Residual Gas Analyzers



Similar documents
QGA Quantitative Gas Analyser

Multi-Range Programmable DC Power Supplies 9115 Series

Temperature & Humidity SMS Alert Controller

High Power Programmable DC Power Supplies PVS Series

Frequency selective monitoring and logging of environmental electromagnetic fields

1.44 kw Programmable DC Power Supplies XLN Series

NIM High Voltage Power Supplies

USB-500/600 Series Low-Cost Data Loggers and Accessories

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Vacuum drying oven for non-flammable solvents

The Universal DAQ Device. Connect and measure immediately!

For Multi-Parameter Meters see mvx

USB-500 Series Stand-Alone, Low-Cost Data Loggers

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Centro-Matic Automatic Lubrication Systems System Controls

VDL 53 - Vacuum drying oven for flammable solvents

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Thermal Mass Flow Meters and Controllers for Gases

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

USB-500/600 Series Low-Cost Data Loggers and Accessories

Physical Specifications (Custom design available.)

Automated Test System SIMPLICITY COUNTS MSA s New GALAXY GX2 Automated Test System / Advanced Safety Management Effortless Operation

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Commercial Semi-Instantaneous Water Heaters

Automatic tank gauge system ATGs for petrol stations, diesel fuel tank level gauge, tank gauging system, magnetostrictive probe

Battery Powered Digital Mass Flow Meters for Gases

Mitos P-Pump. product datasheet

User's Guide. Integrating Sound Level Datalogger. Model Introduction

PIEZOMETER AIRFLOW MEASURING RING

Qingdao Guihe Measurement&Control Technology Co., Ltd. Automatic Tank Gauging System, Magnetostrictive Diesel fuel tank level gauge

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Tuning & Mass Calibration

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

FFT Spectrum Analyzers

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

Typical Aluminum GFM Mass Flow Meter

Overview. Inficon s Product

Ron 3025 Crane Scale with 1"/25mm Display

PRODUCT REVIEW. Flowmeters and Controllers. Vacuum Instrumentation

OEM-EP Pressure Controllers

PERF10 Rubidium Atomic Clock

Rackmount Intelligent Pressure Scanners

Features, Benefits, and Operation

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

O C M III. Open Channel Flow Monitor

Hydras 3 LT Quick Start

Product Information Sheet UH36 Hi Pot Tester

EV-1000 Series DVR. Quick Operation Guide. Version 1.0.0

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Multi-Range Programmable DC Power Supplies 9115 Series

KNC Model 3666 Automatic Pressure Calibration System

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Transmitter Interface Program

LI-7000 CO /H O Analyzer. High Speed, High Precision Differential Analyzer

How To Use A Ds340 (Dsp)

Dual Laser InfraRed (IR) Thermometer

MAESTRO 7. Multichannel Analyzer (MCA) Application Software

DPI 260 SERIES: Digital Pressure Indicators

SA-9600 Surface Area Software Manual

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

Mobile Communications DC Sources W

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Introduction to vacuum gauges. Vacuum Gauges where the Pressure Readings are Independent of the Type of Gas (Mechanical Vacuum Gauges)

FREQUENCY RESPONSE ANALYZERS

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

4-Channel Thermometer / Datalogger

OMNIYIG. .5 TO 2 GHz, 1 TO 4 GHz, 6 to 18 GHz Thin Film YIG-TUNED OSCILLATORS OUTLINE DIMESIONS MOUNTING SURFACE GND +15V + TUNE - HTR HTR

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

DIGITAL DISPLACEMENT RISING STEP LOAD LRA/RSL TEST EQUIPMENT

STIM202 Evaluation Kit

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

Wireless Data Logger Monitoring Systems

In-Sight Hardware specifications

Uninterruptible Power Supply

USB-500 Series Low-Cost Data Loggers and Accessories

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

Nikon s DigiMicro Position Encoders Nanometer Resolution with Sub-Micron Accuracy

MAGTROL. DSP6001 High-Speed Programmable Dynamometer Controller. DSP6001 Data Sheet FEATURES APPLICATIONS MOTOR TESTING SOFTWARE DESCRIPTION

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

REAL-TIME DUST AND AEROSOL MONITORING

Line Level Converter Box. S Class Signal Processors

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

DC Electronic Loads 8500 series

PSM 900 and PSM 1000 Personal Monitor Systems TWO SYSTEMS. INFINITE POSSIBILITIES.

MATRIX TECHNICAL NOTES

Online Infrared Flue Gas Analyzer Gasboard 3000

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

OxySense Gen III Operations Manual

SMS GSM Alarm Messenger

Model #: SMART2200CRMXL

How To Use A High Definition Oscilloscope

Continuous, remote monitoring and logging of electromagnetic fields

Transcription:

Residual Gas Analyzers RGA100/200/300 100 amu, 200 amu and 300 amu systems SRS Residual Gas Analyzers 100, 200 and 300 amu systems Better than 1 amu resolution 6 decades of dynamic range 5 10 14 Torr detection limit RGA Windows & LabVIEW software Field-replaceable electron multiplier and filament RS-232 interface The 100, 200 and 300 amu residual gas analyzers from SRS offer exceptional performance and value. These RGAs provide detailed gas analysis of vacuum systems at about half the price of competitive models. Each RGA system comes complete with a quadrupole probe, electronics control unit (ECU), and a real-time Windows software package that is used for data acquisition and analysis, as well as probe control. Rugged Probe Design The probe consists of an ionizer, quadrupole mass filter, and a detector. The simple design has a small number of parts which minimizes outgassing and reduces the chances of introducing impurities into your vacuum system. The probe assembly is rugged and mounts onto a standard 2.75" Conflat flange. It is enclosed within a stainless steel tube, with the exception of the ionizer which requires just 2.5" of clearance in your vacuum system about that of a standard ion gauge. The probe is designed using self-aligning parts so it can easily be reassembled after cleaning. Compact Electronics Control Unit RGA100... $3750 (U.S. list) RGA200... $4750 (U.S. list) RGA300... $6250 (U.S. list) The densely packed ECU contains all the necessary electronics for controlling the RGA head. It is powered by either an external +24 VDC (2.5 A) power supply or an optional, built-in power module which plugs into an AC outlet. LED indicators provide instant feedback on the status of the electron multiplier, filament, electronics system and the

RGA100/200/300 Residual Gas Analyzers probe. The ECU can easily be removed from the probe for high-temperature bakeouts. Unique Filament Design A long-life, dual thoriated-iridium (ThO 2 /Ir) filament is used for electron emission. Dual ThO 2 /Ir filaments last much longer than single filaments, maximizing the time between an optional electron multiplier is offered that detects partial pressures down to 5 10 14 Torr. This state-of-the-art, multichannel, continuous-dynode electron multiplier (EM) offers increased longevity and stability, and can also be replaced by the user a first for RGAs. Useful Features SRS RGAs have a built-in degassing feature. Using electron impact desorption, the ion source is thoroughly cleaned, greatly reducing the ionizer s contribution to background noise. A firmware driven filament protection feature constantly monitors (675 Hz) for over pressure. If over pressure is detected, the filament is immediately shut off, preserving its life. A unique temperature-compensated, logarithmic electrometer detects ion current from 10 7 to 10 15 amps in a single scan, with better than 2 % precision. This huge dynamic range means you can make measurements of small and large gas concentrations simultaneously. Complete Programmability Dual ThO 2 /Ir filament filament replacement. Unlike other designs, SRS filaments can be replaced by the user in a matter of minutes. Continuous Dynode Electron Multiplier Communication with computers is made via the RS-232 interface. Analog and histogram (bar) scans, leak detection, and probe parameters are all controlled and monitored through a high-level command set. This allows easy integration into existing programs. RGA Windows Software The RGA systems are supported with a real-time Windows software package that runs on PCs. The intuitive graphical user interface allows measurements to be made quickly A Faraday cup detector is standard with all SRS RGAs, allowing partial pressure measurements from 10 5 Torr to 5 10 11 Torr. For increased sensitivity and faster scan rates, RGA Windows software Analog mode Continuous dynode electron multiplier and easily. The program is fully interactive, giving the user complete control of the graphical display. Screens can be split for dual-mode operation, scales can be set to linear or log format, and data can be scaled manually or automatically. Data is captured and displayed in real time or scheduled for acquisition at a given time interval for long-term data logging. Features include user-selectable units (Torr, mbar, Pa and A), programmable audio and visual alarms, and comprehensive on-line help. Stanford Research Systems phone: (408)744-9040

RGA100/200/300 Residual Gas Analyzers The software also allows complete RGA head control with easy mass scale tuning, sensitivity calibration, ionizer setup, and electron-multiplier gain adjustment. For further analysis, data files can be saved in ASCII format for easy transfer into spreadsheets. Graphic images can be saved as META files or copied to the clipboard for importing directly into other Windows programs. The software also provides password protection for locking out head parameters so that casual users can t alter important settings. A LabVIEW driver is also available on the SRS website. An optional stand-alone monitor (PPM100) can be used to control the RGA without a host computer. Multi-Head Operation The software supports multiple head operation when more than one RGA is needed. Up to eight ECUs can be monitored from the software. Performance and Value The SRS family of RGAs is ideal for applications involving gas analysis, leak detection, and vacuum processing. We offer 100, 200 and 300 amu systems with supporting Windows software, and options that include an electron multiplier and a built-in power module for AC line operation. The RGA Windows software is available on the web at. RGA rear panel (without AC power module) RGA rear panel (with AC power module) RGA dimensional drawing (inches)

RGA100/200/300 Software Analog mode provides a line graph representation of the acquired mass spectrum (partial pressure vs. mass number). Span, resolution and noise floor can each be set. Scans can be single-shot, timed or taken continuously. Pressure vs. time presents a strip chart of partial pressures for selected masses, and provides a complete time history of your data. Complete scrolling and zoom control is available even while data is being acquired. This mode is most often used for monitoring process trends. Library mode contains a comprehensive list of gases that can be used to compare against the current spectrum. A search mode allows you to select up to 12 masses and identify and display (numerically and graphically) the intensity of all gases that contain these masses. Histogram mode displays a bar graph of partial pressure vs. mass, allowing the spectrum to easily be interpreted. This mode is often used for quick and easy vacuum analysis. The screen can be split for viewing two modes of operation simultaneously. Leak detection mode monitors a particular mass number (not just helium) over time, and combines many features of the previous modes. A vertical bar graph provides a visual reference for viewing changes in intensity from a distance. A programmable audible tone, large numeric read-out, and visual alarm are also provided. Analysis utility provides an approximation of the composition of gases being monitored by the RGA. Since more than one gas can contribute to a particular amu s partial pressure, the analysis mode is extremely useful in determining the makeup of complex gases. Up to 12 common gases can be selected for the analysis. Table mode provides a readout of mass, scaling factor, and true partial pressure. The display shows the peak heights and alarm status of up to 10 masses. The electron multiplier can be independently set on or off for each mass. This allows the user to view minor species even in the presence of high total pressure. Annunciator mode is provided for conveniently monitoring up to 10 masses. If a particular mass has tripped its preset alarm, the large box will turn red indicating a problem. An audible alarm will also be present until the mass falls back within its preset limits. This mode is most often used for Go/No-Go testing. Multi-head operation is available when more than one RGA is needed for analysis. Up to eight heads can be monitored simultaneously from the software. Stanford Research Systems phone: (408)744-9040

RGA100/200/300 Specifications Operational Mass range RGA100 1 to 100 amu RGA200 1 to 200 amu RGA300 1 to 300 amu Mass filter type Quadrupole Detector type Faraday cup (FC), standard Electron multiplier (EM), optional Resolution Better than 0.5 amu @ 10 % peak (per AVS std. 2.3) height. Adjustable to constant peak width throughout the mass range. Sensitivity (A/Torr) 2 10 4 (FC), <200 (EM). User adjustable throughout high voltage range. Measured with N 2 @ 28 amu with 1 amu full peak width, 10 % height, 70 ev electron energy, 12 ev ion energy, and 1 ma electron emission current. Minimum detectable 5 10 11 Torr (FC), partial pressure 5 10 14 Torr (EM) Measured with N 2 @ 28 amu with 1 amu full peak width, 10 % height, 70 ev electron energy, 12 ev ion energy, and 1 ma electron emission current. Operating range 10 4 Torr to UHV (FC) 10 6 Torr to UHV (EM) Operating temperature 70 C (max.) Bakeout temperature 300 C (without ECU) Ionizer Design Open ion source, cylindrical symmetry, electron impact ionization Material SS304 construction Filament Thoriated iridium (dual) with firmware protection. Built-in 1 to 10 W degas ramp-up. (Field replaceable) Electron energy 25 to 105 V, programmable Ion energy 8 or 12 V, programmable Focus voltage 0 to 150 V, programmable Electron emission current 0 to 3.5 ma, programmable General Probe dimension 8.75" from flange face to top of ionizer Probe insertion 2.0" Probe mounting flange 2.75" CF Minimum tube I.D. 1.375" ECU dimensions 3.1" 4.1" 9.1" (WHD). Easily separated from the probe for bakeout. LED indicators Power ON/OFF, filament ON/OFF, degas ON/OFF, electron multiplier ON/OFF, RS-232 Busy, Error, Overpressure, Burnt Filament Warm-up time Mass stability ±0.1 amu after 30 min. Computer interface RS-232C, 28,800 baud with highlevel command set Software Power requirement Weight Warranty Windows based application 24 VDC @ 2.5 amps, male DB9 connector, optional built-in power module for AC line operation 6 lbs. One year parts and labor on defects in materials and workmanship Ordering Information RGA100 100 amu RGA w/ RS-232 $3750 RGA200 200 amu RGA w/ RS-232 $4750 RGA300 300 amu RGA w/ RS-232 $6250 Option 01 Electron multiplier $1500 Option 02 AC power module $250 Option 03 Ion counting output $250 O100HJR 200 C heater jacket $450 O100MAX Max. insertion nipple (4.5" CF) $600 O100REA Ethernet adapter for RGA $495 O100EM Replacement electron multiplier $1000 O100RF Replacement ThO 2 /Ir filament $200 O100RI Replacement ionizer kit $450 (includes filament) PPM100 Optional stand-alone monitor $2495 Maximum insertion nipple (O100MAX)