Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT-1900349 Issued April 17, 2015



Similar documents
FX-PCA Advanced Application Programmable Controller Catalog Page

Network Control Engine Product Bulletin

Metasys System Field Equipment Controllers and Related Products Product Bulletin

FX07 Field Controller

FX07 Field Controller

NCE25 Installation Instructions Part No , Rev. L Software Release 7.0 Issued December 5, 2014

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

Electronic Control Devices The European Product Catalogue 2007

Portable BACnet /IP to MS/TP Router

Electronic Control Devices The European Product Catalogue 2007

FX16 Master Controller

English plain text messages with constant backlight that brightens during user interaction. On/Off, Floating, or Proportional 0 to 10 VDC Control

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

MS/TP Communications Bus Technical Bulletin Code No. LIT Software Release 7.0 Issued July 2, 2015

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

Duct Humidity Transmitter

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Digital input modules

BACnet. bcx1 Controller/ Router Series

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Model: DC-A2IO Advanced HVAC Controller

TAC I/NETTM MR-AHU-HP. Application Specific Controller

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Foxboro Evo Process Automation System

Protects against unwanted thermostat controller tampering. Increases occupancy comfort by providing dehumidification.

ComfortPoint Open Building Management System. For consultants and specifiers. The Simply Smart way to optimize building control and performance

Contents. Document information

Quick Connect. quick - simple - efficient.

System 350 A350E Electronic Cooling Control

CompactLogix Power Supplies Specifications

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Unidirectional Transmitter/ Receiver Units Introduction

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

HMI display Installation Guide

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Waveguide Access Point WGA631. Product Guide

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

NX safety stand-alone

TX OPEN RS232/485 module

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

RM4TG20 three-phase network control relay RM4-T - range V

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

S-series Mass Connection Solutions

AIS750 Series Alarm Annunciator

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

40.3. Control Relays and Timers

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

LN Application Specific, Remote I/O, and Free Programmable Controllers

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

3466 Building Energy Management Training Systems

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Hand-held thermometer Model CTH7000

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

A99B Series Temperature Sensors

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

SMART Board 685ix interactive whiteboard system Model 685ix

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

IO-RM3 3-Stage Relay Module

EXTERNAL DIMENSIONS AND PARTS

3DLevelScanner II TECHNICAL DATA SHEET

Installation Instructions. Wireless Adapter/Repeater. Introduction Rev C

Telephone- and leased line modem for industrial applications TD-36

80 Series - Modular timers 16 A. Features

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Rosemount 333 HART Tri-Loop

Climate Ready Control Systems Technical Specifications

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

T7079A,B Solid State Remote Temperature Controllers

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Voltage Regulator SPAU 341 C. Product Guide

How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Modular I/O System Analog and Digital Interface Modules

Tracer Summit Web Server

Temperature & Humidity SMS Alert Controller

IntesisBox KNX - LON

Easy Installation All five standard monitors fit into shallow mounting areas, requiring about 3" of depth. The XT1502, SXT1811, and SXT2011 models hav

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

MINI MCR-SL-R-UI(-SP)

Models HP HDMI to VGA Adapter HP EliteFolio Ethernet & VGA Adapter New! HP HDMI to DVI Adapter New! HP DisplayPort to HDMI 1.4 Adapter New!

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Transcription:

Code No. LIT-190039 Issued April 17, 015 Refer to the QuickLIT website for the most up-to-date version of this document. The Input/Output Module () Series Controllers are BACnet Application Specific Controllers (B-ASCs) with integral RS-85 Master-Slave/Token-Passing (MS/TP) communications. controllers integrate into the web-based Metasys system. Note: At CCT Release 10.1, VMAs, FECs, and FACs can communicate by using either the BACnet or the N field bus networking protocol. The operation of the Input/Output Module is not affected by the selection of the BACnet or the N protocol in the host controller. s can serve in one of two capacities, depending on where they are installed in the Metasys system. When installed on the Sensor/Actuator (SA) Bus of an Field Equipment Controller (FEC), Advanced Application Field Equipment Controller (FAC), or VMA controller, the s expand the point count of these controllers. When installed on the Field Controller (FC) Bus, s can be used as I/O point multiplexors to support monitoring and control from an Network Automation Engine (NAE) or Network Control Engine (NCE). The point multiplexor can also be useful for sharing points between other field controllers on the FC Bus using peer-to-peer connectivity. A full range of FEC models combined with the models can be applied to a wide variety of building applications ranging from simple fan coil or heat pump control to advanced central plant management. Important: Important: You cannot purchase a similar third-party device and install it in a UL/ULC Listed smoke control system. Doing so voids the UL/ULC Smoke Control Listing. Third-party devices must be provided and labeled by the factory as described in the UL/ULC Smoke Control Listing. Only those Johnson Controls products identified for use in smoke control applications have been tested and listed by UL for use in a Metasys System UL 86 9th Edition UUKL/ORD-C100-13 UUKLC Smoke Control System. Installation of a product that is not UL/ULC Listed and labeled for this application prevents the entire system from being UL/ULC Listed for smoke control. Bluetooth Wireless Commissioning Interface - Provides an easy-to-use connection to the configuration and commissioning tool. Auto Tuned Control Loops - Reduce commissioning time, eliminate change-of-season re-commissioning, and reduce wear and tear on mechanical devices. Universal Inputs, Configurable Outputs, and Point Expansion Modules - Allow multiple signal options to provide input/output flexibility. Optional Local User Interface Display - Allows convenient monitoring and adjusting capabilities at the local device. BACnet Testing Laboratories (BTL) Listing - Ensures interoperability with other BTL-listed devices. BTL is a third-party agency which validates that BAS vendor products meet the BACnet industry-standard protocol. 3-bit microprocessor ensures optimum performance and meets industry specifications. BACnet Automatic Discovery support enables easy controller integration into Metasys BAS. Integral end-of-line (EOL) switch enables field controller as a terminating device on the communications bus. Pluggable communications bus and supply power terminal blocks expedite installation and troubleshooting. Wireless capabilities via a ZFR1800 Series Wireless Field Bus System enable wireless mesh connectivity to supervisory controllers, facilitating easy initial location and relocation. Ability to reside on the FC Bus or SA Bus provides application flexibility. If the product fails to operate within its specifications, replace the product. For a replacement product, contact the nearest Johnson Controls representative. Figure 1: 711 Refer to the Metasys System Field Equipment Controllers and Related Products Product Bulletin (LIT-10110) for product application details. Features Standard BACnet Protocol - Provides interoperability with other Building Automation System (BAS) products that use the widely accepted BACnet standard. Standard Hardware and Software Platform - Uses a common hardware design throughout the family line to support standardized wiring practices and installation workflows. Also uses a common software design to support use of a single tool for control applications, commissioning, and troubleshooting to minimize technical training. 1

Table 1: Series Point Type Counts Per Model Point Types Signals Accepted 1711 711 71 3711 371 3731 711 Universal Input (UI) Analog Input, Voltage Mode, 0 10VDC 8 6 Analog Input, Current Mode, 0mA Analog Input, Resistive Mode, 0 kohm, RTD (1k NI [Johnson Controls], 1k PT, A99B SI), NTC (10k Type L,.5k Type ) Binary Input, Dry Contact Maintained Mode Binary Input (BI) Dry Contact Maintained Mode 16 8 Pulse Counter/Accumulator Mode (High Speed), 100 Hz Analog Output (AO) Analog Output, Voltage Mode, 0 10VDC Analog Output, Current Mode, 0mA Binary Output (BO) 1 VAC Triac 8 3 Universal Output (UO) Analog Output, Voltage Mode, 0 10VDC Binary Output Mode, VAC/DC FET Analog Output, Current Mode, 0mA Configurable Output (CO) Analog Output, Voltage Mode, 0 10VDC Binary Output Mode, VAC Triac Relay Output (RO) (-0 models only) 10/0 VAC Relay Output (RO) (-1 models only) VAC, SELV Relay Output (RO) (- models only) 0 VAC 1 The BOs on the 3731-0A model require an external low-voltage power source. Table : Series Ordering Information Product Code Number MS-1711-0 MS-711-0 MS-711-3 MS-71-0 MS-3711-0 MS-3711-3 MS-371-0 MS-3731-0 MS-3731-0A 1 MS-711-0 Description -Point with BI, FC Bus and SA Bus Support 6-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for 10/0 VAC. 6-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for 0 VAC. 10-Point with 8 UI, AO, FC Bus, and SA Bus Support 1-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for 10/0 VAC. 1-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for 0 VAC 16-Point with 16 BI, FC Bus, and SA Bus Support 16-Point with 8 BI, 8 BO, FC Bus, and SA Bus Support 16-Point with 8 BI, 8 BO, FC Bus, and SA Bus Support Note: Binary Outputs (BOs) on MS-3731-0A controllers do not supply power for the outputs; the BOs require external low-voltage (<30 VAC) power sources. 17-Point with 6 UI, BI, 3 BO, AO, CO, FC and SA Bus Support 1 This model is currently available only in Asia. Contact your local Johnson Controls representative for more information. UL Listed 3 CE Marked

Table 3: Series for Smoke Control Ordering Information Product Code Number 1, MS-1710-0U MS-1711-0U MS-710-0U MS-711-0U MS-3710-0U MS-3711-0U MS-IOU710-0U MS-711-0U Description -Point with BI; VAC; FC Bus and SA Bus Support -Point with BI; VAC; FC Bus and SA Bus Support 6-Point with UI, UO, BO; VAC; FC Bus and SA Bus Support 6-Point with UI, UO, BO; VAC; FC Bus and SA Bus Support 1-Point with UI, UO, BO; VAC; FC Bus and SA Bus Support 1-Point with UI, UO, BO; VAC; FC Bus and SA Bus Support 17-Point with 6 UI, BI, 3 BO, AO, CO; VAC; FC Bus and SA Bus Support with Mounting Base 17-Point with 6 UI, BI, 3 BO, AO, CO; VAC; FC Bus and SA Bus Support with Mounting Base 1 These devices are UL/ULC 86 Listed, File S977, 9th Edition UUKL/ORD-C100-13 UUKLC Smoke Control System. All field controllers in a smoke control system must be mounted in Johnson Controls custom or standard UL 86 panels or in panels that are ordered from Johnson Controls. If these field controllers are used with panels that are not supplied by Johnson Controls, they are not compliant with the UL 86 9th Edition UUKL/ORD-C100-13 UUKLC Smoke Control System listing. 3

Accessories Table : Accessories Product Code Number MS-BTCVT-1 TL-BRTRP-0 MS-ZFR1811-1 MS-BTCVTCBL-700 Y6T15-0 Y65A13-0 Y65T-0 Y65T31-0 AP-TBKSA-0 AP-TBKFC-0 AP-TBK3PW-0 ZFR-USBHA-0 Description Wireless Commissioning Converter with Bluetooth Technology Portable BACnet IP to MS/TP Router Wireless Field Bus Router, 10 mw Transmission Power. Functions with Metasys BACnet FECs, VMA16s, and WRZ Series Wireless Mesh Room Sensors Cable Replacement Set for the MS-BTCVT-1 or the NS-ATV7003-0; Includes One 5 ft (1.5 m) Retractable Cable Transformer, 10/08/0 VAC Primary to VAC Secondary, 9 VA, Foot Mount, 30 in. Primary Leads and 30 in. Secondary Leads, Class Transformer, 10 VAC Primary to VAC Secondary, 0 VA, Foot Mount (Y65AS), 8 in. Primary Leads and 30 in. Secondary Leads, Class Transformer, 10/08/0 VAC Primary to VAC Secondary, 0 VA, Hub Mount (Y65SP+), 8 in. Primary Leads and Secondary Screw Terminals, Class Transformer, 10/08/0 VAC Primary to VAC Secondary, 0 VA, Foot Mount (Y65AR+), 8 in. Primary Leads and Secondary Screw Terminals, Class Replacement MS/TP SA Bus Terminal, -Position Connector, Brown, Bulk Pack Replacement MS/TP FC Bus Terminal, -Position Connector, Blue, Bulk Pack Replacement Power Terminal, 3-Position Connector, Gray, Bulk Pack ZFR USB Dongle driver provides a wireless connection through CCT to allow wireless commissioning of the wirelessly enabled FEC, Advanced Application Field Equipment Controller (FAC),, and VMA16 controllers. Also allows use of the ZFR Checkout Tool (ZCT) in CCT. Series Technical Specifications Table 5: Series Product Code Numbers MS-1711-0: -Point with BI, FC Bus and SA Bus Support MS-711-0: 6-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for 10/0 VAC MS-711-1: 6-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for VAC MS-711-: 6-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for 0 VAC. MS-71-0: 10-Point with 8 UI, AO, FC Bus, and SA Bus Support MS-3711-0: 1-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for 10/0 VAC MS-3711-1: 1-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for VAC MS-3711-: 1-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for 0 VAC MS-371-0: 16-Point with 16 BI, FC Bus, and SA Bus Support MS-3731-0: 16-Point with 8 BI, 8 BO, FC Bus, and SA Bus Support MS-3731-0A 1 : 16-Point with 8 BI, 8 BO, FC Bus, and SA Bus Support MS-711-0: 17-Point with 6 UI, BI, 3 BO, AO, CO, FC and SA Bus Support Smoke Control Models: MS-1710-0U: -Point with BI, FC Bus and SA Bus Support MS-1711-0U: -Point with BI, FC Bus and SA Bus Support MS-710-0U: 6-Point with UI, UO, BO, FC Bus, and SA Bus Support MS-711-0U: 6-Point with UI, UO, BO, FC Bus, and SA Bus Support MS-3710-0U: 1-Point with UI, UO, BO, FC Bus, and SA Bus Support MS-3711-0U: 1-Point with UI, UO, BO, FC Bus, and SA Bus Support MS-IOU710-0U: 17-Point with 6 UI, BI, 3 BO, AO, CO, FC Bus and SA Bus Support with Mounting MS-711-0U: 17-Point with 6 UI, BI, 3 BO, AO, CO, FC Bus and SA Bus Support with Mounting Supply Voltage VAC (nominal, 0 VAC minimum/30 VAC maximum), 50/60 Hz, Power Supply Class (North America), Safety Extra-Low Voltage (SELV) Europe

Table 5: Series Power Consumption 1 VA maximum Note: VA ratings do not include any power supplied to the peripheral devices connected to Binary Outputs (BOs) or Configurable Outputs (COs), which can consume up to 1 VA for each BO or CO, for a possible total consumption of an additional 8 VA (maximum), depending on the model. Ambient Conditions Operating: 0 to 50 C (3 to 1 F); 10 to 90% RH noncondensing Storage: -0 to 80 C (-0 to 176 F); 5 to 95% RH noncondensing Addressing DIP switch set; valid field controller device addresses 17 (Device addresses 0 3 and 18 55 are reserved and not valid addresses). Communications Bus BACnet MS/TP, RS-85 3-wire FC Bus between the supervisory controller and field devices -wire SA Bus between field controller, network sensors, and other sensor/actuator devices. Includes a lead source 15 VDC supply power (from field controller) to bus devices. Processor Memory H8SX/166xR Renesas 3-bit microcontroller 51 KB Flash Memory and 18 KB Random Access Memory (RAM) 5

Table 5: Series Input and Output Capabilities 1711: - Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/ Accumulator Mode 711: - Universal Inputs: Defined as 0 10 VDC, 0 ma, 0 600k ohm, or Binary Dry Contact - Universal Outputs: Analog Output: Voltage Mode, 0-10 VDC; Binary Output Mode: VAC/DC FET; Analog Output: Current Mode, -0 ma - Relay Outputs: (Single-Pole, Double-Throw); UL 916 (-0 model only): 1/ hp 10 VAC, 1/ hp 0 VAC; 360 VA Pilot Duty at 10/0 VAC (B300); 3 A Non-inductive -0 VAC; EN 60730 (-1 model only): 6 () A N.O. or N.C. only, VAC, SELV EN 60730 (- model only): 6 () A N.O. or N.C. only, 0 VAC 71: 8 - Universal Inputs: Defined as 0 10 VDC, 0 ma, 0 600k ohm, or Binary Dry Contact - Analog Outputs: Defined as 0 10 VDC or 0 ma 3711: - Universal Inputs: Defined as 0 10 VDC, 0 ma, 0 600k ohm, or Binary Dry Contact - Universal Outputs: Analog Output: Voltage Mode, 0-10 VDC; Binary Output Mode: VAC/DC FET; Analog Output: Current Mode, -0 ma - Relay Outputs: (Single-Pole, Double-Throw); UL 916 (-0 model only): 1/ hp 10 VAC, 1/ hp 0 VAC; 360 VA Pilot Duty at 10/0 VAC (B300); 3 A Non-inductive -0 VAC; EN 60730 (-1 model only): 6 () A N.O. or N.C. only, VAC, SELV EN 60730 (- model only): 6 () A N.O. or N.C. only, 0 VAC 371: 16 - Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode 3731: 8 - Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode 8 - Binary Outputs: Defined as VAC Triac (Require external low-voltage power source.) Note: Binary Outputs (BOs) on MS-3731-0A controllers do not supply power for the outputs; the BOs require external low-voltage (< 30 VAC) power sources. 711: 6 - Universal Inputs: Defined as 0 10 VDC, 0 ma, 0 600k ohm, or Binary Dry Contact - Binary Inputs: Defined as Dry Contact Maintained or Pulse/Counter Accumulator Mode 3 - Binary Outputs: Defined as VAC Triac (selectable internal or external source power) - Configurable Outputs: Defined as 0 10 VDC or VAC Triac BO - Analog Outputs: Defined as 0 10 VDC or 0 ma Analog Input/Analog Output Resolution and Accuracy Terminations Analog Input: 16-bit resolution Analog Output: 16-bit resolution and ±00 mv in 0 10 VDC applications Input/Output: Fixed Screw Terminal Blocks SA/FC Bus and Supply Power: -wire and 3-wire Pluggable Screw Terminal Blocks SA/FC Bus Port: RJ-1 6-Pin Modular Jacks Mounting Housing Horizontal on single 35 mm DIN rail mount (preferred), or screw mount on flat surface with three integral mounting clips on controller Enclosure material: ABS and polycarbonate UL9 5VB; self-extinguishing, Plenum-rated protection class: IP0 (IEC59) 6

Table 5: Series Dimensions (Height x Width x Depth) 17 and 7 Family Models: 150 x 10 x 53 mm (5-7/8 x -3/ x -1/8 in.) including terminals and mounting clips 71, 371, and 3731 Models: 150 x 16 x 53 mm (5-7/8 x 6-7/16 x -1/8 in.) including terminals and mounting clips 37 and 7 Family Models: 150 x 190 x 53 mm (5-7/8 x 7-1/ x -1/8 in.) including terminals and mounting clips Note: Mounting space for all field controllers requires an additional 50 mm ( in.) space on top, bottom, and front face of controller for easy cover removal, ventilation, and wire terminations. Weight Compliance 0.5 kg (1.1 lb) maximum United States: UL Listed, File E10701, CCN PAZX, UL 916, Energy Management Equipment; UL/ULC 86 Listed, File S977, 9th Edition UUKL/ORD-C100-13 UUKLC Smoke Control System (models with U product code suffix only); FCC Compliant to CFR7, Part 15, Subpart B, Class A Note: Except 711- and 3711- Canada: UL Listed, File E10701, CCN PAZX7, CAN/CSA C. No. 05, Signal Equipment; UL/ULC 86 Listed, File S977, 9th Edition UUKL/ORD-C100-13 UUKLC Smoke Control System (models with U product code suffix only); UL/ULC 86 Listed, File S977, 9th Edition UUKL/ORD-C100-13 UUKLC Smoke Control System (models with U product code suffix only); Industry Canada Compliant, ICES-003 Note: Except 711- and 3711- Europe: CE Mark Johnson Controls, Inc. declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 00/108/EC. Declared as Independently Mounted, Intended for Panel Mounting, Operating Control Type 1.B, kv rated impulse voltage, 100.7 C ball pressure test. Note: Except 711-0 and 3711-0 Australia and New Zealand: C-Tick Mark, Australia/NZ Emissions Compliant Note: Except 711-0 and 3711-0 BACnet International: BACnet Testing Laboratories (BTL) Protocol Revision Listed BACnet Application Specific Controller (B-ASC) 1 This model is currently available only in Asia. Contact your local Johnson Controls representative for more information. For more information, refer to the MS/TP Communications Bus Technical Bulletin (LIT-101103). The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Building Efficiency 507 E. Michigan Street, Milwaukee, WI 530 Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 015 Johnson Controls, Inc. Published in U.S.A. www.johnsoncontrols.com 7