Reactive Power Compensation. ABB High Voltage Products June 19, 2013 Slide 1

Similar documents
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Power Capacitor Units for improved power quality

Capacitors and Filters Improving power quality for efficiency and reliability

7. Reactive energy compensation

FACTS. Solutions to optimise network performance GRID

DYNACOMP The top-class dynamic response compensator

The design and performance of Static Var Compensators for particle accelerators

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

Typical Data Requirements Data Required for Power System Evaluation

GUIDELINES TO INSTALL, OPERATE AND MAINTAIN HT CAPACITORS & IT S ASSOCIATED EQUIPMENT

CAPACITOR BANK TESTING SWP

Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

POWER FACTOR CORRECTION

EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Power Capacitors and Harmonic Filters Buyer s Guide

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

HVDC 2000 a new generation of high-voltage DC converter stations

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

How To Build A Low Voltage Capacitor Lvcp

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

13. Electrical network design methodology and application example

Transformer Bushings for GIS

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Introduction. Harmonics and IEEE 519 Page 1 of 19

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks

Fusible Disconnect Switch

The Facts About Harmonics and Power Factor. Power Quality: Harmonics & Power Factor Correction

MV POWER CAPACITORS AND BANKS. All film dielectric MV Power Capacitors QUALITY MADE IN ITALY

Circulating Current Relay. Type IRXm

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Bourns Resistive Products

Earth Fault Detection Basics in Theory

Assessment of the Technical Issues relating to Significant Amounts of EHV Underground Cable in the All-island Electricity Transmission System

HVDC Light, a tool for electric power transmission to distant loads

Guide for the Design and Production of LV Power Factor Correction Cubicles

SUITABILITY OF DIFFERENT TEST VOLTAGES FOR ON-SITE TESTING OF XLPE CABLE SYSTEMS

EXTENDING THE LIFE OF POWER FACTOR CAPACITORS

Product Data Bulletin

High-Voltage GIS yesterday - today - tomorrow

Modular Systems wind portfolio overview Power Collection and Grid Connection products

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

HOW HARMONICS HAVE CONTRIBUTED TO MANY POWER FACTOR MISCONCEPTIONS

COMPARISON OF THE FACTS EQUIPMENT OPERATION IN TRANSMISSION AND DISTRIBUTION SYSTEMS

HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM

How To Understand The Electrical Power Supply Of A Power Supply System

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

Presentation of the France Transfo factories

Unified requirements for systems with voltages above 1 kv up to 15 kv

Hyperlinks are Inactive

Line Reactors and AC Drives

Standards in Marine Power Systems. APEC 2014 Session IS2.1 Power Electronic Standards Roger Dougal University of South Carolina Columbia, SC 29208

Guideline for Energy Efficient Electrical systems for building. Presentation by TERI

DC TRANSMISSION BASED ON VOLTAGE SOURCE CONVERTERS

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

Power transformers. Special transformers Railway

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

AC Power. by Prof. Dr. Osman SEVAİOĞLU Electrical and Electronics Engineering Department

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

The Intelligent AX1 Switchgear for Medium Voltage

Trip circuit supervision relay. Type RXTCS

SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE WELDERS

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Volt-VAr Management Software (V VMS) for smart grid distribution automation applications

Safe and reliable distribution network ABB portfolio for medium-voltage indoor applications

Joslyn Clark Controls, Inc.

How To Choose A Transformer

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Enhanced Quality with a Touch of Style

SURVEY OF HARMONIC DISTORTION IN LV AND MV NETWORKS: RESULTS AND CORRECTIVE STRATEGIES

Specifying a Variable Frequency Drive s

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Power Quality Issues, Impacts, and Mitigation for Industrial Customers

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Protection from Short-circuit

IEC and IEEE Standards for High-Voltage Switchgear and Controlgear Present Situation and Future Evolution

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

Step Voltage Regulators

Electric Power Distribution

Instrument Transformers Application Guide

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Transformers Energy efficient transformer solutions European Minimum Energy Performance Standard (MEPS)

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Engineering innovation

Topics. HVDC Fundamentals

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Tamini is the leading Italian company in the world for the design and production of industrial, power and special transformers.

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Transcription:

José Matias High Voltage Components ABB AB Santiago - Chile, 05-June-2013 Reactive Power Compensation June 19, 2013 Slide 1

Reactive Power Compensation Main Topics Topics Introduction The need for capacitors Reactive power Effects of reactive power Reactive power compensation Implementing compensation in network Benefits of reactive power compensation Compensation solutions Capacitors: Main components & Building blocks ABB Capacitors: History & background ABB Capacitors: Solutions & Portfolio June 19, 2013 Slide 2

Reactive Power Compensation Introduction June 19, 2013 Slide 3

Power factor Displacement factor (cos φ) Generation Active Power Reactive Power Load Benefits Improves system power factor Reduces network losses cos φ = 0.80 Before compensation cos φ = 0.95 After compensation Reactive power compensation implies compensating the reactive power consumed by electrical motors, transformers etc. Avoid penalty charges from utilities for excessive consumption of reactive power Reduces cost and generates higher revenue for the customer Increases system capacity and saves cost on new installations Improves voltage regulation in the network Increases power availability June 19, 2013 Slide 4

Power factor Harmonic distortion Benefits Current waveform before harmonic filtering Current waveform after harmonic filtering Harmonic filtering implies mitigating harmonic currents generated by the nonlinear loads like rectifiers, drives, furnaces, welding machines, converters, HF lamps, electronic equipments etc in the network. Reduces harmonic content in the network which further reduces disturbances in telecommunication network, misbehavior in control equipments and relay protections, measuring errors in metering system Reduces network losses Reduces equipment overloading & stress on insulation Reduces cost and generates higher revenue for the customer Reduces unplanned outages and increases power availability June 19, 2013 Slide 5

June 19, 2013 Slide 6 The need for capacitors We operate on all voltages in the network Reactive Power Compensation/Harmonic Filter Reactive Power Compensation/Harmonic Filter Reactive Power Compensation/Harmonic Filter

Reactive power Definitions Q S Active power (P) It is the useful power that is doing the actual work. It is measured in W, kw, MW & calculated as, P = S x cos φ Reactive power (Q) It is a consequence of an AC system. Reactive power are used to build up magnetic fields. It is measured in var, kvar, Mvar & calculated as, Q = S x sin φ or P x tan φ P Apparent power (S) Or total power (S) is the combination of active and reactive power. Apparent power is measured in VA, kva, MVA Power factor (cos ) It is a measurement of the efficiency in a system. Power factor describes the relationship between active (P) and apparent Power (S) June 19, 2013 Slide 7

Reactive power need/ demand (supplied from network) Reactive power Compensation cos power factor before compensation cos power factor after compensation Q S Reactive power compensation (supplied by capacitors) Q S Reduced reactive power need/ demand (supplied by network) ABB Group June 19, 2013 Slide 8 Active power P Available active power

Reactive power Implementing the compensation in the network Shunt compensation of reactive power can be employed either at load level, substation level or at transmission level. *D Compensation should be provided as close as possible to the consumption point to avoid having to distribute this power in the other part of network. *C Location is primarily determined by the reason for compensation. *A : Direct Compensation *B : Group Compensation M M M *B M *A *C : Central Compensation at LV side *D : Central Compensation at HV side June 19, 2013 Slide 9

Example of power factor correction Relief in transformer loading Connected load 1000 kw Connected load 1000kW 1425 kva (95% loading factor) Cos = 0.7 1020 kvar 1500kVA Transformer Recovered Capacity = 0kVA (0%) 1425kVA AC Supply ~1100kVA (74% loading factor) Cos = 0.9 1020 kvar 470 kvar 22% available 1500kVA Transformer Recovered Capacity = 325 kva (22 %) Power triangle of an installation running at low cos and for which the transformer is close to full load Power triangle of the same installation where power factor correction has been applied reduces load on the transformer / releases capacity for additional loads June 19, 2013 Slide 10

Reactive Power Compensation Added value: optimizing power availability 10 kv M 60 MW Compensation 10 kv M 60 MW Cos φ1 = 0,85 Cos φ2 = 0,97 Q free = % * P according to tariff Example 0.15 x 60 MW = 9 Mvar S 1 φ 1 Q 1 Compensation S 2 φ 2 Q 2 P = 60 MW P = 60 MW June 19, 2013 Slide 11

Reactive Power Compensation Advantages: Summary/Conclusion Q free = X % x P according to tariff/utility regulation Max. Q free allowed from utility= 0,15 * 60 = 9 Mvar Q Q 1 Before After φ 1 S 1 S 2 φ 2 Q 2 P Consumption exceeding limits (28.1 Mvar) 9 Mvar (free) ΔQ Compensation supplied by capacitor (22.1 Mvar) Reduced consumption exceeding limits (6 Mvar) 9 Mvar (free) P = 60 MW Before After Cos φ 1 = 0,85 Cos φ 2 = 0,97 28,14 Mvar (76%) 9 Mvar (24%) 22,14 Mvar (60%) 9 Mvar (24%) 6 Mvar (16%) P= 60 MW S 1 = 70,59 MVA S 2 = 61,86 MVA Q 1 = 37,19 Mvar Q 2 = 15,04 Mvar ΔQ= 22,1 Mvar (cap. Bank power) Supplied from Utility (Free) Supplied from Utility (Charged) Supplied from Utility (Free) Supplied from Utility (Charged) Supplied from capacitor bank June 19, 2013 Slide 12

Reactive Power Compensation Purpose Solution depends on aim: Reactive Power need and no harmonics Capacitor Banks Reactive Power need and no distortion even if Harmonics are present Detuned Filters Reactive Power need and distortion problems Tuned Filters Reactive Power need and strong distortion problems such as fast voltage fluctuations and/or phase asimetry Dynamic / SVC s June 19, 2013 Slide 13

Reactive power Apparent, Active & Reactive Power REACTIVE POWER Beer: Foam Electricity - Unable to do work APPARENT POWER Beer: Full glass Electricity - Available from utility REAL POWER Beer: Drinkable Electricity = Able to do work It is the Active Power that contributes to the energy consumed, or transmitted. Reactive Power does not contribute to the energy. It is an inherent part of the total power which is often referred as Useless Power. June 19, 2013 Slide 14

ABB Capacitors Main components & Building Blocks June 19, 2013 Slide 15

Main components and building blocks Basic definitions: Capacitor & Capacitance Capacitor Two conductor layers separated by a insulating layer (dielectric) U+ h Capacitance Area of the plates = w x d Distance between the plates (thickness of the dielectric) Permittivity of the insulating material (dielectric) or Dielectric constant w U- d Reactive Power Capacitance Voltage Frequency June 19, 2013 Slide 16

kv / mm ABB s unique features Reliable and well utilized capacitor elements Optimal electric field strength, well utilized insulation: 100 50 0 Air Breakdown, AC Cables, AC Capacitors, AC Design with safety margins: Several film layers (normally three) High electrical withstand Folded foils at electrode edges Low electric stress amplification Minimized PD generation June 19, 2013 Slide 17

Reliability ABB Capacitors: well proven experience We know that world-class products, requires top of the line personnel, careful selection of materials and most modern machinery. Our workshop has the most modern machinery and processes. These are often tailor made in order to satisfy the high demands of our customers. ABB Group June 19, 2013 Slide 18

Reliability ABB Capacitors: Failure rates examples Project (Installed) Application No. of units Failure (%/year) Itaipu (1985-93) HVDC 15224 0.03 IPP (1986-91) HVDC 13786 0.05 Pacific (1987-94) Filter 1008 0.15 Itaipu (1990-94) SC 5040 0.04 Rihand-Delhi HVDC 6103 0.004 ABB Group June 19, 2013 Slide 19

Power Factor Compensation & Filter Solutions Basic definitions: Capacitor unit components Bushing Elements Internal fuse Discharge resistor Internal insulation Can (stainless steel) June 19, 2013 Slide 20

ABB s unique features HiQ units available in all type of fusing technologies ABB Design Conventional Internally fused Externally fused Fuseless Fuse Discharge Resistor June 19, 2013 Slide 21

ABB s unique features Expertise in all type of fusing technologies ABB is the only manufacturer supplying all types of fusing technologies June 19, 2013 Slide 22

ABB s unique features Large units - gives lower cost for the customer Same dielectric stress Same number of elements Same active material Less passive material (bushings, insulation etc.) Less ground area implies Less foundation Less fence June 19, 2013 Slide 23

Power Factor Compensation & Filter Solutions Capacitor Banks: Core components Bank design means transforming the requested reactive power into a physical structure with all environmental aspects and customer requirements taken into account. Elements Racks Cables & Busbars QBANK-A Stacked Elements Capacitor Units Insulators Unbalance CT June 19, 2013 Slide 24

Power Factor Compensation & Filter Solutions Harmonic Filters: Core components Capacitors C [µf] C Reactors L [mh] Resistance R [Ω] R L For filter performance these values are the important Design voltages and currents come out of these, based on the system calculations. June 19, 2013 Slide 25

Power Factor Compensation ABB Capacitors History and background June 19, 2013 Slide 26

ABB Capacitors ABB Production Facilities & Technical Centers Quebec PQC & LAU Ludvika TLC HV HV Capacitor factory Youngwood, PA LAU Jumet TLC LV Bulgaria LAU Xian HV Capacitor factory Galindo PQC & LAU Bangkok LV San Luis Potosi, MX LAU Number of HV/MV factories: 4 Guarulhos PQC & LAU Bangalore HV Capacitor factory Number of LV factories: 2 Local assembly units: 5 Sales Office in 100 countries Johannesburg HV Capacitor factory Lilydale LAU June 19, 2013 Slide 27

ABB in Ludvika A world center of high voltage Surge Arresters Instrument Transformers Capacitor Banks Live Tank Circuit Breakers Disconnecting Circuit Breakers One-Stop source for air-insulated HV equipment June 19, 2013 Slide 28

ABB in Ludvika The High Voltage Valley June 19, 2013 Slide 29

Capacitors in ABB Technical Lead Center in Ludvika Technical lead center for ABB medium and high voltage capacitors One of the worlds largest factories for capacitors. Most modern factory in the world Export: >95% Employees: app. 150 Capacitor plant area Volume: 30 000 Mvar/year June 19, 2013 Slide 30

Capacitors in ABB High quality production facility One of the most modern production lines with: Continuous optimization and improvement programs Certified personnel Traceability through Electronic control cards Order no., part no., batch no., operator s name etc. stored at each workstation through barcode system Extremely low failure rate for capacitor units Quality ensured by most modern optimized production process June 19, 2013 Slide 31

Power Factor Compensation ABB MV & HV Product Portfolio June 19, 2013 Slide 32

Am ps Vo lts ABB Capacitors Product Scope Measuring Harmonic Analyses / Calculations Line voltages & line currents at pumping cluster Solution 750 500 250 0-25 0-50 0-75 0 300 0 200 0 100 0 0-10 00-20 00-30 00 10:25:43.72 10:25:43.73 10:25:43.74 10:25:43.75 10:25:43.76 10:25:43.77 10:25:43.78 CH A CH B Volts Vo lts CH B Am CH C Am p s Volts CH C CH A Am p s p s Voltage: THDV = 12% Current: THDI = 27% Waveform event at 22/11/01 10:25 :43.533 Product delivery Measuring Education We can meet all customer needs June 19, 2013 Slide 33

ABB MV & HV Capacitors Portfolio Capacitor units: HiQ capacitors for all applications Capacitor unit types Internally fused units Unit voltage range: Reactive power range: 1-15 kv 300-1200 kvar (50 Hz) Externally fused units Unit voltage range: Reactive power range: 2.4 25 kv 100 500 kvar (50 Hz) ABB fuseless units Unit voltage range: Reactive power range: 12 25 kv 300 1200 kvar (50 Hz) June 19, 2013 Slide 34

ABB MV & HV Capacitors Portfolio Medium voltage enclosed capacitor banks ABBACUS EMPAC SIKAP 1-36 kv 1-36 kv 1-24 kv + - Control Equipment & Switchgear Complete with switchgear or only capacitor bank June 19, 2013 Slide 35

ABB MV & HV Capacitors Portfolio MV enclosed capacitor bank type ABBACUS Type: One enclosure = Several steps Voltage Range: Power Range: Switching: Protection degree: Capacitor units: Connection Installation: Temperature range: ABBACUS Enclosed mult-step switched cap. bank Max. 36 kv Up to 20 Mvar Yes IP65 Capacitors units equipped with internal fuse and discharging resistor. Single or Double Star Indoor/Outdoor -50 to +55 C (up to 24 kv) -10 to +55 C (36 kv) Delivered with all internal electrical wiring between capacitors; CT and reactors (if included) pre connected / factory assembled June 19, 2013 Slide 36

ABB MV & HV Capacitors Portfolio MV enclosed capacitor bank type EMPAC Type: One enclosure = One step Voltage range: Power & Voltage range in one single step; Switching: Protection degree IP 44 Capacitor units: Connection: Installation Temperature range: EMPAC Enclosed switched MV Capacitor Bank Max. 36 kv Up-to 24 kv 1 level: 7.2 Mvar Up-to 24 kv 2 levels: 10.8 Mvar 24 to 36 kv 2 levels: 14.4 Mvar Yes (Optional) Capacitors units equipped with internal fuse and discharging resistor. Double star Indoor or Outdoor -25 to +40 C Delivered with all internal electrical wiring between capacitors; CT and reactors (if included) are pre-connected/factory assembled June 19, 2013 Slide 37

ABB MV & HV Capacitors Portfolio MV enclosed capacitor bank type SIKAP Type: One enclosure = One step Voltage Range: SIKAP Enclosed MV non-switched capacitor bank 4.5-24 kv Power Range: Switching: Protection degree: Capacitor units: Connection Installation: Temperature range: Up to 18 Mvar No IP44 Capacitors units equipped with internal fuse and discharging resistor. Single or Double Star Indoor/Outdoor -40 to +40 C Origin: Sweden Delivered with all internal electrical wiring between capacitors, CT and reactors (if included) pre-connected/factory assembled June 19, 2013 Slide 38

ABB MV & HV Capacitors Portfolio MV & HV Product Range: Main ratings ABBACUS EMPAC SIKAP Q-POLE Q-BANK MV Metal enclosed capacitor banks Control equipment and switchgear Pole-mounted MV bank MV & HV open-rack capacitor banks Application: var compensation Harmonic filtering Installation Yes Yes (1) Indoor & outdoor Yes Yes (2) Indoor & outdoor Yes Yes (2) Indoor & outdoor Yes No Outdoor Yes Yes Indoor & outdoor Frequency 50 and 60 Hz 50 and 60 Hz 50 and 60 Hz 50 and 60 Hz 50 and 60 Hz Voltage Up to 36 kv Up to 36 kv Up to 24 kv Up to 36 kv Up to 800 kv Max. total reactive power @50 Hz 20 Mvar 14.4 Mvar 18 Mvar 3.6 Mvar Undefined (limited by design) Multi-step Max. power per step Yes (Up to 8) Up to 5 Mvar No - No - No - No - IP 65 44 44 00 00 Temperature range -50 to +55 C -25 to +40 C -40 to +40 C -50 to +55 C -50 to +55 C Applicable standards IEC 60871-1, IEC 60871-4, IEEE 18, Others on request 1) Mostly for detunned filtering, in order to prevent resonance issues. Small tunned filters can also be used, mostly with filter buliding blocks (reactors and resistors) installed separated and not in the enclosure. 2) Can be used for tunned filters with filter buliding blocks (reactors and resistors) installed separated and not in the enclosure. June 19, 2013 Slide 39

ABB MV & HV Capacitors Portfolio MV & HV Product Range: Main features & accessories ABBACUS EMPAC SIKAP Q-POLE Q-BANK Switched multi-step bank MV Metal enclosed capacitor banks Control equipment and switchgear Pole-mounted MV bank Relays var MV & HV open-rack capacitor banks Protection Unbalance (1) (1) (1) Switching Contactors & switches (1 per step) (1 per bank) (1 per bank) For HV only Circuit breaker & accessories (1 per step) (1 per bank) MV fuse-link protection Earthing switch Reactors Inrush Detuned Filter (1) (1) (1) Instrument Transformers Unbalanace CT Protection CTs Protection VTs Rapid-discharge VT s (1) Supplied loose and installed separately June 19, 2013 Slide 40

ABB MV & HV Capacitors Portfolio Pole-mounted MV capacitor bank Type: Voltage Range: Power Range: Switching: Protection degree: Capacitor units: Connection: Installation: Q-POLE Pole mounted capacitor bank Up to 36 kv Up to 3.6 Mvar Yes IP00 Capacitors units equipped with discharging resistor. Designed from voltage and system grounding Outdoor Temperature range: -50 to +55 C Delivered with all electrical wiring between capacitors; Controller, CS, PT and reactors (if included) are pre-connected/factory assembled June 19, 2013 Slide 41

ABB MV & HV Capacitors Portfolio MV & HV open-rack capacitor bank type QBANK Type: Voltage Range: Power Range: Structures Mechanics Connection: QBANK Open-rack capacitor bank 1-800 kv 0.5-300 Mvar Temperature range: -50 to +55 C Installation: Hot-dip galvanized steel, copper bars and wires, porcelain support insulators Designed for wind, snow, seismic requirements, etc. Designed from voltage and system grounding Indoor or outdoor, side-by-side or stacked Delivered mounted and connected as far as possible in the factory (excluding support insulators) QBANK-A QBANK-B QBANK-C June 19, 2013 Slide 42

ABB MV & HV Capacitors Portfolio MV & HV open-rack capacitor bank type QBANK Slide 1

ABB MV & HV Capacitors Portfolio Harmonic filters type CHARM Type: CHARM Tuned or detuned design: Tuned filters: Suitable when source of harmonics, and harmonic content is well defined De-tuned filters: Suitable when harmonics originate from many sources, and many harmonic frequencies are present Band-pass, High-pass or C-type filters Voltage Range: 1-800 kv Power Range: Defined by needs Temperature range: -50 to + 55 C Band-pass L + C High-pass L // R + C C-type (L+C2) // R + C1 (filter with extra low fundamental losses) June 19, 2013 Slide 44

ABB MV & HV Capacitors Portfolio Dynamic compensation: SVC SVC With dynamic compensation following additional features will be achieved: Fast voltage fluctuation (Flicker) Phase asymmetric loads Continuous power factor control 220 kv 90 MVA Typical application is fast changing loads These applications need SVC Power Range: Defined by needs TCR 135 Mvar 5: a 51 Mvar 7: o 29 Mvar 11: e 10 Mvar June 19, 2013 Slide 45

ABB MV & HV Capacitors Portfolio Surge capacitors and motor surge protection Surge Capacitors & MSP Protection against power surges, switching transients, faults, and lightning strikes mainly for critical industrial loads: Large Motors and generators; Large transformers; MV switchgear and motor control centers Surge capacitor 1 phase or 3 phases The primary function of the Type MSP motor surge protector is to guard the winding insulation of the device being protected. Voltage Range: Availability: 2.4-24 kv Standard units kept in stock Motor Surge Protector (MSP) Includes surge capacitor and surge arrester June 19, 2013 Slide 46

ABB MV & HV Capacitors Portfolio Switching: Capacitor switch PS range PS15 (15 kv) PS36 (36 kv) Up to 400 A ABB vacuum interrupter technology Magnetic actuator Mechanical or electrical latching NO oil, gas or foam Maintenance free Hydrophobic cycloaliphatic epoxy (HCEP) resin insulator June 19, 2013 Slide 47

ABB MV & HV Capacitors Portfolio Capacitor Switch: CQ900 range CQ900 Range User friendly interface Extensive range of control modes Measurement & monitoring Data logging Protection Communication: DNP3, IEC 61850 Easy programming & commissioning Durable IP54 power coated stainless steel enclosure June 19, 2013 Slide 48

ABB MV & HV Capacitors Portfolio Synchronized switching: Switchsync TM relays Switchsync Range Voltage transients when energizing one phase of a 72 kv capacitor bank Controlled switching of the capacitor bank breaker gives efficient reduction of the switching transients Well proven Switchsync TM controllers ABB s circuit breakers are well suited Damping reactors are normally superfluous A B A: Energizing close to the power frequency voltage peak. A high voltage transient is generated B: With Switchsync relay. Energizing close to voltage zero. The transient is considerably reduced Energizing of capacitor banks and harmonic filters may cause severe inrush currents and voltage oscillations June 19, 2013 Slide 49

ABB MV & HV Capacitors Portfolio Metering & Maintenance: CB2000 Capacitance Bridge Type CB2000 Developed for capacitor measurements in HV capacitor banks Easy to use and handle Data collection & storage No disconnections in the bank Shorter service operations No disconnections required in the capacitor bank during measurement June 19, 2013 Slide 50

High Voltage Capacitors Documentation June 19, 2013 Slide 51

Documentation Catalogues Download from abb.com/highvoltage June 19, 2013 Slide 52

June 19, 2013 Slide 53