T-Extender E-Extender



Similar documents
F2400 FOM II Series Fiber Optic Modem Technical Manual

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

RLH 2 Wire Digital Phone Fiber Link Card System

VOICE RECORDING SYSTEM ISDN PRI / BRI

Model SRMD Setra Remote Monitoring Display

PagePac PAGEPAL V

Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

USB Port Extender Kit

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

2-Pair HDSL1 Adtran Fiber Optic Link System

INSTRUCTION MANUAL T1 TO RS422 INTERFACE

16/32 Channel 1U Rack Mount CCTV Power Supply

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

Advantium 2 Plus Alarm

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

PEDAL POWER. User s Manual

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Cabling Specifications

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Contents. Safety Warnings... 1

Component With Audio. Model # COMP-2-HDMI-AD USER MANUAL.

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Extender for HDMI 1.3 over CAT6. GTV-HDMI1.3-CAT6 User Manual.

TCB-2 Auto Answer Coupler Product Manual

16-Port and 24-Port 10/100 Switches

FlexPoint T1/E1 Copper to Fiber Line Driver

MusicTel-60. Music on-hold SYSTEM. Installation Manual

USB Rover port USB m Cat 5 Extender. User Guide

USB Port Hub with USB Power Cable. User s Manual

AXIS T81B22 DC 30W Midspan

Standards Affecting a Premise T-1 Installation

Gigabit Switching Ethernet Media Converters - Product User Guide

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

Audio, power, and control data

LDG DTS-4/4R Desktop Coaxial Switch / Remote

HP UPS R1500 Generation 3

PS 155 WIRELESS INTERCOM USER MANUAL

Universal Quick Install Guide Quantum and Triton Boards

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

Universal Quick Install Guide Quantum and Triton Boards

Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap

TTL to RS232 Adapter User Guide

VK-250 WARRANTY REGISTRATION FORM

2X1 DVI Switch (DS-21R) 4X1 DVI Switch (DS-41R) USER MANUAL. DTronics Inc.

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

Owner's Manual. Assembly Instructions. Warranty. This Product is Produced Exclusively by Tan Black

RLH Single Channel T1 Fiber Link Card System

5006 Centrex AuxBox. Call Recording for Meridian Digital Centrex Telephones. Hardware & Installation Guide

INSTALLATION. Omega 8000 Series Controller For Use With Omega 90 Siren/P.A. Amplifier

Model 201 Wiegand Touchpad Reader Installation Guide

OPERATION FIC SOC (USOC) JACK T1 CSU Interface 04DU9-1SN 6.0N RJ48C 04DU9-1ZN

Cable Specifications. T3 Trunk Cabling APPENDIX

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

USER GUIDE. 2 Channel POTS Mux DIN Fiber Link System. Introduction SYSTEM INSTALLATION INFORMATION. The leader in rugged fiber optic technology.

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

OVERVIEW NETWORK INTERFACE MODULES

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

DV-1D Data/Voice DSU TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...8 SECTION 3 - INSTALLATION...11

Ethernet Patch Cord Wiring

KVM - DVI, USB 2.0, Cat 5 Extender

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

VDSL Ethernet Extender AT-MC605. Installation Guide Rev. C

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Cable Pinouts. SRP I/O Module

No Phone Line System. Quick Start Guide NPL II. 1.0 Installation

GEU Port Gigabit Switch

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

HDMI over Cat5 Video Extender with RS232 and IR Control

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

T1 Backhaul Connectivity Solution All Products :: Application Note

IP DSLAM IDL Quick Installation Guide

Single Station Remote Alarm

USB/VGA Cat 5 UTP Console Extender

Moxa EtherDevice Switch

8-Port 10/100M N-Way Mini Switch

MS900AC-B-LS User Information

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

DDP-3 Engineering Guide

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

Single Port Gigabit Ethernet Media Converter Board (P/N xxx) User s Manual And Troubleshooting Guide

Installation and User Guide

Solar monitoring gateway quick start guide

Model 0400 (800) MODEL 0400 ETHERNET POCKET HUB SPECIFICATIONS (E-TBT-HB-0400) Standards. Physical

BACnet Automation Interface Module (Network Version)

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

ADSL Modem Installation Guide. Model # 36R515 Part # Rev. D Revision Date 12/2000. ADSL Modem Installation Guide

How To Connect A 2262 To A Fiber Optic Cable

T1 Networking Made Easy

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

BroadBand PowerShield. User Manual


Transcription:

T-Extender E-Extender TABLE OF CONTENTS SECTION - DESCRIPTION... SECTION - SPECIFICATIONS...3 SECTION 3 - INSTALLATION... SECTION - FRONT PANEL INDICATORS...7 SECTION - INTERFACE SIGNALS AND CABLES...8 SECTION 6 - TROUBLESHOOTING... SECTION 7 - WARRANTY...3 Data Comm for Business, Inc. PO Box 639 Champaign, IL 686-639 December, 009 7-897-6600 www.dcbnet.com 8000

. DESCRIPTION The DCB T-Extender and E-Extender are -wire repeaters for use on customer owned lines or to extend telephone company lines. The Extenders are used to extend in-house T- or E- lines in campus and high-rise environments. Each pair of T-/E- Extenders may be located up to 000 feet apart. The Extender circuitry is rated to 36 db dynamic range at the T- rate of. Mbps and 3 db dynamic range at the E- rate of.08 Mbps. As implemented, the parts are slightly de-rated to provide long life at extended temperature range. Therefore the distances specified in this document are only 000 feet. Solid copper AWG, two twisted pair is the preferred cable for connection between the Extenders. Connection to the Extender is made through RJ8 modular connectors or -wire screw down terminal blocks. Each Extender comes standard with two screw down terminal blocks and two RJ8 adapters. If only RJ8 connections are desired extra RJ8 adapters (part number 90 to connect to telco, 907 to connect to customer equipment) can be ordered. The DCB T-Extenders and E-Extenders are powered by a small wallmount transformer. The Extenders are designed for connections between T- equipment such as PBXs, T-/E- multiplexers, T-/E- line drivers, CSUs, routers or any other T-/E- equipment requiring long customer owned cable runs. T-Extenders and E-Extenders can be used to connect this equipment across a campus, between floors of a high-rise office building or between office buildings with underground cable runs. The T-Extender/E-Extenders are transparent to the type of data sent over the T-/E- link. The data can be D- format, ESF, PRI, G.703, G.70, etc. The T-Extenders are most often used in pairs to extend a telephone company demarc. For example, if a CSU or DSU is limited to 6 feet and is connecting to a phone company smart jack demarc which is limited to 6 feet, the T-Extenders are used in pairs to extend that distance up to 000 feet. Features Actively repeats the T and E signals RJ8 or screw down connectors Power options 0 or 0 VAC;,, 8, or VDC U high rack mountable,,, or 3 x 9 rack 0 slot rack chassis option DIN mount option

. SPECIFICATIONS. General T- repeater or E- repeater Extends T- or E- bi-polar signals Up to 000 feet between T-Extenders Up to 000 feet between E-Extenders Indicators Power Accessories RJ8 wiring adapters P/N 90 and 907 (included) RJ to RJ straight through cable P/N 90009 RJ to RJ crossover cable P/N 900099 Rack shelf, U for to 3 T-Extenders 0 slot, U high 9 rack mount chassis. T Output Level: 0.dBdsx, 7.0dBm, 6.3v p-p Input Sensitivity: -36dB.3 Wire Two twisted pair solid copper. T/E In and Out Connectors RJ8 modular 90 907 Pin - In Receive Transmit Pin - In Receive Transmit Pin - Out Transmit Receive Pin - Out Transmit Receive -Wire terminal block Receive - In Receive - In Transmit - Out Transmit - Out Connect the transmit pair of one Extender to the receive pair of the other Extender. Pairs are not polarity sensitive. Units are supplied with screw down and RJ8 adapter connectors (one each 90 and 907) 3

. Physical/Electrical. x 7. x. 00 ohm T-, 0 ohm E- interface lbs including wall transformer 0 VAC external wall transformer supply Optional 0 VAC,,, 8, VDC 30 ma.6 Environmental -0 to +70 C operating temperature

3. INSTALLATION 3. Unpacking The following is included with each unit: Unit and external power supply Two RJ8 to terminal block adapters. One provides an equipment interface the other provides a network interface. Manual Information regarding warranty, maintenance contracts and repair 3. Location Place the unit in a clear area where you can reach the rear panel to connect the cables. The unit has an external power supply that requires a 0 VAC outlet. The total power cord length is about 6 feet. 3.3 Connections On the unit, transmit is an output, receive is an input. When connecting units to each other, the transmit of one unit must be connected to the receive of the other. Pairs are not polarity sensitive. See Section for connector pinouts. Cables for connecting the units to the telco demarc and a DSU/CSU or router are available from DCB. See Section for part numbers. NOTE Cable should be Category 3, twisted pair, shielded. DO NOT use Category cable unless absolutely necessary. If Cat cable must be used, use separate bundles for the and pairs. Location Location Demarc RJ8C T-Ext T-Ext CSU or Router Pins & & Pins & & Connections for most applications.

Location Location PBX or Router T-Ext T-Ext PBX or Router & & & & Equipment to Equipment connections. The supplied RJ8 adapters allow all of the above connections to be made using straight through wired RJ to RJ cables (patch cords). For connection to a TELCO Demarc use the adapter labeled To TELCO Net, P/N 90 (green circuit board). To make the crossover connection between two T/E-Extenders use adapter To TELCO Net, P/N 90 on one unit and P/N 907, To Cust Equip (blue circuit board) on the other. To connect to customer equipment such as a Router, DSU or PBX, use the adapter labeled To Cust Equip, P/N 907 (blue circuit board). NOTE If making an equipment to equipment connection you will need to order one additional RJ8 adapter, P/N 907, To Cust Equip, (blue PCB). OR Use the terminal block connectors for connection between units. 6

. FRONT PANEL INDICATORS. Indicators Indicator Condition Meaning Power ON Power is applied to the unit. T-EXTENDER POWER DCB 7

. INTERFACE SIGNALS AND CABLES. Connector Location and Pin Reference TX RX TX RX Power TX TX RX RX Rear Panel and Connectors 3 6 7 8 RJ Positions 8

. T- Interface.. Terminal Block Signal Receive Receive Transmit Transmit In/Out IN IN OUT OUT.. RJ8 Adapter, To TELCO Net P/N 90 (Green) Pin Signal In/Out Receive IN Receive IN 3 not used Transmit OUT Transmit OUT 6 not used 7 not used 8 not used Use this adapter and a straight through cable to connect to a TELCO Demarc (Network) interface...3 RJ8 Adapter, To Cust Equip P/N 907 (Blue) Pin Signal In/Out Receive OUT Receive OUT 3 not used Transmit IN Transmit IN 6 not used 7 not used 8 not used Use this adapter and a straight through cable to connect to an Equipment (DSU, Router, PBX, etc.) interface. 9

.3 Cables.3. Extender to TELCO Demarc using RJ8 adapter 90. This cable is available from DCB, P/N 90009. RJ- RJ- DEMARC RJ-8C Extender Terminal Block 68B Cable ORG Pair BLU Pair.3. Extender to another Extender using RJ8 adapter 90 on both. This cable is available from DCB, P/N 900099. RJ- RJ- Terminal Block Terminal Block NOTE If one adapter 90 and one 907 are used then this connection can be made using straight through RJ to RJ wiring. 0

.3.3 Extender to a DSU/CSU, PBX or Router with RJ8 interface using RJ8 adapter 90. This cable is available from DCB, P/N 900099. RJ- RJ- Equipment RJ-8 ORG 68B Cable Extender Terminal Block Pair BLU Pair.3. Extender to a DSU/CSU with DA- interface RJ- DA- 9 3.3. Sources for Individually Shielded Twisted Pair Cable: Beldon # 7838A Comm Scope # 0D General Cable # 706880 Madison Cable # 03 Quabbin Wire & Cable # 9770

6. TROUBLESHOOTING 6. General Approach When troubleshooting problems, a rational plan can save you many hours of frustration. The following is a brief outline of standard troubleshooting procedures.. Gather the facts to determine the exact nature of the problem.. Draw a picture of the system showing the equipment at both ends and the in-house wiring. Use this as a reference to note your observations, test steps and test results. A picture keeps you focused and often saves duplicate effort. 3. If you change anything, change only one thing at a time. 6. Common Problems The most common problems when installing T/E-Extenders are wiring problems. Wiring problems fall into two categories; incorrect cable type and improper connections. We recommend using only Category 3, two twisted pair, shielded cable. Category, e, or 6 cable should not be used. If cat. cable must be used, it is recommended that one pair be used from each of two separate cat. cables to minimize cross-talk (NEXT). When connecting T/E-Extenders be sure that outputs are connected to inputs and inputs are connected to outputs. See diagram on page and interface information in Section. 6.3 Assistance If you need assistance troubleshooting your system, contact DCB customer support at (7) 897-6600 between 8:00 am and :00 pm central time Monday through Friday.

7. WARRANTY DCB products are warranted to be free of defects in materials and workmanship for two years. Data Comm for Business, Inc. will repair or replace any equipment proven to be defective within the warranty period. All warranty work is F.O.B. Dewey, IL. This warranty is exclusive of abuse, misuse, accidental damage, acts of God or consequential damages, etc. DCB liability shall not exceed the original purchase price. All equipment returned for warranty repair must be accompanied by a Returned Material Authorization (RMA) number. To receive an RMA number, call (7) 897-6600 between the hours of 8 AM and PM central time. Equipment must be shipped prepaid to DCB and will be returned at DCB's expense. Ship returned items to: Data Comm for Business 99 County Road 000E Dewey, IL 680 ATTN: your RMA number Data Comm for Business, Inc. PO Box 639 Champaign, IL 686-639 Tel (7) 897-6600 Fax (7) 897-33 3