Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point 0...95



Similar documents
225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Quick running actuator

Air damper actuators

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Electric Rotary Actuator - On/Off or programmable control actuator

PNOZsigma - Base units

HERZ-Thermal Actuators

VAV compact controller KNX / PL-Link

VAV compact controller KNX / PL-Link

Analog signal converters CC-E I/I Current / current isolators

Redundancy Module QUINT-DIODE/40

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

3-phase, bidirectional energy meter

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

E-STOP relays, safety gate monitors

Product and functional description

48 SERIES Relay interface modules 10 A

80 Series - Modular timers 16 A. Features

Safety automation solutions

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

OTM_F_C_. Installation instruction 34OTM_F_C_ / 1SCC303009M0201

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

E-STOP relays, safety gate monitors

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

RM4TG20 three-phase network control relay RM4-T - range V

VAV system solution for non-pressure-dependent applications in enclosed spaces

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Electronic overload relay EF65, EF96 and EF146

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Electronic Control Devices The European Product Catalogue 2007

Contact expander modules

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

E-STOP relays, safety gate monitors

Technical catalogue. Modular DIN rail components Installation contactors

PHOENIX CONTACT Features

Contact expansion modules

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

E-STOP relays, safety gate monitors

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Electronic overload relay EF19 and EF45

E-STOP relays, safety gate monitors

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

SMOKE DAMPERS IMOS DKI-1 TECHNICAL CONDITIONS TPI (DAMPERS FOR EMISSION EXHAUST) FOR ONE FIRE AREA

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

38 Series - Relay interface modules A

Installation & User Instructions

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal T [] C

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

Actuator for modulating control AME 435

Digital input modules

80 Series - Modular timers 16 A. Features

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Electronic Control Devices The European Product Catalogue 2007

Quick Connect. quick - simple - efficient.

49 Series - Relay interface modules A. Features

38 Series - Relay interface modules A

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

E-STOP relays, safety gate monitors

Safety technique. Emergency stop module BO 5988 safemaster

Three-phase monitoring relay CM-PFE

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

13 SERIES. Electronic step relays A

RY2 miniature industrial relays

GLYDEA TM DIRECT DRIVE MOTORIZED CURTAIN TRACK SPECIFICATION DOCUMENT

Reaction Torque Sensor

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

ELECTROMAGNETIC DISC BRAKES

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Drayton Digistat +2RF/+3RF

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

Thermal-Magnetic Circuit Breaker M1-..

TX OPEN RS232/485 module

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

EBS852 (Contrac) Power Electronic Unit

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

5SV Residual Current Protective Devices

Transcription:

Actuators Technical data sheet 227S-230-05-S1 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5 Nm Nominal Voltage 230 VAC/DC Control 2/3 Point Connection Auxiliary switch S1 1x freely adjustable Damper size up to approx. 1 m² Damper coupling Clamp 8-12 mm / Ø 8-16 mm Technical data Nominal voltage Nominal voltage 230 VAC/DC Nominal voltage range 85...265 VAC/DC Power consuption Motor (Motion) 2,5 W Power consuption Standby (end position) 1,0 W Wire sizing 4,0 VA Control 2/3 Point Position feedback - Auxiliary switch 1 x SPDT(Ag) Contact load 5 (2,5) A, 250 VAC Switching point 0...95 Connection Motor Cable 1000 mm, 3 x 0,75 mm² (halogen free) Connection Auxiliary switch Cable 1000 mm, 3 x 0,75 mm² (halogen free) Connection Position feedback - Connection GUAC - Functional data Torque Motor >5 Nm Synchronised speed - Direction of rotation selected by switch Manual override Gearing latch disengaged with pushbutton, self-resetting Angle of rotation 0... max. 95 can be limited with adjustable mechanical end stop min 20. Running time Motor < 20...35 s / 90 Sound power level Motor < 45 db(a) Damper coupling Clamp 8-12 mm / Ø 8-16 mm 2013-03-08 12:19:10 Copyright by GRUNER AG Subject to change in technology and Design 1

Technical data Functional data Position indication mechanical with pointer Service life >60'000 cycles (0-95 - 0 ) Safety Protection class II (double insulation) Degree of protection IP54 (Cable downwards) EMC CE (2004/108/EG) LVD CE (2006/95/EG) RoHS CE (2011/65/EU) Mode of operation Typ 1 (EN 60730-1) Rated impulse voltage 4 kv (EN 60730-1) Control pollution degree 3 (EN 60730-1) Ambient temperature Normal operation -30...+50 Storage temperature -30...+80 Ambient humidity 5...95% r.f., non- condensating (EN 60730-1) Maintenance maintenance free Dimensions/ Weight Dimensions 115 x 65 x 61 mm Weight ca. 530 g Operating mode / Properties Operating mode 2- point. Through connecting the power supply to BU+BN (1+2) and the direction of rotation switch on position R moves the actuator to position 1. Is also BK (1+2+3) connected to the power supply the actuator is moving to position 0. 3- point. Through connecting the power supply to BU+BN (1+2) and the direction of rotation switch on position R moves the actuator to position 1. If the power supply is interrupted the actuator maintains its current position. Is also BU+BK (1+3) connected to the power supply the actuator is moving in direction 0. The actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached. Direct mounting Simple direct mounting on the damper spindle with a universal spindle clamp, supplied with an anti-rotation strap to prevent the actuator from rotating. Manual override Manual override is possible with the self-resetting pushbutton (the gearing latch remains disengaged as long as the pushbutton is pressed) Rotary direction switch R= clockwise L= counter clockwise 2013-03-08 12:19:11 Copyright by GRUNER AG Subject to change in technology and Design 2

Connection / Safety remarks Safety remarks -Attention mains voltage -The actuator is not allowed to be used outside the specified field of application, especially in airplanes. -In may only be installed by suitably trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. -The device may only be opened at the manufacturer s site. -When calculating the required torque, the specifications supplied by the damper manufacturers (cross- section, design, installation site), and the air flow conditions must be observed. -The actuator is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. 2013-03-08 12:19:11 Copyright by GRUNER AG Subject to change in technology and Design 3

Technical drawing 2013-03-08 12:19:12 Copyright by GRUNER AG Subject to change in technology and Design 4

Powered by TCPDF (www.tcpdf.org) 227S-230-05-S1 Gruner AG post office box (P.O.Box) 1149 D-78564 Wehingen Tel. +49 7426 948-0 Fax +49 7426 948-200 www.gruner.de info@gruner.de 5 2013-03-08 12:19:12 Copyright by GRUNER AG Subject to change in technology and Design