Inductive slot sensor



Similar documents
Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Inductive sensor NI10-M18-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Solenoid Valve Island Type 3965

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Design of intrinsically safe systems

Plug and Socket Devices CES 63 A Series 8579

2.12. page Products for Explosion hazardous Environment

Compact pressure switch Flameproof enclosure Ex d Model PCA

SEISMIC VELOCITY TRANSDUCER T1-40

Instructions for Safe Use

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Terminal Box. Specifications TNCN

SAFETY MANUAL SIL Switch Amplifier

Explosion proof enclosures

Safety instructions VEGADIS DIS81.CEIA/V****

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Series 8146/5-V37 and Series 8150/5-V37

RM4TG20 three-phase network control relay RM4-T - range V

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Plug and Socket Devices SolConeX 16 A Series 8570

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

A good connection. International approvals.

SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M

3500/62 Process Variable Monitor

type V46, solenoid or pneumatic operated

MINI MCR-SL-R-UI(-SP)

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Technical Information RIA14

TTF300 Field-mount temperature transmitter

Safety technique. Emergency stop module BO 5988 safemaster

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

FP2 Relay. The Best Relaytion

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Redundancy Module QUINT-DIODE/40

Control and Distribution Boxes made of Stainless Steel Series 8150

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Thermistor motor protection

S-series Mass Connection Solutions

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Relative pressure transmitter type 520

SAFETY MANUAL SIL SWITCH AMPLIFIER

Operating Instructions

Differential-Hall-Effect based Sensors Series A5S Overview

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Terminal Boxes Series 8146

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Cross-beam scanning system to detect slim objects. 100 mm in

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Series 3730 Type Electropneumatic Positioner

SAFETY MANUAL SIL RELAY MODULE

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Flow switches Series AD/VH

FGM 160 ATEX EC type examination certificate

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Three-phase monitoring relay CM-PFE

Inductive sensors. Compact, fast, reliable. Edition 2013

Series 3730 Type Electropneumatic Positioner with FOUNDATION fieldbus communication


UM-X Field display for continous level sensors

Linear Luminaire with LED Series EXLUX 6402/2

ISpac isolators. the perfect system

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

R.C.C.B. s two-pole LEXIC

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

INTERNATIONAL STANDARD

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

Wanner International and ATEX Directive 94/9/EC Covers - Category 2 Zone 1 and Category 3 Zone 2 requirements

Magnetic proximity switches

EPHY-MESS GmbH phone: Berta-Cramer-Ring 1 fax: Wiesbaden info@ephy-mess.de Germany

Worcester DS/DM Series UltraSwitch Switch box

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

Safety Relays ESM/ESM-F

Transcription:

0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product s documentation. Technical Data specifications Switching element function NAMUR, NC Slot width 3.5 mm Depth of immersion (lateral) 5... 7 typ. 6 mm Installation Output polarity Safety Function Nominal ratings Nominal voltage U o 8 V Switching frequency f 0... 3000 Hz Hysteresis H with NAMUR switch amplifier: 0.045 mm (e. g. Pepperl+Fuchs KCD2-SR-Ex1.LB) with safety switch amplifier 0.025 mm (e. g. Pepperl+Fuchs KFD2- SH-Ex1) Suitable for 2:1 technology yes, with reverse polarity protection diode Rate of current rise -4.5 ma / mm Current consumption Measuring plate not detected 3 ma Measuring plate detected 1 ma Functional safety related parameters MTTF d 7970 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Ambient conditions Ambient temperature -50... 100 C (-58... 212 F) Safety application: -40... 100 C Mechanical specifications Connection type flexible leads LiY, 500 mm Core cross-section 0.14 mm 2 Housing material PBT Degree of protection Note IP67 adjustable stop Security relevant only up to -40 C information Use in the hazardous area see instruction manuals Category 1G; 2G; 3G; 1D Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Standards EN 60947-5-2:2007 IEC 60947-5-2:2007 Approvals and certificates FM approval Control drawing 116-0165 UL approval culus Listed, Purpose CSA approval ccsaus Listed, Purpose CCC approval CCC approval / marking not required for products rated 36 V Dimensions 3.5 5 10 15 0.9 6.95 19 2 Electrical Connection 10 BN BU ø 1.85 L+ L- 3 1

ATEX 1G Device category 1G II 1G Ex ia IIC T6 T1 Ga Ignition protection "Intrinsic safety"... 100 µh ; a cable length of 10 m is considered. and in this instruction manual. The has to be observed. The special conditions must be adhered to! Directive 94/9/EC and therefore the EC-type-examination certificates generally apply only to the use of electrical apparatus under atmospheric conditions. Ambient temperature ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1!!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Because of the risk of ignition, which can occur due to faults and/or transient currents in the equipotential bonding system, galvanic isolation is preferable in the supply and signal circuits. Associated apparatus without electrical isolation can only be used if the corresponding requirements of IEC 60079-14 are satisfied. Install the device in such a way that the resin surface is not exposed to mechanical hazards. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. 2

ATEX 2G Device category 2G II 1G Ex ia IIC T6 T1 Ga Ignition protection "Intrinsic safety"... 100 µh ; a cable length of 10 m is considered. and in this instruction manual. The has to be observed. The special conditions must be adhered to! Directive 94/9/EC and therefore the EC-type-examination certificates generally apply only to the use of electrical apparatus under atmospheric conditions. Maximum permissible ambient temperature T amb ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. related apparatus and according to the proof of intrinsic safety. Install the device in such a way that the resin surface is not exposed to mechanical hazards. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. 3

ATEX 3G (ic) Device category 3G (ic) Certificate of Compliance CE marking PF 13CERT2895 X II 3G Ex ic IIC T6 T1 Gc Ignition protection category "ic" 30 nf ; A cable length of 10 m is considered. for Pi=34 mw, Ii=25 ma, T6 for Pi=34 mw, Ii=25 ma, T5 for Pi=34 mw, Ii=25 ma, T4-T1 for Pi=64 mw, Ii=25 ma, T6 for Pi=64 mw, Ii=25 ma, T5 for Pi=64 mw, Ii=25 ma, T4-T1 for Pi=169 mw, Ii=52 ma, T6 for Pi=169 mw, Ii=52 ma, T5 for Pi=169 mw, Ii=52 ma, T4-T1 for Pi=242 mw, Ii=76 ma, T6 for Pi=242 mw, Ii=76 ma, T5 for Pi=242 mw, Ii=76 ma, T4-T1 Connection parts 100 µh ; A cable length of 10 m is considered. and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! must be observed. The sensor must only be operated with energy-limited circuits, which satisfy the requirements of IEC 60079-11. The explosion group complies with the connected, supplying, power limiting circuit. Install the device in such a way that the resin surface is not exposed to mechanical hazards. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion! 70 C (158 F) 85 C (185 F) 100 C (212 F) 66 C (150.8 F) 81 C (177.8 F) 100 C (212 F) 45 C (113 F) 60 C (140 F) 89 C (192.2 F) 30 C (86 F) 45 C (113 F) 74 C (165.2 F) The sensor must not be mechanically damaged. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. 4

ATEX 1D Device category 1D for use in hazardous areas with combustible dust II 1D Ex ia IIIC T135 C Da Ignition protection "Intrinsic safety"... 100 µh A cable length of 10 m is considered. Permissible ambient temperature range and in this instruction manual. The has to be observed. Directive 94/9/EC and therefore the EC-type-examination certificates generally apply only to the use of electrical apparatus under atmospheric conditions. ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. related apparatus and according to the proof of intrinsic safety. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. Electrostatic charge Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up. 5