CARDIOHELP INTERFACE PRESENTER (CIP) USER GUIDE GENERAL INFORMATION ABOUT THE CIP:



Similar documents
CARDIOHELP BASIC TRAINING

HLS Set Advanced Integration meets innovation

Conferencing Moderator Guide

REC FIM LOCKPICK INSTALLATION OPTIONS

Section III. Heart Mate II (2 nd Generation) III.41.1 EMT-BASIC EMT-INTERMEDIATE EMT-PARAMEDIC

PROFESSIONAL DIGITAL TWO-WAY RADIO MOTOTRBO ANYWHERE. for ios USER GUIDE

SD1 SPEECH DIALLER OPERATING INSTRUCTIONS SD1 ESC ENT

Part 2. Copyright 1998 Philips Consumer Communications L.P. All rights reserved. Printed in Mexico. Issue 1AT&T

CONTENTS 4. HOW TO UNSET THE PANEL...7

Carry it Easy. User Guide

Impact Uni-Vent 754 Portable Ventilator

Carry it Easy +Plus Bio. User Guide

ADOBE CONNECT 8 USER GUIDE. Colorado Department of Labor & Employment

Windows XP Pro: Basics 1

Wireless Setup Guide. Before you start please ensure:

Get started. Issue 1

Single-Needle Cross-Over System. Brief description

user manual It is important to read this user manual prior to using your new product for the first time.

Extracorporeal life support PLS System

Impact Uni-Vent 750 Portable Ventilator

Library and IT Services. 7. Help button You can retrieve information on a specific function via the help button and consequently use a soft button.

FREQUENTLY ASKED QUESTIONS

Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: R. CareGard. User Guide

Getting Started with Adobe Connect. Div of IT Learning Technologies

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

Thank you for choosing HUAWEI Mobile WiFi

Instructions to Sign On and Off of Self Service Applications. Internet Explorer 9 (IE9) Users: Turn Off Compatibility View:

1. Application Overview System Requirements Installation Splash Screen Registration Screen...

Unified Meeting 5 User guide for MAC

User Guide. Memo S580.

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

BLU Vivo 4.3 User Manual

ON24 MOBILE WEBCASTING USER GUIDE AND FAQ FEBRUARY 2015

SCORPION. micron security products

SW10. User Guide. Smart Watch. Please read the manual before use.

MOBILE APP TRAINING MANUAL

USER GUIDE FOR ANDROID DEVICES

Getting to Know Xsight Home Screen and Everyday Use Settings PC Setup

Microsoft Migrating to PowerPoint 2010 from PowerPoint 2003

USER GUIDE FOR ANDROID DEVICES

VHS Copying with Nursing Mobile Recorder

Frequently Asked Questions for logging in to Online Banking

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

Password Depot for Android

GUIDE GETTING STARTED IMPORTANT SUPPORT RESOURCES

Summary Table Voluntary Product Accessibility Template

Firmware update for iphone with Lightning connector compatible with AppRadio Mode

Operation Manual Videohub Software Control. Mac OS X Windows

The following information can be output as speech: status of the teacher / student connection. time markers of the timers.

User Guide PUSH TO TALK PLUS. For Android

Content Get Started... 3 Insert SIM card and Memory Card...3 Charging the Battery or Connect to a Computer...4 PAD Overview...

HP Advanced Wireless Docking Station. User Guide

Sharing Software. Chapter 14

JVC CAM Control (for ipad) User Guide

user guide the conference call people Simple Effective Collaboration

Speech and Debate Timekeeper User Manual

Installation and Operation Back-UPS 1250, 1300, 1500

MAINTENANCE & TROUBLESHOOTING

Mikogo User Guide Linux Version

NFC technology user guide. Contactless payment by mobile

Avira Free Android Security (version 1.2) HowTo

SweetPea3R-200 User Guide Version 1.1

Version 1.0. PNY DUO-LINK 4 User Manual

Regents of the University of Michigan 5/7/2015. Review pump functionality, sets and accessories Understand key process steps for

Networking Guide Redwood Manager 3.0 August 2013

MAINTENANCE & TROUBLESHOOTING

GROUPTALK FOR ANDROID VERSION for Android

The instructions in this user guide will help make meetings easier to manage, more effective and more productive.

How to Use Your Companion Service Two-Way Voice Unit A personal response system from the #1 security company in America.

Fi Phone Quick Start Guide

G-100/200 Operation & Installation

ZeppelinAir AirPlay. set up

Xerox WorkCentre 6655 Color Multifunction Printer Control Panel

Fiery E100 Color Server. Welcome

CareSentinel Set Up Guide for Android Devices

HDCVI Series DVR Quick Start Guide

Adaptive cruise control (ACC)

How-To: Changing the target IP address for pcanywhere Remote Control

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

System Tel (Telephones) Ltd Fax Web

An Informational User Guide for: Web Conferencing

How to install Radiance on your computer via a virtual machine

Adobe Connect Support Guidelines

User Guide FOR TOSHIBA STORAGE PLACE

Seagate Manager. User Guide. For Use With Your FreeAgent TM Drive. Seagate Manager User Guide for Use With Your FreeAgent Drive 1

Desktop Messenger 4.9 USER GUIDE

Password Depot for ios

Online Sharing User Manual

Help. F-Secure Online Backup

Using your LED Plus keypad

How to Use Your Companion Service Two-Way Voice Unit.

Smoke Density Monitor application documentation

Thank you for choosing the HUAWEI EC5805 Wireless Modem (E5).

Combi B PC software 8213X. Installation and operating instructions

CONTENTS. 1. Fitting the Battery

Online Testing Checklist for Summer 2016 Ohio s State Test Administrations

Welcome to Bell Aliant NextGen Home Security

TELEPHONE BUTTONS & ICONS TOUCHSCREEN OVERVIEW

USB Flash Memory TransMemory-EX II TM

DAY OF TESTING GUIDE. Contact Information. Websites. Please do not bookmark the Proctor Interface or the Student Interface.

Transcription:

CARDIOHELP INTERFACE PRESENTER (CIP) USER GUIDE GENERAL INFORMATION ABOUT THE CIP: The CARDIOHELP Interface Presenter is a sales support tool. It gives sales staff the chance to get to know the new CARDIOHELP software and, at the same time, offers the possibility of demonstrating the intuitive and user-friendly operating concept of the new CARDIOHELP software without taking the CARDIOHELP-i along. The CIP is not a simulation tool as it is not possible to manipulate values. The CARDIOHELP Interface Presenter is run in the browser of your computer/laptop. Versions for Internet Explorer/Google Chrome and Mozilla Firefox/Safari are available to download. Please note that if you download the wrong version or if you use an old browser version, it might not be possible to run some features of the Presenter correctly. When the CIP files are downloaded a folder named maquet-cip-fs or maquet-cip-ec respectively will be created. To run the CIP you have to unzip the files first. You need the content of the whole folder so keep all the files together. Don t rename the files and folders as they are linked with each other. In addition to the browser versions, an ipad version is also available. Should you have any questions on how to install the CIP on your ipad and the differing operating features of the ipad version, please consult the document Installation Manual ipad. The Presenter includes all the screens you need to present the software. However, it must be noted that the CIP does not show all the functions of the new CARDIOHELP software 100% identically. For this reason, we strongly recommend that you familiarize yourself with the program before presenting the CIP for the first time. The original audio tones are included both when you start the CIP and in the integrated simulations. Please remember to turn on the speakers on your machine when doing the presentation. For information on how to play the audio tones in the ipad version, please read the document Installation Manual ipad. For the computer/laptop versions, we recommend clicking through the CIP once before holding your first presentation for a customer. This saves the screens in the cache, accelerating the loading of the pages the next time they are opened. MAQUET Cardiopulmonary AG Kehler Strasse 31, 76437 Rastatt, Germany, Phone: +49 (0)7222 932-0, Fax: +49 (0)7222 932-1888 1/6

STARTING THE CIP: As the CIP is run in the browser, the standard browser controls are visible. To minimize these during the presentation, press F11. Activating the power-on button starts up the CARDIOHELP-i. At this stage, the device performs a self test. The status is displayed via the progress bar: Once the device has started, the thapp menu is shown. This does not correspond to what actually happens on the CARDIOHELP-i. The device usually always starts in the last-used therapy application. The required application can be selected in the thapp menu. Realistic values are shown for every application. These reflect a typical patient condition for the application in question. There are 5 applications available: MAQUET Cardiopulmonary AG Kehler Strasse 31, 76437 Rastatt, Germany, Phone: +49 (0)7222 932-0, Fax: +49 (0)7222 932-1888 2/6

Veno-arterial circulatory and pulmonary support (v-a ECLS) Ventricular support with a centrifugal pump (VAD) Extracorporeal circulation for interventions lasting up to 6 hours employing systems with reduced foreign surfaces (MECC) Veno-venous pulmonary support (v-v ECLS) Extracorporeal CO 2 elimination with low blood flow rates (PALP) ADDITIONAL INFORMATION SCREEN In addition to reproduction of the original CARDIOHELP user interface, the CIP also features an integrated screen with information about all aspects of CARDIOHELP. You can access this screen by clicking on the thapp icon in the top left corner of the respective screen: You can return to the CARDIOHELP interface via the Back to CIP button: MAQUET Cardiopulmonary AG Kehler Strasse 31, 76437 Rastatt, Germany, Phone: +49 (0)7222 932-0, Fax: +49 (0)7222 932-1888 3/6

Disposables & Accessories: This section contains information on the sets that can be operated with the respective thapp in addition to images and videos on the topics of Catheters & Cannulae and Transport, as well as a picture of a fully equipped sprinter cart. When the fully equipped sprinter cart is opened, the individual components are named by means of mouse-over effects. CARDIOHELP Front Connectors: Clicking on the Front Connector image enlarges it. Mouse-over effects are also integrated here to name the different connectors on the CARDIOHELP-i. Simulations: This section can be used to directly select the simulations integrated in the CIP. Further information on the topic of simulations can be found in the Background Information on Simulations section of this guide. Link to CARDIOHELP microsite: To make it simple to access further information concerning CARDIOHELP, a direct link to the CARDIOHELP microsite is integrated in the CIP. This link is not enabled in the ipad version as the ipad is not capable of displaying the microsite. BACKGROUND INFORMATION ON SIMULATIONS: There are eight simulations integrated in the CIP. These simulations show possible events that might arise when using the respective thapp. The simulations can be selected via the additional information screen or directly within the respective application: Below you will find some background information on the individual simulations. This information can be used as a basis for what to say in your presentation: Backflow Prevention, can be selected via: Especially during the start phase or during the process of weaning a patient off extracorporeal support, a backflow may occur against the foreseen direction of flow due to the higher pressure in the arterial vascular system. This will be detected by the CARDIOHELP-i. A negative flow first triggers a low-priority alarm. After 6 seconds, the Backflow Prevention is initiated automatically. The CARDIOHELP-i will select the necessary RPM automatically to maintain the flow whilst stopped. A high-priority alarm will be triggered simultaneously. This scenario is demonstrated in the simulation. Additional information on Backflow Prevention : The user can cancel the Backflow Prevention by pressing the zero flow button and setting the required flow with the rotary knob. With the Backflow Prevention function we prevent an arteriovenous short circuit and thus guarantee an improved flow and pressure situation in the arterial vascular system. MAQUET Cardiopulmonary AG Kehler Strasse 31, 76437 Rastatt, Germany, Phone: +49 (0)7222 932-0, Fax: +49 (0)7222 932-1888 4/6

Battery supply, can be selected via: When the mains current is interrupted, the internal batteries automatically assume the task of supplying the CARDIOHELP-i with power. The switching to battery operation is accompanied by a low-priority alarm in order to rule out accidental interruption of the mains current. The battery display (below right) flashes yellow and indicates the remaining battery life in hh:mm. Touching the field acknowledges the alarm and opens the battery menu. The user is then informed about the battery status and can return to the application after confirming via the confirm button. Additional information on the battery supply: When the remaining battery life is down to 20%, a mediumpriority alarm is triggered. This is confirmed in the same way. When the remaining battery life is down to 10%, a high-priority alarm is triggered. This alarm can only be stopped by restoring the mains power supply. Emergency mode, can be selected via: If the touchscreen fails (e.g., breakage) or the sensor bridge malfunctions, it might not be possible to control the CARDIOHELP-i and the perfusion system would have to be temporarily operated with the CARDIOHELP Emergency Drive. The Emergency Mode can be enabled to avoid manual operation. Pressing the illuminated Emergency Mode button disconnects the sensorbridge from the drive. All the interventions are now turned off, the buttons on the CARDIOHELP-i have no function, and the RPM can be set with the rotary knob. The user can determine the current RPM setting using the LED bar. Two LEDs provide further information about the mains power supply and battery status. The Emergency Mode button is covered with a protective cap and is only activated after being held depressed for a period of time. The activation is accompanied by two warning tones and a third longer tone announces the start of the Emergency Mode. From now on, the user is informed via flashing of the Emergency Mode button and a reminder tone every minute that the device is running in Emergency Mode, as shown in the simulation. Additional information on Emergency Mode : When in Emergency Mode, the CARDIOHELP-i can only be switched off by pressing the Emergency button until 9 short and one final longer tone are heard. Bubble detected, can be selected via: If a bubble is detected by the arterial flow/bubble sensor, the pump is stopped. This is accompanied by a high-priority alarm. Once the bubble has been removed, the arterial bubble sensor can be reset. The CARDIOHELP-i starts automatically with the last-set RPM flow rates. The optional venous bubble sensor would also trigger immediate Backflow Prevention. Zero flow, can be selected via: This function is usually activated together with the safety button. In the simulation it is sufficient to press the zero flow button. The zero flow mode can be activated in veno-arterial perfusion during an intervention to allow clamping of the aorta under low pressure conditions. In zero flow mode the CARDIOHELP-i selects the RPM that will stop the blood flow. This prevents arterio-venous backflow through the perfusion system. When the zero flow button is pressed, the CARDIOHELP-i automatically returns to the originally set RPM and flow rates. pven below alarm limit, can be selected via: To prevent excessive suction in the venous section of the perfusion system or on the venous vascular wall, the user can set individual intervention limits. If anything changes concerning the volume status or an occlusion arises in the venous section of the perfusion system, CARDIOHELP-i reduces the RPM rate automatically and continues to run at the set pressure limit. This is accompanied by a mediumpriority alarm. This avoids stopping perfusion completely, not to mention the associated disadvantages of stasis. In addition, if the user sets the warning limits close to the current pressure value, he can be informed early of any volume changes and implement appropriate countermeasures to avoid reducing the perfusion flow unnecessarily. MAQUET Cardiopulmonary AG Kehler Strasse 31, 76437 Rastatt, Germany, Phone: +49 (0)7222 932-0, Fax: +49 (0)7222 932-1888 5/6

Global Override, can be selected via: The Global Override can only be activated together with the safety button. It is generally used to avoid interventions and acoustic alarms during the priming procedure. It can also be used if it proves necessary to switch off all of the interventions if the sensors should malfunction. The red coloring of the Global Override button and the reminder tone every 60 seconds alert the user to the fact that the Global Override mode is activated. System locked, can be selected via: To avoid accidentally changing the set perfusion values, the interface in all thapps is automatically locked after 3 minutes. In addition, the user can lock the interface immediately by pressing the locking button. To unlock it, the user need only press the locking button for one second. If the locking button were to malfunction, it would no longer be possible to control the CARDIOHELP-i. To avoid this, a backup is included on the touchscreen making it possible to unlock the interface via two buttons. This process is demonstrated in the simulation. Additional information on System locked : The automatic lock of the control unit can only be deactivated in the thapp MECC in order to guarantee continuous unimpeded access to the perfusion values. The automatic lock is deactivated in the thapp MECC as standard when delivered. MAQUET Cardiopulmonary AG Kehler Strasse 31, 76437 Rastatt, Germany, Phone: +49 (0)7222 932-0, Fax: +49 (0)7222 932-1888 6/6