2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design



Similar documents
Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Terminal Boxes Series 8146

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Series 8146/5-V37 and Series 8150/5-V37

H45 LED - Direct and indirect pendant

A good connection. International approvals.

Explosion proof enclosures

Control and Distribution Boxes made of Stainless Steel Series 8150

REVO-LB. REVO LB (Low Bay Industrial Luminaires)

Operating Instructions

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Compact pressure switch Flameproof enclosure Ex d Model PCA

Watertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Plug and Socket Devices SolConeX 16 A Series 8570

FIREDEX Conventional Fire Panels

Emergency Light Fittings

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Abtech Custom Solutions

Plug and Socket Devices CES 63 A Series 8579

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Technical Data. Dimensions

SEISMIC VELOCITY TRANSDUCER T1-40

Floodlight Range Installation Guide

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Electric Rotary Actuator - On/Off or programmable control actuator

7 Lighting Technology

Inductive sensor NI10-M18-Y1X-H1141

IVIOS LED III. LUM Technical Information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

3/2-way Solenoid Valve, direct-acting, NC or NO

STB Series Enclosures

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

8146/5 Series Breaker Panelboards

Acclaim III Recessed Fluorescent Luminaires ATEX

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Terminal Box. Specifications TNCN

Flameproof Audible Signal 115 db (A) Series YA90

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

SITRANS F flowmeters SITRANS F M

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Technical Information RIA14

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

TEIP11 I/P signal converter for standard signals. Measurement made easy

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Contrast 2 LED. Performance Compactness Complete flexibility NEW

Morgue refrigeration unit

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Plastic tube flowmeters Series PT/PS

Biax S and S/E. Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.

Product and functional description

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Control Stations Made of Polyester Resin Series 8146

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Photovoltaic Solar Energy Unit EESFB

LED HIGHBAY COMMERCIAL & INDUSTRIAL DESIGNED MANUFACTURED AND WARRANTED IN AUSTRALIA

COOL Shelf Quick Connect

Operating Instructions

Medical Lighting. XL4 Patient Light

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

Safety instructions VEGADIS DIS81.CEIA/V****

Emergency lighting units EM powerled

e explosion-proof emergency light fittings battery sets for zone 1/21 and zone 2/22 e 187/ nd 187/188...

Digital inductive conductivity transmitter

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

CB200W Water Leak Detection Panel Application Guide

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Industrial Linergy LED

nano led THE GREEN LIGHT

Solenoid Valve Island Type 3965

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

DuroSite TM High Bay Lighting

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Assisted lift operated 2/2-way solenoid valves Type EV250B

Twin EL Wall luminaires for halogen lamps or ceramic metal halide lamps

Nightscape High performance floodlights and spotlights for discharge lamps

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Superlight Compact Nano

Aluminium Standard. Technical Data. Included in delivery

Rittal TopTherm fan-and-filter unit

Transcription:

.8 Ex-Recess-mounted, ceiling emergency light fittings in compact metal design RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX 50... N 18-36 W (Zone 1,, 1, ) The explosion-protected lighting concept for clean rooms The Ex recess-mounted, ceiling light fittings RLF.. are equipped with EVG 09 electronic ballasts and are suitable for two-pin fluorescent lamps. These lamps are used for surface and flush mounting in ceilings, in particular in clean rooms where smooth, flush surfaces are very important. The area of application is in the pharmaceutical and chemical industries, and experimental facilities, as well as in paint shops and spraying cabinets. Designed for easy installation The housing comprises whitepainted steel sheet with an optional cover frame for ceiling mounting. The type RLF-INOX is made of polished stainless steel. In addition, it can also be fixed by means of two M8 drilled holes on the top of the housing. The hinged, frameless pane made of 5 mm thick safety glass is fixed with 3 resp. 4 captive screws and has inside hinges. The EPDM sealing ensures the high degree of protection IP65. Long-term safety Thanks to its large input voltage range, the latest generation of electronic ballasts can be used internationally and features an EOL circuit. The dual-channel structure of the electronic ballasts allows the safe operation of the second lamp if one lamp fails. Versatile In conjunction with the generously dimensioned terminal compartment, the standard, twin-ended through-wiring allows a cost-effective installation. The luminaire switch reliably prevents the light from being turned on while the cover is open. If you need a reliable and decentralized emergency lighting The RLF N emergency luminaires with a self-contained battery system provide a decentralised solution for the mandatory emergency lighting, independent of central systems. In large plants, in particular, these luminaires offer significant cost benefits. The emergency lighting version with a self-contained batterysystem containing NC batteries allows an emergency lighting cycle of 1.5 or 3 hours. Using mounting brackets the luminaires can be installed adjustable on walls or ceilings Features Standard dual channel ballast with EOL monitoring Flush Installation, specially for clean rooms Available in painted sheet steel or stainless steel Safety interlock with integrated luminaire switch With self-contained battery unit (RLF 50 N) High degree of protection IP66 Suitable for B15 fire resistance ceilings 1..60 EATON www.crouse-hinds.de

Ordering details RLF 50... / RLF-INOX 50....8 Ordering details Type Content Terminals Throughwiring single-ended Throughwiring twin-ended Cable gland/ thread Screw plugs Blanking plug Order No. RLF 50../.. (twin lamp) RLF 5018/18 ( x 18 W) /5-K x 5 x x M5, plastic 1 1 83 18 001 RLF 5018/18 ( x 18 W) /5-M 1) x 5 x x M0, metal thread 1 x M0 1 83 18 00 RLF 5036/36 ( x 36 W) /5-K x 5 x x M5, plastic 1 1 83 36 001 RLF 5036/36 ( x 36 W) /5-M 1) x 5 x x M0, metal thread 1 x M0 1 83 36 00 RLF 5058/58 ( x 58 W) /5-K x 5 x x M5, plastic 1 1 83 58 001 RLF 5058/58 ( x 58 W) /5-M 1) x 5 x x M0, metal thread 1 x M0 1 83 58 00 RLF 503.. (three lamps) RLF 50336 (3 x 36 W) /5-K x 5 x x M5, plastic 1 1 83 336 011 RLF 50336 (3 x 36 W) /5-M 1) x 5 x x M0, metal thread 1 x M0 1 83 336 01 RLF 50358 (3 x 58 W) /5-K x 5 x x M5, plastic 1 1 83 358 011 RLF 50358 (3 x 58 W) /5-M 1) x 5 x x M0, metal thread 1 x M0 1 83 358 01 RLF 504.. (four lamps) RLF 50418 (4 x 18 W) /5-K x 5 x x M5, plastic 1 1 83 418 011 RLF 50418 (4 x 18 W) /5-M 1) x 5 x x M0, metal thread 1 x M0 1 83 418 01 RLF 50436 (4 x 36 W) /5-K x 5 x x M5, plastic 1 1 83 436 011 RLF 50436 (4 x 36 W) /5-M 1) x 5 x x M0, metal thread 1 x M0 1 83 436 01 RLF 50458 (4 x 58 W) /5-K x 5 x x M5, plastic 1 1 83 458 011 RLF 50458 (4 x 58 W) /5-M 1) x 5 x x M0, metal thread 1 x M0 1 83 458 01 RLF-INOX 50../.. (twin lamp, stainless steel version) RLF-INOX 5018/18 ( x 18 W) /5-M 1) x 5 x x M0, metal thread 1 x M0 1 83 18 003 RLF-INOX 5018/18 ( x 18 W)) /5-K x 5 x x M5, plastic 1 1 83 18 004 RLF-INOX 5036/36 ( x 36 W) /5-K x 5 x x M5, plastic 1 1 83 36 003 RLF-INOX 5036/36 ( x 36 W)) /5-M 1) x 5 x x M0, metal thread 1 x M0 1 83 36 004 RLF-INOX 5058/58 ( x 58 W) /5-K x 5 x x M5, plastic 1 1 83 58 003 RLF-INOX 5058/58 ( x 58 W) /5-M 1) x 5 x x M0, metal thread 1 x M0 1 83 58 004 RLF-INOX 503.. (three lamps, stainless steel version) RLF-INOX 50336 (3 x 36 W) /5-K x 5 x x M5, plastic 1 1 83 336 001 RLF-INOX 50336 (3 x 36 W) /5-M 1) x 5 x x M0, metal thread 1 x M0 1 83 336 00 RLF-INOX 50358 (3 x 58 W) /5-K x 5 x x M5, plastic 1 1 83 358 001 RLF-INOX 50358 (3 x 58 W) /5-M 1) x 5 x x M0, metal thread 1 x M0 1 83 358 00 RLF-INOX 504.. (four lamps, stainless steel version) RLF-INOX 50418 (4 x 18 W) /5-K x 5 x x M5, plastic 1 1 83 418 001 RLF-INOX 50418 (4 x 18 W) /5-M 1) x 5 x x M0, metal thread 1 x M0 1 83 418 00 RLF-INOX 50436 (4 x 36 W) /5-K x 5 x x M5, plastic 1 1 83 436 001 RLF-INOX 50436 (4 x 36 W) /5-M 1) x 5 x x M0, metal thread 1 x M0 1 83 436 00 RLF-INOX 50458 (4 x 58 W) /5-K x 5 x x M5, plastic 1 1 83 458 001 RLF-INOX 50458 (4 x 58 W) /5-M 1) x 5 x x M0, metal thread 1 x M0 1 83 458 00 Scope of delivery without lamp and fixing accessories Metal cable glands see catalogue part :.3.1 ff www.crouse-hinds.de EATON 1..61

.8 Ordering details RLF 50../.. N / RLF INOX 50../.. N Ordering details Type Content Emergency Terminals Through- Through- Cable gland/ thread Screw Order No. lighting wiring wiring plugs duration single-ended twin-ended RLF 50../.. N (twin lamp) RLF 5018/18 N ( x 18 W) /6-K 1.5 h x 6 x x M5, plastic 1 x M5 1 83 18 01 RLF 5018/18 N ( x 18 W) /6-M 1.5 h x 6 x x M0 x 1.5, metal thread 1 x M0 1 83 18 0 RLF 5018/18 N ( x 18 W) /6-K 3 h x 6 x x M5, plastic 1 x M5 1 83 18 301 RLF 5018/18 N ( x 18 W) /6-M 3 h x 6 x x M0 x 1.5, metal thread 1 x M0 1 83 18 30 RLF 5036/36 N ( x 36 W) /6-K 1.5 h x 6 x x M5, plastic 1 x M5 1 83 36 01 RLF 5036/36 N ( x 36 W) /6-M 1.5 h x 6 x x M0 x 1.5, metal thread 1 x M0 1 83 36 0 RLF 5036/36 N ( x 36 W) /6-K 3 h x 6 x x M5, plastic 1 x M5 1 83 36 301 RLF 5036/36 N ( x 36 W) /6-M 3 h x 6 x x M0 x 1.5, metal thread 1 x M0 1 83 36 30 RLF 504.. N (four lamps) RLF 50418 N (4 x 18 W) /6-K 1.5 h x 6 x x M5, plastic 1 x M5 1 83 418 01 RLF 50418 N (4 x 18 W) /6-M 1.5 h x 6 x x M0 x 1.5, metal thread 1 x M0 1 83 418 0 RLF 50418 N (4 x 18 W) /6-K 3 h x 6 x x M5, plastic 1 x M5 1 83 418 301 RLF 50418 N (4 x 18 W) /6-M 3 h x 6 x x M0 x 1.5, metal thread 1 x M0 1 83 418 30 RLF 50436 N (4 x 36 W) /6-K 1.5 h x 6 x x M5, plastic 1 x M5 1 83 436 01 RLF 50436 N (4 x 36 W) /6-M 1.5 h x 6 x x M0 x 1.5, metal thread 1 x M0 1 83 436 0 RLF 50436 N (4 x 36 W) /6-K 3 h x 6 x x M5, plastic 1 x M5 1 83 436 301 RLF 50436 N (4 x 36 W) /6-M 3 h x 6 x x M0 x 1.5, metal thread 1 x M0 1 83 436 30 RLF INOX 50../.. N (twin lamp, stainless steel version) RLF-INOX 5018/18 N /6-K 1.5 h x 6 x x M5, plastic 1 x M5 1 83 18 03 ( x 18 W) RLF-INOX 5018/18 N /6-M 1.5 h x 6 x x M0 x 1.5, metal thread 1 x M0 1 83 18 04 ( x 18 W) RLF-INOX 5018/18 N /6-K 3 h x 6 x x M5, plastic 1 x M5 1 83 18 303 ( x 18 W) RLF-INOX 5018/18 N /6-M 3 h x 6 x x M0 x 1.5, metal thread 1 x M0 1 83 18 304 ( x 18 W) RLF-INOX 5036/36 N /6-K 1.5 h x 6 x x M5, plastic 1 x M5 1 83 36 03 ( x 36 W) RLF-INOX 5036/36 N /6-M 1.5 h x 6 x x M0 x 1.5, metal thread 1 x M0 1 83 36 04 ( x 36 W) RLF-INOX 5036/36 N /6-K 3 h x 6 x x M5, plastic 1 x M5 1 83 36 303 ( x 36 W) RLF-INOX 5036/36 N /6-M 3 h x 6 x x M0 x 1.5, metal thread 1 x M0 1 83 36 304 ( x 36 W) RLF INOX 504.. N (four lamps, stainless steel version) RLF-INOX 50418 N /6-K 1.5 h x 6 x x M5, plastic 1 x M5 1 83 418 03 (4 x 18 W) RLF-INOX 50418 N /6-M 1.5 h x 6 x x M0 x 1.5, metal thread 1 x M0 1 83 418 04 (4 x 18 W) RLF-INOX 50418 N /6-K 3 h x 6 x x M5, plastic 1 x M5 1 83 418 303 (4 x 18 W) RLF-INOX 50418 N /6-M 3 h x 6 x x M0 x 1.5, metal thread 1 x M0 1 83 418 304 (4 x 18 W) RLF-INOX 50436 N /6-K 1.5 h x 6 x x M5, plastic 1 x M5 1 83 436 03 (4 x 36 W) RLF-INOX 50436 N /6-M 1.5 h x 6 x x M0 x 1.5, metal thread 1 x M0 1 83 436 04 (4 x 36 W) RLF-INOX 50436 N /6-M 3 h x 6 x x M5, plastic 1 x M5 1 83 436 303 (4 x 36 W) RLF-INOX 50436 N /6-M 3 h x 6 x x M0 x 1.5, metal thread 1 x M0 1 83 436 304 (4 x 36 W) Scope of delivery without lamp and fixing accessories Metal cable glands see catalogue part :.3.1 ff 1..6 EATON www.crouse-hinds.de

Accessories / Polar curve / Dimension drawing RLF 50... / RLF-INOX 50....8 Accessories Type Application Order No. Mounting frame for ceiling mounting for RLF 5018/18, x 18W 3 83 000 001 Mounting frame for ceiling mounting for RLF 50418, 4 x 18 W 3 83 000 00 Mounting frame for ceiling mounting for RLF 50, /3 x 36 W, 3 83 000 003 Mounting frame for ceiling mounting for RLF 50436, 4 x 36 W 3 83 000 004 Mounting frame for ceiling mounting for RLF 50, /3 x 58 W 3 83 000 005 Mounting frame for ceiling mounting for RLF 50458, 4 x 58 W 3 83 000 006 Mounting frame for ceiling mounting for RLF-INOX 5018/18, x 18W 3 83 000 008 Mounting frame for ceiling mounting for RLF-INOX 50418, 4 x 18 W 3 83 000 009 Mounting frame for ceiling mounting for RLF-INOX 5, /3 x 36 W, 3 83 000 010 Mounting frame for ceiling mounting for RLF-INOX 50436, 4 x 36 W 3 83 000 011 Mounting frame for ceiling mounting for RLF-INOX 5, /3 x 58 W 3 83 000 01 Mounting frame for ceiling mounting for RLF-INOX 50458, 4 x 58 W 3 83 000 013 Set of wall bracket adjustable ( pcs.) for RLF 50.. 3 83 000 007 Polar curve RLF 90 90 75 50 100 75 60 150 60 C 0 C90 45 30 15 00 50 0 15 30 45 l/cd/klm RLF 50... 18 W = 701 36 W = 131 58 W = 1611 130 4 lamp = 36 /3 lamp = 30 Ceiling cut-out 1-3 lamp 33 4 lamp 383 18 W = 743 36 W = 1353 58 W = 1653 18 W = 450 36/58 W = 800 Dimensions in mm www.crouse-hinds.de EATON 1..63

.8 RLF 5018/18 / RLF 50418 / RLF 5036/36 / RLF 50336 RLF 5018/18 / RLF 50418 RLF 5036/36 / RLF 50336 EC-Type Examination Certificate FTZU 06 ATEX 0050 X FTZU 06 ATEX 0050 X Marking accd. to 94/9/EC D II G Ex ed IIC T4 Gb D II G Ex ed IIC T4 Permissible ambient temperature -0 C up to +40 C -0 C up to +40 C Rated voltage 110-54 V AC / 110-50 V DC 110-54 V AC / 110-50 V DC Rated current 0.18 A / 0.36 A 0.34 A / 0.51 A Frequency 50-60 Hz 50-60 Hz Power factor cos 0.95 0.95 Circuit EVG EVG Protection class I I Lamp / Illuminant x T6 / 18 W (T8) / 4 x T6 / 18 W (T8) x T6 / 36 W (T8) / 3 x T6 / 36 W (T8) Rated luminous flux 700 lm 1) / 5400 lm 1) 6700 lm 1) / 10050 lm 1) Lamp cap G13 accd. to IEC 60061-1 G13 accd. to IEC 60061 Light output ratio 70 % / 69 % 70 % / 68 % Dimensions (L x W x H) 701 x 30 x 130 mm / 701 x 36 x 130 mm 131 x 30 x 130 mm Connecting terminals L1, L, L3, N, PE; max. x.5 mm L1, L, L3, N, PE; max. x.5 mm Enclosure colour white RAL 9010 white RAL 9010 Enclosure material Weight 6.9 kg / 9.5 kg 1.9 kg / 13.4 kg Cable glands / gland plates / enclosure drilling Ex-e cable glands M5 x 1.5 (plastic), option: M0 x 1.5 metal thread ) Ex-e cable glands M5 x 1.5 (plastic), option: M0 x 1.5 metal thread ) Degree of protection accd. to EN 6059 IP65 IP65 Protective cover / protective bowl single-safety glass pane of 5 mm thick single-safety glass pane of 5 mm thick 1) depends on used lamps ) with dustcover if entry/thread is not closed 1..64 EATON www.crouse-hinds.de

RLF 50436 / RLF 5058/58.8 RLF 50436 RLF 5058/58 EC-Type Examination Certificate FTZU 06 ATEX 0050 X FTZU 06 ATEX 0050 X Marking accd. to 94/9/EC D II G Ex ed IIC T4 D II G Ex ed IIC T4 Permissible ambient temperature -0 C up to +40 C -0 C up to +40 C Rated voltage 110-54 V AC / 110-50 V DC 0-54 V AC / 195-50 V DC Rated current 0.68 A 0.53 A Frequency 50-60 Hz 50-60 Hz Power factor cos 0.95 0.95 Circuit EVG EVG Protection class I I Lamp / Illuminant 4 x T6 / 36 W (T8) x T6 / 58 W (T8) Rated luminous flux 13400 lm 1) 10400 lm 1) Lamp cap G13 accd. to IEC 60061-1 G13 accd. to IEC 60061-1 Light output ratio 69 % 68 % Dimensions (L x W x H) 131 x 36 x 130 mm 1611 x 30 x 130 mm Connecting terminals L1, L, L3, N, PE; max. x.5 mm L1, L, L3, N, PE; max. x.5 mm Enclosure colour white RAL 9010 white RAL 9010 Enclosure material Weight 16.5 kg 17. kg Cable glands / gland plates / enclosure drilling Ex-e cable glands M5 x 1.5 (plastic), option: M0 x 1.5 metal thread ) Ex-e cable glands M5 x 1.5 (plastic), option: M0 x 1.5 metal thread ) Degree of protection accd. to EN 6059 IP65 IP65 Protective cover / protective bowl single-safety glass pane of 5 mm thick single-safety glass pane of 5 mm thick 1) depends on used lamps ) with dustcover if entry/thread is not closed www.crouse-hinds.de EATON 1..65

.8 RLF 50358 / RLF 50458 RLF 50358 RLF 50458 EC-Type Examination Certificate FTZU 06 ATEX 0050 X FTZU 06 ATEX 0050 X Marking accd. to 94/9/EC D II G Ex ed IIC T4 D II G Ex ed IIC T4 Gb Permissible ambient temperature -0 C up to +40 C -0 C up to +40 C Rated voltage 0-54 V AC / 195-50 V DC 0-54 V AC / 195-50 V DC Rated current 0.80 A 1.06 A Frequency 50-60 Hz 50-60 Hz Power factor cos 0.95 0.95 Circuit EVG EVG Protection class I I Lamp / Illuminant 3 x T6 / 58 W (T8) 4 x T6 / 58 W (T8) Rated luminous flux 15600 lm 1) 0800 lm 1) Lamp cap G13 accd. to IEC 60061-1 G13 accd. to IEC 60061-1 Light output ratio 66 % 67 % Dimensions (L x W x H) 1611 x 30 x 130 mm 1611 x 36 x 130 mm Connecting terminals L1, L, L3, N, PE; max. x.5 mm L1, L, L3, N, PE; max. x.5 mm Enclosure colour white RAL 9010 white RAL 9010 Enclosure material Weight 17.8 kg 19.8 Kg Cable glands / gland plates / enclosure drilling Ex-e cable glands M5 x 1.5 (plastic), option: M0 x 1.5 metal thread ) Ex-e cable glands M5 x 1.5 (plastic), option: M0 x 1.5 metal thread ) Degree of protection accd. to EN 6059 IP65 IP65 Protective cover / protective bowl single-safety glass pane of 5 mm thick single-safety glass pane of 5 mm thick 1) depends on used lamps ) with dustcover if entry/thread is not closed 1..66 EATON www.crouse-hinds.de

RLF 5018/18 N / RLF 5036/36 N / RLF 50418 N / RLF 50436 N.8 RLF 5018/18 N / RLF 5036/36 N RLF 50418 N / RLF 50436 N EC-Type Examination Certificate FTZU 06 ATEX 0050 X FTZU 06 ATEX 0050 X Marking accd. to 94/9/EC D II G Ex d e ib mb IIC T4 Gb D II G Ex d e ib mb IIC T4 Gb Permissible ambient temperature 0 C up to +40 C (specified data) 0 C up to +40 C Battery 3.6 V/4 Ah NC-Accu / 6 V/4 Ah NC-Accu 3.6 V/4 Ah NC-Accu / 6 V/4 Ah NC-Accu Rated voltage 30-40 V AC 30-40 V AC Rated current 0.0 A / 0.36 A 0.36 A / 0.68 A Frequency 50-60 Hz 50-60 Hz Charging duration 4 h 4 h Power factor cos 0.95 0.95 Circuit EVG with emergency lighting supply EVG with emergency lighting supply Protection class I I Lamp / Illuminant x T6 / 18 W (T8) / x T6 / 36 W (T8) 4 x T6 / 18 W (T8) / 4 x T6 / 36 W (T8) Rated luminous flux 700 lm 1) / 6700 lm 1) 5400 lm 1) / 13400 lm 1) Lamp cap G13 accd. to IEC 60061-1 G13 accd. to IEC 60061-1 Light output ratio 70 % 70 % Luminous flux in emergency operation 70 lm (0 %) / 603 lm (18 %) 70 lm (0 %) / 603 lm (18 %) (1.5 h, one lamp) Luminous flux in emergency operation 16 lm (16 %) / 436 lm (13 %) 16 lm (16 %) / 436 lm (13 %) (3 h, one lamp) Rated emergency lighting duration 1.5 h / 3 h 1.5 h / 3 h Dimensions (L x W x H) 701 x 30 x 130 mm / 131 x 30 x 130 mm 701 x 36 x 130 mm / 131 x 36 x 130 mm Connecting terminals L, L1, L, L3, N, PE; max. x.5 mm² L, L1, L, L3, N, PE; max. x.5 mm² Enclosure colour white RAL 9010 white RAL 9010 Enclosure material optional polished stainless steel optional polished stainless steel Weight 8.9 kg / 14.9 kg 11.5 kg / 18.5 kg Cable glands / gland plates / enclosure drilling Ex-e cable glands M5 x 1.5 (plastic), option: M0 x 1.5 metal thread ) Ex-e cable glands M5 x 1.5 (plastic), option: M0 x 1.5 metal thread ) Degree of protection accd. to EN 6059 IP65 IP65 Protective cover / protective bowl single-safety glass pane of 5 mm thick single-safety glass pane of 5 mm thick 1) depends on used lamps ) with dustcover if entry/thread is not closed www.crouse-hinds.de EATON 1..67