Model KFR56 Series Quick Response Standard Spray



Similar documents
Model F1FR Series Quick Response Glass Bulb Sprinklers

Model F156 Sprinkler Types. Model F156 Recessed Sprinkler Types. Model F142, F1XLH & F128 Sprinkler Types

Sprinkler Guards Model C Model D

Sprinkler Identification Numbers

Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Quick response concealed horizontal sidewall sprinkler

Model/Sprinkler Identification Numbers

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

TECHNICAL DATA 2. LISTINGS AND APPROVALS. Spray Nozzle 11. December 20, 2013

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

Sprinkler Identification Numbers (SINs) Technical Data

esfr pendent sprinkler vk510 (k25.2)

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

Viking Residential Sprinkler Installation Guide

Type D3 PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Antifreeze Solutions in Residential Fire Sprinkler Systems

Viking Residential Sprinkler Installation Guide

HIGH VELOCITY WATER SPRAY NOZZLE

Extended Coverage Sprinklers

IDENTIFICATION BROCHURE FOR Central COMMERCIAL WET SPRINKLERS

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Price Book - Section 20 Miscellaneous

Tyco Fire & Building Products is a leading manufacturer and distributor of water-based fire suppression systems and components, offering one of the

Installation guide Nordic mixer taps. Before installing read this guide first

TECHNICAL DATA. Dry 122a. November 12, 2013

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

TD01211 PIN: NX nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA

Universal Adjustable Fuel Pressure Regulator

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

Wet alarm valves. Wet alarm valves. FM trim

Installation Instructions

1-1/2 Inch (DN40) 9 lbs. (4,1 Kg) 8 lbs. (3,6 Kg) Flange Groove* N/A N/A. Flange Flange N/A N/A

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

Select Radiators Installation Guide

LG G5 Chassis Brace Gen 5 Camaro THE MOST POWERFUL HEADERS ON THE PLANET Brought to you by LG Motorsports

AMERICAN SOCIETY OF CERTIFIED ENGINEERING TECHNICIANS

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

Installation Instructions

NFPA 25 FAQs. 1. When inspecting an old system (60 years or older), when/where does NFPA 25 require a system to be upgraded to present standards?

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD

Easy Tool Retracting System CMC-SR2159ER36

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Below Grade Spill Containment Manholes Gallon Gallon Gallon. Installation Instructions

Installation Instructions

Engineering Specifications

Toroidal Conductivity Sensor

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

Your safety and the safety of others are very important.

A3650/11LMWS (Metal Lever) A3650/11LPWS (Porcelain Lever)

Porcelain Vessel Sink Installation

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

KODAK VERSAMARK, INC.

Approved Products for Fire Protection Piping Systems

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

Guide to good leak testing

4-600, 1000 psi. User s Guide to: Phoenix Vessel Technology Limited. End port pressure vessels Model numbers: 1386, 1384.

Technical Data. Installation

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

KEEP FOR FUTURE REFERENCE MRTALP VERTICAL LIFT BAR READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT

Diameter 3" 4" 6" 8" Flange type PN 16 PN 16 PN 16 PN 16. Orange-red ( RAL 2002) Height (cm) 27,70 26,30 28,

PGL5/6 - Parking Garage Luminaire Installation Instructions

FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING

XL PREMIUM OIL COOLER KIT

C I T Y O F S E L M A F I R E D E P A R T M E N T

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series:

BALL VALVE Installation and Operations Maintenance Manual

James M. Pleasants Company

Tech Bulletin. Hose / Cord Replacement and Required Wraps. Series RT

Grade Level Spill Containment Manholes

08.08 Vic-Check Valves

Float and Thermostatic Traps Series H, C and X

All Safe, Inc. Sherwood Master Distributor Toll Free: Fax:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

H Service Data Sheet 1 of 8

Stainless Steel Single and Dual Circulation Kits

TONNEAU INSTALLATION GUIDE

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

Installation Instructions

STORED PRESSURE STAINLESS STEEL

Transcription:

Bulletin 036 Model KFR56 Series Quick Response Standard Spray Bulletin 036 Model KFR56 Sprinkler Types Standard Upright Standard Pendent Horizontal Sidewall Model KFR56 Sprinkler Types Pendent F1/F2/FP Horizontal Sidewall F1/F2/FP Model KFR56 Concealed Sprinkler Types Concealed Pendent CCP Listing & Approvals 1. Underwriters Laboratories Inc. and Certified for Canada ()(All orientations). 2. Factory Mutual Approvals (FM) - (Pendent & Pendent at current time). UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Model KFR56 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The automatic sprinklers utilize a soldered link and have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables these sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The temperature rating of the sprinkler is identified by marking on deflector: for visual temperature identification, the 212 F soldered links are factory marked with green stripe as shown in Figure 1. Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction (AHJ). Models KFR56 sprinklers are intended for installation as specified in NFPA 13 in both light and ordinary Hazard applications. Quick response sprinklers and standard response sprinklers should not be intermixed. Upright Pendent/FP Horizontal Sidewall (HSW) Horizontal Sidewall FP (HSW) Installation Pendent Pendent/F1/F2 Horizontal Sidewall F1/F2 CCP Concealed Pendent Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard response sprinklers should not be intermixed. The Model KFR56 Quick Response Sprinklers are to be installed as shown. The Model F1, F2 & FP Escutcheons illustrated are the only recessed escutcheons to be used with the Model KFR56 Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523

Model KFR56 Sprinkler Information Table Orientation Nominal Orifice Thread Size Nominal K Factor US Metric Sprinkler Height Approvals Temperature Frame / Deflector Finish Fusible Element Color Sprinkler Identification Number (SIN) Installation Wrench Pendent NPT, FM Polyester Silver* w/ Green stripe Silver w/ Green stripe* RA3614 Model D Polyester w/ Green stripe Silver* Pendent (FP, F1 & F2) (Refer to Figures 2 & 3) NPT, FM (F1 Escutcheon only) Polyester w/ Green stripe Silver w/ Green stripe* RA3614 Model RC1 Polyester w/ Green stripe 2. Concealed (Refer to Figures 4 & 5) NPT Sprinkler 135 F / 57 C Coverplate Sprinkler Coverplate w/ Green stripe RA3614 Model RC1 Silver Upright NPT Polyester w/ Green stripe RA3624 Model D Silver w/ Green stripe Polyester w/ Green stripe Silver HSW NPT 2.63" (67mm) Polyester w/ Green stripe RA3634 Model D Silver w/ Green stripe Polyester w/ Green stripe Silver HSW (FP, F1 & F2) NPT 2.63" Polyester RA3634 Model GFR2 (Refer to Figures (67mm) w/ Green stripe 6 & 7) Silver w/ Green stripe Polyester w/ Green stripe *FM Approved version of this chrome sprinkler utilizes a white fusible element. A silver fusible element is available in Listed "only" chrome sprinkler.

Green Stripe Figure 1 When installing Model KFR56 Sprinklers, use the installation wrench specified in the information table on page 2 of this bulletin. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½ NPT sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8-24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Model KFR56/ CCP Concealed Sprinkler uses the ½ orifice, ½ NPT, 165 F (74 C) or 212 F (100 C) Model KFR56 Pendent Sprinkler with a threaded Model CCP cup which is factory attached to the sprinkler. The assembly is completed by the installation of the attractive, low profile, 135 F (57 C) or 165 F (74 C) rated Model CCP push on cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engagement. A choice of two cover plate assemblies provide either ½ (13mm) or 5 /16 (8mm) of cover adjustment. Do not install these sprinklers in ceilings which have positive pressure in the space above. After a 2 5 /8 (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model RC1 Wrench. A Teflon* based thread sealant should be applied to the sprinkler threads only. The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. *DuPont Registered Trade Mark 3. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model KFR56 Pendent Sprinkler or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Maintenance The Model KFR56 Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or nonoperation. Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate Plated Brass Black or Polyester Plated Coated Painted Special Application Finishes Sprinkler Escutcheon Cover plate Bright Brass (3) Black Plated Black Paint (2) Off (2) Satin Bright Brass Black Plated Black Paint Off Satin Bright Brass Satin Off Black Paint Black Plated (1) Other finishes and colors are available on special order. Custom paints are semi-gloss unless specified otherwise. Consult the factory for details on fusible element color and other details. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Orientation 3. Temperature Rating 4. Sprinkler Finish (See Above) 5. Link Finish: UL -, Silver FM - Only 6. Escutcheon Type (Where applicable) 7. Escutcheon Finish (where applicable) 8. Cover plate Model (Where applicable) 9. Cover plate Adjustment (Where applicable) 10. Cover plate Finish (See Above) Note: When Model KFR56 sprinklers are ordered, the sprinklers and escutcheons are packaged separately.

Model KFR56 Quick Response Pendent Sprinklers Figure 2 Figure 3 4.

Model KFR56 Quick Response Concealed Pendent Sprinklers Figure 4 Figure 5 5.

Model KFR56 Quick Response Horizontal Sidewall Sprinklers Figure 6 Figure 7 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 04/14 P/N 9999970413