ACTIFLO Process For Wet Weather and Wastewater Treatment



Similar documents
Physical Chemical Phosphorous Removal

Technical Feasibility of a Wet Weather Flow Treatment Facility

Appendix 2-1. Sewage Treatment Process Options

Municipal Standard Solutions. Water Treatment WATER TECHNOLOGIES

PRETREATMENT PROCESSES FOR POTABLE WATER TREATMENT PLANTS

William E. Dunn Water Reclamation Facility. Facility Overview & Information

Flexible Microscreen Filter. Hydrotech Discfilter

ADVANCED LAGOON TREATMENT TECHNOLOGIES FOR WASTEWATER TREATMENT

Wastewater Nutrient Removal

CHAPTER 8 UPGRADING EXISTING TREATMENT FACILITIES

Facility Classification Standards

WISCONSIN WASTEWATER OPERATORS ASSOCIATION

SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS

CFD Modeling as a Tool for Clarifier Design

Reactor Clarifier Solids Contact Clarifiers

Cambridge Wastewater Treatment Facility

WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )

Small Wastewater Treatment Systems

Description of the Water Conserv II Facility

Phosphorus Removal. Wastewater Treatment

WASTEWATER TREATMENT OBJECTIVES

Sewerage Management System for Reduction of River Pollution

Phosphorous Reduction in the Assabet River

Residuals Management Somersworth Drinking Water Treatment Facility. Ian Rohrbacher, Treatment Operator IV

Provided below is a description of the processes generating wastewater in a poultry plant and a typical pretreatment and full treatment system.


Module 16: The Activated Sludge Process - Part II Instructor Guide Answer Key

SMALL COMMUNITY TREATMENT PLANT EXPANSION WHILE IN OPERATION USING ADVANCED TECHNOLOGY

OPTIMIZING BIOLOGICAL PHOSPHORUS REMOVAL FROM AN SBR SYSTEM MIDDLEBURY, VT. Paul Klebs, Senior Applications Engineer Aqua-Aerobic Systems, Inc.

MEMBRANE TECHNOLOGY TREATING OILY WASTEWATER FOR REUSE

THE MC CLARIFLOW UPFLOW SOLIDS CONTACT CLARIFIER

Advanced Wastewater Treatment and Disposal Systems. Water and Wastewater Utility Operation and

Bay Park Sewage Treatment Plant Super Storm Sandy Recovery

Biological Wastewater Treatment

Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service

aquateam Aquateam - Norwegian Water Technology Centre A/S Report no: Project no: O Project manager: Dr. Bjørn Rusten.

Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS

Membrane Bioreactor Performance Compared to Conventional Wastewater Treatment

Development of Advanced Wastewater Treatment and Reclamation System

HUBER Vacuum Rotation Membrane VRM Bioreactor

Glossary of Wastewater Terms

The South Central Regional Wastewater

Total Water & Wastewater Management for Shale Gas Production. Treatment and Operation Solutions

POTW PHOSPHORUS REMOVAL PROCESSES

Appendix F Use of spill basin to further reduce final effluent variability - report

Removing Heavy Metals from Wastewater

Water Recycling in action in South Australia: a review of agricultural and municipal reuse schemes and innovation.

Environmental Technology March/April 1998

Floating Treatment Wetland Technology: Nutrient Removal from Wastewater

Brewery Wastewater: 2010 Water and Wastewater Conference Page 1

ENVIRONMENTAL ISSUES IN THE RENDERING INDUSTRY. Gregory L. Sindt, P.E. Environmental Engineer Bolton and Menk, Inc.

Mine Water Treatment Solutions for Discharge and Re-Use

5. TREATMENT FACILITIES

How To Water System

MALAYSIA S REQUIREMENTS ON INDUSTRIAL EFFLUENT TREATMENT SYSTEMS -The WEPA Workshop and Annual Meeting February 2013 Siem Reap, Combodiaby

Occurrence and implication of dissolved organic phosphorus (DOP) in

Holistic Aeration and Chemical Optimization Saves Big Money from 1 MGD to 600 MGD. Trevor Ghylin, PE PhD

1.85 WATER AND WASTEWATER TREATMENT ENGINEERING FINAL EXAM DECEMBER 20, 2005

COURSE # 343 UNIT # 1: ADVANTEX WASTEWATER TREATMENT SYSTEM. What you will learn in this lesson. Introduction to the listing

Town of New Castle Utility Department Introduction

INFILCO DEGREMONT WATER + WASTEWATER TREATMENT GUIDE

The City of Boulder 75 th Street Wastewater Treatment Facility

High-Rate Retention Treatment Facility for CSO Control in Windsor Riverfront East

Minnesota. BMI Project No. M

Water Water Treatment Plant Tour

ROSS Technology Removal of Oil, Solids and Scale Formers

Module 17: The Activated Sludge Process Part III

Texas Commission on Environmental Quality Page 1 Chapter Design Criteria for Domestic Wastewater Systems


CWD BALDWIN PLANT NEW RESIDUALS HANDLING SYSTEM

Biological wastewater treatment plants of BIOGEST

A NOVEL ION-EXCHANGE/ELECTROCHEMICAL TECHNOLOGY FOR THE TREATMENT OF AMMONIA IN WASTEWATER

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

MUNICIPAL WASTEWATER TREATMENT PLANT ENERGY EVALUATION FOR ITHACA AREA WASTEWATER TREATMENT FACILITY

Engineers Edge, LLC PDH & Professional Training

ADVANCED TREATMENT TECHNOLOGIES FOR RECYCLE/REUSE OF DOMESTIC WASTEWATER

The Sewage Plant. The Original! Fully biological. Small sewage. wastewater treatment for. new construction. & retrofitting

Products, systems and services for water and wastewater treatment plants Enhanced plant performance, efficiency and reliability

TREATMENT OF SANITARY SEWER OVERFLOW

BROWN AND CALDWELL. Appendix G. Data for DAFT Experiments

Active Treatment Systems

COD/BOD 5 Reduction with ROTAMAT Fine and Micro Screens

Coagulation and Flocculation

Enhancing Nitrification in an Oil Refinery WWTP with IFAS

Nutrient Removal at Wastewater Treatment Facilities. Nitrogen and Phosphorus. Gary M. Grey HydroQual, Inc X 7167

Water Specialists for the Petrochemical Sector. ovivowater.com. creating value in water through innovation, creativity and expertise

Sustainable Water Management. for the Power Industry

1.782 Environmental Engineering Masters of Engineering Project

Pursuant to Department of Environmental Protection Rules Chapter 555, effective March 9, 2009

Solids Capture. Brian Vinci, Ph.D. James M. Ebeling, Ph.D. Freshwater Institute Shepherdstown, WV

John D. Dyson, Manager Municipal Water Group Infilco Degremont Inc. Richmond, VA

SECONDARY TREATMENT ACTIVATED SLUDGE

City of East Lansing CSO Control Facility Evaluation Demonstrative Approach to Meet WQS

DOMESTIC WASTEWATER SYSTEMS

EXISTING WASTEWATER TREATMENT FACILITIES

Ion Exchange Softening

-O^ DEQ. National Pollutant Discharge Elimination System PERMIT EVALUATION AND FACT SHEET November 12,2003

Transcription:

ACTIFLO Process For Wet Weather and Wastewater Treatment

ACTIFLO Microsand Ballasted Clarification Process ACTIFLO is a high rate, compact process developed by Veolia Solutions & Technologies. The process operates with microsand which enhances floc formation and acts as a ballast to aid in rapid settlement of coagulated material. The ACTIFLO process can be used at various stages of wastewater treatment including: enhanced primary treatment, wet weather clarification, high rate secondary clarification and final polishing for the removal of solids, phosphorus and metals. Typical ACTIFLO Performance Application Loading Rates Phosphorus sbod BOD 5 TSS UV Transmittiance gpm/sf (mg/l) (mg/l) (mg/l) (mg/l) (%) Wet Weather 60 0.5-1.5 10-20 < 30 < 20 50-70 *BIOACTIFLO 45 0.1-1.0 1-10 < 20 < 15 60-70 Secondary 20 0.5-1.5 1-10 < 10 < 10 65-75 Tertiary 45 as low as 0.05 < 10 < 10 < 5 75-90 *Pathogen removal, post disinfection, is equivalent to or exceeds that of a conventional activated sludge plant ACTIFLO : Compactness Displaying Its True Potential The microsand ballasted flocs display unique settling characteristics, which allow for clarifier designs with very high overflow rates and short retention times. These designs result in footprints that are 5 times smaller lamella clarifiers or dissolved air flotation (DAF) and up to 20 times smaller than conventional clarification systems. Flat bottom clarifier 0.2-0.6 gpm/sf blanket clarifier 47.5 MGD blanket clarifier 1.6 gpm/sf DAF or lamella clarifier 4-6 gpm/sf ACTIFLO 35-60 gpm/sf ACTIFLO 47.5 MGD * Surface water treatment reference

CSO/SSO Parallel Treatment with ACTIFLO Recirculation: settled material is pumped to the hydrocyclone for separaration and microsand recovery Ballasted Flocs to Hydrocyclone Hydrocyclone Microsand Coagulant Raw Coagulation Maturation Settling Tank with Scraper Clarified Sand Recirculation Pumps Coagulation tank: pin floc formation Injection tank: ballasted floc formation begins and microsand is re-injected Maturation tank: ballasted floc formation continues with optimum mixing gradients During peak wet weather flow conditions, many plants need to divert a portion of the total plant flow around their biological treatment process. To achieve high levels of TSS and particulate BOD removal of these diverted excess flows, the ACTIFLO process can be installed at the treatment plant or at a satellite facility within the collection system. The ACTIFLO process can be fully automated and the process train(s) can sit idle for extended periods of time and still be fully operational within 15 minutes of start-up. CSO/SSO Treatment BIOACTIFLO INFLUENT ACTIVATED SLUDGE SYSTEM EFFLUENT If flow diversion is not an option or the TSS and particulate BOD removal with ACTIFLO alone are not enough, a biological solids contact tank can be incorporated into the treatment flow path to improve soluble BOD removal through the system. INFLUENT SOLIDS CONTACT TANK RAS ACTIFLO EFFLUENT Return activated sludge (RAS) from the existing clarifiers is combined with the excess flows into a solids contact tank. A targeted mixed liquor suspended solids (MLSS) concentration is maintained in the contact tank to facilitate rapid uptake of soluble biological oxygen demand (BOD) via contact stabilization. Clarification with ACTIFLO follows, producing exceptional TSS and total BOD removal rates that allow for efficient disinfection.

Tertiary Treatment with ACTIFLO With tighter discharge limits being imposed on wastewater treatment plants the need for a cost effective, flexible process has evolved. Over the years, the ACTIFLO process has proven its effectiveness in meeting extremely low phosphorus, metals and TSS limits. Microsand Ballasted Flocs to Hydrocyclone HYDROCYCLONE Coagulant Service Microsand Polymer Baffle Clarified Raw Splitter Thickened Discharge COAGULATION TANK FLOCCULATION TANK WITH TURBOMIX TM SETTLING TANK WITH LAMELLA AND SCRAPER EXTERNAL SLUDGE RECIRCULATION (HCS SYSTEM) RECIRCULATION PUMP Process Benefits Small process footprint; suited for restricted spaces and existing basin retrofits Low system headloss, incorporates into most existing hydraulic profiles Reduced civil engineering costs High degree of operational flexibility Short start-up time < 15 minutes Minimum equipment to maintain, all easily accessible For tertiary treatment applications, the ACTIFLO process offers: Reduce coagulant demand by recirculating a portion of the sludge back to the coagulation tank Ability to treat a wide range of influent phosphorus levels to extremely low limits Flexibility to meet future limits (phosphorus, metals) without modifying the process train The same tertiary treatment trains can also be used to treat wet weather flows Treatment of flows with high solids concentration without impacting effluent quality (solids washout from secondary clarifiers during peak flow) Reduction in sludge volume by incorporating a HCS system

Worldwide References The ACTIFLO process is currently in operation worldwide in small communities and large metropolitan areas, as well as in various installations for the treatment of industrial process water and effluents. Syracuse, NY Onondaga County wastewater treatment plant Kaukauna, WI Heart of Valley wastewater treatment facility Geneva, Switzerland Aire wastewater treatment plant ACTIFLO for tertiary polishing and phosphorus removal downstream of biofiltration (BIOSTYR ) 126 MGD achieving < 0.10 mg/l Total P SSO/Primary, ACTIFLO followed by BIOSTYR 60 MGD Nominal, 2 x 30 MGD 70 MGD Peak Capacity, 2 x 35 MGD ACTIFLO for primary, wet weather and biofilter backwash water treatment (BIOSTYR ) 137 MGD Lawrence, KS Lawrence wastewater treatment plant ACTIFLO for wet weather flow treatment 40 MGD Barcelona, Spain Baix Llobregat municipal wastewater reuse plant Reuse of 5 millions m/year of treated water for irrigation ACTIFLO for tertiary treatment upstream of disc filtration 79.8 MGD Paris, France Seine-Aval wastewater treatment plant Sydney, Australia Illawarra wastewater reclamation plant ACTIFLO for wet weather treatment or tertiary treatment (dry weather) 686.8 MGD ACTIFLO for wet weather treatment upstream of UV disinfection 84.5 MGD

Kruger Inc. Phone 919.677.8310 Fax 919.677.0082 www.krugerusa.com krugerincmarketing@veoliawater.com Kruger Marketing 13-1