National System of Garage Ventilation s Engineering Guide



Similar documents
Design Information. Designing Your Dust Collection System. Typical dust or fume collection system

FIRE DAMPER APPLICATION GUIDE

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

Fan Applications & System Guide

Uni-Quick Duct System. Moveable. Uni-Quick. Duct System. DUST COLLECTION and MATERIAL HANDLING APPLICATIONS a McGill AirFlow product

Basic Selection & Proper Application of Overhead Air Distribution Devices

CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB

SUMMARY of PRODUCTS. HVAC Systems Control Airflow, Space, & Building Pressurization. Accurate airflow measurement for demanding applications

Cooktop Low-Profile Ventilation Hoods

F-900 HOPEC Bench Hood Framed Vertical Sash

1.2 Refrigerant Equipment. General

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

Cooling Capacity CFM in. w.c. (125 Pa)

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

CE6500 Energy Recovery Ventilator

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Suction assembly for l IBC and 205 l drums mm suction tube Suction assembly for tanks mm suction tube.

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

SECTION FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

ENHANCED LABORATORY HVAC SYSTEM

NAVIEN AMERICA INC FITCH AVENUE

Downflo workstation DuSt ColleCtorS

How To Order A Direct Flow Air Cleaner

Chapter 12 Industrial Ventilation

VW Caddy W INSTALLATION INSTRUCTIONS

Ventilation Solutions Kitchens. fantech

VAV Laboratory Room Airflow The Lowdown on Turndown

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDS1 Swing Gate Valve. by AMOT. Overview. Typical Applications. Key Features and Benefits

Midwest Industrial Tanks

POWERS Controls No. 4 Pneumatic Damper Actuator

UniMax Large Floor Mount (Walk-In) Fume Hoods

ENGINEERING DATA. Fan Performance Troubleshooting Guide

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

TELESCOPE Motorized Lighting Suspension

Chapter 3.5: Fans and Blowers

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Centrifugal Fans and Pumps are sized to meet the maximum

We will discuss common industrial applications with guides for the proper use of electric motors on these.

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

OSHA and Welding Exhaust

Element D Services Heating, Ventilating, and Air Conditioning

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

How To Launch A Rocket From A Formica

Heavy-Duty Lube and Fuel Truck Sales Tool

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

Duct Design. Presented by Dave Janquart

300 Series PA Pump and Cooler Assemblies

SAM HOUSTON STATE UNIVERSITY

Morrison Bros. Co. General Product Specifications

HP IN-LINE BILLET FUEL PUMPS

FAIRFIELD INDUSTRIES INC.

Exhaust Calculation Booklet

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Element D Services Plumbing

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

CITYPLEX TOWERS BOILER INSTALLATION ORU RFP-1138

RFQ # PR Replace Kitchen Equipment in the CGR

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

Commercial Gas Furnace Upflow

The CLIPPER Solutions

ROOF TOP MOUNTED Air Handler Specification

product application guide

DRYER VENTING SPECIFICATIONS DRYER SAFETY

NFPA Combustible Dust Compliance and the Industrial Ventilation System

Industrial Ventilation Design Guidebook Chapter 10 LOCAL VENTILATION

Test Code: 8297 / Version 1

SUZUKI GSX-R 600 (2008)

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

SIZING AND CAPACITIES OF GAS PIPING

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION MORTUARY REFRIGERATORS

*Note: This document is an electronic (scanned) version of the original paper report and formatting may vary somewhat from the original.

Cooling Capacity CFM in. w.c. (125 Pa)

Commercial Air is the smart choice for top air conditioning performance and the best value for money system around.

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

UPBLAST & HOODED PROPELLER ROOF VENTILATORS

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

ASX7-4-IOM-7 J

Design of Closed-loop Fumigation Systems for Grain Storage Structures

Range Equipment HVAC Design & Supply Modular Ranges

The Silencer. Silencer Outdoor Air Blower, The Name That Says It All. Quality Product. Call for more information

SECTION PIPE HANGERS AND SUPPORTS

For extraction technology and occupational health & safety

WELCOME TO PATTERSON FAN CO. Shipping Docks HVLS Ceiling and High Velocity Fans - Ideal for Fulfillment/Distribution Centers

Compliant Healthcare Technologies, LLC. NFPA 99, 2012 Changes" November 13, 2013!

Transcription:

National System of Garage Ventilation s Engineering Guide In designing a fume removal system, it is extremely important to determine the following: 1. Type of apparatus to be exhausted (i.e. gasoline, propane, diesel, etc.) 2. Maximum horsepower of apparatus 3. Condition of apparatus (i.e. tune-up/idle, pump testing, full-load dyno, etc.) 4. Exhaust tailpipe size, shape, & location 5. Type of system desired (i.e. underfloor or overhead) After securing the above information, it is helpful to fill out the National System of Garage Ventilation Specification Planner. This planner is designed to assist in designing the at-the-source exhaust removal system. When determining where the system will be located, consideration must be made as to ease of use for the mechanic. USER FRIENDLY MEANS MORE EFFECTIVE, CONSISTENT USE. National s tailpipe adapters are designed to be larger than the apparatus tailpipes to allow ambient air to be introduced into the system. The ambient air mixes with the exhaust fume for cooling and dilution to eliminate the possibility of direct exhaust being emitted from the exhaust blower. The following is a selection guide for CFM, flexible tube diameter, & recommended tube type based on horsepower and conditions. Underfloor and overhead ductwork must be graduated to create a balanced system while maintaining a velocity between 2,500 & 4,500 fpm. NOTE: The below table is for Normally Aspirated vehicles. Engine Horsepower Idle Tube Ø Tube Type Dynmometer Tube Ø Tube Type Gasoline < 150 150 cfm 3 RW, NK 350 cfm 4 XT, NS, BB Gasoline 300<hp>150 300 cfm 4 RW, NK 600 cfm 6 XT, NS, BB Gasoline > 300 500 cfm 5 XT, NS 1000 cfm 8 BB, HT Diesel < 150 300 4 RW, NK 600 cfm 6 XT, NS, BB Diesel 300<hp>150 600 6 XT, NS, BB 1200 cfm 8 HT Diesel > 300 1000 8 XT, NS, BB Consult factory NOTE: CONSULT FACTORY FOR EXTENDED FULL LOAD DYNOMOMETER The flexible tubing is also determined by the type of system being utilized (overhead, underfloor, hose reel, etc.). Each system specification in this National System of Garage Ventilation product catalog lists which flexible tubing is recommended for that particular system. I

Once you have determined the diameter and type of flexible tubing, you need to determine what type of system best fits your needs. National Systems has two basic types of at-the-source exhaust removal systems; overhead and underfloor. UNDERFLOOR Underfloor systems are an excellent choice for new facilities, since the entire system is built into the floor. Existing facilities can also modify their floors for installation of an underfloor system. Underfloor systems are virtually maintenance free once they are installed. There are three types of underfloor systems; cast aluminum self-close (RY), constructed self-close 1/4 plate lit (CGY, CSY, or SSY), and the cast aluminum plugin (PY or TS-30). The RY, CGY, CSY, and SSY underfloor inlets are designed to store the flexible tubing assembly under the floor. The PY and TS-30 inlets are designed to store the flexible tubing assembly in another location (i.e. wall bracket). The RY inlet consists of a cast aluminum body, cast aluminum lid, shear pin, galvanized saddle, and galvanized adjusting sleeve. The RY inlet can accommodate either 3 or 4 diameter flexible tube assemblies. The RY inlet also comes in a dual configuration. The CGY inlet consists of an angle-iron frame, 1/4 plate lid, galvanized steel body, galvanized steel saddle, and galvanized steel adjusting sleeve. The CGY inlet can accommodate 4, 5, or 6 diameter flexible tube assemblies. The CSY inlet is constructed the same as the CGY with the exception that the saddle, body and adjusting sleeve are stainless steel. The SSY inlet is constructed the same as the CSY with the exception that the angle-iron frame and 1/4 plate lid are stainless steel. The CGY, CSY, or SSY inlet also comes in a dual configuration. The PY and TS-30 inlets consist of a cast aluminum body, cast aluminum lid, galvanized saddle, and galvanized adjusting sleeve. The PY inlet accepts either 5 or 6 diameter flexible tube. The TS-30 inlet accepts either 3 or 4 diameter flexible tube. OVERHEAD Overhead systems are the best choice for an existing facility. National Systems offers five basic types; F- Systems, hose reels, Tele-Flex, boom arms & EVE systems. The F-System is designed to store the flexible tube assembly as close to the ceiling as possible. The system consists of 3 to 8 diameter flexible tube, tailpipe adapter, lifting elbow, blastgate, clamps, & a pull-up assembly w/ pulleys. A spring return balancer or winch assembly can be substituted for the standard pull-up. II

Hose Reels are designed to store the flexible tube on a reel drum. We offer two types of reels; spring operated and motorized. The reels can accommodate 3 to 8 diameter flexible tube. The reels can be used with (RW, XT-65, NS, BB or HT) flexible tube. The reels can store up to 42-0 of 4, 34-0 of 5, 28-0 of 6, or 25-0 of 8 diameter flexible tube. Tele-flex units are designed for gasoline vehicles. The tele-flex inlets are an economical solution when a wall is not accessible. The flexible tube tele-scopes within itself to give the mechanic a total of 17-0 reach when fully extended and 6-6 in the stored position. We offer two sizes TF-543 and TF654. The Boom Arms are designed to give the mechanic the ability to move the arm out of the way of obstructions and cover a much wider work area. National s boom arms can accessorized to fit with hose reels, F-systems, or weld arms and comes in sizes from 5-0 to 20-0. The EVE emergency vehicle exhaust system is designed to automatically release from the emergency vehicle. The system controls the blower and release from the apparatus. It consists of a pneumatic adapter, safety-disconnect, manual inflate valve, safety boot, lifting elbow, manual deflate valve, balancer, track, trolley regulator valve, and auto-start system. After you have determined what type of system you require and the general location of the drops, it is time to size the blower. First you need to know the total cfm requirements of the system. You can do this by adding up the cfm needed for each inlet. Next you need to determine the total static pressure in the system. Total static pressure is determined by first locating the furthest drop from the blower and calculating the static pressure in that drop. See chart below for general static pressure calculations. Once you have calculated the static pressure for the furthest drop you then have to calculate the static pressure in the ductwork back to the blower. Be aware that you must add the cfm to the duct when you pass each inlet back to the blower. Once you have determined the total static pressure for the system you can use the performance charts in this catalog to determine what blower will meet your needs. National offers two styles of blowers; direct drive and belt drive. The PB and AF blowers are designed for low cfm, high static applications. The belt drive blowers are designed a variety of cfm and static pressure. We also offer in-line belt driven blowers. All of National s blower wheels are non-overloading. III

TUBE TYPE CFM 3 NK 4 NK 5 NK 6 NK 3 flex 4 flex 5 flex 6 flex 8 flex 150.349 - - -.105 - - - - 300 -.299 - - -.089 - - - 500 - -.255.099 - -.077.029-600 - -.349.139 - -.105.042-750 - - -.215 - - -.065.015 1000 - - - - - - - -.025 1200 - - - - - - - -.037 STATIC PRESSURE LOSS PER FOOT OF FLEXIBLE TUBE Rigid Spiral Ductwork CFM 3 4 5 6 8 10 12 14 16 18 150.068 - - - - - - - - - 300 -.059 - - - - - - - - 450 - -.041.017 - - - - - - 600 - -.071.028 - - - - - - 750 - - -.042 - - - - - - 1000 - - - -.016 - - - - - 1200 - - - -.025 - - - - - 1500 - - - -.037.012 - - - - 2100 - - - - -.023.008 - - - 2400 - - - - -.028.012 - - - 2700 - - - - - -.014.006 - - 3000 - - - - - -.016.007 - - 3500 - - - - - -.024.010.005-4000 - - - - - - -.014.006-4500 - - - - - - -.017.008.004 5000 - - - - - - - -.011.006 5500 - - - - - - - -.013.007 6000 - - - - - - - - -.008 CFM 3 4 5 6 8 10 12 14 16 18 STATIC PRESSURE LOSS PER FOOT (2,500 TO 4,500 FPM) NOTE: FOR ELBOWS MULTIPLY THE DIAMETER X 1.5 TO GET STRAIGHT PIPE LENGTH IV

WELDING National also has welding fume removal systems. There are three basic types of systems; weld arms, bench/canopy hoods, and the W-type (pull-up) system. We have three styles of weld arms; externally supported, internally supported and PVC arms. The externally supported weld arm comes in four sizes; WA03 (3-0 reach), WA05 (5-0 reach), WA0710 (7-0 10-0 reach), WA01215 (12-0 15-0 reach). The WA03 and WA05 arms each have a table or wall mount support, and the WA0710 and WA01215 arms can have either a wall or ceiling bracket. Each weld arm can accommodate 3, 4, 5, 6, or 8 diameter RW flexible tube. Each arm comes standard with a stainless steel fume receptor. The internally supported weld arm comes in two standard sizes; NWA010 (10-0 reach) and NWA014 (14-0 reach). Both arms can have either a wall mount or ceiling mount bracket. Each arm can accommodate 6 or 8 diameter RW flexible tube. Each arm comes standard with a powder coated hood. The bench-welding and canopy hoods come in numerous sizes depending on the applications being used. They are constructed of 16 gauge galvanized steel with an option for stainless steel. The W-system is similar to the F-system as noted above. The W-system comes with a weld hood (either stainless steel, galvanized or aluminum), pull-up set and RW flexible tube. Balancer or winch can be substituted for the rope and pulley assembly. In sizing a continuously used weld arm or a W-system, National recommends that for a distance of 10 15 from the weld rod tip to the hood, the rate of exhaust should be 600 cfm minimum. The duct velocity in a welding fume removal system should be 2,500 to 4,500 fpm and a face velocity at the receptor of 1,500 fpm. For some applications where steel, such as galvanized with a toxic fume emitted is being welded, 850 cfm should be used with the same velocities. In sizing a bench welding hood, the first step is to determine the size of the work table. Once you have determined the location of the bench welding hood the length of the hood will be equal to the width of the table. In calculating the airflow for the bench welding hoods use the formula: Q=V(5(X X) + A). Q = air flow, cfm V = capture velocity, fpm, at distance x (50 fpm for welding applications) X = distance from hood face to farthest point of contaminant release, ft A = area of hood opening, square feet V

DUST COLLECTION National Systems offers a Thor-Kleen cyclone collector. Our collectors can exhaust from 311 to 8000 cfm. We offer numerous optional accessories. In sizing a dust collection system you first must determine the number of pick-up points. Many pieces of equipment have a port to attach a removal system. Typically drops require a minimum of 300 cfm. After having this information you have the total cfm required for the system. We recommend that at least one floor sweep be added to the system. The floor sweep should be rated for 600 cfm. Now that the total cfm is secured you then need to calculate the static pressure in system. The external static pressure is calculated the same the at-the-source fume removal systems. Then you must add the internal static pressure in the cyclone. The typical rule of thumb is approximately 1 1/2 to 2. SENSORS National System of Garage Ventilation offers a variety of sensors. Our sensors monitor carbon monoxide, nitrous dioxide, and carbon dioxide. They detect an area of 5000 square feet. We offer stand alone sensors as well as sensors tied to a common controller. We do have a dual gas detector that monitor s carbon monoxide and nitrous dioxide. VI

National System of Garage Ventilation EXHAUST REMOVAL SYSTEM SURVEY Scale inch = feet Please fax completed form to: 217-422-5387 Firm Name Legend Address X = Inlets City State Zip B = Blower Contact D = Dyno Phone Fax email O = Obstructions Type of Building: Block Wood Metal Other Ceiling Height: Eaves Roof: Flat Pitched to ratio Electrical: phase cycle volts Types of Vehicles: Gasoline Diesel Propane Natural Gas Cars Pick-up Motorcycles Semi-Trucks Farm Equip. Emergency Vehicles Military Equip. Construction Equip. Other Condition of Vehicles being serviced Idle High-Idle Engine Dyno Chasis Dyno Number of bays Type of System Desired: Overhead Underfloor Blower Location: Ceiling Wall Roof Exhaust Through: Roof Wall Door Engine Data: HP Turbocharged: Yes No Maximum Operating RPM VII