1 FX-PCA Advanced Application Programmable Controller Catalog Page Code No. LIT Issued December 5, 01 Refer to the QuickLIT website for the most up-to-date version of this document. The FX-PCA Series controllers offer more advanced features than the other FX-PC controllers. FX-PCA controllers feature an integral real-time clock and support time-based control logic, such as scheduling, alarming, and trending. As a result, FX-PCAs are well suited for standalone applications that do not have a networked supervisory controller or for networked application where FX-PCAs can continue time-based control and monitoring when offline from the supervisory controller. The FX-PCAs include RS-85 field bus networking with selectable N or BACnet MS/TP protocols. FX-PCAs also support wireless field bus networking and sensing by adding FX-ZFR accessories. A range of FX-PCA models are available with various onboard inputs and outputs, including a -point FX-PCA311. Also, FX-PCA controllers can be combined with FX-PCX Expansion I/O Modules to gain more I/O interfaces if needed. FX-PCAs and their advanced features make them well suited for monitoring and controlling a wide range of equipment including terminal units (such as fan coils and unit ventilators), as well as more complex equipment (such as air handlers and central plants). Persistence on the FX-PCA311 model has been significantly upgraded and now includes a fast persistence feature that allows you to hold data values at a configurable value, up to once per second. Persistence refers to how often samples of data are stored locally. This ensures that in the event of a problem, such as a loss of power, data can be retrieved up to the rate that the data is persisted, minimizing the potential loss of data. When power is restored, previously persisted data, up to the rate of persistence, remains available and accessible. For example, if persistence is configured for once per second, you only risk losing one second of data. Persisting data may be essential for situations that require greater data accuracy. This may include certain methods of utility data collection and billing. FX-PCA1 controller models feature line-voltage relay outputs, making these controllers well suited for use in terminal units. The FX-PCA1- model uses a line-voltage power supply, eliminating the need for a VAC transformer in line-voltage applications. Refer to the FX-PC Series Programmable Controllers and Related Products Product Bulletin (LIT ) or FX-PC Series Programmable Controllers and Related Products for Building Control Management (BCM) System Product Bulletin (LIT ) for product application details. Features Standard BACnet Protocol with BTL Listing - Provides interoperability with Johnson Controls and third-party Building Automation System (BAS) products that use the widely accepted BACnet standard. Selectable BACnet MS/TP or N Field Bus Networking Protocol - Provides a new capability at FX-PCT Release 10.1 that allows FX-PCVs, FX-PCGs, and FX-PCAs to be configured to communicate using either the BACnet or the N field bus networking protocol. Standard Hardware and Software Platform - Uses a common hardware design throughout the family line to support standardized wiring practices and installation workflows. Also uses a common software design to support use of a single tool for control applications, commissioning, and troubleshooting to minimize technical training. ZigBee Wireless Field Controller (FC)/Sensor/Actuator (SA) Bus Interface (where available) - Provides a wireless alternative to hard-wired field bus networking and sensor connections, providing application flexibility, mobility, and minimal disruption to building occupants. State-Based Application Control Logic with Adaptive, Automatically Tuned Control Loops - Prevents simultaneous heating and cooling, reduces commissioning time, eliminates change-of-season re-commissioning, and reduces wear and tear on mechanical devices. Universal Inputs and Configurable Outputs - Allow multiple signal options per channel to provide input/output flexibility. Complete Product Family with Modular Components - Meets any HVAC equipment or building system control requirement using only the needed components. BACnet MS/TP Protocol supports seamless integration into Johnson Controls and third-party BACnet devices. Integral end-of-line (EOL) switch enables FX-PC controller as a terminating device on the communications bus. Wireless capabilities (where available) via an FX-ZFR Series Wireless Field Bus System enable wireless mesh connectivity between FX-PC controllers to FX-WRZ Series Wireless Room Temperature Sensors and to supervisory controllers, facilitating easy initial location and relocation. Patented technologies including Proportional Varying Deadzone Control (PVDC), Pattern Recognition Adaptive Control (PRAC+), and Pulse Modulation Adaptive Control (PMAC) provide continuous loop tuning. Writable flash memory allows standard or customized applications to be downloaded from the FX-PCT and enables persistent application data. Large product family provides a wide range of point mix to meet application requirements and allows for the addition of one or more FX-PCXs or NS Series Network Sensors to provide even more I/O capacity. Support for the FX-DIS17 remote display for monitoring and commanding of I/O and configuration parameters If the product fails to operate within its specifications, replace the product. For a replacement product, contact the nearest Johnson Controls representative. Figure 1: FX-PCA Series Advanced Application Programmable Controllers 1
2 Table 1: FX-PCA Series Point Type Counts Per Model Point Types Signals Accepted FX-PCA11 FX-PCA1-1, FX-PCA311-0A 1 and FX-PCA311-0 Universal Input (UI) Analog Input, Voltage Mode, 0 10 VDC 5 8 Analog Input, Current Mode, 0 ma Analog Input, Resistive Mode, 0 k ohm, resistence temperature detector (RTD) (1k NI [Johnson Controls], 1k PT, A99B SI), negative temperature coefficient (NTC) (10k Type L,.5k Type ) Binary Input, Dry Contact Maintained Mode Binary Input (BI) Dry Contact Maintained Mode Pulse Counter/Accumulator Mode (High Speed), 100 Hz Analog Output (AO) Analog Output, Voltage Mode, 0 10 VDC Analog Current Mode, 0 ma Binary Output (BO) VAC Triac 3 Configurable Output (CO) Analog Output, Voltage Mode, 0 10 VDC Binary Output Mode, VAC Triac Relay Output (RO) Relay Output: Single-Pole, Double-Throw (SPDT) - SPDT Relay Output: Single-Pole, Single-Throw (SPST) 3 - SPST Table : FX-PCA Series Ordering Information FX-PCA11-0 FX-PCA1-1 FX-PCA1- FX-PCA311-0 FX-PCA311-0A 1 17-Point Advanced Application Programmable Controller with UI, BI, CO, 3 BO, and AO; VAC; SA Bus; FC Bus; Integral Real-time Clock 18-Point Advanced Application Programmable Controller with 5 UI, BI, CO, SPDT RO, and 3 SPST RO; VAC; SA Bus; FC Bus; Integral Real-time Clock 18-Point Advanced Application Programmable Controller with 5 UI, BI, CO, SPDT RO, and 3 SPST RO; VAC; SA Bus; FC Bus; Integral Real-time Clock -Point Advanced Application Programmable Controller with 8 UI, BI, BO, and AO; VAC; SA Bus; FC Bus; Integral Real-time Clock; Improved Fast Persistence -Point Advanced Application Programmable Controller with 8 UI, BI, BO, and AO; VAC; SA Bus; FC Bus; Integral Real-time Clock Accessories Table 3: FX-PCA Accessories FX-DIS FX-BTCVT-1 TL-BRTRP-0 FX-ATV FX-ZFR FX-ZFR FX-ZFRCBL-0 FX-BTCVTCBL-700 FX-WRZ Series Wireless Sensors NS Series Sensors YT15-0 Y5A13-0 Local Controller Display. Text only available in English. Bluetooth Commissioning Converter Portable BACnet/IP to MS/TP Router Handheld VAV Box Balancing Tool Wireless Field Bus Coordinator, 10 mw Transmission. Functions with FX Supervisory Controllers. Wireless Field Bus Router, 10 mw Transmission. Functions with FX-PC controllers and FX-WRZxxx Series Wireless Sensors Wire Harness which allows an FX-PCV110/10 to be connected to an SA Bus device (Bluetooth Commissioning Converter, Local Controller Display, or NS Series Sensor) when its SA Bus RJ-1 jack is occupied by an FX-ZFR1811 router. Cable Replacement Set for the FX-BTCVT-1 or the FX-ATV7003-0; Includes One 5 ft (1.5 m) Retractable Cable FX-WRZ Series Wireless Sensors: Refer to the FX-WRZ Series Wireless Room Sensors Product Bulletin (LIT ) for specific sensor model descriptions. NS Series Network Sensors: Refer to the NS Series Network Sensors Product Bulletin (LIT ) for specific sensor model descriptions. Transformer, 10/08/0 VAC Primary to VAC Secondary, 9 VA, Foot Mount, 30 in. Primary Leads and 30 in. Secondary Leads, Class Transformer, 10 VAC Primary to VAC Secondary, 0 VA, Foot Mount (Y5AS), 8 in. Primary Leads and 30 in. Secondary Leads, Class
3 Table 3: FX-PCA Accessories Y5T-0 Y5T31-0 AP-TBKSA-0 AP-TBKFC-0 AP-TBK3PW-0 MS-TBKLV03-0 MS-TBKRO0-0 MS-TBKRO03-0 MS-TBKCO0-0 MS-TBKUI0-0 MS-TBKUI05-0 FX-WRZ780-0 FX-WRZSST-10 ZFR-USBHA Transformer, 10/08/0 VAC Primary to VAC Secondary, 0 VA, Hub Mount (Y5SP+), 8 in. Primary Leads and Secondary Screw Terminals, Class Transformer, 10/08/0 VAC Primary to VAC Secondary, 0 VA, Foot Mount (Y5AR+), 8 in. Primary Leads and Secondary Screw Terminals, Class Replacement MS/TP SA Bus Terminal, -Position Connector, Brown, Bulk Pack Replacement MS/TP FC Bus Terminal, -Position Connector, Blue, Bulk Pack Replacement Terminal, 3-Position Connector, Gray, Bulk Pack Terminal Block Kit - FX-PCA Line Voltage AC - 3 Pieces Terminal Block Kit -FX-PCA -Position Relay Output - 9 Pieces Terminal Block Kit - FX-PCA 3-Position Relay Output - Pieces Terminal Block Kit - FX-PCA -Position Configurable Output - Pieces Terminal Block Kit - FX-PCA -Position Universal Input - 3 Pieces Terminal Block Kit - FX-PCA 5-Position Universal Input - 3 Pieces One-to-One ZigBee Wireless Receiver for Wireless Sensor Only Applications Wireless Sensing System Tool Kit USB Dongle with ZigBee Driver provides a wireless connection through FX-PCT to allow wireless commissioning of the wirelessly enabled FX-PCA, FX-PCG, FX-PCV, and FX-PCX programmable controllers. Also allows use of the FX-ZFR Checkout Tool (FX-ZCT) in FX-PCT. The ZFR-USBHA-0 replaces the IA OEM DAUBI_00 ZigBee USB dongle. For additional information on the ZFR-USBHA-0 ZigBee dongle, refer to the FX-ZFR Series Wireless Field Bus System Technical Bulletin (LIT-10110) or FX-ZFR Series Wireless Field Bus System Quick Reference Guide (LIT-10119). TL-BRTRP-0 Portable BACnet/IP to MS/TP Router FX-PCA Series Technical Specifications Table : FX-PCA Series Technical Specifications s FX-PCA Point Advanced Application Programmable Controller with Integral Real-Time Clock and VAC Supply FX-PCA Point Advanced Application Programmable Controller with Integral Real-Time Clock and VAC Supply FX-PCA1-18-Point Advanced Application Programmable Controller with Integral Real-Time Clock and VAC Supply FX-PCA Point Advanced Application Programmable Controller with Integral Real-time Clock, VAC Supply, and Fast Persistence FX-PCA311-0A 1 -Point Advanced Application Programmable Controller with Integral Real-Time Clock and VAC Supply Supply Voltage FX-PCA11-0, FX-PCA1-1, FX-PCA311-0A, and FX-PCA311-0: VAC (nominal, 0 VAC minimum/30 VAC maximum), 50/0 Hz, Supply Class (North America), SELV (Europe) FX-PCA1-: VAC 50/0 Hz Consumption 1 VA maximum for FX-PCA11-0, FX-PCA311-0A, and FX-PCA VA maximum for FX-PCA1-1 0 VA maximum for FX-PCA1- Note: VA ratings do not include any power supplied to the peripheral devices connected to Binary Outputs (BOs) or Configurable Outputs (COs), which can consume up to 1 VA for each BO or CO, for a possible total consumption of an additional 8 VA (maximum). Ambient Conditions Operating: 0 to 50 C (3 to 1 F); 10 to 90% RH noncondensing; Pollution Degree Storage: -0 to 80 C (-0 to 17 F); 5 to 95% RH noncondensing BACnet/MSTP Controller Addressing N Controller Addressing Communications Bus DIP switch set; valid controller device addresses 17 (Device addresses 0 3 and are reserved and not valid controller addresses.) DIP switch set; valid controller device addresses 1 55 RS-85, selectable between BACnet MS/TP or N: 3-wire FC Bus between the supervisory controller and FX-PC controllers -wire SA Bus between FX-PC controller, NS Series Network Sensors, and other sensor/actuator devices, includes a lead to source 15 VDC supply power (from FX-PC controller) to bus devices. 3
4 Table : FX-PCA Series Technical Specifications Processor H8SX/1xR Renesas microcontroller FX-PCA311-0A and FX-PCA311-0 use RX30 3-Bit Renesas microcontroller Memory Input and Output Capabilities MB Flash Memory and 1 MB Random Access Memory (RAM) FX-PCA11-0: - Universal Inputs: Defined as 0 10 VDC, 0 ma, 0 00k ohm, or Binary Dry Contact - Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode - Analog Outputs: Defined as 0 10 VDC or 0 ma 3 - Binary Outputs: Defined as VAC Triac (selectable internal or external source power) - Configurable Outputs: Defined as 0 10 VDC or VAC Triac BO FX-PCA1-1 and FX-PCA1-: 5 - Universal Inputs: Defined as 0 10 VDC, 0 ma, 0 00k ohm, or Binary Dry Contact - Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode - Configurable Outputs: Defined as 0 10 VDC or VAC Triac BO - Relay Outputs: (Single-Pole, Double-Throw) Rated as UL 91; 1/ hp 10 VAC, 1/ hp 0 VAC; 30 VA Pilot Duty at 10/0 VAC (B300); 3 A Non-inductive -0 VAC; EN 0730: () N.O. or N.C. only 3 - Relay Outputs: (Single-Pole, Single-Throw) Rated as UL 91: 1/ HP 10 VAC, 1/ HP 0 VAC; 30 VA Pilot Duty at 10/0 VAC (B300); 3 A Non-inductive -0 VAC; EN 0730: () N.O. or N.C. only FX-PCA311-0A and FX-PCA311-0: 8 - Universal Inputs: Defined as 0-10 VDC, -0 ma, 0-00k ohms, or Binary Dry Contact - Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode - Binary Outputs: Defined as VAC Triac (external power source only) - Analog Outputs: Defined as 0-10 VDC or -0 ma Analog Input/Analog Output Resolution and Accuracy Terminations Analog Input: 15-bit resolution Analog Output: 15-bit resolution and ±00 mv in 0 10 VDC applications Input/Output: Fixed Screw Terminal Blocks on FX-PCA11-0, FX-PCA311-0A, and FX-PCA311-0 and Pluggable Terminal Blocks on FX-PCA1-1 and FX-PCA1- FC Bus, SA Bus, and Supply : 3-wire and -wire Pluggable Screw Terminal Blocks FC Bus and SA Bus: RJ-1 -pin Modular Jacks Mounting Housing Dimensions (Height x Width x Depth) Horizontal on single 35 mm DIN rain mount (preferred), or screw mount on flat surface with three integral mounting clips on controller Enclosure material: ABS and polycarbonate UL9 5VB; self-extinguishing; Plenum-rated Protection Class: IP0 (IEC59) (except the FX-PCA1 controller) FX-PCA11-0: 150 x 190 x 53 mm (5-7/8 x 7-1/ x -1/8 in.) including terminals and mounting clips FX-PCA1 Models: 150 x 1 x 53 mm (5-7/8 x -7/1 x -1/8 in.) including terminals and mounting clips FX-PCA311-0A 1 and FX-PCA11-0: 150 x 0 x 57.5 mm (5-7/8 x 8-3/ x -3/8 in.) including terminals and mounting clips Note: Mounting space for FX-PCA models requires an additional 50 mm ( in.) space on top, bottom, and front face of controller for easy cover removal, ventilation, and wire terminations. Weight 0.5 kg (1.1 lb)
5 Table : FX-PCA Series Technical Specifications Compliance United States: UL Listed, File E10701, CCN PAZX, UL 91, Energy Management Equipment; FCC Compliant to CFR7, Part 15, Subpart B, Class A Canada: UL Listed, File E10701, CCN PAZX7, CAN/CSA C. No. 05, Signal Equipment; Industry Canada Compliant, ICES-003 Europe: CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 00/108/EC. Johnson Controls, Inc., declares that the FX-PCA1- models are also in compliance with the essential requirements and other relevant provisions of the Low Voltage Directive 00/95/EC. Declared as Independently Mounted, Intended for Panel Mounting, Operating Control Type 1.B, kv rated impulse voltage. 100ºC ball pressure test. Australia and New Zealand: C-Tick Mark, Australia/NZ Emissions Compliant BACnet International: FX-PCAxx Models - BACnet Testing Laboratories (BTL) Protocol Revision 7 Listed BACnet Advanced Application Controller (B-AAC) FX-PCA311-0A and FX-PCA BACnet Testing Laboratories Protocol Revision 9 (BTL) Listed BACnet Advanced Application Controller (B-AAC) Building Efficiency 507 E. Michigan Street, Milwaukee, WI 530 Johnson Controls is a registered trademark of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 015 Johnson Controls, Inc. Published in U.S.A. 5
Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT-1900349 Issued April 17, 2015
Code No. LIT-190039 Issued April 17, 015 Refer to the QuickLIT website for the most up-to-date version of this document. The Input/Output Module () Series Controllers are BACnet Application Specific Controllers
FX07 Field Controller
Product Bulletin FX07 Field Controller Issue Date March 25, 2008 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,
FX07 Field Controller
Product Bulletin FX07 Field Controller Issue Date May 5, 2011 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,
Network Control Engine Product Bulletin
MS-NCE25xx-x Code No. LIT-12011283 Software Release 7.0 Issued December 5, 2014 The Metasys Network Control Engine (NCE) Series controllers provide a cost-effective solution designed for integrating central
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Metasys System Field Equipment Controllers and Related Products Product Bulletin
Metasys System Field Equipment Controllers and Related Products Product Bulletin Code No. LIT-004 Issued April 06 Overview The Metasys system family of Field Equipment Controllers comprises a group of
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
FX16 Master Controller
Product Bulletin FX16 Master Controller Issue Date October 20, 2008 FX16 Master Controller The FX16 Master Controller is a high performance field controller designed specifically for commercial Heating,
M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators
M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators Product Bulletin Code No. LIT-1201742 Issued February 12, 2015 The M9102 and M9104 Series Actuators are directmount,
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack
Compatible with SmartStruxure solution SmartStruxure Lite solution Room Controllers Line Voltage Fan Coil Room Controller with SC3000 Relay Pack Application specific controller with customizable covers
Portable BACnet /IP to MS/TP Router
Portable BACnet /IP to MS/TP Router Installation Instructions TL-BRTRP-0 Part No. 24-10414-2, Rev. F Issued April 2016 Refer to the QuickLIT website for the most up-to-date version of this document. Applications
BACnet. bcx1 Controller/ Router Series
BACnet bcx1 Controller/ Router Series The Andover Continuum TM bcx1 Series is a series of Native BACnet routers and controller/routers which heads up the BACnet family of Andover Continuum controllers.
English plain text messages with constant backlight that brightens during user interaction. On/Off, Floating, or Proportional 0 to 10 VDC Control
TEC26x6(H)-4 and TEC26x6H-4+PIR Series BACnet MS/TP Networked Thermostat Controllers with Dehumidification Capability, Fan Control, and Occupancy Sensing Capability Product Bulletin Code No. LIT-12011587
NCE25 Installation Instructions Part No. 24-10143-63, Rev. L Software Release 7.0 Issued December 5, 2014
MS-NCE25xx-x Part No. 24-10143-63, Rev. L Software Release 7.0 Issued December 5, 2014 Application The Metasys Network Control Engine (NCE) 25 Series controllers combine the network supervisor capabilities
3466 Building Energy Management Training Systems
3466 Building Energy Management Training Systems LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2015 Table of Contents General Description 3 Courseware 3 Topic Coverage 4 List of Available
CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter
CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter Product Bulletin CD-Pxx-00-1 Code No. LIT-216525 Issued December 6, 2010 Supersedes September 12, 2008 Johnson Controls offers a complete line of Carbon Dioxide
HMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
Model: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM
TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution
MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
ComfortPoint Open Building Management System. For consultants and specifiers. The Simply Smart way to optimize building control and performance
ComfortPoint Open Building Management System For consultants and specifiers The Simply Smart way to optimize building control and performance ComfortPoint Open BMS. Simply Smart. The Honeywell ComfortPoint
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Protects against unwanted thermostat controller tampering. Increases occupancy comfort by providing dehumidification.
TEC22x6(H)-4 and TEC22x6H-4+PIR Series LONWORKS Network Thermostat Controllers with Dehumidification Capability, Fan Control, and Occupancy Sensing Capability Product Bulletin Code No. LIT-12011607 Issued
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
Climate Ready Control Systems Technical Specifications
Climate Ready Control Systems Technical Specifications Climate Ready Control Systems Climate Ready Control Systems consist collectively of motor controllers, other hardware and software packages that will
T5000 T000 LCD Digital Fan Coil Thermostat
T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected
Niagara Security Overview Niagara Security by Tridium, is an open, web-based security management solution that allows you to manage and monitor your facility anytime, anywhere. Built on Tridium s Niagara
TAC I/NETTM MR-AHU-HP. Application Specific Controller
TAC I/NETTM MR-AHU-HP Both the MR-AHU and MR-HP controllers are application specific controllers (ASCs). The intention of the design is to reduce total install cost through pre-engineered control algorithms
System 350 A350E Electronic Cooling Control
FANs 930, 930.5, 125, 121 Product/Technical Bulletin A350E Issue Date 0899 System 350 A350E Electronic Cooling Control The A350E is an on/off, electronic, cooling-only control with Single-Pole, Double-Throw
Foxboro Evo Process Automation System
Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Unidirectional Transmitter/ Receiver Units Introduction
Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
A-307. Mobile Data Terminal. Android OS Platform Datasheet
A-307 Mobile Data Terminal Android OS Platform Datasheet Revision 1.1 July, 2013 Introduction A-307 Platform Overview Introduction A-307 Platform Overview The A-307 provides Original Equipment Manufacturers
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
A-317. Mobile Data Terminal. Android Platform Datasheet
A-317 Mobile Data Terminal Android Platform Datasheet Revision 1.4 October, 2014 Disclaimer: Micronet reserves the right to change product specifications without prior notice. Introduction A-317 Platform
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Disturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module
DATASHEET NI 9423 8-Channel Sinking Digital Input Module 8-channel, 100 µs digital input 24 V logic, sinking digital input Compatible with NI CompactDAQ counters 250 Vrms, CAT II isolation 10-position
Tracer Summit Web Server
Tracer Summit Web Server Web-based access for the Tracer Summit building automation system March 2003 BAS-PRC014-EN Introduction The Tracer Summit Web Server provides the ability to operate a Tracer Summit
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
QuickSpecs. Models HP Server Console Switches
Overview are key components for rack mount implementations (a console represents one keyboard, video monitor, and mouse (KVM) attached to a server). The family of allows multiple servers in a rack to be
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
AIS750 Series Alarm Annunciator
Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS
VMC A4 INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS PRODUCT DATA SHEET FEATURES RF to 0-10 VDC out, analogue or PWM Maximal 3 digital inputs to RF RF communication with other equipment Wireless
MS/TP Communications Bus Technical Bulletin Code No. LIT-12011034 Software Release 7.0 Issued July 2, 2015
Code No. LIT-12011034 Software Release 7.0 Issued July 2, 2015 Refer to the QuickLIT website for the most up-to-date version of this document. Document Introduction...3 Related Documentation...3 MS/TP
3468-00 Lighting and Fire Alarm Training System Add-On
3468-00 Lighting and Fire Alarm Training System Add-On LabVolt Series Datasheet Festo Didactic en 06/2016 Table of Contents General Description 2 List of Equipment 2 List of Manuals 2 Additional Equipment
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
UniPi technical documentation REV 1.1
technical documentation REV 1.1 Contents Overview... 2 Description... 3 GPIO port map... 4 Power Requirements... 5 Connecting Raspberry Pi to UniPi... 5 Building blocks... 5 Relays... 5 Digital Inputs...
DC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
Product Data. Thermal Comfort Data Logger Type 1221. Including Application Software Type 7301
Product Data Thermal Comfort Data Logger Type 1221 Including Application Software Type 7301 USES: For measuring all physical parameters necessary to evaluate heat stress and thermal comfort For evaluating
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
SMART Board 685ix interactive whiteboard system Model 685ix
Specifications SMART Board 685ix interactive whiteboard system Model 685ix Physical specifications SMART Board 685ix interactive whiteboard 77 1/2" W 49 1/2" H 5 1/8" D Size (196.9 cm 125.7 cm 13 cm) Active
NX safety stand-alone
NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
NETWORK ENABLED EQUIPMENT MONITOR
NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone
Hand-held thermometer Model CTH7000
Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h
SMART Board interactive flat panel with appliance Model 8055ie-SMP
Specifications SMART Board interactive flat panel with appliance Model 8055ie-SMP Physical specifications Size 52 3/8" W 32 5/16" H 3 11/16" D (133 cm 82 cm 9.3 cm) (See Physical dimensions on page 7 for
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
3200L 32" Interactive Digital Signage Touch Display
3200L 32" Interactive Digital Signage Touch Display The 3200L Interactive Digital Signage (IDS) display combines precision Elo touch screen technology with a professional-grade, large format LCD panel.
P70, P72, and P170 Series Controls for Dual Pressure Applications
P70, P72, and P170 Series Controls for Dual Pressure Applications Product Bulletin Code No. LIT-125455 Issued August 30, 2012 Supersedes September 1, 2000 The P70, P72, and P170 controls for dual pressure
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
Auto-tune PID. Temperature Controller BRAINCHILD FEATURES
Auto-tune PID Temperature Controller FEATURES Easy-to-use Fuzzy modified PID heat & cool control Fast A-D sampling rate (5 times/s) Universal input (PT100, thermocouple) with high accuracy 18-bit A-D Analog
Scout 1U Rackmount Computer
Model Numbers ACC-CPU-RM- WIN7x64 ACC-CPU-RM-2008 Revision 5 Scout 1U Rackmount Computer Introduction The Scout 1U Rackmount Computer includes a solid state hard drive loaded with the Microsoft Windows
Automation Unit TM 1703 ACP Flexible automation and telecontrol
Automation Unit Flexible automation and telecontrol Power Transmission and Distribution Outstanding performance: Automate simply with Highly complex and yet fully transparent automation solutions are not
SCADAPack 530E 535E. remote Programmable Automation Controller
SCADAPack 530E 535E remote Programmable Automation Controller 1 With the SCADAPack 500E range, Schneider Electric introduces the first ever remote Programmable Automation Controller (rpac). This data sheet
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip
NI 6585 Specifications This document lists the specifications of the National Instruments 6585 FlexRIO low-voltage differential (LVDS) adapter module. Pair these specifications with your FPGA module specifications.
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.
SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
www.vicon-security.com
Data/Spec Sheet 16-Channel Hybrid Digital Video Recorder Configured with ViconNet Video Management Software (VMS) Scalable from one to hundreds of recorders Support for HD video and Megapixel cameras Real-time
3500/22M Transient Data Interface
3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery
T7079A,B Solid State Remote Temperature Controllers
T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature
Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:
GE Measurement & Control Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
IntesisBox KNX - LON
IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
KNX Panasonic Air Conditioners
IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line