FAIRBANKS NIJHUIS PACKAGED FIRE PUMP SYSTEMS. www.fairbanksnijhuis.com



Similar documents
FAIRBANKS NIJHUIS FIRE PUMPS.

SPP Pumps Inc. Atlanta

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Fire Pump Plan Review March 2010

Para la protecció n de la vida y las propiedades, las Bombas de Incendio AC ofrece paquetizados que satisfacen cada necesidad.

TECHNICAL ADVISORY BULLETIN

Fire Protection Pumps

World-Class Fire Suppression Pumping Solutions

SECTION DIESEL-DRIVEN, FIRE PUMPS

FAIRBANKS NIJHUIS FIRE PROTECTION. FIRE PUMP SETS & PUMP PACKAGES

world class fire pumps

Design & Construction Standards, Revised January

Medical Air Systems: Scroll

Element D Services Plumbing

Pressure Limiting Driver (PLD)

Automatic Fire Sprinkler Submittal Requirements

FILLING AND PURGING THE SYSTEM

FIRE SUPPRESSION INSTALLATION CITY OF HARRISONBURG, VIRGINIA

Element D Services Plumbing

Horizontal Split Case Fire Pumpset Diesel Engine Driven

KODAK VERSAMARK, INC.

The Jockey Pump, an Important Part of a Fire Pump System.

Industrial Generator Set Accessories

NFPA31FuelOilPiping 1 Revised

FIRE FIGHTING PACKAGES

CHAPTER. Fire Pumps FIRE PUMP OVERVIEW. Fire Pump Unit Defined. Fire Pump Unit Responsibility

Section 11 - System Diagrams

Arapahoe County Residential Water Heater Installation and Inspection Guide

Section 6 - System Diagrams

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

Industrial Generator Set Accessories

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

Industrial Generator Set Accessories

Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

Industrial Generator Set Accessories

Midwest Industrial Tanks

Industrial Generator Set Accessories

Magnum Mobile Generator MMG55 Specifications

HYDROSTATIC TEST PUMPS

TECHNICAL INFORMATION Bulletin

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

NFPA 20 Update 2013 Edition. Revision Cycle. NFPA 20 Update /1/2013. Goals and Objectives

KIRLOSKAR FIRE FIGHTING PUMPS AND PACKAGES

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

OREGON FIRE CODE Interpretations and Technical Advisories

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

Industrial Generator Set Accessories

Maintaining Fire Protection Systems

ASME Packaged Indirect Fired Water Heater

C18 ACERT Fire Pump Tier bkw/ rpm

Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Oil and Coolant Circulating Heating System. Model - OCSM

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

FIVE YEAR CERTIFICATION REPORT

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Model 1210C Battery Powered Pump Shown. Description

Industrial Generator Set Accessories

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

VERTICAL TURBINE AND PROPELLER PUMPS

How To Install A Mazzei Injector

Reduced Pressure Principle Assembly 3 Valve Procedure

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Example. Fluid Power. Circuits

Industrial Generator Set Accessories

Print Shop/Mail Room

(a) Purpose. The purpose is to safeguard potable water supplies by preventing backflow into public water systems.

Section 8 Storage Tanks & Equipment

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Inspection and Testing of Water-Based Systems

Roland Garcia Pearland Fire Department

Horizontal Jet Pumps 1/3-1-1/2 HP

Axial and Mixed Flow Pumps for Large Volume Pumping

Competency Framework for Marine Engineer Class 6. Competency Framework for Marine Engineer Class 6

The following definitions apply with regard to requirements specified in this document:

FLASH TANK ECONOMIZER PRODUCT GUIDE

Transformer Deluge Systems

Winnipeg Fire Department Fire Prevention Branch

C I T Y O F S E L M A F I R E D E P A R T M E N T

New York City 2014 Building Code Fire Protection Revisions. Presented by John Bower

Quik Lining Systems Heater Owners Guide

Diesel Engine Driven Generators Page 1 of 6

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

SPRINKLER SYSTEM PLANS AND CALCULATIONS CHECK LIST

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

Manual. October 2014 FIRE SAFETY. for existing RMG buildings

Transcription:

FAIRBANKS NIJHUIS PACKAGED FIRE PUMP SYSTEMS

FAIRBANKS NIJHUIS Packaged Fire Pump Systems At the heart of our systems you ll find the Fairbanks Nijhuis pumps you ve relied on for over 90 years. Fairbanks Nijhuis offers custom and pre-engineered packaged fire pump systems. These systems are factory assembled and tested, leaving only pipe connections, power connections and structural base grouting to be completed on site. All fire pump packages built to NFPA 20 & NEC standards with UL listed/fm approved components. Fire Pump Packages Standard Equipment UL listed/fm approved Fairbanks Nijhuis fire pump UL listed/fm approved fire pump controller Fairbanks Nijhuis jockey pump UL listed jockey pump controller Pressure sensing lines complete per NFPA 20 UL Listed / FM approved OS&Y gate valves, butterfly valves and check valves Suction and discharge pressure gauges Automatic casing air release valve Casing pressure relief valve (electric packages) Hose header with valves, caps and chains Suction and discharge piping per NFPA 20 All electrical components pre-wired at factory Complete system hydrostatically tested Options Available Witnessed and non-witnessed complete system performance test Test line outlet to connect to remote tank with UL listed/fm approved flow meter, isolation valves and air release valve Test loop back to suction with UL listed/fm approved flow meter, isolation valves and air release valve Bypass loop with check valve, isolation valves and air release valve Main system pressure relief valve with enclosed waste cone Relief valve for jockey pump line Double wall fuel tank with low fuel and leak detection alarms Backflow preventor Critical grade muffler Packaged system drains piped to edge of skid Complete fire pump house Removable lifting lugs Diesel Driven Fire Pump Packages also Include Dual batteries with racks and charger UL listed fuel tank sized per NFPA 20 Residential grade muffler Flexible exhaust connector Engine cooling loop 2

Pump Features A. Fairbanks Nijhuis Fire Pump B. Motor C. Control Panel (Fire Pump) D. Test Loop E. Multi-stage Jockey Pump F. Control Panel (Jockey Pump) G. OS and Y Gate Valve H. Swing Check Valve I. Flow Meter J. Suction Pressure Gauge K. Discharge Pressure Gauge L. Coupling (Guard Not Shown) M. Relief Valve (Jockey Pump Line) N. Air Release Valve (Pump Casing) O. Relief Valve (Fire Pump) P. Air Release (Test Loop) Q. Check Valve (Jockey Pump Line) R. OS and Y Gate Valve (Jockey Pump Suction) S. OS and Y Gate Valve (Jockey Pump Discharge) T. Butterfly Valve U. Concentric Increaser V. Eccentric Reducer G V F P J D N I A K B L O U H C W T W. Butterfly Valve (Test Loop) R E M Q S 3

Pump Features Drawing Component List EFPS-1 EFPS-2 EPS-2V EFPS-3 EFPS-4 EFPS-5 EFPS-6 DFPS-1 DFPS-2 DFPS-3 DFPS-4 DFPS-5 DFPS-6 DEFPS 1 Fairbanks Nijhuis Fire Pump X X X X X X X X X X X X X X 2 Coupling (Guard not Shown) X X X X X X X X X X X X X X 3 Driver X X X X X X X X X X X X X X 4 Control Panel (Fire Pump) X X X X X X X X X X X X X X 5 Jockey Pump (JP) X X X X X X X X X X X X X X 6 Control Panel (JP) X X X X X X X X X X X X X X 7 Relief Valve (Fire Pump Casing) X X X X X X X X 8 OS and Y Gate Valve X X X X X X X X X X X X X X 9 Eccentric Reducer X X X X X X X X X X X X X X 10 Suction Pressure Gauge X X X X X X X X X X X X X X 11 Air Release Valve (Pump Casing) X X X X X X X X X X X X X X 12 Discharge Pressure Gauge X X X X X X X X X X X X X X 13 Concentric Increaser X X X X X X X X X X X X X X 14 Main Relief Valve X X X X X X X 15 Wafer Check Valve X X X X X X X X X X X X X X 16 Butterfly Valve (Discharge Side) X X X X X X X X X X X X X X 17 OS & Y Gate Valve (JP Suction) X X X X X X X X X X X X X X 18 Relief Valve (JP Line) X X X X X X X X X X X X X X 19 Check Valve (JP Line) X X X X X X X X X X X X X X 20 OS & Y Gate Valve (JP Discharge) X X X X X X X X X X X X X X 21 Enclosed Waste Cone X X X X X X X 22 Butterfly Valve (Hose Header) X X X X X X X X X X X X 23 Hose Header X X X X X X X X X X X X 24 Hose Valve X X X X X X X X X X X X 25 Fuel Tank X X X X X X X 26 Battery Racks X X X X X X X 27 Butterfly Valve (Test Loop/Line) X X X X X X 28 Flow Meter X X X X X X 29 Air Release (Test Loop/Line) X X X X 30 Butterfly Valve (Bypass Line) X X X X 31 Wafer Check Valve (Bypass Line) X X X X 32 Air Release (Bypass Line) X X X X 4

Pump Features Fairbanks Nijhuis Pump offers vertical turbine fire pump systems for static suction conditions. Vertical turbine systems come complete with pump, driver, controller, flow-measuring device, relief valve with waste cone, check valves, and pressure sensing line. 5

Vertical Turbine UL listed and FM approved NFPA-20 design Flows from 500 to 4500 GPM Pressures from 70 to 387 psi Special materials for seawater applications Diesel and electric driven Horizontal Split Case UL listed/fm approved NFPA-20 design Flows from 250 to 5000 GPM Pressures from 40 to 245 psi (40 to 190 psi at 50Hz) Diesel and electric driven Vertical Split Case UL listed and FM approved NFPA-20 design Flows from 250 to 2500 GPM Pressures from 40 to 200 psi (40 to 155 psi at 50Hz) Space-saving design Vertical In-line UL listed and FM approved NFPA-20 design Flows from 50 to 1500 GPM Pressures from 40 to 160 psi (40 to 120 psi at 50Hz) Space-saving design 6

Fire Pump Houses Designed to meet specific environmental requirements All-steel building Easy access entries Electric heaters with built-in thermostat Continuous duty exhaust fan AC motor/solenoid operated louver Interior fluorescent and flood light, exterior 70 W HPS light Sprinkler system per NFPA Finished through wall or floor penetration Mini power zone Interior wall liner Summary Each unit complete with Fairbanks Nijhuis fire pump, Fairbanks Nijhuis jockey pump, controllers and associated pressure sensing lines, valves, piping and electrical wiring. Built to NFPA 20 and NEC standards ISO 9001 Facility UL listed/fm approved components All packaged systems hydrostatically tested Packaged systems performance test available Electric or diesel driven Skid-mounted or completely housed Single source responsibility ETL third party listed 7

800 AIRPORT ROAD, 3601 FAIRBANKS AVENUE, NORTH AURORA, ILLINOIS 60542 KANSAS CITY, KANSAS 66106 HYDRAULIC 19 INSTITUTE 17 ISO 9001 REGISTERED QUALITY SYSTEM Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. FMF-02-1044 07/19/13 2013 Pentair Ltd. All Rights Reserved.