Approved Products for Fire Protection Piping Systems

Size: px
Start display at page:

Download "Approved Products for Fire Protection Piping Systems"

Transcription

1 R FIRE PROTECTION PRODUCTS Approved Products for Fire Protection Piping Systems This product submittal contains approvals of the following piping products for the below-listed projects: products are Underwriter s Laboratory () Listed and/or Factory Mutual System () Approved for fire protection systems, according to the services and pressure ratings listed on the following pages. Fire protection systems (automatic sprinklers, open sprinklers, and standpipe) are Listed and/or Approved. The following charts contain the latest and information available at the time of this publication. s are subject to changes and additions by the approval bodies. Use these charts for quick reference, and consult current copies of s Fire Protection Equipment Directory or s Guide for verification. Products are Listed and Approved with standard grade E (EPDM) green color-code gaskets. FireLock products are Listed/ Approved with grade E, type A violet color-code gaskets. Grade L (silicone) orange gaskets are available for selected products, and they are Listed and Approved. recommends grade L (silicone) gaskets for FIT products in dry fire protection applications subject to temperatures below 0 F. Additionally, the Listed, grade T (nitrile) orange color-code gaskets are available. Style 31 Couplings contain grade M FlushSeal gaskets. Style 341 Vic-Flange adapters contain grade M gaskets. Always reference the latest Gasket Selection Guide for specific, gasketservice recommendations. NOTE: This publication is for submittal purposes, and it includes listings of products for fire protection services. Additional literature is available, which includes application, installation, assembly, and other information. Contact for specific recommendations and other information. JOB/OWNER CONTRACTOR ENGINEER Spec. Sect. Para. System No. Location Submitted by Date Approved Date World Headquarters P.O. Box 31, Easton, PA Kesslersville Rd., Easton, PA PICK VIC FAX: 610/

2 FireLock TM Automatic Sprinklers Qty. Product Pub. No. Sys. No. (s) STANDARD COMMERCIAL Models V2703, V2704, V2707 and V2708 Orifice K5.6 Upright, and Models V2709 and V2710 Orifice K5.6 Horizontal and Horizontal Models V2703, V2704, V2707 and V2708 High Pressure (250 PSI) K5.6 Upright, and Models V2709 and V2710 High Pressure (250 PSI) K5.6 Horizontal and Horizontal Models V3401, V3402, V3405 and V3406 Large Orifice K8.0 Upright, and Models V3409 and V3410 Large Orifice K8.0 Horizontal and STORAGE Models V3403, V3404, V3407 and V3408 Extra Large Orifice (ELO) K11.2 (Specific Application) Upright and Models V2721, V2722, V2723 and V2724 Intermediate Level Orifice K5.6 Upright and Models V3417, V3418, V3419 and V3420 Intermediate Level Large Orifice K8.0 Upright and Model K1 (AS1451) Automatic Sprinkler Brand Early Supression Fast Response (ESFR),, K14.0 EXTENDED COVERAGE Models V3411 and V3412 Extended Coverage/ Hazard (ECLH) K11.2 and Models V3413 and V3414 Extended Coverage/ Hazard (ECLH) K14.0 and Models V3415 and V3416 Extended Coverage/ Hazard (ECLH) K8.0 Horizontal and SMALL ORIFICE Models V2701, V2702, V2705 and V2706 Hazard Small Orifice K2.8 Upright, and RESIDENTIAL Models V2714 and V2716 Residential K3.0/K3.5 and Model V2718 Residential K3.5 Horizontal and Horizontal Model V2802 Residential K4.2 Flush Qty. Product Pub. No. Sys. No. (s) DECORATIVE Models V3801 and V3802 Adjustable Concealed K5.6 ACCESSORIES Models V27, V34, V38 & V38-3 Sprinkler Wrenches Spare Sprinkler Cabinets TEMPERATURE RATINGS Temperature F/ C Part Nominal Maximum Identification Temperature Rating Ambient Temp. Allowed A C E F J K M Open Glass Bulb Color Orange Red Yellow Green Blue Mauve No Bulb N Fusible Metal *Not all temperatures are available with all styles of sprinklers. Consult individual submittal sheets for specific information. SPRINKLER FINISHES Abbrev. Part Ident. Finish Abbrev. Part Ident. Finish BR 1 Plain WX 5 Wax Coated CP 2 Chrome LD 6 Lead Coated BB 3 Bright Brass WL 7 Wax/Lead Coated WH 4 White Painted CSTM 8 Custom Painted JOB/OWNER CONTRACTOR ENGINEER Spec. Sect. Para. System No. Submitted by Approved Location Date Date

3 FireLock Products Quan. Product Pub. No. Sys. No. Quan. Product Pub. No. Sys. No. FIRELOCK FIRE PROTECTION PRODUCTS Style 005 FireLock Rigid Coupling FireLock Fittings Style 006 FireLock Cap Style 744 FireLock Flange Adapter No. 10-DR Drain Elbow No. 66 Vic -End End of Run Outlet Fitting IPS CARBON STEEL GROOVED COUPLINGS & FITTINGS Style 07 Zero-Flex Rigid Couplings Style 77 Flexible Coupling Style 75 Coupling Style 741 Vic -Flange Adapter Style 743 Vic-Flange Adapter Style 750 Reducing Coupling Style 72 Outlet Coupling Style 791 Vic-Boltless Coupling Style HP-70 Rigid Coupling HP-70ES Coupling ( PSI maximum working pressure) Grooved End Fittings FIRE PROTECTION GROOVED VALVES & ACCESSORIES Series 705W Fire Protection BFV Series 705W Fire Protection BFV with Tap Series 727 FireBall Valve Series 717 FireLock Check Valve Series 717R FireLock Riser Check Valve Series 722 Threaded Ball Valve Series 751 FireLock Alarm Check Valve Series 756 FireLock Dry Check Valve Series 758 FireLock Deluge Trim Series 758 FireLock Preaction Trim IPS CARBON STEEL PRESSFIT SYSTEM Pressfit Products IPS CARBON STEEL HOLE CUT PRODUCTS Style 920 & 920N Mechanical-T Mechanical-T Cross Assemblies Style 925 Snap-Let Outlet Style 923 Vic-Let Strapless Outlet GROOVED END ACCESSORIES Style 718/719 TestMaster Style 735 Fire Pump Test Meter Style 720G/720T TestMaster II CTS COPPER TUBING GROOVED PRODUCTS Style 606 Coupling Style 641 Vic-Flange Adapter Copper Fittings FIT PIPING SYSTEM FIT Piping System Products AWWA DUCTILE IRON GROOVED PRODUCTS Style 31 Coupling Style 307 Transition Coupling Style 341 Vic-Flange Adapter AWWA (Cast) Fittings IPS HDPE PLASTIC PLAIN END Style 995 Coupling for HDPE Style 997 Transition Coupling HDPE to Steel Style 994 Flange for HDPE IPS CARBON STEEL PLAIN END Style 99 Roust-A-Bout Couplings Style 90 Plainlock Couplings Plain End Fittings CPVC PRODUCTS CPVC Products JOB/OWNER CONTRACTOR ENGINEER Spec. Sect. Para. System No. Location Submitted by Date Approved Date

4 FireLock Automatic Sprinklers Sprinkler Head Type Model No. Deflector Type Response Category Orifice Hazard, Ordinary Hazard V27 Frame K5.6 V2703 Upright Request V2707 V2707 V2704 Upright V2708 V2708 Temp. Ratings F, F, F, Available Finishes Orifice Horizontal Hazard, Ordinary Hazard V27 Frame K5.6 Request V2709 Horizontal V2709 Hor. V2710 Horizontal V2710 Hor. F, F, s, C,,, C,,, C,,, C,,, C,,, C,,, C,,, C,,, C,,, C,, Orifice High Press. (250 PSI/1725 kpa) Hazard, Ordinary Hazard V27 Frame K5.6 V2703 Upright Upright Request V2707 V2707 V2704 Upright V2708 V2708 F, F, F, A 1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4 1,2,3,4,8, C 1,2,3,4,8, C 1,2,3,4,8, C 1,2,3,4,8 1,2,3,4,8 1,2,3,4,8, C,, C,, C, Orifice - High Pres.(250 PSI/1725 kpa) - Hor. Side. - Hazard, Ordinary Hazard V27 Frame K5.6 Request V2709 Horizontal V2709 Hor. V2710 Horizontal V2710 Hor. F, F, F, J, K F, J, K Large Orifice Commercial Hazard, Ordinary Hazard, Storage V34 Frame K8.0 V3401 Upright Request V3405 V3405 V3402 Upright V3406 V3406 F, F, F, 1,2,3,4,8 1,2,3,4,8 1,2,3,4,8 1,2,3,4,8 Large Orifice Commercial Hor. Hazard, Ordinary Hazard V34 Frame K8.0 Request V3409 V3409 V3410 V3410 Horizontal Hor. Horizontal Hor., C,, C,, C,, C,, C,,, C,,, C,,, C,,, C,,, C,, F,, C, F,, C,, C,, C, TEMPERATURE RATINGS Temperature F/ C Part Identification Nominal Temperature Rating Maximum Ambient Temp. Allowed Glass Bulb Color A Orange C Red E Yellow F Green J Blue K Mauve M Open No Bulb N Fusible Metal *Not all temperatures are available with all styles of sprinklers. Consult individual submittal sheets for specific information. SPRINKLER FINISHES Abbrev. Part Ident. Finish Abbrev. Part Ident. Finish BR 1 Plain CSTM 8 Custom Painted CP 2 Chrome WX 5 Wax Coated BB 3 Bright Brass LD 6 Lead Coated WH 4 White Painted WL 7 Wax/Lead Coated AUTOMATIC SPRINKLER NOTES *Contact for wax, lead, and wax-over-lead coatings. 1 MEA Approved for V27 and V E. 2 CS for V27 and V : Approved for light hazard only. 4 Not all temperature ratings or finishes are approved or listed. Refer to current product submittals for specific information. V27 and V34 units are MEA (#62-99-E) and CS (# :112) Listed. 5 Recognized by as standard response only. 6 K3.0 for room sizes up to 16' x 16' (4,9 x 4,9 m); K3.5 for room sizes up to 18' x 18' (5,5 x 5,5 m) and 20' x 20' (6,1 x 6,1 m). 7 Horizontal K3.5 for room sizes up to 16' x 16' (4,9 x 4,9 m). 8 Cover A is rated for 135 F (57 C) for use with standard or quick response sprinklers rated 135 F and 155 F (57 C and 68 C). Cover D is rated for 165 F (74 C) for use with standard or quick response sprinklers rated 175 F and 200 F (79 C and 93 C). A proper temperature rated cover must be used with the correct sprinkler rating.

5 FireLock Automatic Sprinklers Sprinkler Head Type Model No. Deflector Type Response Category Temp. Ratings (ELO) Extra Large Orifice Storage All Hazard (Specific Appl.) V34 Frame K11.2 V3407 Request Intermediate Level Rack Storage V3403 Upright V3408 V3404 Upright V27 Frame K5.6 V2723 Upright Request V2721 Upright V2724 V2722 Upright Large Orifice Intermediate Level Rack Storage V34 Frame K8.0 V3419 Request V3417 Upright V3420 V3418 Upright Large Orifice Intermediate Level Rack Storage V34 Frame K14.0, M, M F, J, M F, J, M F J, M F J, M Available Finishes 1,5,6,7 1,5,6,7 1,6 1,6 s, C,,, C,,, C,,, C,, A 1, C, 4 1, C, 4 1, C, 4 1, C, 4 1, C, 4 1, C, 4 1, C, 4 1, C, 4 TEMPERATURE RATINGS Temperature F/ C Part Identification Nominal Temperature Rating Maximum Ambient Temp. Allowed Glass Bulb Color A Orange C Red E Yellow F Green J Blue K Mauve M Open No Bulb N Fusible Metal *Not all temperatures are available with all styles of sprinklers. Consult individual submittal sheets for specific information. SPRINKLER FINISHES Abbrev. Part Ident. Finish Abbrev. Part Ident. Finish BR 1 Plain CSTM 8 Custom Painted CP 2 Chrome WX 5 Wax Coated BB 3 Bright Brass LD 6 Lead Coated WH 4 White Painted WL 7 Wax/Lead Coated Request AS1451 C, F 1, C, 9 (ECLH) Extended Coverage Extra Large Orifice Hazard V34 Frame K11.2 V3411 Request V3411 V3412 V3412 F, M F, M A, C, E, F (ECLH) Extended Coverage Very Extra Large Orifice Hazard V34 Frame K14.0 V3413 Request V3413 1,2,3,4,8, C, 4 1,2,3,4,8, C, 4 1,2,3,4,8, C, 4 F 1,2,3,4,8, C, 4 V3414 V3414 F, M F, M A, C, E, F (ECLH) Horizontal and Horizontal V34 Frame K8.0 V3415 ECLH HSW Request V3415 ECLH HSW 1,2,3,4,8, C, 4 1,2,3,4,8, C, 4 1,2,3,4,8, C, 4 F 1,2,3,4,8, C, 4 V3416 ECLH HSW V3416 ECLH HSW A, C, E, F A, C, E, F A, C, E, F 1,2,3,4,8, C 4 1,2,3,4,8, C 4 1,2,3,4,8, C 4 F 1,2,3,4,8, C 4 AUTOMATIC SPRINKLER NOTES 1 MEA Approved for V27 and V E. 2 CS for V27 and V : Approved for light hazard only. 4 Not all temperature ratings or finishes are approved or listed. Refer to current product submittals for specific information. V27 and V34 units are MEA (#62-99-E) and CFSM (# :112) Listed. 5 Recognized by as standard response only. 6 K3.0 for room sizes up to 16' x 16' (4,9 x 4,9 m); K3.5 sizes up to 18' x 18' (5,5 x 5,5 m) and 20' x 20' (6,1 x 6,1 m). 7 Horizontal K3.5 for room sizes up to 16' x 16' (4,9 x 4,9 m). 8 Cover A is rated for 135 F (57 C) for use with standard or quick response sprinklers rated 135 F and 155 F (57 C and 68 C). Cover D is rated for 165 F (74 C) for use with standard or quick response sprinklers rated 175 F and 200 F (79 C and 93 C). A proper temperature rated cover must be used with the correct sprinkler rating. 9 Sprinkler head is manufactured by Automatic Sprinkler Fire Protection Equipment.

6 FireLock Automatic Sprinklers Sprinkler Head Type Model No. Deflector Type Response Category Temp. Ratings Available Finishes s A Small Orifice Hazard V27 Frame K2.8 V2705 F,, C V2701 Upright F,, C, V2705 F,, C V2706, C V2702 Upright Upright, C, Request V2706, C Residential V27 Frame K3.0/K3.5 Request V28 Frame K4.2 Flush Request V2714 C V2714 V2716 C V2716 V2802 Residential Horizontal V27 Frame K3.5 Request V2718 V2718 Flush Horizontal Hor. 1,2,3, 4,8, C, 6 C 1,2,3,4,8, C, 6 1,2,3, 4,8, C, 6 C 1,2,3,4,8, C, 6 N 2,4, C Decorative Concealed Ordinary Hazard V38 Frame K5.6 Request V3801 V3802 Concealed Pend. and Cover Plate Concealed Pend. and Cover Plate Replacement Cover Plate only C 1,2,3,4,8, C, 7 C 1,2,3,4,8, C, 7 C, F 2,3,4,8, C C, F 2,3,4,8, C,, 5 / A, D* (see note 8) 2,3,4,8, C,, 8 TEMPERATURE RATINGS Temperature F/ C Part Identification Nominal Temperature Rating Maximum Ambient Temp. Allowed Glass Bulb Color A Orange C Red E Yellow F Green J Blue K Mauve M Open No Bulb N Fusible Metal *Not all temperatures are available with all styles of sprinklers. Consult individual submittal sheets for specific information. SPRINKLER FINISHES Abbrev. Part Ident. Finish Abbrev. Part Ident. Finish BR 1 Plain CSTM 8 Custom Painted CP 2 Chrome WX 5 Wax Coated BB 3 Bright Brass LD 6 Lead Coated WH 4 White Painted WL 7 Wax/Lead Coated AUTOMATIC SPRINKLER NOTES *Contact for wax, lead, and wax-over-lead coatings. 1 MEA Approved for V27 and V E. 2 CS for V27 and V : Approved for light hazard only. 4 Not all temperature ratings are approved or listed. Refer to current product submittals for specific information. V27 and V34 units are MEA (#62-99-E) and CFSM (# :112) Listed. 5 Recognized by as standard response only. 6 K3.0 for room sizes up to 16' x 16' (4,9 x 4,9 m); K3.5 sizes up to 18' x 18' (5,5 x 5,5 m) and 20' x 20' (6,1 x 6,1 m). 7 Horizontal K3.5 for room sizes up to 16' x 16' (4,9 x 4,9 m). 8 Cover A is rated for 135 F (57 C) for use with standard or quick response sprinklers rated 135 F and 155 F (57 C and 68 C). Cover D is rated for 165 F (74 C) for use with standard or quick response sprinklers rated 175 F and 200 F (79 C and 93 C). A proper temperature rated cover must be used with the correct sprinkler rating.

7 FireLock Devices and Valves Wall Wall FIRELOCK ACTUATED VALVES Series 751 Alarm Check,, MEA, CS 1¹ ₂ - 6 1,5,8,10 GROOVED END VALVES Series 705W Butterfly Valve,, MEA, CS 2¹ ₂, 3, 4, 5, 6, 8, 10, 12 3,8,11,15, ,5,8,10 Request Series 756 Dry Check Request Series 705W Butterfly Valve with Tap,, MEA, CS 1¹ ₂ - 6 2,6,, MEA, CS 2¹ ₂, 3, 4, 5, 6, 8, 10, 12 3,8,11,15 Request Series 758 Deluge Trim,, MEA, CS 1¹ ₂ - 6 2,7 Request Series 727 FireBall Valve,, BSA, CS 2, 2¹ ₂, 3 4,9, ,7 Request Series 758 Preaction Trim Request Series 717 FireLock Check Valve, MEA 2¹ ₂, 3, 4, 5, 5¹ ₂, 6, 6¹ ₂, 8, 10, ,13,14,, MEA, CS 1¹ ₂ - 6 2,7 4, 5, 6, 8, 10, ,13 Request Request Series 717R FireLock Riser Valve, MEA 2¹ ₂, 3, 4, 5, 5¹ ₂, 6, 6¹ ₂, 8, 10, ,13,14 Series 722 Ball Valve (Thd.) ¹ ₂ N/A 4, 5, 6, 8, 10, ,13 ¹ ₂, ³ ₄ N/A N/A Request Request MEA Approved # E 2 MEA Approved # E 3 MEA Approved # E 4 BSA Approved # CS # :109 6 CS # :111 7 CS # :110 VALVES NOTES 8 CS # :103 9 CS # : Approved for vertical or horizontal installation. 11 Indoor/Outdoor use weatherproof operator. 12 Listed/Approved for single check and anti-water hammer service; for horizontal or vertical installation. 13 Pressure rating of Series 717R is based on the rating of Riser Check Kit when equipped for this service. 14 MEA Approved # E, Vol. 1 to CS # :113.

8 Couplings and Fittings Size Range Wall Size Range Wall FIRELOCK COUPLINGS AND FITTINGS Style 005 Rigid FireLock Coupling 1¹ ₄ - 4 3, 6, 7, 12, 16 13, 17, 30 STANDARD COUPLINGS AND FITTINGS Style 07 Zero-Flex Rigid Coupling ,6,7,11,12,13,14,15,16,17 11,12,13,14,15 12,13,14,15 12,13, Request FireLock Fittings 1¹ ₄ , 2, 3, 4, 5, 6, 7, 17, 30 Request Style 77 Flexible Coupling 1¹ ₂ ³ ₄ ³ ₄ ,2A,3,4,5,6,7,24 5,10 5,10 5,10 12,14,15 3,6,7,12,13,16,17,18, Request Style 744 FireLock Vic-Flange Adapter 2-4 1, Request Style 75 Flexible Coupling ,2A,3,4,5,6,7,10, ,6,7,11,12,13, 14,15,16,17,18 12,13, Request ¹ ₂ - 8 1¹ ₂ - 4 1,2A,3,4,5,6,7,26 5 5,10 Request Style 006 FireLock End Caps 1¹ ₄ - 4 Grooved Fittings ³ ₄ ³ ₄ ,14, ³ ₄ ,2A,5,27 Request ¹ ₄ - 4 1, 2 Request Style 741 Vic-Flange Refer to notes on the next page ,2A,5,10,21 Request Refer to notes on the next page.

9 Couplings and Fittings Wall STANDARD COUPLINGS AND FITTINGS Style 743 Vic-Flange 2¹ ₂ - 12 Wall STANDARD COUPLINGS AND FITTINGS No. 10-DR Drain Elbow 2¹ ₂ ¹ ₂ ,2A 2¹ ₂ - 6 1,2A,5 Request Style 72 Outlet Coupling 1¹ ₂ ¹ ₂ ¹ ₂ Request No. 66 Vic -End End of Run Sprinkler Outlet 2 ¹ ₂, ³ ₄, 1 2¹ ₂ ¹ ₂, ³ ₄, 1 Request Style 750 Reducing Coupling Request Style HP-70 Rigid Coupling Request Style HP-70ES With Grade E Fire-R Request Style 791 Vic-Boltless Flexible Coupling Request ¹ ₂ ¹ ₂ ¹ ₂ ,2A,5,22 5,22 2 1¹ ₂ ,13,20 2 1¹ ₂ ¹ ₂ ,2A,3,5,21,23 5,21,23 12,13,14,15 12, ,2A,5,23 5, ,13 12,13 12,13 5,10 5,10 5,10 Request ¹ ₂, ³ ₄, 1 2¹ ₂ ¹ ₂, ³ ₄, 1 1,2A COUPLINGS AND FITTINGS NOTES 1 MEA Approved # E 2 CS # :104 2A CS # :001 3 Listed and Approved at 175 on schedule 5 and Eddy Flow pipe manufactured by Bull Moose Tube Company. Listed and Approved at 175 and, respectively, on schedule 5 pipe manufactured by Wheatland Tube and IDOD Tube Companies. 4 Style 07, 75, and 77 are Approved in sizes 1-2" at. Style 005 is Approved in 2" sizes at 175 on Allied XL pipe. 5 Approved for dry pipe systems down to -40 F with standard gasket, ( recommends FlushSeal or silicone gasket with coupling Style 77, 07, 005, 75, 791 and HP-70). 6 Listed/ Approved in 2¹ ₂ and 3" sizes on American Tube Dyna-Flow pipe at for Styles 07, 75, and 77; 175 for Style Styles 07, 77, 920, and 920N are Listed and Approved in 2¹ ₂ - 4" sizes at. Style 75 3" size is Listed at and Style 75 4" size is Listed and Approved at. Style 005 is Listed and Approved in 1¹ ₄ - 4" sizes at 175 on American Tube Dyna-Flow pipe. 8 Listed and Approved in sizes 1-2" on American Tube Dyna-Flow pipe at 175. Style 925 Listed and Approved on American Tube Dyna-Flow pipe at 175 in sizes 1¹ ₄ - 2¹ ₂". 9 Listed and Approved on Allied XL and XL -II at Minimum schedule pipe to be joined: 6" or smaller/sch. 10; 8" or larger/0.188" wall. 11 accepted for -200 fire extinguishing systems. has indicated that Listed rubber gasketed fittings (couplings and fittings rated to minimum) that are not under continuous exposure to -200 and are downstream of the pressure reducing device can be utilized in -200 fixed extinguishing systems. 12 Listed for dry pipe systems down to 40 F with standard gasket ( recommends FlushSeal or silicone gasket with coupling Styles 77, 07, 005, 75, 791, and HP-70). 13 Lt. Wall shall be of the following minimum wall thickness: 1-12"/sch Listed for carbon dioxide systems, low pressure (-FYJR) for distribution piping downstream of the master valve only: S/77, ³ ₄ - 8"; S/75, 1¹ ₂ - 4"; S/07, 1¹ ₂ - 8"; S/HP-70, 2-8"; on sch. 40 pipe and standard grooved fittings ³ ₄ - 8". 15 Listed for halogenated agent systems, Halon 1301 (-GLER) extinguishing systems units, 360 for distribution piping only: S/77, ³ ₄ - 8"; S/75, 1¹ ₂ - 4"; S/07, 1¹ ₂ - 8"; S/HP-70, 2-8"; on sch. 40 pipe and standard grooved fittings ³ ₄ - 8". 16 Style 75, 07, 77 Listed on Allied XL pipe in sizes 1-3" at. Style 005 Listed Listed and Approved in sizes 1¹ ₄ - 2" on Central Sprinkler TL, C7 and Central Thread to. 18 1¹ ₄" Style 77 and Style 75 in sizes 1¹ ₂ - 6" are Listed for use on Berger Industries sch. 5 roll grooved pipe, working pressures: 1¹ ₄ - 5" and 6" Style 77 Listed on pipe in sizes 1-2" at 20 Style 07, 75, 77 in sizes 1-2"; Style 750 in 2 1", 2 1¹ ₂" sizes at and Style 005 at 175 on SL pipe. 21 Cut groove, sch. 40, 6" and smaller; sch. 30, 8" and larger. 22 Lt. wall roll grooved based on sch. 10 pipe. 23 Minimum schedule pipe to be joined; 3¹ ₂" or smaller/sch. 10; 4" or larger/0.188" wall. 24 Style 07 metric equivalent sizes 3 O.D., 4¹ ₄, 5¹ ₄, 5¹ ₂, 6¹ ₄ and 6¹ ₂" Approved to 175 on standard and lightwall pipe. (See note 10.22) 25 Style 77 metric equivalent sizes 3 O.D., 4¹ ₄, 5¹ ₄, 5¹ ₂, and 6¹ ₄" Approved to 175 (6¹ ₂" 450 ) on standard and lightwall pipe. (See note 10.22) 26 Style 75 metric equivalent sizes 4¹ ₄, 5¹ ₄, 5¹ ₂, 6 O.D., 6¹ ₄, and 6¹ ₂" Approved to on standard and lightwall pipe. (See note 10.22) 27 90, 45 elbow and tee metric equivalent sizes 3 O.D., 4¹ ₄, 5¹ ₄, 5¹ ₂, 6¹ ₄ and 6¹ ₂" Approved to 175 on standard and lightwall pipe. 6¹ ₂" No. 60 end cap Approved to 175. (See note F) 28 Style 005 metric equivalent sizes 3 O.D., 4¹ ₄, 5¹ ₄, 5¹ ₂, 6¹ ₄, 6¹ ₂ and 8" Approved to 175 on standard and lightwall pipe. (See note 10.22) 29 Listed and Approved with HP-70ES with Grade E Fire-R gaskets. 30 Listed and Approved for use on Fire-Line Flow (FLF) and Fire-Line Threadable (FLT) steel sprinkler pipe (up to 4 inches and up to ) manufactured by Western International Forest Products.

10 CPVC Products Request CPVC PRODUCTS Coupling CPVC PRODUCTS Crosses / ³ ₄ ,2 / ³ ₄ ,2 Elbows Flanges / ³ ₄ ,2 / ³ ₄ ,2 Sprinkler Head Elbow Unions / ³ ₄ ,2 / ³ ₄ ,2 Tee Reducer Bushing / ³ ₄ ,2 / 1 ³ ₄ - 2 1¹ ₂ 175 1,2 Sprinkler Head Tee Cap / ³ ₄ ,2 / ³ ₄ ,2 Reducer Coupling Female Threaded Adapters / ³ ₄ ,2 / ³ ₄ ,2 Grooved Coupling Adapter / ³ ₄ ,2 CPVC PRODUCTS NOTES 1 Please refer to the latest Installation and Maintenance (I-800) manual for cross usage with other manufacturer s CPVC products. 2 Pressure rating is based on a maximum temperature of +150 F (+66 C).

11 CPVC Products Request CPVC PRODUCTS Spigot Female Adapters CPVC PRODUCTS No. 890 One-hole Wrap Around Strap / ³ ₄ ,2 / ³ ₄ - 2 Female Sprinkler Head Adapters / ³ ₄ ¹ ₂ - 1 ³ ₄ 175 1,2 No. 891 Two-hole Strap / ³ ₄ - 2 Spigot Sprinkler Head Adapters / ³ ₄ ¹ ₂ - 1 ¹ ₂ 175 1,2 No. 892 Two-hole 90 Side Mount Strap / ³ ₄ - 2 Adjustable Sprinkler Head Adapters / ³ ₄ ¹ ₂ - 1 ¹ ₂ 175 1,2 No. 894 Surge Clip / ³ ₄ - 2 No. 893 Swivel Ring Hanger / ³ ₄ - 2 CPVC PRODUCTS NOTES 1 Please refer to the latest Installation and Maintenance (I-800) manual for cross usage with other manufacturer s CPVC products. 2 Pressure rating is based on a maximum temperature of +150 F (+66 C). No. 895 Universal Beam Clamp with Locknut / ³ ₄ - 2

12 Other Products Wall Wall HOLE CUT PRODUCTS Style 920/920N Mechanical-T Outlet 3 1¹ ₄ thru 6 2¹ ₂ & 8 2¹ ₂ 1,2,3,4.5 PRESSFIT SYSTEM Style 505 Coupling 3 1¹ ₄ thru 6 2¹ ₂ & 8 2¹ ₂ 2,3,4,5,6, C,, MEA, CS ³ ₄ - 2 1, 2 6 3, 6 4 & Request Request , 6 4, 8 3 & ,6 Style 506 Slip Coupling Style 920/920N Cross Assemblies 3 1¹ ₄ thru 6 2¹ ₂ & 8 2¹ ₂ 3 1¹ ₄ thru 6 2¹ ₂ & 8 2¹ ₂ 1,2,3,4.5 2,3,4,5,6, C,, MEA, CS ³ ₄ - 2 1, 2 6 3, 6 4 & Request Pressfit Fittings Request Style 923 Vic-Let 6 3, 6 4, 8 3 & ,6, C,, MEA, CS ³ ₄ - 2 1, ¹ ₂, ³ ₄ 10 & 12 ¹ ₂, ³ ₄ Request Request Style 925 Snap-Let Request ¹ ₄ ¹ ₂ thru 2¹ ₂ 1 1¹ ₄ ¹ ₂ thru 2¹ ₂ ,7,8, 9,10 3,6,7,8, 9.10 PRESSFIT SYSTEM NOTES All of the above products are Listed for dry pipe systems down to -40 F (-40 C). All of the above products are MEA Approved # M and CS Listed # : Listed and Approved at 175 (1205 kpa) on Schedule 5 and Eddy Flow pipe manufactured by Bull Moose Tube Company. Listed and Approved at 175 (1205 kpa) on Schedule 5 pipe manufactured by Wheatland Tube Companies. 2 Listed and Approved at 175 (1205 kpa) on Schedule 5 pipe manufactured by ID/OD System Ga1-05 for wet/dry piping systems. NOTE: does not approve the use of any other pipe on dry systems. HOLE CUT PRODUCTS NOTES 1 MEA Approved # M 2 CS # :001 3 Listed for dry pipe systems down to 40 F with standard gasket ( recommends Flush- Seal or silicone gasket with coupling Styles 77, 07, 005, 75, 791 and HP-70). 4 Styles 07, 77, 920, and 921 are Listed and Approved in 2¹ ₂ - 4" sizes at. Style 75 3" size is Listed at and Style 75 4" size is Listed and Approved at. Style 005 is Listed and Approved in 1¹ ₄ - 4" sizes at 175 on American Tube Dyna-Flow pipe. 5 Minimum schedule pipe to be joined: sch Approved for dry pipe systems down to 40 F with standard gasket, ( recommends FlushSeal or silicone gasket with coupling Style 77, 07, 005, 75, 791 and HP-70). 7 Listed and Approved at 175 on Schedule 5 pipe manufactured by Bull Moose Tube and Wheatland Tube Companies. 8 Listed and Approved in sizes 1-2" on American Tube Dyna-Flow pipe at 175. Style 925 Listed and Approved on American Tube Dyna-Flow pipe at 175 in sizes 1¹ ₄ - 2¹ ₂". 9 Listed and Approved on Wheatland Tube, Mega-Flow, Mega-, Mega-Thread, Mega- 10 and Mega-40 pipe manufactured by Weatland Tube Companies. 10 Listed and Approved on Central &, Central Thread pipe manufactured by Central Grooved Piping Products.

13 Other Products Wall Wall ACCESSORIES Style 735 Fire Pump Test Meter FIT PRODUCTS Styles 96, 961, 960, 963, 966 2¹ ₂ - 12-L 2¹ ₂ - 12-S 175 1,2, ,2,3,4,6,7,9 Request Request Style 969 Style 718 TestMaster Alarm Test Module Threaded 1¹ ₄ N/A 1,2, 1¹ ₄ 1 ¹ ₂ thru 2 1¹ ₂ ,2,3,4,6,7,9 Request Style 929 1¹ ₄ N/A 1,2 Request Style 719 TestMaster Alarm Test Module FIT 1¹ ₄ ,2 Request 13.01, 3 1¹ ₄ thru ,6,7 Style 929 Cross Request Style 720G TestMaster II Test and Drain Device 1¹ ₄ ,2,3 Request 13.01, 2 1¹ ₄ thru 2¹ ₂ 1¹ ₂ ,7 Request Style 720T TestMaster II Test and Drain Device, 1¹ ₄ - 2 3, 1-2 FIT PRODUCTS NOTES 1 Listed/ Approved for use on schedule 10 and 40 steel pipe prepared in accordance with specifications. 2 Listed/ Approved for use with Wheatland WLS, Mega Flow, Mega10, Mega 40, and Mega-Lite type pipes prepared in accordance with specifications. 3 Listed/ Approved for use with Central TL and Central Thread type pipes prepared in accordance with specifications. 4 Listed/ Approved for use with Allied Tube and Conduit SF, Super XL, Super 40, and XL type pipes prepared in accordance with specifications. 5 Listed/ Approved for use with American Tube and Co. BLT, DF, and DT type pipes prepared in accordance with specifications. 6 Listed/ Approved for use with Bull Moose Eddy-Lite and Eddy-Thread type pipes prepared in accordance with specifications. 7 MEA Approved under BSA # Listed and Approved for use on Fire-Line Flow (FLF) and Fire-Line Threadable (FLT) steel sprinkler pipe manufactured by Western International Forest Products. 9 Listed for use with Bull Moose Eddy Fast pipe in accordance with specifications. Request ACCESSORIES NOTES 1 MEA (BSA) Approved # Minimum schedule pipe to be joined; 3¹ ₂" or smaller/sch. 10; 4" or larger/0.188" wall. 3 recommends optional grade L silicone gaskets for fire protection dry systems and all systems operating below 0 F.

14 Other Products Wall (Sch. 40) Work. Press. Wall Type K & L Copper Tube PLAIN END Style 99 Roust-A-Bout Coupling GROOVED END COPPER Style 606 Copper Coupling ,2,3,4 /C 2¹ ₂ ,2,4 Request Style 90 Plainlock Coupling Request Style 641 Copper Flange ,2,3,4 /C 2¹ ₂ ,2,4 Request Plain End Fittings Request Copper Fittings /C 2¹ ₂ ,3 Request Request PLAIN END NOTES 1 MEA Approved (BSA) # SM 2 CS # :001 3 Listed for Schedule 40 steel pipe only. 4 Nuts must be tightened to published torque specifications. GROOVED END COPPER NOTES 1 MEA Approved # E 2 CS # :108 3 CS # :107 4 Roll grooving tools must be equipped only with rolls designed for grooving copper tube (color coded copper). plain end couplings are Listed for use on standard weight steel pipe (schedule 40). They are not intended for use on plastic pipe or brittle pipe, such as cast iron. Nor are they intended for use on pipe with a surface hardness greater than 150 Brinell. (Style 90 should not be used on schedule 80 or heavier pipe.) It should be noted that Style 99 Roust-A-Bout couplings can be used with No. 10P and No. 11P elbows in sizes 6" and above only. (NOTE: 90 and 45 plain end elbows from 1-5" may be used with Style 90 Plainlock couplings only. If using Style 99 Roust-A-Bout couplings, specify special fittings, with a minimum tangent length, which are required for proper assembly (contact for details). grooved end fittings must not be used with plain end couplings.

15 Underground Products Wall UNDERGROUND DUCTILE (AWWA) Style 31 Coupling UNDERGROUND HDPE PLASTIC Style 994 HDPE Flange Adapter 4-8 1,2,3 Request Style 307 Coupling Request Style 995 HDPE Coupling ,2,3 Request Style 341 Vic-Flange Adapter Request Style 997 HDPE-to-Steel Transition Coupling ,2, Request Request Fittings Request UNDERGROUND HDPE PLASTIC 1 Approved for use with the following Approved HDPE pipe: a. KWH Class 150 and 200 b. Plexco EHMW Class 150 and 200, Blue Stripe Class 150 and 200, Red Stripe Class 150 and 200 c. Driscopipe Series 1000, Class 150, and Joint rated to working pressure of pipe. 3 Approved for underground use only. UNDERGROUND DUCTILE (AWWA) 1 For joining ductile iron pipe only, in underground mains. 2 The Style 307 coupling is intended for connecting cut or roll-grooved schedule 40 or roll-grooved schedule 10 steel pipe to radius cut-grooved class 53 ductile iron pipe.

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description Style 07 Zero Flex Rigid Coupling The unique angled pad design adjusts to standard pipe tolerances to positively clamp the pipe to resist flexural and torsional loads. Working pressures are based on standard

More information

08.08 Vic-Check Valves

08.08 Vic-Check Valves The check valves are a product of computer-assisted innovative engineering with quality features including a new hydrodynamically efficient profile. The Vic-Check valve utilizes a spring-assisted, single-disc

More information

Quick response concealed horizontal sidewall sprinkler

Quick response concealed horizontal sidewall sprinkler January 1, 2011 Sprinkler 63a 1. DESCRIPTION Viking Quick Response Concealed Horizontal Sidewall Sprinkler VK408 is a small solder link and lever spray sprinkler designed for installation on concealed

More information

Based on SG GSA Fire & Security Products Contract GS-07F-0396M, Mod PO-0099 January 30, 2013

Based on SG GSA Fire & Security Products Contract GS-07F-0396M, Mod PO-0099 January 30, 2013 SimplexGrinnell TXMAS ecommerce Ferguson Fire and Fabrication Sprinkler Price List Based on SG GSA Fire & Security Products Contract GS-07F-0396M, Mod PO-0099 January 30, 2013 Product ID Description TXMAS

More information

Model KFR56 Series Quick Response Standard Spray

Model KFR56 Series Quick Response Standard Spray Bulletin 036 Model KFR56 Series Quick Response Standard Spray Bulletin 036 Model KFR56 Sprinkler Types Standard Upright Standard Pendent Horizontal Sidewall Model KFR56 Sprinkler Types Pendent F1/F2/FP

More information

Steel Fire Sprinkler Pipe

Steel Fire Sprinkler Pipe Steel Fire Sprinkler Pipe Wheatland Tube Fire Sprinkler Products Wheatland Tube began producing steel fire sprinkler pipe in 1931, and today offers the most complete line of products in the industry. Engineers

More information

Sprinkler Guards Model C Model D

Sprinkler Guards Model C Model D Bulletin 208 Rev. M Sprinkler Guards Model C Model D Bulletin 208 Rev. M Model C Sprinkler Guards Model C Series sprinkler guards are designed to be assembled onto installed sprinklers. They are constructed

More information

Copper Meter Resetters

Copper Meter Resetters Copper Meter Resetters To Set 5/8", 5/8" x 3/4", 3/4", 1", 1 1 2" & 2" Water Meters 11/12 Table of Contents Page Page Meter Resetters 5/8", 5/8" x 3/4", 3/4", & 1" Horizontal Inlet and Outlet Series 710

More information

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts. www.tyco-fire.com

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts. www.tyco-fire.com Worldwide Contacts www.tyco-fire.com Model EC-HS 80 K-factor, Quick Response Extended Coverage Horizontal Sidewall Sprinklers Installations per VdS CEA 400, Annex E, LH/OH General Description The Model

More information

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA December 19, 2013 Sprinkler 122j 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK502 is a fast response fusible element type sprinkler designed for use in storage areas

More information

Sprinkler Identification Numbers

Sprinkler Identification Numbers Worldwide Contacts www.tyco-fire.com Series TY-FRB 5.6 K-factor Horizontal Quick Response, Standard Coverage General Description described in this data sheet are quick response -standard coverage, decorative

More information

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description Worldwide Contacts www.tyco-fire.com Series 2.8,.2,.6, 8.0 K-Factor Upright, Pendent, Recessed Pendent Sprinklers Quick Response, Stard Coverage General Description The TYCO Series, 2.8,.2,.6, 8.0 K-factor,

More information

2013 Edition. Flanged fittings 30"-64" NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61

2013 Edition. Flanged fittings 30-64 NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61 30"-64" Ductile Iron industrial Applications, water & Wastewater 2 Table of Contents Flanged Fittings for Water 3 Flange Details 5 Flanged Fittings 6 90º and 45º Bend 6 22-1/2º and 11-1/4º Bends 7 Tees

More information

Model/Sprinkler Identification Numbers

Model/Sprinkler Identification Numbers Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-L 5.6 and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

More information

Pr o d u c t In f o r m at i o n V008.0

Pr o d u c t In f o r m at i o n V008.0 AGF Manufacturing Inc. Pr o d u c t In f o r m at i o n V008.0 Reliability, Versatility, Code Compatibility BK002 COLLECTa ndrain The COLLECTa ndrain family of products are anti-trip drum drips that prevent

More information

Fire Protection Systems

Fire Protection Systems VICTAULIC FIRE PROTECTION SYSTEMS G-05 UPDATED 6/2009 Fire Protection Systems G-05 UPDATED 6/2009 Innovation More than 80 years of piping systems solutions uilt into every FireLock system are innovative

More information

8D.1 BALL ANGLE METER VALVES - 3/4" & 1" P-24258 B-24258 E-24259 B-24259 B-24266 B-24267

8D.1 BALL ANGLE METER VALVES - 3/4 & 1 P-24258 B-24258 E-24259 B-24259 B-24266 B-24267 BALL ANGLE METER VALVES - 3/4" & " 8D. B-24258 MUELLER 300 Ball Angle Meter Valve MUELLER 0 Conductive Compression Connection for CTS O.D.* tubing x meter swivel nut** adding -3 suffix to catalog number.

More information

SECTION 15140 - PIPE HANGERS AND SUPPORTS

SECTION 15140 - PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

RING JOINT SYSTEMS 207

RING JOINT SYSTEMS 207 RING JOINT SYSTEMS 07 08 Table of Contents Model R-88 Pages 10-11 Model R-88 Large Diameter Page 1 Model RH-1000 1000 PSI Coupling Page 13 Model RX-3000 3000 PSI Coupling Page 1 Model RX-3770 3770 PSI

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

3, 4, 6 & 8 Model H Series Alarm Check Valve Installation and Maintenance Guide ", ", " & " Model H Series Alarm Check Valve Installation and Maintenance Guide 077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE 99-- 00-2-0 FAX 99--92 www.globesprinkler.com OCTOBER 2 C- BULLETIN A.C.V.I.M.,

More information

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description Worldwide Contacts www.tyco-fire.com Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description The TYCO Type EA-1 PROTECTO- SPRAY Directional Spray Nozzles are automatic

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description. Worldwide Contacts www.tyco-fire.com Series Multiple Jet Controls DN20, DN25, DN40, and DN50, 2 bar BSPT Inlet & Outlets Threads General Description The TYCO Series Multiple Jet Controls are control valves

More information

Model F1FR Series Quick Response Glass Bulb Sprinklers

Model F1FR Series Quick Response Glass Bulb Sprinklers Model F1FR56 Sprinkler Types Standard Spray Standard Spray Conventional / Vertical Sidewall Model F1FR56 Recessed Sprinkler Types Standard Spray Model F1FR56 Concealed Sprinkler Types Standard Spray Model

More information

Extended Coverage Sprinklers

Extended Coverage Sprinklers Extended Coverage Sprinklers Welcome ASPE Wally Barker Sprinkler Systems 101 MATERIALS OF CONSTRUCTION The components that make up a sprinkler head are: Frame or casting Deflector Fusible element or frangible

More information

Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General Description

Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General Description Worldwide Contacts www.tyco-fire.com Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall s Quick and Standard Response (Light Hazard) General Description TYCO Series TY-FRB 5.6 and

More information

HDPE Pipe Joining System

HDPE Pipe Joining System HDPE Pipe Joining System The System The fast, easy, and economical way to mechanically join HDPE pipe. Fast, easy bolted connection Faster installation Easy to remove and rotate pipe for increased pipe

More information

Price Book - Section 20 Miscellaneous

Price Book - Section 20 Miscellaneous Effective Date Price Book - Central - 4" Dry Pipe Valve Model AF or AG (2002) (each) Valve Cover 40002000 $564.50 Cover Bolts (Purchase 6 Units Each) 60003000 $15.50 Cover Gasket 40004000 $139.00 Clapper

More information

Sprinkler Identification Numbers (SINs) Technical Data

Sprinkler Identification Numbers (SINs) Technical Data Worldwide Contacts www.tyco-fire.com Series DS-1 5.6 K-factor, Dry-type Sprinklers Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General Description TYCO Series DS-1 5.6K

More information

08.09. Triple Service Valve Assembly

08.09. Triple Service Valve Assembly SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic Tri-Service valve is an assembly (shipped as individual components) of a standard Victaulic butterfly or Vic-Plug valve and a check valve. This combination

More information

IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS

IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS 1 INTRODUCTION TO THE VOLUNTARY REPLACEMENT PROGRAM This brochure provides information that will assist you in identifying whether the sprinklers

More information

Model F156 Sprinkler Types. Model F156 Recessed Sprinkler Types. Model F142, F1XLH & F128 Sprinkler Types

Model F156 Sprinkler Types. Model F156 Recessed Sprinkler Types. Model F142, F1XLH & F128 Sprinkler Types Bulletin 013 Rev. M Models F1 Series Standard Response s Bulletin 013 Rev. M Model F156 Types Standard Upright Standard Pendent Conventional Vertical Sidewall Model F156 Recessed Types Pendent/F1/F2/FP

More information

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES CONTINENTAL INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today

More information

SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS

SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS PART 1: GENERAL 1.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of AW facilities. Closely coordinate construction work

More information

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description Worldwide Contacts www.tyco-fire.com Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description TYCO Series DS-1 Dry-Type Sprinklers, 5.6

More information

SECTION 15105 DUCTILE IRON PIPE AND FITTINGS

SECTION 15105 DUCTILE IRON PIPE AND FITTINGS SECTION 15105 DUCTILE IRON PIPE AND FITTINGS PART 1 GENERAL.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of Owner facilities. Closely coordinate construction work and connections

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

FIVE YEAR CERTIFICATION REPORT

FIVE YEAR CERTIFICATION REPORT GARDEN GROVE FIRE DEPARTMENT FIRE PREVENTION DIVISION FIVE YEAR CERTIFICATION REPORT Service and maintenance report of automatic fire extinguishing systems, including fire sprinklers, dry, deluge, and

More information

esfr pendent sprinkler vk510 (k25.2)

esfr pendent sprinkler vk510 (k25.2) January 17, 2014 Sprinkler 124a 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Pendent Sprinkler VK510 incorporates the capability to suppress specific high-challenge fires. The addition

More information

Viking Residential Sprinkler Installation Guide

Viking Residential Sprinkler Installation Guide Viking Residential Sprinkler Installation Guide January, 2009 Trusted Above AllT M www.flowbusiness.cl Sprinkler RES1 January 9, 2009 1. DESCRIPTION Viking residential automatic sprinklers are equipped

More information

SECTION 33 12 19 FIRE HYDRANTS

SECTION 33 12 19 FIRE HYDRANTS SECTION 33 12 19 FIRE HYDRANTS PART 1: GENERAL 1.01 SCOPE A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33 00 - Submittals.

More information

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING 60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed

More information

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS FIRE DEPARTMENT Bureau of Fire Protection and Life Safety www.cityofsanmateo.org 1900 O Farrell, Suite 140 San Mateo, CA 94403-1332 (650) 522-7940 FAX: (650) 522-7941 TDD: (650) 522-7047 MAINTENANCE AND

More information

Wet alarm valves. Wet alarm valves. FM trim

Wet alarm valves. Wet alarm valves. FM trim Description Usually, a wet alarm valve station comprise: - a Rolland wet alarm valve linked to the water motor gong. - a set of valves and by pass used to test the system. - a drain valve. - a test valve

More information

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed

More information

Mechanical Products. Mechanical Products M06-1

Mechanical Products. Mechanical Products M06-1 Products Products M06-1 3 TABLE OF CONTENTS 1. GENERAL DATA... 5 10 The Engineered Coupling...6 Features & Benefits...7 ISO 9001:2000 Certificate of Registration...8 Approvals...9 Manufacturing Process...10

More information

EFSN Training i Module 1. 90 Minutes

EFSN Training i Module 1. 90 Minutes Introduction to Sprinklers EFSN Training i Module 1 90 Minutes Topics How sprinklers work Performance of sprinkler systems Types of Sprinkler Introduction to sprinkler systems Introduction ti to sprinkler

More information

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves 1. General company and product information 2. Flanged gate valves for water 3. Other gate valves for water 4. Combi valves 5. Service connection valves for water 6. Valves and fittings for gas 7. Fire

More information

Model SW-20 and SW-24 11.2 K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Model SW-20 and SW-24 11.2 K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description Worldwide Contacts www.tyco-fire.com Model SW-20 and SW-24 11.2 K-factor Extended Ordinary Hazard Horizontal Sidewall s (Standard ) General Description 11.2 K-factor, Extended Ordinary s, Standard are

More information

TECHNICAL DATA 2. LISTINGS AND APPROVALS. Spray Nozzle 11. December 20, 2013

TECHNICAL DATA 2. LISTINGS AND APPROVALS. Spray Nozzle 11. December 20, 2013 Spray Nozzle 11 1. DESCRIPTION Viking Model C-1 Window Sprinklers are non-automatic, open, outside intended for protection of windows, walls, and roofs against exposure fires. The directional discharge

More information

Technical Data. Installation

Technical Data. Installation Technical Services: Tel: (800) 81-91 / Fax: (800) 791-5500 Model 51 (1) Riser Manifold 1-1/ thru 6 Inch (DN40 thru DN150) For NFPA 1 Sprinkler Systems General Description The Figure 51 (1) Riser Manifolds

More information

Transport & Automotive CATALOGUE. March 2011. Customer Service Phone: 1800 777 299 Fax: 1800 065 321 Email:[email protected]. www.tubefit.com.

Transport & Automotive CATALOGUE. March 2011. Customer Service Phone: 1800 777 299 Fax: 1800 065 321 Email:sales@tubefit.com.au. www.tubefit.com. Transport & Automotive CATALOGUE Customer Service Phone: 1800 777 299 Fax: 1800 065 321 Email:[email protected] March 2011 www.tubefit.com.au Page 1 4 6 9 12 14 16 17 19 20 22 23 24 26 28 29 31 33 Index

More information

Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.

Double-Headed Screw 1. 3/4 FIP x 3/4 MIP x 1/4 hole 2. 3/4 Fip x 3/4 MIP. Feed Water Connector 1. 1/2 FIP x 1/2 MIP x 1/4 OD 2. 3. Picture Item No. Description RO- 0010 Brass Water Feed 1. 3/4" FIP with 1/4" hole 2. Using on R.O. tank RO- O020 Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP RO- 0030 Brass

More information

Section 3510: Reclaimed water Pipes, Valves, and Appurtenances February 11, 2011

Section 3510: Reclaimed water Pipes, Valves, and Appurtenances February 11, 2011 STANDARDS AND CONSTRUCTION MANUAL : Reclaimed water Pipes, Valves, and Appurtenances February 11, 2011 PART 1 - GENERAL 1.01 SCOPE OF WORK A. These specifications cover the pipes, fittings, and appurtenances

More information

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description Worldwide Contacts www.tyco-fire.com Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description The TYCO Model WS Specific Application Window

More information

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water 105 Decker Court, Suite 825, Irving, TX 75062 P: 469-499-1044 F: 469-499-1063 www.plasticpipe.org HDPE

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.

ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16. ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.4-1998 - Cast Iron Threaded Fittings ASME/ANSI B16.5-1996 - Pipe

More information

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description The TYCO RAPID

More information

Fixtures - Parts - Accessories to shampoo bowls

Fixtures - Parts - Accessories to shampoo bowls Page 1??? - For what brand of bowl do you need parts??? Find out by looking on the bottom of the bowl, between the front and strainer, where molded in the bottom is the brand and model number. For example,

More information

Hose Clamps & Fittings

Hose Clamps & Fittings All Stainless Steel Marine or Underground Hose Clamps 5/16 HEX HEAD SCREW 60000 SERIES Highly corrosion resistant Use for marine or underground applications Stainless Steel Band, Housing Plated Steel Screw

More information

FULL FACE FLANGE-TYTE Gasket FOR FLANGED JOINTS

FULL FACE FLANGE-TYTE Gasket FOR FLANGED JOINTS 4"-64" FULL FACE FLANGE-TYTE Gasket FOR FLANGED JOINTS NSF FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS NSF P 2 Table of Contents Introduction 3 Pressure Performance 3 Torque Performance

More information

American- Darling 5¼" B-84-B-5.

American- Darling 5¼ B-84-B-5. -5 Sealed Lubrication Chamber Seals operating threads from water and debris which greatly reduces routine maintenance. Top Travel Stop Nut Helps prevent stem buckling and damage to bronze components which

More information

Diameter 3" 4" 6" 8" Flange type PN 16 PN 16 PN 16 PN 16. Orange-red ( RAL 2002) Height (cm) 27,70 26,30 28,70 29.70

Diameter 3 4 6 8 Flange type PN 16 PN 16 PN 16 PN 16. Orange-red ( RAL 2002) Height (cm) 27,70 26,30 28,70 29.70 Description Usually, a wet alarm valve station comprise: a Rolland wet alarm valve linked to the water motor gong. a set of valves and by pass used to test the system. a drain valve. a test valve gauges

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for

More information

IDENTIFICATION BROCHURE FOR Central COMMERCIAL WET SPRINKLERS

IDENTIFICATION BROCHURE FOR Central COMMERCIAL WET SPRINKLERS IDENTIFICATION BROCHURE FOR Central COMMERCIAL WET SPRINKLERS 1 INTRODUCTION TO THE VOLUNTARY REPLACEMENT PROGRAM This brochure provides information that will assist you in identifying whether the sprinklers

More information

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description IMPORTANT Always refer

More information

How To Replace A Reverse Osmosis Water Tank

How To Replace A Reverse Osmosis Water Tank ALL MODELS REVERSE OSMOSIS WITH NONAIRGAP FAUCET 1. Read all instructions carefully before starting installation. 2. Find the cold water line beneath your sink. The cold water is typically on the right.

More information

DRESSER TM PIPELINE SOLUTIONS

DRESSER TM PIPELINE SOLUTIONS Wal-Rich Corporation is a master distributor of Dresser Pipeline Solutions, a trademark of GE. The following pages highlight the items that are in stock at our NY facility. For more information, please

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...

More information

G2 Optima Plus Flushometer

G2 Optima Plus Flushometer G2 Optima Plus Flushometer SENSOR MODULE COMPONENT PARTS 1 3 4 5 6 7 2 13 12 11 Item No. Code No. Part No. Description 1. 0325160 EBV-138-A G2 Cover/Ring/Sensor Assembly Water Closet 0325161 EBV-139-A

More information

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED. CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT

More information

Ford Pipe Repair Products The Ford Meter Box Company, Inc.

Ford Pipe Repair Products The Ford Meter Box Company, Inc. Section L 7/2008 Ford Pipe Repair Products The Ford Meter Box Company, Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260-563-3171 FAX: 800-826-3487 Overseas FAX:

More information

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

WATER & SEWER CORROSIVE RESISTANT PRODUCTS WATER & SEWER CORROSIVE RESISTANT PRODUCTS The Standard of Excellence in the Industry CASING SPACERS COUPLINGS & FLANGE COUPLING ADAPTERS REPAIR CLAMPS DUCTILE IRON SADDLES STAINLESS STEEL SADDLES TAPPING

More information

PLUMBING VALVES HOUSTON ORLANDO GREENVILLE 800/392-5066 800/327-3022 800/476-2212 TOTAL MAINTENANCE SOLUTIONS

PLUMBING VALVES HOUSTON ORLANDO GREENVILLE 800/392-5066 800/327-3022 800/476-2212 TOTAL MAINTENANCE SOLUTIONS 8-1 BRONZE GATE VALVES 125 psi. SWP 200 psi WOG Threaded ends Non-rising stem Solid wedge disc DOMESTIC IMPORT PART # 40300250 1/4 40300260 40300251 3/8 40300261 40300252 1/2 40300262 40300206 3/4 40300263

More information

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D. CONDENSED CATALOG PVC HPB-0-A Effective 9//97 Revised //99 CLEAR / / / / -/ -/ -/ x/ CLEAR / / / / -/ PVC SDR. PSI (Water @ 7. F.) /.0.9.0.0 PVC SDR -/ -/ -/ 0 0 PVC SCHEDULE 0.0.7.0.00..7.7.00.000.00...

More information

Watts Pure Water Systems

Watts Pure Water Systems Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION THOMAS - G-FLEX GFLEX TECH SPEC CONNECTING INNOVATION JOHANNESBURG TEL: +27 11 794 7594 CAPE TOWN TEL: +27 21 556 5258 POLOKWANE TEL: 015 298 9142 DESIGNER, MANUFACTURER AND DISTRIBUTOR OF PIPE CONNECTION,

More information

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials

More information

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source. Mueller Pipe Repair Products Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source. SERVICE SADDLES Mueller service saddles, available in bronze,

More information

AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids

AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids The AMERICAN Mechanical Joint was developed by the American Cast Iron Pipe Company and first marketed in 1929. Since that time, millions

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information

REFER TO SPECIFICATIONS AND STANDARD PLANS FOR DETAILED WATER METER, METER VAULT, AND SERVICE LINE REQUIREMENTS

REFER TO SPECIFICATIONS AND STANDARD PLANS FOR DETAILED WATER METER, METER VAULT, AND SERVICE LINE REQUIREMENTS GENERAL REQUIREMENTS METER, METER VAULT, AND SERVICE LINE REFER TO SPECIFICATIONS AND STANDARD PLANS FOR DETAILED METER, METER VAULT, AND SERVICE LINE REQUIREMENTS METER & METER VAULT: 1. METER AND RADIOREAD

More information

Clark County Fire Prevention

Clark County Fire Prevention Clark County Fire Prevention Mission Statement: To provide the highest level of fire protection and related services TITLE: REQUIREMENTS FOR A NEW SPRINKLER SYSTEM IN ACCORDANCE WITH THE 2002 EDITION OF

More information

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

TD01211 PIN: NX010 201007.2 nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA

TD01211 PIN: NX010 201007.2 nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA Water Motor Alarm MODEL: NX010 GENERAL DESCRIPTION TECHNICAL SPECIFICATIONS Model NX010 Working Water Pressure Range 5 to 175 psig 0.035 to 1.2 MPa (0.35 to 12 bar) Shipping Weight 11 lbs 5 kg Alarm Line

More information

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose: PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination

More information

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.

More information

1-1/2 Inch (DN40) 9 lbs. (4,1 Kg) 8 lbs. (3,6 Kg) Flange Groove* N/A N/A. Flange Flange N/A N/A

1-1/2 Inch (DN40) 9 lbs. (4,1 Kg) 8 lbs. (3,6 Kg) Flange Groove* N/A N/A. Flange Flange N/A N/A Worldwide Contacts www.tyco-fire.com DV-5 Deluge Valve Diaphragm Style General Description The TYCO 1-1/2 thru inch (DN40 thru DN200), DV-5 Deluge Valves are diaphragm type valves designed for vertical

More information

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code Part 1 - GENERAL 1.1 DESCRIPTION OF WORK A. Design and installation of an engineered Kidde ECS Advanced Delivery Systems (ADS), clean agent/waterless fire suppression system employing DuPont FM-200 agent,

More information

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-FRL 5.6 and 8.0 K-factor Extended Horizontal Sidewall s Quick & Standard (Light Hazard) General Description The Series TY-FRL, 5.6,

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

RMF Engineering 23 05 23

RMF Engineering 23 05 23 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information

Preaction System with DV-5 Deluge Valve Single Interlock, Supervised Wet Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200) General Description

Preaction System with DV-5 Deluge Valve Single Interlock, Supervised Wet Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200) General Description Worldwide Contacts www.tycofire.com Preaction System with DV5 Deluge Valve Single Interlock, Supervised Wet Pilot Actuation /2 thru 8 Inch (DN thru DN200) General Description The DV5 Supervised Single

More information