AMBULATORY BLOOD PRESSURE MONITORING QUICK START GUIDE



Similar documents
ABPM 6100 Hardware Manual

Affordable ABPM and strictly guideline-based SBPM for accurate out-of-office blood pressure measurement.

24 Hour Blood Pressure Monitoring A guide to the test

Welch Allyn Office-Based Connectivity Solutions

Welch Allyn Office-Based Connectivity Solutions

Device Equivalence Evaluation Form

Upper Arm Blood Pressure Monitor SC Instructions for use

Automatic Wrist Blood Pressure Monitor with

Evaluation copy. Blood Pressure. Project PROJECT DESIGN REQUIREMENTS

AUDITVIEW USER INSTRUCTIONS

INSTRUCTION MANUAL. Ultra Premium Blood Pressure Monitor featuring ComFit TM Cuff. Model HEM-775

INSTRUCTION MANUAL. 7 series Blood Pressure Monitor with ComFit TM Cuff. Model BP760 ESPAÑOL ENGLISH

Monitoring Blood Pressure

HEART MONITOR TREADMILL 12 LEAD EKG

Installing the Webstation

INSTRUCTION MANUAL. 10 series Blood Pressure Monitor with ComFit TM Cuff. Model BP785 ESPAÑOL ENGLISH

INSTRUCTION MANUAL HEM-6052

Manual Blood Pressure Measurement

Plank 1 Tool: Hypertension Medical Assistant Training (Providence Medical Group)

INSTRUCTION MANUAL. 10 series Blood Pressure Monitor with ComFit TM Cuff. Model BP785CAN FRANÇAIS ENGLISH

INSTRUCTION MANUAL. 10 series Plus Blood Pressure Monitor with ComFit TM Cuff. Model BP791IT ESPAÑOL ENGLISH

Make your practice more efficient in a heartbeat.

Device Equivalence Evaluation Form

Installing Global Logger USB Drivers

All About Your Peripherally Inserted Central Catheter (PICC)

Name: OMRON M3 HEM-7200-E Upper Arm Blood Pressure Monitor

User's Guide DylosLogger Software Version 1.6

1. SAFETY INFORMATION

Device Equivalence Evaluation Form

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

Select Correct USB Driver

e I N S T RUC TION M ANU A L

Connex Device Integration Suite (CDIS) Network Connectivity Engine (NCE) software -

Measuring Your Blood Pressure at Home. A Review of the Research for Adults

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Running the R4 Software on a USB Port

How to measure blood pressure using digital monitors

Measurement of Blood Pressure

Welch Allyn Connex ProBP 3400 digital blood pressure device. Directions for use

Weather Direct Displays show Lost Forecast (blank boxes in the picture icons)

BODY FAT & HYDRATION % MONITOR SCALE

Connecting your Omega/BetaPAT PLUS to a PC via a USB

AUDITVIEW USER INSTRUCTIONS

Keep it Simple Timing

Configuring a Macintosh Laptop to Use Multiple Displays

Fusion. User s Guide: Updating the Fusion s Image

Targus Wireless RF Mouse USER S GUIDE. Making Your Mobile Life Easier.

User Guide. Temperature and Humidity Datalogger. Model 42280

Vasc Health Risk Manag. 2011; 7: Published online 2011 November 30. doi: /VHRM.S27193 PMCID: PMC

Installing the Gerber P2C Plotter USB Driver

Welch Allyn Vital Signs Monitor 300 Series

Circulation Stations

Project 4.2.1: Heart Rate

AcuityLink. Clinician Notifier. Software installation instructions. Software version 1.5x

USB Driver Installation for Windows XP

SNMP Web Management. User s Manual For SNMP Web Card/Box

Accurate home blood pressure measurements with the WatchBP home A. Instruction Manual

Best Practice Interface. Directions For Use & Installation Guide

MEASURING VITAL SIGNS TRAINING CHECKLIST

Questions & Answers Note: PLEASE READ BOTH MANUALS FOR DETAILED INFORMATION

Six-servo Robot Arm. DAGU Hi-Tech Electronic Co., LTD Six-servo Robot Arm

Omron Health Management Software Ver1.3 User s Help Manual

Digital Blood Pressure Monitor. Model UA-767

P R E S S U R E P O I N T S S E R I E S : Measuring your blood pressure at home

Handheld LPC Data Retrieval Software for Windows. Operation Manual

CM HOST CM CardTransporter Fuel Communication and Management Software Software version up to 3.1

OEM MAXNIBP Frequently Asked Questions

High Blood Pressure and Your Kidneys

ThunderMax TMaxI Tuner Software USB Driver Installation Guide for Windows Operating Systems v

LT1 Tune Kit Quick Start Guide

Leaf River Outdoor Products Vibrashine, Inc. P.O. Box 557 Taylorsville, MS (601) FAX (601)

Installing USB Drivers With Microsoft Windows XP

TBS Help Index / On Board Software User Manual

Content Get Started... 3 Insert SIM card and Memory Card...3 Charging the Battery or Connect to a Computer...4 PAD Overview...

3. USB DRIVER Installation of USB driver Driver for Infinity SD Data Logger. INFINITY Series Acquisition Tools Manual

Global Water Instrumentation, Inc.

CardioCard System. Product Specification and Sample Reports. PC-Based ECG CardioCard. PC-Based Stress. PC-Based Holter. CardioCard.

BMV-602 Data Link Manual

Instructions for the ACER Laptops

ScanWin Installation and Windows 7-64 bit operating system

Getting started guide 3G Turbo Stick. 3G Novatel Wireless U760 USB modem

USB3.0 Docking Station. User Manual (DA-70546)

User Manual Web Operating Panel AP User Manual. General Settings, Updating and Troubleshooting

RT-1261A Ear and Forehead Thermometer Owner s Manual

Getting Started What s included Setting up Fitbit One on a computer Mac & PC Requirements... 2

Product information and manual for SensLab BT-Adapter (Model type: BT060721) for wireless data transfer of measurement data of Lactate Scout-handheld

SoundLAB Software Download Software from the Bogen website:

UPS Monitoring and Management Software

User Installation Guide

Vmed QUICKSTART PC-DISPLAY INSTALLATION & PC-Display and Bluetooth Instructions

OARTEC SIMULATOR TRAINING MONITOR USER MANUAL Version 1.05

MED-AFEs Design Reference Manual

IMPORTANT! CPD 8424R1

HP Bluetooth Pendant Headphones User Guide

Getting to Know Xsight Home Screen and Everyday Use Settings PC Setup

Config software for D2 systems USER S MANUAL

Configuration Programme

WinLIN Setup and Operation:

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

a Centre de Médecine Cardiovasculaire, Paris, France and b Lebanese Received 7 June 2009 Revised 6 September 2009 Accepted 17 September 2009

Transcription:

C A R D I O P E R F E C T AMBULATORY BLOOD PRESSURE MONITORING QUICK START GUIDE

UNDERSTANDING ERROR CODES ERROR CODE DESCRIPTION 1 Unknown error 2 This can indicate one of the following problems: After 2 seconds the pulse has not reached the falling level Heart frequency has not reached its defined range Variation of the heart frequency is too large Less than 4 measurements were taken The rising level was not reached within 2 seconds after the falling level Pulse bandwidth is out of range Movement artefact Maximum number of beats encountered in a stage 3 This can indicate one of the following problems: The heart frequency was out of range in more than 3 pressure stages The difference between systole and diastole was too small The systole is considerably bigger than the pump pressure An oscillation value was smaller than the start or end value The pulse bandwidth is smaller than at start or end point The MAP is out of range The systole is out of range The diastole is too large The number of stages is too large The oscillation value is too large The total time is too long A function took too much time 4 The battery voltage is too low 5 No cuff was detected 6 Too many measurements were taken OR No memory was available in EEPROM 7 No measurements were taken OR The measurements were stopped NOTE: The codes listed in the table are the codes displayed by the CardioPerfect software. They are different from the error codes which can appear on the ABPM 6100 LCD display. 8 Hardware failure OR Error at zero alignment or pumping started unexpectedly SIZING CHART Correct cuff sizing is vital to the accuracy of monitoring data. Find the circumference of the patient s upper arm and refer to this cuff sizing chart for proper cuff selection. CUFF SIZE ARM CIRCUMFERENCE SOFT DISPOSABLE CUFFS ARM CIRCUMFERENCE REUSABLE SLEEVE CUFFS ARM CIRCUMFERENCE TRADITIONAL REUSABLE CUFFS Pediatric Cuff Small Adult Cuff Adult Cuff Adult Plus Cuff Large Adult Cuff Part 5082-94-3 15.8 21.3 cm Part 5082-95-3 20.0 27 cm Part 5082-96-3 25.3 34.4 cm NA Part 5082-97-3 32.0 43.4 cm NA Part 101340 18 27 cm Part 101341 25 35 cm Part 101342 33 40 cm Part 101343 39 46 cm Part 6100-10 16.0 21.8 cm Part 6100-11 21.1 26.6 cm Part 6100-12 25.4 34.3 cm Part 6100-13 27.0 42.0 cm Part 6100-14 34.3 48.2 cm

AMBULATORY BLOOD PRESSURE MONITORING QUICK START GUIDE! IMPORTANT! Make sure of the following before the patient leaves the office: The belt or shoulder strap and pouch are positioned comfortably. The Start/Stop button is accessible to the patient. (Even if the Start button is disabled in the Study Parameters, the Start/Stop button will still allow the patient to cancel a reading.) The ABPM 6100 monitor is concealed according to the patient s wishes. Remember the patient s comfort and ability to perform normal tasks can significantly impact the relevance of monitoring data. If the display is on, briefly review with the patient how to read the data. Explain to the patient the kind of information required in the Patient Diary. If the Start button is enabled, explain to the patient that he or she has the option to initiate readings using the Start/Stop button.

1 Install software This quick start guide is intended for use with CardioPerfect Workstation Version 1.6.0 or higher. For complete directions for use and warnings, please consult your user manual located on the software CD. 2 Set up monitor Install two fresh AA batteries in the back of the ABPM 6100 recorder. Connect the PC interface cable to the serial port on the back of the computer. Connect the other end to the bottom of the ABPM 6100 recorder. If you are using a USB port: Install the Keyspan USB to serial converter software first, then plug in the adapter. 3 Communicate with your monitor If you are using a USB port: Go to Start/Programs/Keyspan USB Serial Adapter. Select Keyspan Serial Assistant. Verify which COM port was assigned to adapter. Start the CardioPerfect Workstation Software: Go to File/Settings/ABPM. Select Advanced. Match proper COM port to Keyspan Serial Assistant. 4 Select Patient Open the CardioPerfect Workstation Software by double clicking on the CardioPerfect icon. To enter a new patient: 1. Click the Patient button. 2. Fill in Patient Card. To select a patient from the database: 1. In the Search box, type the patient name or number (can be a partial entry). 2. Click the Go button. 3. Click on the patient for whom you want to record the test. 5 Program your monitor Click on the ABP Icon. You will hear a few beeps followed by the New ABP Test window. Select Protocol, Referring Physician, etc. and click OK. The recorder is now programmed with the patient information and will turn itself off. Disconnect the monitor from the computer.

6 Fit your patient with the monitor and cuff Place an appropriate size cuff around the patient s nondominant arm. Position the cuff so that the Artery Marker label is directly over the brachial artery. Connect the hose of the cuff to the monitor, place the monitor in the pouch, and attach the monitor to the patient. Sleeve Cuff Traditional Cuff 7 Prepare your patient If the unit is in Sleep Mode (no display on the LCD), press the Start/Stop button to wake the unit. Press the Start/Stop button again to initiate a manual reading. This will cause the cuff to inflate and a reading to be taken. NOTE: the automatic measurements will not start until at least one manual measurement is taken Review the following instructions with your patient: Avoid excess movement during readings. Relax arm slightly away from body. Avoid hand movement. Avoid flexing muscle during reading. Do not remove cuff between readings. 8 Retrieve data When your patient returns, remove the recorder and accessories. Turn the recorder off by holding down the Start/Stop button for five seconds or until the unit beeps five times. Connect the recorder to the computer. Start the CardioPerfect Workstation Software and search for the patient in the database. Select the Read Back icon. Make your selections from the ABP Measurement Read Back window and press OK to transfer and save the data to the computer. 9 Review data and print report You can choose from multiple ABPM report templates. If automatic printing is checked in the ABPM Print settings, the report should print now. If you did not select Automatic Printing in the Settings, click on the down arrow next to the Print icon and choose Print Selected Formats to initiate printing. If you just want to print one page, click on the Print icon, and select the desired report page.

iambulatory BLOOD PRESSURE MONITORING PATIENT INFORMATION Ambulatory blood pressure monitoring (ABPM) takes numerous readings of your blood pressure over a 24-hour period or longer. It provides accurate and reliable information and can give you and your doctor a truer picture of your blood pressure than occasional visits and readings taken at your doctor s office. How often will my blood pressure be taken? Usually, your heart rate and blood pressure will be measured at 15- to 30-minute periods during the day and every 30 minutes to one hour at night. Although you may notice the first few times the cuff inflates, you will soon become used to the monitor. Most people find it very easy to wear. How does APBM work? This ABPM uses the oscillometric method, which involves measuring movement of the blood after closing off the brachial artery, the main artery that runs from the shoulder down to the elbow. The data is stored and then interpreted by trained professionals in your doctor s office. Be advised of the following: Pressing the Start/Stop button during a reading will cancel that reading and deflate the cuff regardless of whether the Start button is set to On or Off in the Study Parameters. Undress carefully at bedtime, using caution not to disconnect the hose from the monitor. Placing a pillow over the monitor during sleep will reduce any electrical hum from the ABPM 6100 unit. PATIENT DO S AND DON TS DO Wear a loose fitting blouse or shirt. Record time, symptom/mood and activity/position in the patient diary. Activate a reading (if the Start/Stop button is activated) at the first sign of symptoms. Remain motionless during readings. Keep vehicle driving and travel to a minimum. Bring diary upon return. DON T Remove the cuff. Get the monitor wet. Use power tools or heavy equipment during a reading. Remove the batteries from the unit. Wear long-sleeved sweaters or dresses during monitoring period. Swim, shower, or bathe during monitoring. Operate heavy equipment or power tools, as vibrations may functionally disrupt the monitor. 4341 State Street Road, PO Box 220, Skaneateles Falls, NY 13153-0220 USA (p) 800.535.6663 (f) 315.685.2174 www.welchallyn.com 2007 Welch Allyn REF 101913 Mat. Number: 708553, Ver: B