VD4. Vacuum circuit-breaker



Similar documents
30 ms High Speed Transfer System (HSTS) Product Description

IEC in ZX Gas-insulated medium voltage switchgear

DS1 Diode-based transient-free capacitor switch

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

UFES Active protection for switchgear

3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

VD4. Vacuum circuit-breaker 36 kv Instruction manual BA 434/03 E. ABB Power Distribution

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Medium voltage indoor circuit breakers ANSI/IEC solutions

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Disconnectors and Earthing Switches 36 kv up to 800 kv

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Siemens Fusesaver. Highest availability and cost savings for your MV distribution network.

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Hyperlinks are Inactive

Safe and secure distribution of medium voltage with AX1

Advantages of Fixed Circuit Breaker Switchgear

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Do s and don'ts of connection systems Are there any options when the clearance and creepage distances are not sufficient for UL 1059?

VD4 Vacuum Circuit-breaker. With Embeded Poles kv, A, kA Instruction Manual

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Safe and reliable distribution network ABB portfolio for medium-voltage indoor applications

Current and voltage measuring relays

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Comparison of GIS and AIS systems for urban supply networks

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

MNS is Switchgear System Technical Overview

Electronic overload relay EF65, EF96 and EF146

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

Rittal TopTherm fan-and-filter unit

Vacuum Circuit Breaker

8. Switchgear and switchgear installations for high voltage up to and including 52 kv (medium voltage)

The Intelligent AX1 Switchgear for Medium Voltage

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, HP

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Technical catalogue TK 503/01 E. ZX0.2 Gas-insulated medium voltage switchgear

Electronic overload relay EF19 and EF45

Protection from Short-circuit

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Redundancy Module QUINT-DIODE/40

Outdoor vacuum circuit-breakers and reclosers for medium voltage. Switching technology for distribution networks. Answers for energy.

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Erik Backström, High Voltage breakers, After Sales & Service High voltage SF 6 live tank circuit breakers After Sales & Service Training course

Low Voltage Products. Switches Automatic Transfer Switches

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

3K Load-Break Switches The Program for Safety and Performance. sentric

Guidelines for Packing

GE Energy Industrial Solutions

VM1. Vacuum circuit-breaker Instruction manual BA 504/02 E

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

ESS industry day Introduction to Imtech Power Conversion

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed

CERTIFICATE ISO 9001:2008 ISO 14001:2004 BS OHSAS 18001:2007. hereby certifies that the company

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

IEC and IEEE Standards for High-Voltage Switchgear and Controlgear Present Situation and Future Evolution

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Nothing s BetterThan the Original MODAN Power Distribution Systems

Vacuum Circuit Breaker Operator Module

PTC-Resistor Temperature-Sensors MINIKA to DIN and DIN

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

Power products and systems. Intelligent solutions for power distribution Zone concept

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

The On-Load Tap-Changer for Maximum Switching Frequency More Switching Operations without Needing Maintenance.

Common Features of Electromechanical Switches

Primary and Secondary Electrical Distribution Systems

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Series 8146/5-V37 and Series 8150/5-V37

2013 RESIBLOC transformers Product presentation. ABB Group October 2, 2013 Slide 1

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Proven vacuum switching technology from Siemens meets all requirements placed on circuit-breakers and contactors in medium-voltage switchgear up to

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Tmax MCCBs. Molded case circuit breakers. Tmax

Gas-insulated switchgear type series 8DN8. up to 170 kv, 63 ka, 4000 A. Answers for energy.

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Welcome IEEE Members and Guests Jan 20, 2014

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Mounting Instructions. Torque Transducer. A en

Electricity. Confirming Coulomb s law. LD Physics Leaflets P Wie. Electrostatics Coulomb s law

Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Compact pressure switch Flameproof enclosure Ex d Model PCA

Transcription:

VD4 Vacuum circuit-breaker

VD4. The economical solution in power distribution. Applications: Power stations Transformer stations Chemicals industry Steel industry Automotive industry Airport power supply Shipbuilding power supply Building power supply With its systematically developed technology, the vacuum circuit-breaker of type VD4 occupies a leading position in networks for electrical power distribution. The rated data are dimensioned to suit the users requirements. Designed for the operators, the VD4 circuit-breaker fulfils the high demands of users in all respects. 2

VD4. For every field of application. Vacuum circuit-breaker of type VD4 is designed for switching: short-circuit currents, cables and overhead lines under load and no-load conditions, transformers and generators under load and no-load conditions, ripple control systems, capacitor banks, and motors. 3

VD4. Vacuum circuit-breaker. In the circuit-breaker of type VD4, the complete pole and the maintenancefree vacuum interrupter form a positive unit. This is achieved by a specially developed casting technique in which the vacuum interrupter is directly embedded in epoxy resin to form a complete pole. Disruptive external effects on the switching element are therefore extensively precluded. For very high rated currents, rated short-circuit breaking currents and for rated voltages greater than 24 kv, the tried and tested assembled poles are still used. 4

VD4. The optimum concept. Higher reliability and availability and longer life with fewer fastening parts. Protection of the vacuum interrupters from impact, dust, and condensation. High dielectric protection of the vacuum interrupters without additional modifications. Ideal matching of the VD4 circuit-breaker with its power requirement, has been achieved by precisely controlled force transmission. This has made it possible to have only one type of operating mechanism for all the VD4 variants. The use of the same operating mechanism has the great advantage that even circuitbreakers manufactured relatively seldom, e.g. those with high rated currents or short-circuit breaking currents, have a tried and tested mechanism of which many thousands are in service. The vacuum circuit-breaker of type VD4 with manual mechanism is fundamentally suitable for autoreclosing; the version with motorized mechanism for multi-shot autoreclosing. In addition, the breaker can be fitted with all standard releases and auxiliary switches required for the particular switching function to be performed. 5

Rated voltage 1) kv 12/17.5 24 Rated current A 630/1250 630/1250 Rated short-circuit breaking current symm. 2) ka 16 20 25 31.5 16 20 25 Short-circuit breaking current asymm. 2) ka 17.4 21.7 27.3 34.3 17.4 21.7 27.3 Rated short-circuit making current 2) ka 40 50 63 80 40 50 63 Rated short-circuit duration s 3 3 3 3 3 3 3 Pol centre distance mm 150/210 150/210 150/210 150/210 210/275 210/275 210/275 Weight kg 70/75 70/75 70/75 81/86 78/83 78/83 82/87 Pole embedded Pole assembled Rated voltage 1) kv 12/17.5 12/17.5 24 Rated current A 1250 1600/2000/2500 1600/2000/2500 Rated short-circuit breaking current symm. 2) ka 40 20 25 31.5 40 3) 16 20 25 Short-circuit breaking current asymm. 2) ka 43.6 21.7 27.3 34.3 43.6 17.4 21.7 27.3 Rated short-circuit making current 2) ka 100 50 63 80 100 40 50 63 Rated short-circuit duration s 3 3 3 3 3 3 3 3 Pol centre distance mm 210 210/275 5) 210/275 5) 210/275 5) 210/275 5) 275 275 275 Weight kg 94 147/155 6) 147/155 6) 147/155 6) 147/155 6) 167 167 167 Pole embedded Pole assembled Rated voltage 1) kv 12 12 12 17.5 Rated current A 1250/1600/ 1250/1600/ 3150/4000 4) 1600/2000/ 2000/2500 2000 2500/3150 / 4000 4) Rated short-circuit breaking current symm. 2) ka 50 63 20 25 31.5 40 40 Short-circuit breaking current asymm. 2) ka 55.8 65.5 21.7 27.3 34.3 43.6 43.6 Rated short-circuit making current 2) ka 125 158 50 63 80 100 100 Rated short-circuit duration s 3 3 3 3 3 3 3 Pol centre distance mm 210/275 275 275 275 275 275 275 Weight kg 159 265 260 260 260 260 260 Pole embedded Pole assembled 6 1) Test voltages to VDE 0670, Part 1000, List 2 2) When the operating voltage is less than the rated voltage, the same values as for rated voltage always apply. Higher values in individual cases on request. 3) 40 ka for 12 kv only 4) Breaker with fan cooling 5) Pole centres 275 mm only for rated current 2500 A 6) Weight 159 kg for rated current 2500 A

12 kv,...1250 A,...31.5 ka p H a b c d e 17.5 kv,...1250 A,...31.5 ka mm mm mm mm mm mm mm 150 205 450 424 433 217.5 475 210 205 570 424 433 217.5 475 24 kv,...1250 A,...25 ka p H a b c d e mm mm mm mm mm mm mm 210 310 570 424 433 282.5 631 1) 275 310 750 424 433 282.5 631 1) 1) Measuring point pole part. 12 kv, 1250 A, 40 ka p H a b c d e 12 kv, 1600-2500 A,...40 ka mm mm mm mm mm mm mm 17.5 kv, 1600-2500 A,...31.5 ka 210 310 610 424 433 237.5 599 1) 275 310 750 424 433 237.5 599 1) 24 kv, 1600-2500 A,...25 ka p H a b c d e mm mm mm mm mm mm mm 275 310 750 424 433 282.5 642 2) 1) Breaker with heat-sink 616 mm 2) Breaker with heat-sink 661 mm 12 kv, 1250-2500 A, 50 ka p H a b c d e 17.5 kv, 1600-2500 A,...40 ka mm mm mm mm mm mm mm 210 310 610 459 433 237.5 615.5 275 310 750 459 433 237.5 615.5 12 kv, 3150/4000 A 1),...50 ka p H a b c d e 12 kv, 1250-2000 A, 63 ka mm mm mm mm mm mm mm 17.5 kv, 3150/4000 A 1), 40 ka 275 310 750 459 433 237.5 677.5 2) 1) Breaker with fan cooling 2) Breaker with heat-sink

VD4. Vacuum circuit-breaker.

VD4. A leading edge product. Practically unlimited applications High reliability Extremely high availability Absolutely maintenance-free Extremely economical 1 12 2 12 kv 3 4 5 6 7 8 9 11 10 1 Upper contact terminal 2 Vacuum interrupter 3 Epoxy resin enclosure 4 Lower contact terminal 5 Flexible connector 6 Contact force spring 7 Insulated coupling rod 8 Opening spring 9 Shift lever 10 Drive shaft 11 Release mechanism 12 Mechanism enclosure with spring operating mechanism Shown: Vacuum circuit-breaker type VD4 in embedded technique 12 kv, 1250 A, 25 ka

Leaflet no. DECMS 2291 01 E Printed in Germany (08.01-2000-PPI) We reserve the right to make changes in the course of technical development. ABB Calor Emag Mittelspannung GmbH Oberhausener Strasse 33 Petzower Strasse 8 D-40472 Ratingen D-14542 Glindow Phone: +49(0)21 02/12-12 30, Fax: +49(0)21 02/12-19 16 E-mail: calor.info@de.abb.com Internet: http://www.abb.de/calor