Importance of Proper Sampling and Preservative Techniques Analysis dependent upon quality of sampling procedure Eliminate contamination Poor sampling



Similar documents
GUIDELINES FOR USE BY CLASS A LICENSEES IN MEETING SNP REQUIREMENTS JULY 1996

This example of a completed sampling plan worksheet has been included to illustrate the information

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

RESIDENTIAL TREATMENT SYSTEMS

Water and Wastewater. Sample Collection and Analysis

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

APPLICATION OF ICP-MS TECHNOLOGY FOR TRACE METALS ANALYSIS

Private Water Supplies Sampling Manual. A Field Guide

Color, True and Apparent

Color, True and Apparent

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Sample Management SOP 2v8 Page 1 STANDARD OPERATING PROCEDURE NO. 2 SAMPLE MANAGEMENT REVISION LOG. Revision Number Description Date

1 Quality Assurance and Quality Control Project Plan

Application Form 2E. Facilities Which Do Not Discharge Process Wastewater

LZV585 (B) The 1-cm path is aligned with the arrow on the adapter

Introduction. The following definitions may help you better understand the components of the data report.

Suspended Solids: Unequal Results from Equal Methods

USEPA Electrode Method Method 8156

Brewery Wastewater: 2010 Water and Wastewater Conference Page 1

PERSONAL PROTECTIVE EQUIPMENT (PPE)

Saudi Aramco Project Development

Making the Most of SáOá SM Services

Best Management Practices

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

DETERGENTS. Application Recommendations. Application/ Concerns. Recommended Detergent. Articles Cleaned/ Soil Removed. Cleaning Method.

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

Environmental Technology March/April 1998

Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method)

Standard Operating Procedure for the Determination of Total and Total Dissolved Solids CCAL 13A.2

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Particularly Hazardous Substances (PHS) Standard Operating Procedure (SOP)

ESS Method 130.1: General Auto Analyzer Procedures

Standard Operating Procedure for Cleaning Nylon Filters Used for the Collection of PM 2. 5 Material

Lab PPE Guide Examples of Personal Protective Equipment

Paper Chromatography: Separation and Identification of Five Metal Cations

Chlorine, Total. DPD Method 1 Method to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information

Coating and Extraction of Honeycomb Denuders

CLEAN ROOM TRAINING CLEAN ROOM AREAS

Operator Quick Guide EC SENSOR

Microbiological Testing of the Sawyer Mini Filter. 16 December Summary

HS 1003 Part 2 HS 1003 Heavy Metals Test

Clean Laboratory Techniques

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Solids, Volatile Dissolved and Fixed Dissolved

ATTACHMENT 2. BMP Monitoring Plan Template

Enhanced Organic Precursor Removals Using Aged Filter Media Page 1. Enhanced Organic Precursor Removals Using Aged Filter Media

World-Class Oil Sampling It is Possible

Best Management Practices For Dental Office Waste

Phosphorus, Reactive (Orthophosphate)

Read all instructions carefully before completing the application. Applications must be typewritten.

4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES

Agarose Gel Electrophoresis with Food Color- Teacher Guide

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Experiment 12- Classification of Matter Experiment

BHS CANDLE FILTER APPLICATIONS FOR CLARIFICATION / RECOVERY OF SOLIDS FROM CHEMICAL SLURRIES

SPILLS & SPILL KITS. Spills -General Guidelines:

STANDARD OPERATING INSTRUCTION. Safe Handling and Removal of Asbestos Cement Pipes Procedure

NPDES Permit No. IL Notice No. AAH: ajo. Public Notice Beginning Date: April 28, Public Notice Ending Date: May 30, 2011

Improper storage of fuel on construction sites will increase the risk of water pollution that may occur as a result of leaks or spills.

SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS

Longer lifetime for hydraulic oil

Dry Ice Color Show Dry Ice Demonstrations

Guidance and Reporting Instructions on Temporary E-reporting for the MATS Rule

Best Management Practices for Mercury Waste Management in Dental Offices

ClikSTAR - Important facts about your new insulin delivery device.

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NimbleGen DNA Methylation Microarrays and Services

WASTEWATER TREATMENT OBJECTIVES

Neutralizing an Acid and a Base

HACH LANGE GmbH Willstätterstraße Düsseldorf

Standard Method for Sampling and Analysis of. of Chlorine Containing Bleaches. Soap Products

experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.

New Jersey Sludge Sampling and Analytical Guidance Document

QUALITY ASSURANCE / QUALITY CONTROL POLICY BREG SOIL AND WATER QUALITY LABORATORY UNIVERSITY OF DELAWARE

S O SSM. Services. Cat. Management Guide. Accurate Analysis Improved Cost Control Optimized Performance

Technical Cleaning Ó

Why is a Dental Amalgam. Reduction Program Being Implemented Now? PROGRAM OVERVIEW TOPICS

Introducing an All New Line of Cleaning Chemicals

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

Line to Refrigerator Ice/Water Dispenser

DMR-QA Planning Guide 2015 DMR-QA 35: Plan for Success

7. Chemical Waste Disposal Procedures

Teacher Demo: Photosynthesis and Respiration: Complementary Processes

This leaflet provides information on

THE ACTIVITY OF LACTASE

Aerated Wastewater T r eatment System

WASTE WATER TREATMENT for surface treatment applications

Transcription:

Proper Sampling and Preservative Techniques for Wastewater Analysis By: Tom Horn Industrial Fluid Management Laboratory/Project Director LICENSES, STATE OF OHIO Class II Wastewater Analyst #2-00-0202 Class II Operator, Wastewater Works #2-02-003003 Guidelines for Consideration during Sample Collection NPDES Permit Requirements Type of Sample required by Permit Tools and/or Equipment Required 1

Importance of Proper Sampling and Preservative Techniques Analysis dependent upon quality of sampling procedure Eliminate contamination Poor sampling can hinder plant improvements or upgrades Sampling Definitions Grab Samples Composite Samples Preservatives Chain of Custody Clean sampling Techniques (Low Level Mercury Analysis) EPA Method 1631 Low Limit Mercury Clean Sample Techniques (18 min. video) Method 1669 Sample Collection Clean Hands/Dirty Hands Technique Field Blanks 2

What does your Permit Require? Guidelines for Consideration During Sample Collection Types of Parameters Samples to be Grab or Composite? 24-Hour Composite or 48-Hour Composite? Tools or Equipment needed to Fulfill Requirements Correct Sampling Container Sampling Dipper Sludge Judge Composite Sampler (complete or neat) Refrigerator 3

Importance of Proper Sampling and Preservative Techniques Analysis dependent upon quality of sampling Sample only as representative as sampling techniques Avoid contamination which leads to high or low results Poor sampling has been know to hinder plant improvements. Engineers use data presented for calculations in upgrades. If inaccurate sample collection data is used, municipality may invest in something that may not work. 4

SAMPLING DEFINITIONS GRAB SAMPLE Single sample collected at a specific spot over a short period of time. These samples represent a snapshot of space and time of a sampling area. D.O., ph, temperature, residual chlorine COMPOSITE SAMPLE Sample made up of several grab samples over an allotted time, normally in timed intervals or flow proportional. p BOD-5, TSS and NH3(N) are normally collected in this manner and are excellent in determining loadings from municipal and industrial plants. 5

PRESERVATIVE Chemical or physical technique of holding a sample. Enables accuracy to be continued over extended period of time. E.g. Cool to 4ºC, H2S04, HCl, Na0H CHAIN OF CUSTODY Relative to sample handling and submission. This form documents a sample s history from collection to analysis. This document should contain sample date, time, who collected the sample and anyone who handled the sample from collection to analysis. CONTAINERS, PRESERVATIVES AND HOLDING S 6

CBOD5/BOD5 CONTAINER PRESERVATIVE HOLDING P,G COOL 4ºC 48 HOURS TOTAL SUSPENDED SOLIDS CONTAINER PRESERVATIVE HOLDING P,G do 7 days AMMONIA CONTAINER PRESERVATIVE HOLDING P,G COOL 4ºC ph<2.0 S.U.@ 4ºC 24 HOURS 28 DAYS 7

H PHOSPHOROUS CONTAINER PRESERVATIVE HOLDING P,G RINSED W/ HCl ph<2.0 H2SO4, & COOL 4ºC 28 DAYS OIL & GREASE CONTAINER PRESERVATIVE HOLDING GLASS ONLY PTFE CAP ph<2.0 (H2SO4,HCL) & COOL 4ºC 28 DAYS METALS (Cd, Cr, Cu, Ni, Pb, Zn) Total or Total Recoverable CONTAINER PRESERVATIVE HOLDING P,G do 6 MONTHS 8

Cyanide, Free or Total CONTAINER PRESERVATIVE HOLDING P, G NaOH, ph 11.0 14 days MERCURY* Method 245.1 CONTAINER PRESERVATIVE HOLDING P,G ph<2.0 (HNO3) 28 DAYS *LOW LEVEL MERCURY Method 1631 Container and preservatives to be provided by analytical laboratory Sample must be accompanied by field blank, which is laboratory mercury free water and transferred to sample container at site of sample collection 9

CHROMIUM -6 CONTAINER PRESERVATIVE HOLDING P,G COOL 4ºC 24 HOURS FECAL COLIFORM / E. coli CONTAINER PRESERVATIVE HOLDING P,G (STERILE) COOL 4ºC, Na2S2O3 (if chlorinated effluent) 6 HOURS CLEAN SAMPLING TECHNIQUES FOR METALS Method 1669 - sampling method of choice for low level mercury method 1631. Method 245.1 - Method detection level of 200ppt (0.2 ug/l) Method 1631 - Method detection level of 0.2-0.50.5 ppt 10

We have seen sampling techniques, weather conditions and other items interfere with low level mercury analysis. Items that interfere with low level mercury sampling Dental work and fillings can contaminate samples Car exhaust, industrial pollution and trains can cause contamination Rain and wind events should be considered Cigar / Cigarette smoke Rubber items like boots, gloves must be powder free nitrile BREAK! 20 minute USEPA video on low level mercury sample collection in ambient waters 11

Mercury Collection and Analysis in Ambient and Effluent Waters using EPA Method 1631 Sampling Equipment Office of Water SCC-99-004.ppt Sampling Equipment Requirements Must be non-metallic and free from materials that contains metals, as described in Method 1669 All sampling equipment and sample containers must tb be precleaned in a laboratory or cleaning facility, as described in Method 1631 Gloves, storage bags, plastic wrap may be used new without cleaning unless equipment blank results pinpoint any of these materials as a contamination source If so, then supplies must also be precleaned or obtained from different supplier Protective Clothing Protective Coveralls, Smocks or Coats (where necessary) Disposable Tyvek, or equivalent Constructed of synthetic material to prevent possible contamination of samples by mercury adsorbed onto cotton or other clothing fibers Cost: $5 to $10 each Gloves Clean, disposable, powder-free latex, vinyl or polyethylene Sleeve protectors or shoulder-length length gloves may be used by clean hands person Cost: $15 to $20 per 100 12

Sample Collection Bottles Fluoropolymer (FEP, PFA) or Borosilicate Glass 125ml to 1L Fluoropolymer or fluoropolymer-lined lined screw cap New bottles cleaned prior to use Some vendors provide certified, precleaned glass bottles with various levels of cleanliness Recommend analysis of bottle blanks on a portion of bottle lot to verify cleanliness prior to sampling Used fluoropolymer bottles can be cleaned and reused Sample Collection Bottles (cont.) Store cleaned sample bottles with 0.1% HCl May empty weak acid solution and refill sample bottle with reagent water immediately prior to transport to the field Cost: 125ml to 1L Fluoropolymer: $40 to $120 each Glass: $2 to $5 each Sample Storage and Transport Storage Bags Clean, zip-lock, nonvented, colorless polyethylene Storage Cooler Clean, non-metallic, white interior Ice or refrigerant packs 13

Fiberglas s Pole Continuous-Flow Sampling Apparatus Te flo n Tubing C-Flex Tubing Peristaltic Pump Tubing Adaptor Clamp Ring Stand Cable Ties Filter Cartridge Teflo n We ig ht Continuous-Flow Sampling Apparatus (cont.) Used for effluent and ambient water sampling Peristaltic pump AC, 12VDC or internal battery, variable speed, single pump head Cole-Parmer, portable, Masterflex L/S with Easy Load pump head, or equivalent Cost: $800 to $1500 per pump system Continuous-Flow Sampling Apparatus (cont.) Tubing Fluoroploymer (FEP) 1/4 OD x 3/16 ID, in lengths as required to reach sampling point Cost: $1 to $2 per ft C-Flex, made w/ styrene-ethylene-butylene- silicone (SEBS) resin for use in peristaltic pump head Size 25, 5/16 OD x 3/16 ID, 1ft Cost: $1 to $2 per ft 14

Continuous-Flow Sampling Apparatus (cont.) Support Stand w/ Clamp Used to support end of outlet tubing Polyethylene, fiberglass or plastic-coated coated Cost: $80 to $120 Filter (dissolved metals) 0.45 um, 15 mm diameter or larger, tortuous- path capsule filter Gelman Supor # 12175, or equivalent Cost: $20 to $25 each Boat Sampling Metal-free (e.g. fiberglass) boat, along with wooden or fiberglass oars should be used For most situations, use of existing, available boat is acceptable Flat-bottom, Boston Whaler-type boat is preferred because sampling materials can be stored with reduced chance of tipping Gasoline- or diesel-fueled boat motors should be avoided because exhaust can be source of contamination Boat Sampling (cont.) Before first use, boat should be cleaned and stored in area that minimizes exposure to dust and atmospheric particles Immediately before use, boat should be washed with water at sampling site away from any sampling points to remove any dust or dirt accumulation Samples should be collected upstream & downwind of boat movement 15

Vendors Brand names, suppliers and part numbers in Method 1669 are for illustration only and no endorsement is implied. Equivalent performance may be achieved using apparatus and materials other than those specified in Method 1631. Vendors - cont. Some vendor sources include: - Cole-Parmer - Gelman Sciences - Fisher Scientific - Lab Safety Supply - Nalgene Labware - Bel-Art Scienceware Products - VWR Scientific Products -Associated Bag Co. -I-Chem - Eagle Picher 16