Technical Data. General specifications Switching element function Rated operating distance s n 4 mm



Similar documents
Inductive slot sensor

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Inductive sensor NI10-M18-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Solenoid Valve Island Type 3965

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Series 8146/5-V37 and Series 8150/5-V37

Plug and Socket Devices CES 63 A Series 8579

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

2.12. page Products for Explosion hazardous Environment

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Plug and Socket Devices SolConeX 16 A Series 8570

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

SEISMIC VELOCITY TRANSDUCER T1-40

Instructions for Safe Use

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Compact pressure switch Flameproof enclosure Ex d Model PCA

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Terminal Box. Specifications TNCN

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

A good connection. International approvals.

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Terminal Boxes Series 8146

Safety instructions VEGADIS DIS81.CEIA/V****

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Technical Information RIA14

Design of intrinsically safe systems

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Explosion proof enclosures

Control and Distribution Boxes made of Stainless Steel Series 8150

Linear Luminaire with LED Series EXLUX 6402/2

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

MINI MCR-SL-R-UI(-SP)

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

Differential-Hall-Effect based Sensors Series A5S Overview

SAFETY MANUAL SIL Switch Amplifier

EPHY-MESS GmbH phone: Berta-Cramer-Ring 1 fax: Wiesbaden info@ephy-mess.de Germany

Technical data sheet TDS0070

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

TTF300 Field-mount temperature transmitter

Operating Instructions

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

type V46, solenoid or pneumatic operated

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

S-series Mass Connection Solutions

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Safety technique. Emergency stop module BO 5988 safemaster

FGM 160 ATEX EC type examination certificate

Power Supplies 3. SDN-P DIN Rail Series

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Flow switches Series AD/VH

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

FP2 Relay. The Best Relaytion

3DLevelScanner II TECHNICAL DATA SHEET

Relative pressure transmitter type 520

UM-X Field display for continous level sensors

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Floodlight Range Installation Guide

Digital input modules

3/2-way Solenoid Valve, direct-acting, NC or NO

Fluxi 2000/TZ Turbine Gas Meter

TEIP11 I/P signal converter for standard signals. Measurement made easy

1756 ControlLogix Chassis Specifications

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Worcester DS/DM Series UltraSwitch Switch box

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

RM4TG20 three-phase network control relay RM4-T - range V

SAFETY MANUAL SIL RELAY MODULE

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Safety instructions VEGAPULS PSWL61. KX***H***

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)


Cross-beam scanning system to detect slim objects. 100 mm in

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Transcription:

0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product s documentation. Accessories BF 12 Mounting flange, 12 mm EXG-12 Quick mounting bracket with dead stop Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 4 mm Installation non-flush Output polarity Safety Function Assured operating distance s a 0... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage U o 8 V DC Switching frequency f 0... 1500 Hz Current consumption Measuring plate not detected 3 ma Measuring plate detected 1 ma Ambient conditions Ambient temperature -50... 100 C (-58... 212 F) Safety application: -40... 100 C Mechanical specifications Connection type cable silicone, 2 m Core cross-section 0.34 mm 2 Housing material PP Sensing face PP Degree of protection IP68 Cable Bending radius > 10 x cable diameter Note Security relevant only up to -40 C information Use in the hazardous area see instruction manuals Category 1G; 2G; 3G; 1D; 3D Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Standards EN 60947-5-2:2007 IEC 60947-5-2:2007 Approvals and certificates FM approval Control drawing 116-0165 UL approval culus Listed, Purpose CSA approval ccsaus Listed, Purpose CCC approval CCC approval / marking not required for products rated 36 V Dimensions M12 x 1 44 30.5 35 17 Electrical Connection BN BU L+ L- 1

ATEX 1G Device category 1G II 1G Ex ia IIC T6 T1 Ga Ignition protection "Intrinsic safety" 150 µh ; a cable length of 10 m is considered. and in this instruction manual. The has to be observed. The special conditions must be adhered to! Directive 94/9/EC and therefore the EC-type-examination certificates generally apply only to the use of electrical apparatus under atmospheric conditions. Ambient temperature ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1!!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Because of the risk of ignition, which can occur due to faults and/or transient currents in the equipotential bonding system, galvanic isolation is preferable in the supply and signal circuits. Associated apparatus without electrical isolation can only be used if the corresponding requirements of IEC 60079-14 are satisfied. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. 2

ATEX 2G Device category 2G II 1G Ex ia IIC T6 T1 Ga Ignition protection "Intrinsic safety" 150 µh ; a cable length of 10 m is considered. and in this instruction manual. The has to be observed. The special conditions must be adhered to! Directive 94/9/EC and therefore the EC-type-examination certificates generally apply only to the use of electrical apparatus under atmospheric conditions. Maximum permissible ambient temperature T amb ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. related apparatus and according to the proof of intrinsic safety. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. 3

ATEX 3G (ic) Device category 3G (ic) Certificate of Compliance CE marking PF 13CERT2895 X II 3G Ex ic IIC T6 T1 Gc Ignition protection category "ic" 150 µh ; A cable length of 10 m is considered. for Pi=34 mw, Ii=25 ma, T6 for Pi=34 mw, Ii=25 ma, T5 for Pi=34 mw, Ii=25 ma, T4-T1 for Pi=64 mw, Ii=25 ma, T6 for Pi=64 mw, Ii=25 ma, T5 for Pi=64 mw, Ii=25 ma, T4-T1 for Pi=169 mw, Ii=52 ma, T6 for Pi=169 mw, Ii=52 ma, T5 for Pi=169 mw, Ii=52 ma, T4-T1 for Pi=242 mw, Ii=76 ma, T6 for Pi=242 mw, Ii=76 ma, T5 for Pi=242 mw, Ii=76 ma, T4-T1 Connection parts and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! must be observed. The sensor must only be operated with energy-limited circuits, which satisfy the requirements of IEC 60079-11. The explosion group complies with the connected, supplying, power limiting circuit. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion! The sensor must not be mechanically damaged. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. 4

ATEX 1D Device category 1D for use in hazardous areas with combustible dust II 1D Ex ia IIIC T135 C Da Ignition protection "Intrinsic safety" 150 µh A cable length of 10 m is considered. Permissible ambient temperature range and in this instruction manual. The has to be observed. Directive 94/9/EC and therefore the EC-type-examination certificates generally apply only to the use of electrical apparatus under atmospheric conditions. ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. related apparatus and according to the proof of intrinsic safety. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. Electrostatic charge Do not attach the nameplate provided in areas where electrostatic charge can build up. 5