Manapak CPOM sandwich style, pilot operated check valves can be provided in either single or double configurations. The pilot operated checks may be positioned in 'A' port or '' port; or both 'A' and '' ports. provide extra strength and durability for Positive shut-off is provided by a hardened poppet and cage assembly. Large internal flow paths allow high flow at low pressure drop. CPOM*AA CPOM*DD CPOM* 2502-1.p65, dd 2

Introduction Flow Control Valves Series FM Parker Manapak style FM flow control valves can be provided in either single or double configurations. The flow controls may be positioned in 'P' port, 'A' port, '' port, or both 'A' and '' ports. provide extra strength and durability for Two step needles (standard) provide fine adjustment for the first three turns and course adjustment for the last three turns. Fine metering needles are available as an option. Large bypass checks allow high flow at a low pressure drop. Reversible (invert 180 ) for meter-in or meter-out (D03 & D05 only). FM*AA (Meter Out) FM* (Meter Out) FM*DD (Meter Out) FM*PP (Meter Out) Pressure Reducing Valves Series PRDM PRDM Manapak sandwich valves may be selected to reduce pressure in the 'P' port, 'A' port or '' port. The direct operated, cushioned piston design results in fast response, low leakage and minimal hysteresis. Up to four pressure adjustment ranges are available with maximum pressure settings of 25, 64, 160 and 210 ar (363, 928, 2320, 3045 PSI). Adjustment options include: internal hex screw, hand knob or internal hex with keylock. Fluorocarbon seals are standard for multi-fluid compatibility. Available gage port connections include: SAE, NPT, SPP Metric and ISO 6149. PRDM*PP PRDM*AA PRDM* T P A M T P A M T P A M 2502-1.p65, dd 3

Catalog HY14-2502/US Introduction Pressure Reducing Valves Series PRM Parker Manapak PRM sandwich style pressure reducing valves can be used to reduce pressure on the 'P' port, the 'A' port, or the '' port. Three pressure adjustment options available: slotted screw, knob and locking knob. provide extra strength and durability for PRM*AA PRM* PRM*PP Pressure Relief Valves Series RM Parker Manapak RM sandwich style relief valve is a 'P' port to 'T' port relief. provide extra strength and durability for Three pressure adjustment options available: slotted screw, knob and locking knob. RM*PT 2502-1.p65, dd 4

Dimensions Series CM2 Inch equivalents for millimeter dimensions are shown in (**) 7.0 (0.28) 14.5 (0.57) T 45.0 (1.77) A P Top View 70.0 (2.76) 40.0 (1.57) 38.8 (1.53) 3.2 (0.13) Face View 3.2 (0.13) P A T SHOWN WITHOUT O-RING PLATE ottom View Note: Transfer the locating pin to the hole on the opposite side of the valve body for 'T' port option. (Invert body 180 ) 2502-1.p65, dd 7

Surface Patterns ottom Views Series CM2 Top Views TT PP/PT DD DDF F AA AAF 2502-1.p65, dd 8

Catalog HY14-2502/US Installation Information CAUTION: Manapak Installation Prior to installation of Manapaks, please review flow paths. Due to the reversibility of the DO3 size, incorrect installation will alter the hydraulic circuit. Care must be taken during installation to insure that the Manapak is installed in compliance with the hydraulic schematic. Please consult with your Parker representative with any questions that may arise. Pressure Ratings Unless otherwise specified, all Parker Manapaks have continuous duty pressure rating as shown in this catalog. Special Requirements Consult your Parker representative for factory recommendations on such situations as: Installations that will operate at pressures higher than published catalog ratings. Use of hydraulic fluids which do not meet our recommended specifications. Operations where fluid temperature will exceed 121 C (250 F). Recommended Mounting Surface Surface must be flat within.0004 inch T.I.R. and smooth with 32 micro-inch. System Cleanliness Any hydraulic system that includes Parker valves should be carefully protected against dirt and fluid contamination. Life of the valves, as well as of all other components, will be greatly lengthened. Operation will be smoother and more precise. Maintenance and repairs will be reduced. Lost production because of low pressure and flow will be minimized. Fluid contamination should be maintained to less than 500 particles larger than 10 micrometers per milliliter of fluid (SAE class 4 or better/iso Code 16/13). Hydraulic Fluids Parker recommends using top-quality hydraulic fluids having a viscosity range of 150 to 250 SSU (32 to 54 cst.) at 38 C (100 F). The absolute viscosity range should be 80 to 1000 SSU (16 to 220 cst.). Fluids should have highest anti-wear characteristics and be treated to avoid rust and oxidation. Seals When used with water-glycol, water/oil emulsions, and high-grade petroleum base hydraulic fluids, Parker standard nitrile seals are suitable. When using phosphate ester fluids or their blends, specify Parker optional seals made of fluorocarbon. Synthetic fire-resistant fluids require special seal materials which your Parker representative can recommend. Torque Specifications The recommended torque valves are for the bolts which mount the valve to the manifold or subplate are as follows: Size Torque Valve 2 5.7 N.m. (50 in.-lbs.) 3 16.3 N.m. (12 ft.-lbs.) 6 108.5 N.m. (80 ft.-lbs.) 2502-1.p65, dd 42

Installation Information Mounting Patterns Mounting Surface for Directional Control Valve Manifold M'TD. (NFPA, D03); CETOP 3 & NG 6 21.4 (0.84) 50.8 (2.00) 27.0 (1.06) 6.4 (0.25) 54.0 (2.13) 37.3 (1.47) 16.7 (0.66) 3.2 (0.13) - - 91.2 (3.59) 75.0 (2.95) 46.0 (1.81) - A - 32.5 (1.28) T A P T O 11.2 (0.441) max. P.A.. & T ports 0.56 L (0.022) A ¼ 20UNC 2(M6x1)th'd x 9.7 (0.38) min. th'd depth 4 places 0.28 S (0.011) A Mounting Surface for Directional Control Valve (NFPA, D05); CETOP 5 & NG 10 2502-1.p65, dd 43

Installation Information Series CM, CPOM, FM, PRM, RM Mounting Patterns Mounting Surface for Directional Control Valve (NFPA, D08); CETOP 8 & NG 25 2502-1.p65, dd 44