GSM Controller BR160GM-Gate



Similar documents
GSM Controller BR160SM-2SMT-4A-A / BR161SM-2SMT-4A-A

GSMPBX version 1.3 Datasheet

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

SMS GSM Alarm Messenger

GSM Voice Auto Dialer & SMS Sender JC-999

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

USER MANUAL V5.0 ST100

Temperature & Humidity SMS Alert Controller

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Telephone- and leased line modem for industrial applications TD-36

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

MANUAL GSM CONTROLLER

GPS/GLONASS SiRFstarV Evaluation Kit EVA5100-A

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

How To Use An Adh8012 Gsm Gprs Module With A Gsm (Gsm) Gpros (Gsp) Gpls (Geo) Gsp (Gpl) Gs

Intelligent GSM Auto-dial Alarm System User s Manual

GTR-128/GTR-129 Motorcycle/ Vehicle Tracker Quick Start Guide

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

Technical description MX-1 VB Edge

GTS-4E Hardware User Manual. Version: V1.1.0 Date:

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

LOW COST GSM MODEM. Description. Part Number

Data Sheet. Adaptive Design ltd. Arduino Dual L6470 Stepper Motor Shield V th November L6470 Stepper Motor Shield

Allen-Bradley/Rockwell

Bluetooth UART/RS232 Module

Business/Home GSM Alarm System. Installation and User Manual

GSM Gate Control 1000

USB I/O CONTROL BOX 8 relays, 8 digital I/O lines and 8 HV inputs

FM4100 USER MANUAL V1.4

Duct Humidity Transmitter

C2O CALL 2 OPEN USING YOUR CELL PHONE. Operation. Features Ready to operate Straight from the Box! O/P Changeover Contact 1.2KW

Model: DC-A2IO Advanced HVAC Controller

KTA-223 Arduino Compatible Relay Controller

PCS0100en Persy Control Services B.V. Netherlands

GSM HOME SECURITY SYSTEM

Part Number Description Packages available

UniPi technical documentation REV 1.1

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Always on the Lookout Perfect Protection against Burglary

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

Roadstar Installation Instruction Manual

GPS Vehicle and personal location tracker. User manual

DS Wire Digital Thermometer and Thermostat

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

Modular I/O System Analog and Digital Interface Modules

Rack mounted telephone- and leased line modem for industrial applications

Talon and Talon SR User Manual

TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE

RS - SPM. Serial parallel translator module

WICE-SPI Hardware Operation Manual

Unidirectional Transmitter/ Receiver Units Introduction

GSM AUTO-DIALER With 10Amp Relay USER GUIDE

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

2014 GSM SHIELD COMPATIBLE WITH ARDUINO GSM SHIELD USING SIMCOMM (SIM900A)

HORNET Remote Control Systems

Installation manual. Generator Paralleling Controller GPC multi-line C

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL

Electronic Control Devices The European Product Catalogue 2007

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

MANUAL FOR RX700 LR and NR

MicroMag3 3-Axis Magnetic Sensor Module

The modular concept of the MPA-3 system is designed to enable easy accommodation to a huge variety of experimental requirements.

Ordering Part Numbers:

USB-QUAD08. Eight-channel Quadrature Encoder Input Device. Specifications

GSM AUTO DIALER. Remote Monitoring & Control using your mobile phone.

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

GSM Interfacing Board

UM0272 User manual. Central Unit for Alarm System (CUAS) Evaluation Board. Introduction

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)

RC2200DK Demonstration Kit User Manual

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

Multifunction devices

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

LMU Hardware and Installation Guide

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

GSM Gate Opener GSM Remote Switch RTU5015 User Manual

Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

MEITRACK T1 User Guide

FWT-8848 GSM (GATEWAY) USER S MANUAL

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

WIRELESS MAGNETIC CONTACT

Users Manual of GSM Home Alarm System with Photo-taken

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

GSM home alarm system s manual

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

RDF1. RF Receiver Decoder. Features. Applications. Description. Ordering Information. Part Number Description Packages available

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

INSTRUCTION. The smallest GPS watch locator in the country

DS1621 Digital Thermometer and Thermostat

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

Transcription:

GSM Controller BR160GM-Gate Gate opener version for Gate control. GSM module for SMS remote monitoring and control applications Alarm Notification Remote Control www.bieneelectronics.com

Features Internal quad-band GSM-modem 6 digital input ports 3 Open-Drain MOSFET output ports 1 Power Relay output Error notification using SMS messaging via cell phone Control via SMS Configuration from cell phone Introduction The BieneRemote160GM GSM controller is a communications device that connects used for wireless Alarm Monitoring and Control of remote equipments and systems. Multiple users can interrogate the BieneRemote160GM or be notified on configurable events. The built-in quad-band GM862-quad GSM module compatible with 850/900/1800/1900Mhz GSM networks. BieneRemote160GM-S - Standard version for digital signal monitoring. BieneRemote160GM-4A/2A - Analog version for digital and analog signal monitoring. BieneRemote160GM-SMT - Temperature version for digital signal and temperature monitoring. BieneRemote160GM-GATE - Gate opener version for Gate control.

SMS Function SMS controller send an event SMS messages to up to 4 cell phones. Any cell phone can be used to send SMS commands to BieneRemote160GM. Mobile users can contact and request information from a BieneRemote160GM GSM controller and up to 4 users can receive notification of events. With the BieneRemote160GM GSM controller you can use a mobile phone to: Monitor the status of equipment or systems Send control commands to remote equipment Receive notification of events Any BieneRemote160GM GSM controller can be used to send SMS commands to other BieneRemote GSM controller for remote control. Any BieneRemote160GM GSM controller can be programmed via SMS instruction. SMS based remote monitoring and control application Input Signal Monitoring The BieneRemote160GM has 6 voltage-free digital inputs that can be configured as: 0-1 or 1-0 event input each input can with jumper connect to pullup resistor (to +5V or +12V optional) To receive SMS message by event on inputs, you need entering SMS message on a module (or SIM card) programming.

Output Control The BieneRemote160GM has 3 open-drain Outputs and 1 Power Relay Output. These may be controlled with SMS messages from approved users. To set any output as you like, you need only to send an SMS message. Module to Module Control The BieneRemote160GM supports Module-to-Module management with SMS command. Users and Administrator The BieneRemote160SM supports up to 3 users. Each user can interrogate the device for the current I/O status. Users can be notified based on changes to each input. Security The BieneRemote160GM has a number of in-built security features. Caller ID security provide authentication for device interrogation and control. Alarm SMS messages can be sent to users when an input reaches an alarm state. The following setpoint configurations are available: Alarm when 0-1 or 1-0 event at digital input. Module Programming/Configuration The BieneRemote160GM can be configured (programming) remotely with SMS command. Configuration options include Alarm Message Content, Users and Administrators Phone Numbers and other.

Technical Specification BieneRemote160GM Hardware Specification GSM band support Internal GSM modem RF Transmit Power Command and data transmission SIM card reader SIM card type Antenna Connection Firmware Digital inputs Digital inputs type BR160GM-S BR160GM-4A/-2A BR160GM-SMT BR160GM-GATE GSM850/900/1800/1900 Telit GM862-QUAD Class 4 (2W) 900Mhz, Class 1 (1W) 1800Mhz, 1900Mhz SMS Yes Phase 2 GSM11.14 - SIM 3V 50Ω SMA (f) Connector Yes Voltage-free, transistor ("0": 0...+1V; "1": +1.5 +12V without external limited resistor); Optional: +12V/+5V pullup resistor for each input - Number of digital inputs 6 6 4 6 - Events digital inputs 6 6 4 6 - Digital inputs event 0-1 or 1-0 - Digital signal filter 25ms 9sec - Protection Yes Temperature sensor inputs Temperature sensor - - SMT160-30 - (Smartec) Number of temperature inputs - - 2 - Temperature input event - - min / norm / max - Temperature range - - -45 to +130 C - Events Temperature range - - -45 to +130 C Accuracy - - 1.2 C - Protection - - Yes - Analog inputs Number of analog inputs - 4 / 2 - - - Protection - yes - - - Analog input event - min / norm / max - - - ADC resolution - 10-bit - - Outputs Number of outputs 4 - MOSFET Open Drain 3 (50V max) outputs - Relay outputs 1 (NO/COM/NC), 28VDC/230AC/ 5A - Digital output control On-Off; Pulse (Standard and Gate version only) Gate Control Call Control Yes Number of user Up to 250 Wiring Wiring Connections Screw terminal blocks Power Supply Required Power supply External +12 VDC stabilized Power requirement 50mA typ, 350mA(rms) max, 2A max. peak during transmission Voltage regulator Internal voltage regulator Power protection Reverse-polarity and overvoltage protection

Environmental Conditions Normal operating temperature.range Extreme operational temperature range Storage temperature range Humidity Physical parameter Board dimension Enclosure dimension Box Weight -10 +55 C -20 +70 C (these temperature can affect the sensitivity and performance of the module) -40 to +80 C 0-95% non-condensing 103 x 86.5 mm 106 x 100 x 58 mm DIN-rail mounting BieneRemote160GM Firmware Specification BR160GM-S BR160GM-4A/-2A BR160GM-SMT BR160GM-GATE Number of controlled outputs 4 Number of digital event inputs 6 6 4 5 Number of readable digital 6 6 4 5 inputs Number of analog event inputs Number of readable analog data - 4 / 2 - - - 4 / 2 - - Authorization cell phone 3 2 / 3 3 3 numbers Events cell phone numbers 3 2 / 3 3 2 SMS events format Text message SMS digital data format Binary Binary Binary HEX SMS message format for analog data SMS message format for temperature data In % from Reference level 00-99 º C min level, max level -45º C - +130º C

BieneRemote160GM-Gate -Gate Communication Door open, with Access control via GSM 900/1800/1900 or 850/900/1800/1900Mhz Dialing Authorized or not authorized Maximum number of users 250 Identification methode User numbers programming, with Internal GSM modem SIM card reader SIM card type Firmware Users phone number SMS GM862-QUAD Yes Phase 2 GSM11.14 - SIM 3V Yes Inputs Number of inputs 5 Events Inputs 5 Outputs Number of outputs 4 - Relay outputs 1 (NO, NC, COM; 28VDC/230VAC/5A) - MOSFET transistor outputs 3 *) (50V max) Output signal duration, sec (output 2 and 3) 01-99 sec (pulse mode) 00 (ON/OFF with dialing - latch mode) Power Supply Required Power supply Power requirement Voltage regulator Power protection External +12 VDC stabilized 50mA typ 350mA (rms) max, 2A peak max. during transmission (rms) Internal voltage regulator Reverse-polarity protection Environmental Conditions Normal operational temperature range Extreme operational temperature range (these temperature can affect the sensitivity and performance of the module) Board dimension -10 +55 C -20 +70 C 103 x 86.5 mm *) Note: One MOSFET output can used as BUZZER output.

Hardware The BieneRemote160GM module consists of the microprocessor, voltage regulator, inputs driver, MOSFET output driver, relay, built-in GSM module, GSM antenna connector and screw terminals for external power supply and for input and output signal connection.

Power Supply The BieneRemote160GM operates from a 12VDC power source. It draws less then 70mA standby, less then 350mA rms and 2A peak max. 12VDC/1.3A...2A switching stabilized power supply is recommended. Power supply input has reverse polarity and overvoltage protection. SIM Card Small SIM-card with 3V technology Preparation of SIM card 1. Delete any SMS messages from SIM. 2. Disable PIN code request so it will not prompt for a PIN code on turning on. 3. Write 3 authorized numbers to Phone Book (position 1,2,3) You can to position 1 write number 99 or +99 for disable authorization numbers Note: The BieneRemote160GM can only be used with small SIM-cards with 3V technology. For SIM card preparation you can use cell phone or external GSM modem. SIM card change if power turn off. LED indicators Module status indication - RED LED (LED1) GSM Modem SIM300 status indication - GREEN LED (LED2) Module LED indication (Red LED) LED status Permanently off Short blinking after power on and after 1 min periodic blinking Short blinking (period 5-6 sec) Permanently on Modem status Device off SIM card read process Module in work Module work with modem GSM Modem LED indication (Green LED) LED status Permanently off Fast blinking (period 1s, ton 0,5s) Slow blinking (period 3s, ton 0,3s) Permanently on Modem status Device off Net search / Not registered / Turning off Registered full service A call is active

Connectors and Jumpers Power supply (X2 - screw terminal block). Controlled equipment inputs and outputs (X2, X3, X4 - screw terminal block) SMA female connector (X5) for GSM antenna connection. Power Supply Connection +12VDC stabilized Power Supply must be connected with screw terminal block. We recommend use stabilized 1,3...2A 12VDC power supply. Power supply input has negative voltage and over voltage protection. Internal +12VDC connection and Power Supply connection schematic. Antenna connection GSM antenna must be connected to SMA connector X5. Use only the 50Om antenna of the necessary frequency range. Base version complected with direct mount GSM antenna. Note: It is very important that the antenna is installed on a location where the GSM-network coverage is sufficient. Please also check carefully that antennas are not installed nearby technical devices, cables etc which could influence the GSM-radiation.

Inputs and Outputs connection Digital inputs and outputs must be connected with screw terminal blocks X2-X4. Note: See also "Inputs and Outputs schematic". Connectors For Power supply, Inputs and Outputs connection used screw terminal blocks. +12V - +12VDC Power Supply input / +12VDC output GND - GND INP1...INP6 - Digital Inputs 1-6 AN1...AN4 - Analog Inputs 1-4 (not support in this version) OUT1,OUT2,OUT4 - Output 1, Output 2, Output 4 NO/COM/NC - Relay Output 3 +5V - +5V output (50mA max)

Gate Automatic Connection For gate automatic control used relay output: Output 2 - alternative output for gate control. Output 1 and Output 4 - for optional use. Additional Interface Standard 2x3 pin ISP interface connector X1. Used only for in-system microcontroller programming. Pin Pin 1 MISO 2 VCC 3 SCK/ 4 MOSI 5 Reset/ 6 GND

Jumpers Jumper J2 Connection pull-up resistor to digital inputs. 2k2 resistor for each inputs is used. All resistor pulled up to +5V (+12V optional). Note: Use this jumper only for Open Collector or Relay Output.

Inputs / Outputs Schematic Inputs Digital Transistor Inputs Connector: Screw terminal block Inversion: Yes Protection: Yes Max input voltage: +12V without external limited resistor. Free Input: logic "0" Logic "0": 0V +1V Logic "1": +1.5V +12V J2 jumper for pull-up resistor connections to +12V (+5V optional) 0-10V / 0-5V Analog Inputs Connector: Screw terminal block Input type: CMOS Input Voltage: 0 to +10V Protection: Yes Input resistance: 100 KOm. ADC resolution: 10-bit 249 Om resistor optional for 0-20/4-20mA applications

Outputs MOSFET Open Drain Outputs Connector: Screw terminal block MOSFET transistor: Si9945 or IRF7103 Max. Voltage: 50V Relay Output Connector: Screw terminal block Outputs: NO/COM/NC Relay: SPDT power relay Breaking capacity: 5 A 230VAC / 28VDC Min load: 0.1 A, 5VDC

Connection Example Connection example to Input Driver (Input 1-5) 1-0 and 0-1 event notification You can use J2 pin header for in-board pull-up resistor connection. Relay connection example to Output Driver (Output 1, 2 and 5) Electromechanical relay connection. Solid-state-relay (SSR) connection.

Module programming For module programming: SIM card preparation Programming with send control SMS (see paragraph 'SMS Control Command List') SIM card preparation Delete any SMS messages from SIM. Write alarm SMS message to SIM (if you use alarm function) Disable PIN code request so it will not prompt for a PIN code on turning on. Write 2 authorized numbers to Phone Book (position 1,2) Write gate open user cell phone numbers to Phone Book (position from 3); you can added and deleted numbers with SMS command. Note: The module can only be used with small SIM-cards with 3V technology. For SIM card preparation you can use cell phone or external GSM modem. Set phone numbers from which management (module settings, add/delete SMS phone book) is authorized Phone Book 1 A1 <Phone number1> 1) 2 A2 <Phone number2> 1) 1): full phone number with country code (see Note below) Example: enable 2 phone numbers for module management Phone Book 1 A1 +3715881456 2 A2 +3716149759 Example: enable all phone numbers (disable authorization numbers; all cell phone enabled for gate open) Phone Book 1 A1 99 2 A2 <Phone number2> NOTE: For difference mobile operators can be difference number format in CLIP. For example for Latvia BITE and LMT +37122832798 TELE2 22832798 (without country code) Also for difference country can be difference number format in CLIP for UK: At position 001 and 002 you should write number with country code (+441234567890) At position 003... 250 you should write number without country code (01234567890)

Phone Book in SIM and EEPROM Phone Book stored in SIM and in EEPROM BR160GM-GATE module. After restart module Phone Book from SIM card copy to EEPROM. After SMS command ADDNUM number added to Phone Book in EEPROM and in SIM card. After SMS command DELNUM number deleted from Phone Book in EEPROM and from SIM. You can write numbers to SIM Phone Book directly Phone Book 001 A1 <Phone number 1> 002 A2 <Phone number 2> 003 A3 <Phone number 3> 004 249 A249 <Phone number 2490> 250 A250 <Phone number 250> Number at location 001 and 002 Number at location 001 and 250 - privileg.number: from this cell phone you can send SMS command for setting and control. - numbers, enabled for gate open process. If at location 001 empty or short number, for example 001 or 99, then all cell phone enabled for gate open process. You can write numbers to SIM Phone Book. with SMS command ADDNUM or deleted number from SIM Phone Book with SMS command DELNUM You can add new number to phone book ADDNUM SMS command. - If phone book full, you receive answer SMS 'SIM Phone Book Full' - If phone book not full, new number entered to first empty position in phone book you receive SMS 'NR 17 +37122842915 added' (you receive also position in phone book) - If number exist in phone book, you receive SMS 'NR 42 +37122842915 exist' (number exist in phone book at position 042) - If number not exist in phone book, you receive SMS 'NR 250 +37122842915 added' (number added at position 250) You can delete new number from phone book DELNUM SMS command. - If number not exist in phone book, you receive answer SMS 'NR +37122842915 not exist' - If number exist in phone book, you receive answer SMS 'NR 250 +37122842915 deleted' You can read number from phone book GETNUM SMS command. New SMS command Maxnn1 Maxnn9 Maxnn1 30 numbers maximum; Maxnn2 60 numbers maximum (default setting) Maxnn8 240 numbers maximum; Maxnn9 250 numbers maximum

Example: ADDNUM +37167265259 Phone Book 001 A1 <Phone number 1> 002 A2 <Phone number 2> 003 A3 <Phone number 3> 004 +37167265259 +37167265259 249 +37129106159 +37129106159 250 A250 <Phone number 250> DELNUM +37129106159 Phone Book 001 A1 <Phone number 1> 002 A2 <Phone number 2> 003 A3 <Phone number 3> 004 +37122842915 +37122842915 249 249 249 250 A250 <Phone number 250> Add number to SIM phone book ADDNUM +37122842915 or Addnum +37122842915 - add number +3716149759 to SIM phone book - add number +3716149759 to SIM phone book Answer SMS: NR 12 +37122842915 added - if number added to SIM phone book at location 012 NR 12 +37122842915 exist - if number exist in SIM phone book at location 012 where: NR 12-012 - location in SIM phone book NOTE: For difference mobile operators can be difference number format in CLIP. For example for Latvia BITE and LMT +37122832798 TELE2 22832798 (without country code) Also for difference country can be difference number format in CLIP for UK: At position 001 and 002 you should write number with country code (+441234567890) At position 003... 250 you should write number without country code (01234567890)

Delete number from SIM phone book DELNUM +37122842915 or Delnum +37122842915 - delete number +3716149759 from SIM phone book - delete number +3716149759 from SIM phone book Answer SMS: NR 11 +37122842915 deleted - if number deleted from SIM phone book (from position 011) NR +37122842915 not exist - if number not exist in SIM phone book where: NR 11-011 - location in SIM phone book Read number from phone book GETNUM 051 - read number from SIM phone book with location 051 Answer SMS: NR 051: +37122842915 Note: - If in your cell phone in phone book phone number exist with name, for example, BIENE, your cell phone display following answer SMS: NR 11 BIENE deleted NR 001: BIENE NR 12 BIENE added Set output impulse duration (accuracy +/- 20%) SETDD 12 SETDD 90 SETDD 00 SETDD 02 SETDD 00 - set duration = 12 sec - set duration = 90 sec - disable output impulse - latch mode - set pulse duration = 2 sec - disable pulse latch mode

Remote control You can with dialing (without connection) open your gate. Output 3 and Output 2 for gate control. We can turn on and turn off module outputs with SMS command: SETOU and RSTOU. SETOU1 RSTOU1 - set output 1 to '0' - active state. - reset output 1 to '1' - passive state. Answer SMS: INP=3F OUT=00 Pulse (sec) 5 where: INP=3F OUT=00 Pulse (sec) - input state in HEX (inverse to inputs on terminal block) - output state (output 4..1) in HEX - output impulse duration (in sec) If Pulse = 00 (see SMS command Setdd), then latch mode. First dial - turn on, second dial - turn off

SMS Control Command List Control Command List Command Function Return Message Description 1) Read Status Getst Get Status INP=3F OUT=00 Pulse (sec) 5 Input and output state, pulse duration (output 3) Outputs control Setou1 Set Output 1 - Set Output 1 Setou2 Set Output 2 - Set Output 2 Setou3 Set Output 3 - Set Output 3 - relay ON Rstou1 Reset Output 1 - Reset Output 1 Rstou2 Reset Output 2 - Reset Output 2 Rstou3 Reset Output 3 - Reset Output 3 - relay OFF Setdd NN Addnum Delnum Set output impulse duration Add new number Delete number Settings INP=3F OUT=00 Pulse (sec) 5 Phone Book Settings NR 12 +37122842915 added or NR 12 +37122842915 exist NR 12 +37122842915 deleted or NR +37122842915 not exist Getnum Read number NR 167: +37122842915 Set output impulse duration, NN = 00..99 sec.; default 02 if NN=00, then latch mode ADDNUM +37122842915 DELNUM +37122842915 GETNUM 001 001 - location in SIM phone book Rstart Restart Restart (module work after 2 min) MaxnnN Set Max numbers note: This SMS command support only new version software INP=3F OUT=00 Pulse (sec) 5 MaxNN=60 N from 1 to 9 N=1 30 numbers N=2 60 numbers (default)... N=8 240 Numbers N=9 250 numbers Note: 1): Not case sensitive. You can use GETNUM, Getnum, SMS command module executed after 60 sec maximum. If you change first number in SIM phone book, required restart module for new installation.

SMS Reporting Message (Alarm SMS in SIM) SMS Message Number in SIM SMS Message Cell Phone Number Input NR 1 Event 1 <Phone number> 1 2 Event 2 <Phone number> 2 3 Event 3 <Phone number> 3 4 Event 4 <Phone number> 4 5 Event 5 <Phone number> 5 Example SMS Message Cell Phone Input Nr Text of Messages Number Number Connected to 1 Door open <Phone number> 1 Door sensor 2 Smoke detection <Phone number> 2 Smoke detectors 3 <Phone number> 3 4 <Phone number> 4 Not connected input state Input state Status data INP= Input state with connected pull-up resistor (J2) Input 1 0 0 1 Input 2 0 0 1 Input 3 0 0 1 Input 4 0 0 1 Input 5 0 0 1 Input 6 0 0 1 Active event on input Input state Input 1 1-0 Input 2 1-0 Input 3 1-0 Input 4 1-0 Input 5 1-0

Output state Output state Output state Status data OUT= Output 1 Open Drain 1 1 Output 2 Open Drain 1 1 Output 3 Relay NO 1 1 Output 4 Open Drain 1 1 Phone numbers from which management is authorized (optional) Delete all entry in active phone book and write 3 phone numbers of mobile phone. Phone Book 1 A1 <Phone number1> 2 A2 <Phone number2> 3 A3 <Phone number3> Note 1: full phone number with country code Example - enable 2 phone numbers for module management (A1 and A2); for gate open enable only number in SIM phone book (max. 250 numbers) Phone Book 1 A1 37122842913 2 A2 37122842914 3 A3 37122842915 Example - enable all numbers (disable authorization numbers); all number enabled for gate open. Phone Book 1 A1 99 2 A2 <Phone number2>

Support Biene Electronics SIA Riga, Latvia www.bieneelectronics.com E-mail: support@bieneelectronics.com Please send your comments, suggestions and bug reports to support@bieneelectronics.com