Understanding BS EN 771-3: Aggregate concrete masonry units



Similar documents
Dubai Municipality Standard DMS 1: Part 5: 2004

Composite Panel Firewall Systems

PRODUCT GUIDE lower tolerances high quality

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

THE DEVELOPMENT OF DESIGN METHODS FOR REINFORCED AND UNREINFORCED MASONRY BASEMENT WALLS J.J. ROBERTS

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Technical Notes 3B - Brick Masonry Section Properties May 1993

EDUCATIONAL GUIDE TO PROPERTIES OF MASONRY MORTAR

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

PRODUCT GUIDE. Building the future with Ytong autoclaved aerated concrete. low tolerances high quality

European Technical Approval ETA 13/0384

GRC Porticos. Lightweight entrance porticos ABBEY ARTSTONE

European Technical Approval ETA 13/0526

Guide for SOLID CONCRETE BLOCK SEALS

Poro Lintel System Range Unique to the Porotherm & thin joint masonary systems

ADVANTAGES OF MODULAR LAYOUT

European technical approval

Introduction. Eurocodes. Specification. Cost

European technical approval

The BASA Guide to the ISO Classification of Sealants for Building Construction

Rockwool Flexi Insulation Application Guide

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Product Data Sheet ROCKPANEL Rockclad

EXPERT OPINION on the applicability of the construction technology "GRÈMOUND non-tectonic system on grounds of the documentation submitted

Mold Preventing I nterior System

LAYING BLOCK AND BRICK

Chapter 2 Basis of design and materials

Mandate M/116 MASONRY AND RELATED PRODUCTS

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

September Joint

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

SmartPly OSB3 SMARTPLY

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking

Guidelines for Earthquake Bracing Residential Water Heaters

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Authorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December 1988 on the

3 Masonry and Manufactured Stone (Interior and Exterior)

European Organisation for Technical Approvals

GRADATION OF AGGREGATE FOR CONCRETE BLOCK

Rockwool Cladding Roll

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

EUROPEAN STANDARDS AND MARKINGS FOR HAND AND ARM PROTECTION

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

ICS: Strengthening retrofitting of reinforced concrete structures by gluing of fibre reinforced polymeric fabrics (FRP fabrics)

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2B Energy & IAQ (2009) Related TEK: 6-1B, 6-11, 6-12C INTRODUCTION

Section 5A: Guide to Designing with AAC

FIXIT.CH. Aerogel Insulating Plaster System. Handling Guidelines. Easy to use. Mineral based W/mK BAUSTOFFE MIT SYSTEM

Mineral fibreglass insulation

Sealfire W1000 Compound. (2 references for the same product) Fire Stopping and Sealing Product: Penetration Seals

Annex of the certificate (Page 1/6) Accreditation Scope

European Technical Assessment ETA-15/0652 of 27/10/2015

DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS

Division 2 Section Section 02795

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Eurocode 2: Design of concrete structures

POLYURETHANE FOAM CONCEPT

Fire and Concrete Structures

INTERIM ADVICE NOTE 96 /07 Revision 1 GUIDANCE ON IMPLEMENTING RESULTS OF RESEARCH ON BRIDGE DECK WATERPROOFING

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Gurit (UK) Ltd. Document Reference:

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

Detailing of Reinforcment in Concrete Structures

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

Loss Prevention Standard

A N Beal EARTH RETAINING STRUCTURES - worked examples 1

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Hanson Building Products. precast basement solutions

DECLARATION OF PERFORMANCE

Natural Thin Stone Veneer

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2C Energy & IAQ (2013) Related TEK: 2-5B, 6-1C, 6-4B, 6-11A, 6-12C, 6-12D, 6-12E

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Eco-Sol Ltd. Document Reference:

ETAG 004 EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS WITH RENDERING

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Guide to working on Public Sewers

Choosing the Right Mortar for the Job

HUNTON BITUMEN IMPREGNATED BOARDS HUNTON BITROC SHEATHING BOARD

Quality Regulations for Profiles

Hydrophobe VII., Lisbon

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

BETONYP building boards. The modern way of living.

Services Enclosures and Protected Shafts - Maintaining Compartmentation

How To Test For Premer Retardant

European Technical Assessment ETA-15/0028 of 23/02/2015

Light-Weight Panels. High quality panels.

Physically Crosslinked Foam Insulation

Baumit Renders for Porotherm Masonry. Application Guidelines. n Light and easy application n Tried and tested

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

Design of Masonry Structures According Eurocode 6. Prof. em. Dr.-Ing. Wieland Ramm Technical University of Kaiserslautern

Module 3.7. Thermal bridging

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

Multi-layer Insulation Blanket for Roofs

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

FLOORS REINFORCEMENT Shear Stud Connector for steel- concrete composite structures cold applied by pins

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Specification Guidelines: Allan Block Modular Retaining Wall Systems

Energy Company Obligation (ECO): Technical Monitoring Questions

Transcription:

60 Charles Street, Leicester LE1 1FB Tel: 0116 253 6161 Fax: 0116 251 4568 Email: enquiries@cba-blocks.org.uk Website: www.cba-blocks.org.uk February 2006 Understanding BS EN 771-3: Aggregate concrete masonry units Important guidance for specifiers and users on a new Standard for aggregate concrete blocks Introduction BS EN 771-3: Aggregate concrete masonry units (Dense and lightweight aggregates) is a new harmonized Standard for aggregate concrete bricks and blocks. It will replace BS 6073-1 in April 2006 after a 12-month period of co-existence. There is no doubt that over a period of 24 years BS 6073-1 has served our industry well in developing concise and unambiguous specifications for aggregate concrete bricks and blocks used in far ranging applications. Like most British Standards it has been necessary to adapt BS 6073-1 to suit an enlarged market as well as to reflect up to date materials testing and regulatory requirements. This Guide to BS EN 771-3: has been prepared to assist anyone involved in the design, specification and ordering of aggregate concrete blocks to understand the changes and thereby continue to make the specification and procurement of aggregate concrete blocks as straightforward as possible. Background BS EN 771-3 Aggregate concrete masonry units is written as a performance standard which means that all requirements are based on the finished product, rather than prescriptive standards which limit the materials that can be used in manufacture. Unlike BS 6073, BS EN 771-3 requires a manufacturer to conduct limited type testing and have a documented factory production control system. A third party to monitor the factory production control system is not essential. The test methods for the required properties are listed in BS EN 771-3. Some of these test methods are familiar but others are new. 1

Groupings of units are introduced. Categories of units are introduced. It contains a national foreword and a national annex, which between them explain the essential differences between BS 6073 and BS EN 771-3. Requirements Dimensions These have to be declared in the order: Length, width & height. (e.g. 440mm x 100mm x 215mm). This is an important distinction between the previous custom of specifying and ordering blocks based on dimensions in the order of length x height x width (thickness). BS EN 771-3 gives 4 tolerance classes (D1, D2, D3 & D4). Class D1 (+3, -5mm on all dimensions) is the most appropriate for common block applications. Tolerance D4 is intended solely for blocks to be laid with thin joint mortar, a technique rarely used in the UK. Closer tolerances on any dimension may also be declared by the manufacturer for any tolerance category. The test method for dimensions is BS EN 772-16. Configuration Reference is made to the requirements of the groupings of units used in the European Masonry Design Code (BS EN 1996-1-1). BS EN 1996-1-1 puts lower limits on: Shell thickness Web thickness but these limits are generally much lower than used in current UK designs and are normally easily complied with using current aggregate block products. BS EN 1996-1-1 also categorizes units according to void percentages as follows: Group 1 Group 2 Group 3 Group 4 < 25% formed vertical voids by volume > 25% < 60% formed vertical voids by volume > 25% < 70% formed vertical voids by volume > 25% < 50% formed horizontal voids by volume 2

See Annex A for full details of the requirements for unit groupings. Blocks currently described as solid will become Group 1 units. Cellular and hollow blocks will, depending on void content, will be described as Group 1 or 2 units. Group 3 and 4 units are not commonly manufactured for use in the UK. Configuration also covers flatness requirements for the faces of facing quality units only, and flatness requirements for the bed surfaces of units to be used with thin layer mortar in D4 tolerance category. There is also a requirement for the parallelism of bed faces of units to be used with thin layer mortar in conjunction with the D4 tolerance category. For facing units there is an optional but strongly recommended procedure for the site approval of the appearance of unit prior to their use. Density The gross dry density of the blocks has to be declared by the manufacturer. The standard also requires net dry density to be given when it is relevant to the application. The net dry density is rarely likely to be a necessity in practice. A density tolerance of + or 10% is allowed on both gross and net density. The appropriate test method is BS EN 772-13. The compressive strength will need to be declared air dry. The conditioning and surface preparation used need to be declared by the manufacturer. The appropriate test method is BS EN 772-1. Annex B gives new strengths referred to in Building Regulations and British Standards. These are slightly higher than strengths determined to BS 6073. The manufacturer will declare whether a unit is category I or category II. A category I unit would be approximately equivalent to special category as defined in BS 5628-1 and would require third party certification and monitoring of the production control system. Thermal properties In the UK, configuration and density is used primarily as the basis for the declaration of thermal properties. Manufacturers will still be allowed to give thermal resistance values of products using values from CIBSE Guide A. (For cellular/hollow units the thermal resistance can be calculated to BS EN ISO 6946 taking off the surface resistance values). 3

Durability Generally durability compliance criteria are to be found in BS 5628-3. Water absorption by capillarity Water absorption is only applicable to facing units with no applied finish. The appropriate test method is BS EN 772-11, (Clay and aircrete units use the same test method but using different procedures within the method and these will lead to test results for the products, which cannot be directly compared). Moisture movement This will now be declared to a new test method, which is a combination of drying shrinkage and wetting expansion. The appropriate test method is BS EN 772-14 (Aircrete is tested to BS EN 680 and this will lead to lower values which cannot be compared directly with results to BS EN 772-14). Water vapour permeability Tabulated values are likely to be declared in accordance BS EN 1745, BS 5250 & CIBSE Guide Book. If tested, values can be determined to BS EN ISO 12572. Reaction to fire (spread of flame) If the manufacturer uses materials that result in a unit containing more than 1% by mass or volume of organic material then he is responsible for the following tests to be carried out: BS EN ISO 1182 Reaction to fire tests for building materials. Non- combustibility test. BS EN ISO 1716 Reaction to fire test for building materials Determination of the heat of combustion. And the results need to be classified according to BS EN 13501-1. Shear bond strength A value of shear bond strength needs to be given and it is recommended that the tabulated value of 0.15 N/mm from Annex C of BS EN 998-2 is declared. (The tabulated value or a measured value is of no practical use as bond strength in practice will be dependent on a number of factors outside the control of the producer and a value could not be guaranteed as being universally applicable, but only for a set of specific conditions, which would be difficult to replicate on site). 4

Flexural bond strength This requirement only applies in Finland and therefore a value need not be given as there is no regulatory requirement for this property to be declared in the UK. Classification There are no classification systems for masonry units in the UK but there are in some EU countries. Marking It is anticipated that product identification details and means of identification of the date of manufacture will be given on delivery documentation and on the product where appropriate. 5

Annex A Groupings of concrete units from EN 1996-1-1 Volume of all holes (% of the gross volume) Group 1 (all materials) Limits for Masonry Units Group 2 Group 3 Group 4 Horizontal Vertical Holes Holes < 25 > 25; < 60 > 25; < 70 > 25; < 50 Volume of any hole (% of the gross volume) < 12,5 Each of multiple holes < 30 gripholes up to a total of 30 Each of multiple holes < 30 gripholes up to a total of 30 Each of multiple holes < 25 Declared values of thickness (b) of webs and shells (mm) No Requirement Web Shell Web Shell Web Shell > 15 > 18 > 15 > 15 > 20 > 20 Declared value of combined thickness (a) (b) of webs and shells (% of the overall width) No Requirement > 18 > 15 > 45 a) The combined thickness is the thickness of the webs and shells, measured horizontally across the unit at right angles to the face of the wall. The check is to be seen as a qualification test and need only be repeated in the case of principal changes to the design dimensions of units. b) In the case of conical holes, or cellular holes, use the mean of the thickness of the webs and the shells. 6

Annex B Compressive strength of units To BS 6073-1 To BS EN 771-3 2.8 2.9 3.5 3.6 5.0 5.2 7.0 7.3 10.0 10.4 Preferred higher unit compressive strengths BS 5628-1: 1992 BS 5628-2: 2000 15 20 35 BS 5628-1: 2005 BS 5628-2: 2005 (Not equivalent to 1992 & 2000 strengths) 17.5 22.5 30.0 40.0 To order a copy of the full standards please visit: www.bsonline.bsi-global.com 7