Series 5 Pluvia outlets Page 3 Series 5 Outlet accessories Page 4 Series 7 Pluvia outlets Page 4 Series 7 Pluvia accessories Page 9 Series 7 Pluvia spares Page 11 Series 7+ Pluvia outlets Page 13 PluviaFix Brackets Page 15 Prouct Guie PluviaFix square profile rail system Page 17 PluviaFix pipe brackets with threae fastening Page 18 PluviaFix C profile track system for pipe iameters 250-315 Page 19 Mounting plates Page 20 Electrofusion tape for anchor bracket Page 22 PluviaFix support sets Page 23 PluviaFlex Page 24 Installation Guie Page 27 Numerical Inex Page 39 Pluvia Prouct an Installation Guie 2011 1
Prouct Guie Introuction Geberit Pluvia is the leaing siphonic roof rainage system use for over 30 years aroun the worl in over 80,000 installations to rain 80 million sq metres through 300,000 outlets. Architects, Consultants an Contractors have chosen the system for some of the most prestigious an groun breaking builing esigns ue to the freeom an flexibility it provies. Pluvia uses the ingenious gravity inuce vacuum principle to create a siphonic action, which allows the complete rainage of a roof area with smaller iameter pipes than use in a conventional gravity system. Geberit Siphonic roof systems are wiely use in the inustrial an coercial sector for all roofs. Geberit Pluvia Avantages: New architectural flexibility in builing an use No slope in pipework require Less unergroun pipe work Less sitework Fewer pipes an fittings Reuce pipe imensions Less space require Self cleaning action A simple an speey fastening system Conventional System Siphonic System Pipe Fall Fall 1-3 % No Fall Necessary Down Pipes Many Down Pipes Fewer Down Pipes Unergroun Pipes Long Unergroun Pipes Short Unergroun Pipes The Geberit Pluvia System is fully approve by the BBA. This inclues outlets, pipes & fittings, an the eicate esign software. All installations carry a minimum of a ten year prouct liability guarantee, an must be carrie out by a Geberit Pluvia approve installer. The prouct range inclues outlets to suit most roof esigns an finishes, with a comprehensive range of contact foils to suit the majority of roof membrane materials currently on the market. RIBA approve CPD seminars are available. Please contact Geberit for more information. 2 Pluvia Prouct an Installation Guie 2011
Prouct Guie Pluvia outlets Series 5 Pluvia Series outlets 5 Series 5 Pluvia outlets Flange 6 litre Pluvia outlet stainless steel Drainage capacity max. 6 l/s Article no. PU1 PU4 359.500.00.1 1 13 6 litre Pluvia outlet (without flange) stainless steel h D h1 H 1 K For installation in gutters mae from chrome-nickel steel Drainage capacity max. 6 l/s Outlet grating; Protection housing Article no. Ø 1Ø D cm H cm 359.514.00.1 56 170 21,5 13,5 11 7 2,5 1 45 h cm h1 cm K cm PU1 PU4 Pluvia Prouct an Installation Guie 2011 3
Prouct Guie Series 7 Series 5 Outlet accessories / Series 7 Pluvia outlets Series 5 Outlet accessories / Series 7 Pluvia outlets Series 5 Outlet accessories Series 5 gravel ring Series Pluvia outlets 7 Series 7 Pluvia outlets Series 7 Pluvia outlet with clamping ring, universal for plastic membranes 30 29 9 5 7 Prouct material Stainless steel 0-26 5 29 5 10-36 5 Article no. PU1 359.511.00.1 1 Series 5 clamping ring For collecting an raining of rainwater on roofs For siphonic roof rainage system For connection of plastic roof membranes Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Maintenance free clamping flange connection Drainage capacity min. Drainage capacity max. Height of aing 1 l/s 12 l/s 35 Article no. PU1 359.512.00.1 1 Series 5 grating Outlet grating with operating part; Outlet connection flange with seal an nuts; Base unit with integrate outlet isk mae of metal; Conensation protection Article no. Ø PU1 PU4 359.003.00.1 56 1 24 Spare part for Pluvia series 5 ø 56 Prouct material PP Article no. Ø PU1 359.510.00.1 56 1 4 Pluvia Prouct an Installation Guie 2011
Prouct Guie Pluvia outlets Series 7 Series 7 Pluvia outlet with clamping ring for bitumen roofs Geberit Pluvia roof outlet, 12 l, 56, with punche contact sheet an bitumen roof foil 52 29 72 52 29 0-15 29 5 9 5 7 10-25 0-15 29 5 9 5 7 10-25 For collecting an raining of rainwater on roofs For siphonic roof rainage system For connecting with roof foils For connecting with bitumen roof foils Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Drainage capacity min. Drainage capacity max. Height of aing Bitumen roof outlet element, complete (base unit with integrate outlet isk, wele-on flange bolts, fastening flange, wing nuts); Insulation; Outlet grating with operating part Exclue: Protection box cover Article no. Ø PU1 PU4 358.010.00.1 56 1 27 1 l/s 12 l/s 35 For collecting an raining of rainwater on roofs For siphonic roof rainage system For connecting with bitumen roof foils Loa of the outlet grating < 150 kg Base unit with integrate outlet isc Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Bitumen roof sheet (SBS), flare at the factory, 4.5 Drainage capacity min. Drainage capacity max. Height of aing Base unit with integrate outlet isk mae of metal; Insulation against conensation; Outlet grating with operating part; Protective cap Article no. Ø PU1 359.029.00.1 56 1 1 l/s 12 l/s 35 Pluvia Prouct an Installation Guie 2011 5
Prouct Guie Series 7 Series 7 Pluvia outlet with insulation block Series 7 Pluvia outlet without insulation block Pluvia outlets 0-13 9 5 7 10-23 For collecting an raining of rainwater on roofs For siphonic roof rainage system For connection with all kins of roof sealing material For insulate an non-insulate roofs 29 29 5 Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Loa of the outlet grating < 150 kg 10-23 0-13 For collecting an raining of rainwater on roofs For siphonic roof rainage system For connection with all kins of roof sealing material For combining with the universal contact sheet Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Loa of the outlet grating < 150 kg Drainage capacity min. Drainage capacity max. Height of aing 29 9 5 1 l/s 12 l/s 35 Drainage capacity min. Drainage capacity max. Height of aing Base unit; Outlet isk; Outlet grating with operating part; Insulation against conensation; Protective cap; Fastening material; Lubricants Article no. Ø PU1 PU4 359.551.00.1 56 1 40 1 l/s 12 l/s 35 Base unit with locking screw; Outlet isk; Outlet grating with operating part; Protective cap Article no. Ø PU1 PU4 359.563.00.1 56 1 40 Series 7 Pluvia outlet with stainless steel flange 52 29 0-15 29 5 For collecting an raining of rainwater on roofs For siphonic roof rainage system For connecting with bitumen roof foils 9 5 7 10-25 Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Loa of the outlet grating < 150 kg Base unit with integrate outlet isc Drainage capacity min. Drainage capacity max. Height of aing 1 l/s 12 l/s 35 6 Pluvia Prouct an Installation Guie 2011 Base unit with integrate outlet isk mae of metal; Insulation against conensation; Outlet grating with operating part; Protective cap Article no. Ø PU1 PU4 359.571.00.1 56 1 27
Prouct Guie Pluvia outlets Series 7 Series 7 Pluvia gutter outlet Series 7 Pluvia promenae outlet 32 29 32 5 315 2 0-15 For collecting an raining of rainwater on roofs For siphonic roof rainage system For installation in gutters with a minimum of 35 cm with For connecting metallic materials Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Loa of the outlet grating < 150 kg Base unit with integrate outlet isc Drainage capacity min. Drainage capacity max. Height of aing Connecting material 29 5 1 l/s 12 l/s 35 PE-HD Base unit with integrate outlet isk mae of metal; Insulation against conensation; Outlet grating with operating part; Protective cap Article no. Sealing of connection Ø PU1 PU4 359.636.00.1 Chrome-nickel steel 56 1 12 359.637.00.1 Copper 56 1 359.638.00.1 Peraluman 56 1 12 7 9 5 10-25 0-13 For collecting an raining of rainwater on roofs For siphonic roof rainage system For connecting with roof foils For inverte roofs For roofs with vegetation For weight-bearing roofs Do not use for roofs in which the maximum permitte loa on the grating (1500 kg) will be exceee Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Duct pipe can be shortene to a minimum of 4 cm Loa bearing capacity 1500 kg Duct pipe extenable by weling with corresponing spare part Drainage capacity min. Drainage capacity max. Height of aing 29 5 35 6-30 7 10-23 1 l/s 12 l/s 35 Base unit; Outlet isk; Function isk; Insulation against conensation; Aitional set, weight-bearing; Protective cap; Fastening material; Lubricants Article no. Ø PU1 PU4 359.562.00.1 56 1 8 Pluvia Prouct an Installation Guie 2011 7
Prouct Guie Series 7 Series 7 Pluvia horizontal outlet Pluvia 2 tier outlet (lower element for sealing penetration through vapour barrier) Pluvia outlets 29 29 9 5 11 5 9 5 4-18 For collecting an raining of rainwater on roofs For siphonic roof rainage system Mainly for renovate roofs if an aitional thermal insulation is installe on the existing roof insulation For connection with all kins of roof sealing material For horizontal pipe connection Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Low installation height Loa of the outlet grating < 150 kg Drainage capacity min. Drainage capacity max. Height of aing 21 Base unit with horizontal outlet ø 56; Fastening material; Outlet isk; Outlet grating with operating part; Protective cap; Lubricants Article no. Ø PU1 PU4 359.565.00.1 56 1 48 1 l/s 6 l/s 35 0-13 For collecting an raining of rainwater on roofs For siphonic roof rainage system For connection with all kins of roof sealing material For connecting vapour barriers up to 3 thick Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Loa of the outlet grating < 150 kg Clamping ring with pull-out protection up to 120 kg Drainage capacity min. Drainage capacity max. Height of aing 29 5 7 10-23 Base unit; Outlet isk; Outlet grating with operating part; Insulation against conensation; Loose flange; Protective cap; Fastening material; Lubricants Article no. Ø PU1 PU4 359.550.00.1 56 1 24 1 l/s 12 l/s 35 8 Pluvia Prouct an Installation Guie 2011
Prouct Guie Pluvia accessories Series 7 Pluvia accessories Series 7 Pluvia accessories Series 7 retrofit promenae top element Series 7 Pluvia overflow aaptor 23 21 32 5 315 2 5 6-30 2 5-5 5 For later construction of roofs in the case of reverse roofs, accessible or green roofs For use with all Pluvia roof outlets 12 l Loa bearing capacity 1500 kg Grating; Frame of grating; Force istribution plate; Duct pipe, can be cut to length; Fastening material Article no. PU1 PU4 359.635.00.1 1 12 35 Pluvia grating, loa bearing 1500kg for promenae 32 2 11 For Pluvia roof outlets with max. rainage capacity 12 l/s Overflow element can be cut to length Overflow height Height of aing Lip seal EPDM 50 65 Article no. PU1 PU4 Coents 358.007.00.1 1 45 Incluing plastic mounting clips for plastic function isk 358.013.00.1 1 Incluing metal mounting clips for metal function isk Set of Pluvia mounting clips for overflow aaptor (spare) For car park use, 1500kg For promenae outlet Article no. PU1 240.242.00.1 1 2 mounting clips for plastic outlets; 2 mounting clips for metal outlets Article no. PU1 240.008.00.1 1 Pluvia grating, light loa bearing, 150 kg for promenae 32 Pluvia contact foil 32 0 2 For peestrian use, 150kg For promenae outlet Fastening material Article no. PU1 240.647.00.1 1 For connecting metallic materials For installation in gutters with a minimum of 35 cm with Conensation insulation ring Article no. Sealing of connection PU1 PU2 359.554.00.1 Chrome-nickel steel 1 10 359.555.00.1 Copper 1 359.556.00.1 Peraluman 1 Pluvia Prouct an Installation Guie 2011 9
Prouct Guie Series 7 Pluvia spares Pluvia contact foil Series 7 Pluvia contact clamping flange 50 36 For connecting with roof foils Article no. Sealing of connection PU1 PU4 359.575.00.1 PVC - Sarnafil G 410-18 1 359.577.00.1 EPDM - Resistit Perfekt E 1 359.579.00.1 PVC - Sikaplan 15 G 1 66 For connecting metallic materials For making a mechanical connection For installing in gutters minimum 38 cm wie Article no. PU1 359.568.00.1 1 Pluvia contact foil bitumen Pluvia installation sheet 50 60 3 6 26 5 For connecting with bitumen roof foils Protection box cover, heat-resistant Article no. PU1 359.578.00.1 1 Pluvia contact foil stainless steel For fastening the base unit on trapezoial roofs For use with all Pluvia roof outlets 12 l Hot-ip galvanise Prouct material Article no. PU1 PU4 359.558.00.1 1 60 Steel 52 Pluvia storm set For connecting with bitumen roof foils Protection box cover, heat-resistant; Conensation insulation ring Article no. Sealing of connection PU1 359.560.00.1 Chrome-nickel steel 1 For stormproof attachment of the Pluvia 12 litre outlet grating Can also be use for Pluvia roof outlets with emergency overflow set 2 clips; 2 spacers; 2 washers; 2 washer sleeves; 2 cap nuts Article no. 358.012.00.1 Pluvia spares 10 Pluvia Prouct an Installation Guie 2011
Prouct Guie Pluvia spares Series 7 Series 7 Pluvia spares Pluvia perforate upstan for promenae outlet Pluvia Base Element 1 1 28 0-13 For use with Pluvia roof outlets 12 l with HDPE base units For siphonic roof rainage system For connecting vapour barriers up to 3 thick For combination with Pluvia vapour barrier connection, fastening isk an contact foil Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Drainage capacity max. Connecting material Base unit; Insulation against conensation; Protective cap Exclue: Fastening isk; Fastening material Article no. Ø PU1 PU4 359.631.00.1 56 1 48 29 5 7 10-23 12 l/s PE-HD Article no. PU1 PU4 240.240.00.1 1 20 Pluvia 2 tier outlet, lower element for sealing penetration through vapour barrier 0-13 For use with Pluvia roof outlets 12 l with HDPE base units For siphonic roof rainage system For connecting vapour barriers up to 3 thick Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Clamping ring with pull-out protection up to 120 kg 315 29 5 7 10-23 Pluvia base plate for uct, loa bearing for promenae Connecting material Drainage capacity max. PE-HD 12 l/s Article no. PU1 240.239.00.1 1 35 31 8 23 Base unit; Fastening isk; Insulation against conensation; Fastening material; Protective cap; Lubricants Article no. Ø PU1 PU4 359.552.00.1 56 1 48 Pluvia frame for loa bearing gratings for promenae 32 5 Clamping flange for vapour barrier membrane 25 29 3 2 2 For connecting vapour barriers up to 3 thick Shoul not be use for connecting insulating roof foils Article no. PU1 240.241.00.1 1 Article no. PU1 PU3 PU4 359.553.00.1 1 15 240 Pluvia Prouct an Installation Guie 2011 11
Prouct Guie Series 7 Pluvia spares Fastening isc for vapour barrier Pluvia outlet isk for roof outlet 25 25 2 O-rings EPDM; Lip seal EPDM; Clamping ring; Locking screw Article no. PU1 240.238.00.1 1 Article no. Ø 240.237.00.1 56 Gravel ring 28 5 Lip seal an grab ring for fastening isc for vapour barrier For vapour barrier outlet Article no. PU1 240.231.00.1 1 For holing back roof gravel with a grain size of 8-16 For combination with Pluvia outlet grating Prouct material Article no. PU1 PU4 359.567.00.1 1 34 5 2 Stainless steel Pluvia outlet grating for roof outlet Pluvia fastening isc for roof outlet 22 5 21 2 O-rings EPDM Article no. Ø PU1 240.236.00.1 56 1 For Pluvia roof outlets with max. rainage capacity 12 l/s Article no. PU1 PU4 359.561.00.1 1 34 Pluvia protection cover, fire resistant 29 9 5 28 Set of seals for outlet fastening iscs Roun cor ring EPDM ø 62 x 6 ; Roun cor ring EPDM ø 134 x 6 Article no. PU1 PU2 240.232.00.1 1 5 For use with a blowlamp Heat-resistant Article no. Ø PU1 359.566.00.1 56 1 12 Pluvia Prouct an Installation Guie 2011
Prouct Guie Pluvia outlets Series 7+ Pluvia Series outlets 7+ Series 7+ Pluvia outlets Series 7+ flange Pluvia outlet stainless steel Pluvia roof outlet 25 l universal for plastic roof membranes 60 32 7 For collecting an raining of rainwater on roofs For siphonic roof rainage system For connection of plastic roof membranes May not be use for flange mounting roof foils with fleece coating (e. g. Rhepanol fk) Loa of the outlet grating < 150 kg 80 C heat resistant Base unit with integrate outlet isc Outlet grating with function isc Fix installe HDPE outlet pipe ø 90 Outlet pipe irectly reucible / extenable Maintenance free clamping flange connection Drainage capacity min. Drainage capacity Height of aing 50 32 28 Outlet grating with operating part; Outlet connection flange with seal an nuts; Base unit with integrate outlet isk mae of metal; Protection housing Article no. Ø PU1 359.012.00.1 90 1 7 8 5 16 8 l/s 25 l/s 55 For collecting an raining of rainwater on roofs For siphonic roof rainage system For connecting with bitumen roof foils Loa of the outlet grating < 150 kg 80 C heat resistant Base unit with integrate outlet isc Outlet grating with function isc Fix installe HDPE outlet pipe ø 90 Outlet pipe irectly reucible / extenable Drainage capacity min. Drainage capacity Height of aing Outlet grating with operating part; Outlet connection flange with seal an nuts; Base unit with integrate outlet isk mae of metal; Protection housing Article no. Ø PU1 PU4 359.573.00.1 90 1 7 Series 7+ Pluvia outlet stainless steel without flange 32 28 28 8 15 For collecting an raining of rainwater on roofs For siphonic roof rainage system For installation in gutters with a minimum of 35 cm with For connecting metallic materials 7 5 8 5 16 8 l/s 25 l/s 55 Loa of the outlet grating < 150 kg 80 C heat resistant Base unit with integrate outlet isc Outlet grating with function isc Fix installe HDPE outlet pipe ø 90 Outlet pipe irectly reucible / extenable Drainage capacity min. Drainage capacity Height of aing 8 l/s 25 l/s 55 Outlet grating with operating part; Base unit with integrate outlet isk mae of metal Exclue: Protection cover Article no. Ø PU1 PU4 359.544.00.1 90 1 24 Pluvia Prouct an Installation Guie 2011 13
Prouct Guie Pluvia rail an fixing system Pluvia grating for outlet 25 l/s Pluvia outlets Geberit Pluvia vapour barrier connection vertical 25 l 32 60 8 10 5 For all Pluvia roof outlets with 25, 45, 60 or 100 l/s flow capacity Integrate function isc Lock nut Article no. PU1 359.543.00.1 1 Emergency overflow set for Pluvia roof outlets 25 l 31 5 27 For use with Pluvia roof outlets with max. rainage capacity 25 l/s 5 5 For collecting an raining of rainwater on roofs For siphonic roof rainage system For combination with Geberit Pluvia roof outlets 25 l For use with insulate roofs with vapour barrier For connecting plastic or bitumen vapour barriers Fix installe HDPE outlet pipe ø 90 Outlet pipe irectly reucible / extenable Contact sheet galvanize Drainage capacity min. Drainage capacity Height of aing Protective cap Article no. Ø PU1 359.027.00.1 90 1 ø 9 8 l/s 25 l/s 55 Overflow height Height of aing 50 100 Pluvia rail an fixing system Roun cor ring EPDM; Fastening material Article no. PU1 PU4 358.008.00.1 1 34 14 Pluvia Prouct an Installation Guie 2011
PluviaFix Brackets Prouct Guie Pluvia rail an fixing system PluviaFix Brackets PluviaFix Brackets PluviaFix pipe bracket for guie an anchor point L For attaching pipes to ceilings an vertically to walls For fastening with tension wege For fastening to the PluviaFix support rail square profile For slie fastening of pipes For anchor-point fastening of pipes in combination with electrowel couplings or tapes For rigi fixing of 40 HDPE pipework Galvanise Prouct material Steel Exclue: Tension wege Article no. Ø 360.861.00.1 40 11 1 10 L cm Please note: For conventional brackets please see the HDPE Prouct Guie. PU1 PU2 Pluvia Prouct an Installation Guie 2011 15
Prouct Guie Pluvia rail an fixing system PluviaFix Brackets PluviaFix pipe bracket for guie an anchor point L1/L2 For attaching pipes to ceilings an vertically to walls For fastening with tension wege For fastening to the PluviaFix support rail square profile For slie fastening of pipes For anchor-point fastening of pipes in combination with electrowel couplings or tapes For rigi fixing of HDPE pipework 50 to 100 Galvanise 1 2 Prouct material Steel Exclue: Tension wege Article no. 1Ø 2Ø L1 cm L2 cm PU1 PU2 PU4 361.861.00.1 50 58 10,9 11,3 1 10 1000 363.861.00.1 56 64 11,2 11,6 1 10 1000 364.861.00.1 63 71 11,8 12,2 1 10 1400 365.861.00.1 75 83 12,4 12,8 1 10 640 366.861.00.1 90 98 13,3 13,7 1 10 640 367.861.00.1 110 118 14,4 14,8 1 10 640 368.861.00.1 125 133 15,1 15,5 1 10 400 369.861.00.1 160 168 17 17,4 1 10 400 PluviaFix pipe bracket for guie an anchor point L1/L2 1 2 For fastening with tension wege For fastening to the PluviaFix support rail square profile For slie fastening of pipes For attaching pipes to ceilings an vertically to walls For anchor-point fastening of pipes in combination with electroweling tapes Galvanise With securing clip Prouct material Steel Securing clip Exclue: Tension wege Article no. Ø 1Ø 2Ø L1 L2 Colour PU1 PU2 PU4 cm cm 370.861.26.1 200 200 208 19 19,4 Galvanise / blue passivate 1 10 180 16 Pluvia Prouct an Installation Guie 2011
PluviaFix square profile track system Prouct Guie Pluvia rail an fixing system PluviaFix square profile track system PluviaFix square profile rail system PluviaFix steel square section rail L(m) 3 PluviaFix suspension element for steel square section rail M10 2 4 7 M10 3 3 3 For attaching pipes to ceilings an vertically to walls For fastening of pipe brackets with clamp fastening Galvanise Square profile Prouct material Article no. L (m) m Colour Steel PU2 m PU4 m 362.863.26.1 5 Galvanise / blue passivate 5 500 For attaching pipes to ceilings an vertically to walls For fastening steel square section rail Galvanise Female threa With long threa coupling wele on Prouct material Exclue: Tension wege Steel Article no. Colour PU1 PU2 PU4 362.862.26.1 Galvanise / blue passivate 1 10 2100 PluviaFix connection element for steel square section rail PluviaFix tension wege for square profile M10 2 M10 4 7 L 20 3 For attaching pipes to ceilings an vertically to walls For connecting steel square section rails Galvanise With long threa coupling wele on Prouct material Exclue: Tension weges Steel Article no. Colour PU1 PU2 PU4 362.864.26.1 Galvanise / blue passivate 1 10 1100 For attaching pipes to ceilings an vertically to walls For fastening pipe brackets, suspension an connection elements on support rail For fastening to the PluviaFix support rail square profile Galvanise Prouct material Steel Article no. L Colour PU1 PU2 PU4 cm 362.865.26.1 9 Galvanise / blue passivate 1 100 21000 Pluvia Prouct an Installation Guie 2011 17
Prouct Guie Pluvia rail an fixing system PluviaFix pipe brackets with threae fastening PluviaFix pipe brackets with threae fastening PluviaFix pipe brackets with threae fastening PluviaFix pipe bracket for 250-315 pipe use with PluviaFix C profile support rail PluviaFix pipe anchor bracket set with sleeve M16 with fixe-point weling strip for C profile support rail, set with 2 pieces 250 M M l l L L B B For attaching pipes to ceilings an vertically to walls For fastening to the PluviaFix support rail C-profile For slie fastening of pipes For fastening with threae ros For attaching pipes to ceilings an vertically to walls For fastening to the PluviaFix support rail C-profile For fixe-point fastening of pipes For fastening with threae ros Galvanise Female threa Galvanise Female threa Prouct material Steel Prouct material Steel Fastening material Article no. Ø M B cm L cm l cm PU1 PU2 PU4 371.862.00.1 250 16 3 14,8 6 1 10 372.862.00.1 315 16 3 18 6 1 5 120 Pipe bracket; Fixe-point weling strip; Fastening material Article no. Ø M B L l PU1 PU2 PU4 cm cm cm 371.861.00.1 250 16 3 14,8 6 1 5 120 18 Pluvia Prouct an Installation Guie 2011
PluviaFix C profile track system for pipe iameters 250-315 Prouct Guie Pluvia rail an fixing system PluviaFix pipe anchor bracket set with sleeve M16 with fixe-point weling strip for C profile support rail, set with 2 pieces 315 PluviaFix suspension element for C profile M l L B For attaching pipes to ceilings an vertically to walls For fastening C profile support rails with threae ros M10 Galvanise Fastening material For attaching pipes to ceilings an vertically to walls For fastening to the PluviaFix support rail C-profile For fixe-point fastening of pipes For fastening with threae ros Galvanise Female threa Prouct material Steel Article no. PU1 PU2 363.862.00.1 1 50 PluviaFix connection element for C profile B H L 2 fixe-point weling strips; 2 pipe brackets; Fastening material Article no. Ø M B L l PU1 PU4 cm cm cm 372.861.00.1 315 16 3 18 6 1 24 PluviaFix C profile track system for pipe iameters 250-315 PluviaFix C profile track system for pipe iameters 250-315 PluviaFix C profile support rail For attaching pipes to ceilings an vertically to walls For connecting C profile support rails Galvanise Fastening material Article no. B H L PU1 PU2 cm cm cm 363.864.00.1 4,5 4 16 1 5 B H L(m) For attaching pipes to ceilings an vertically to walls For fastening pipe brackets with threa fastening M16 Galvanise C profile Article no. B H L (m) PU2 PU4 cm cm m m m 363.863.00.1 4 6 5 5 200 Pluvia Prouct an Installation Guie 2011 19
Prouct Guie Pluvia rail an fixing system Mounting plates Mounting plates Mounting plates Mounting plate, light with sleeve M8 / M10 M h H B a L For attaching pipe brackets to the builing structure For attaching pipes to ceilings an vertically to walls For slie fastening For attaching support rails to the builing structure Galvanise Female threa 2 fastening points Prouct material Steel Article no. M a B H h L Colour PU1 PU3 cm cm cm cm cm 362.848.26.1 8 / 10 5,5 3 1,9 0,3 8 Galvanise / blue passivate 1 50 Threae ro M10 For attaching pipe brackets to the mounting plate For fastening of support rails on mounting plate Male threa With protective shell PVC sleeve Article no. M L cm PU1 PU2 PU4 362.836.00.1 10 50 1 10 2000 20 Pluvia Prouct an Installation Guie 2011
Mounting plates Prouct Guie Pluvia rail an fixing system Support shells galvanise insie with black painte finish L(m) s Coate Galvanise Article no. Ø L (m) m PU2 m PU3 m PU4 m 360.850.00.1 40 3 3 30 361.850.00.1 50 3 3 30 3630 363.850.00.1 56 3 3 30 2550 364.850.00.1 63 3 3 30 2550 365.850.00.1 75 3 3 30 2400 366.850.00.1 90 3 3 30 1980 367.850.00.1 110 3 3 30 1500 368.850.00.1 125 3 3 30 1410 Pluvia Prouct an Installation Guie 2011 21
Prouct Guie Pluvia rail an fixing system Electrofusion tape for anchor bracket Electrofusion tape for anchor bracket Electrofusion tape for anchor bracket Electrofusion tape for anchor bracket D 1 h H For fixe-point fastening of pipes in conjunction with pipe brackets 1-section Can be wele with Geberit electrofusion machine Prouct material PE Article no. Ø 1Ø D cm H cm h cm Colour PU1 PU2 PU3 PU4 361.776.16.1 50 58 6,6 6 3 Black 1 10 40 1800 363.776.16.1 56 64 7,2 6 3 Black 1 10 40 1800 364.776.16.1 63 71 7,9 6 3 Black 1 15 60 1620 365.776.16.1 75 83 9,1 6 3 Black 1 10 40 1080 366.776.16.1 90 98 10,6 6 3 Black 1 8 32 864 367.776.16.1 110 118 12,6 6 3 Black 1 12 36 648 368.776.16.1 125 133 14,1 6 3 Black 1 8 24 432 369.776.16.1 160 168 17,6 6 3 Black 1 8 24 288 370.776.16.1 200 208 21,6 6 3 Black 1 5 10 700 371.776.16.1 250 258 26,6 6 3 Black 1 5 500 Electrofusion tape for anchor bracket D h 1 H For fixe-point fastening of pipes in conjunction with pipe brackets 2-section Can be wele with Geberit electrofusion machine Prouct material PE Article no. Ø 1Ø D H h Colour PU1 PU2 PU4 cm cm cm 372.776.16.1 315 323 33,1 6 3 Black 1 4 144 22 Pluvia Prouct an Installation Guie 2011
PluviaFix support sets Prouct Guie Pluvia rail an fixing system PluviaFix support sets PluviaFix support sets PluviaFix support set ø 75-160 PluviaFix support set ø 200 M M L L M M M M For aitional support of the PluviaFix fastening system uner unfavourable conitions For horizontal pipe fastening For installation uring pipe installation For subsequent installation For ø 75 pipes that are suspene more than 100 cm For ø 90-160 pipes that are suspene more than 60 cm For fastening to the PluviaFix support rail square profile Galvanise Articulate connection can be rotate through 180 For aitional support of the PluviaFix fastening system uner unfavourable conitions For horizontal pipe fastening For installation uring pipe installation For subsequent installation For pipes suspene more than 60 cm For fastening to the PluviaFix support rail square profile Galvanise Articulate connection can be rotate through 180 With securing clip Prouct material Steel Prouct material Steel Article no. Ø M L PU1 PU2 PU4 cm 365.710.00.1 75 10 12,4 1 10 366.710.00.1 90 10 13,3 1 10 367.710.00.1 110 10 14,4 1 10 180 368.710.00.1 125 10 15,1 1 10 280 369.710.00.1 160 10 17 1 5 Securing clip Article no. Ø M L PU1 PU2 cm 370.710.00.1 200 10 19 1 5 Pluvia Prouct an Installation Guie 2011 23
Prouct Guie Pluvia rail an fixing system PluviaFlex PluviaFix support set ø 250-315 PluviaFlex PluviaFlex M l PluviaFlex Pipe M M L L(m) D For aitional support of the PluviaFix fastening system uner unfavourable conitions For horizontal pipe fastening For installation uring pipe installation For subsequent installation For pipes suspene more than 60 cm For fastening to the PluviaFix support rail C-profile Galvanise Articulate connection can be rotate through 180 Prouct material Fastening material Steel Article no. Ø M L l PU1 cm cm 371.710.00.1 250 10 14,8 10,5 1 372.710.00.1 315 10 18 10,5 1 For flexible routing of negative pressure rainwater rains For use with Pluvia roof outlets 6 l an 12 l For pipe imensions ø 40-160 For pipes with a thermal loa between -10 an +50 C For use within builings For connecting rainwater outlet elements For flexible Pluvia connection pipes in imensions ø 40-75 For combination with tension resistant connection of pipes Not suitable for pipework in support shells Is not allowe to be use for Pluvia roof outlets 25 l - 100 l Can be connecte on both sies with electrowel sleeve coupling Cannot be shortene Article no. Ø D L (m) PU1 PU2 PU4 cm m 360.822.00.1 40 4,2 1,1 1 10 361.822.00.1 50 5,4 1,1 1 10 120 363.822.00.1 56 6,1 1,1 1 10 120 364.822.00.1 63 7 1,1 1 10 365.822.00.1 75 8,2 1,1 1 5 60 PluviaFlex fastening belt For flexible routing of negative pressure rainwater rains For use with Pluvia roof outlets 6 l an 12 l For pipe imensions ø 40-160 For pipes with a thermal loa between -10 an +50 C For use within builings For fastening the PluviaConnect connection pipe with horizontal installation close to the ceiling Not suitable for pipework in support shells Is not allowe to be use for Pluvia roof outlets 25 l - 100 l With pushbutton fastening Exclue: Fastening material Article no. PU1 PU2 358.004.00.1 1 5 24 Pluvia Prouct an Installation Guie 2011
PluviaFlex Prouct Guie Pluvia rail an fixing system PluviaFlex fixation set 6 4 4-7 5 14 For flexible routing of negative pressure rainwater rains For use with Pluvia roof outlets 6 l an 12 l For pipe imensions ø 40-160 For pipes with a thermal loa between -10 an +50 C For use within builings For attaching the outlet pipe up to ø 75 Not suitable for pipework in support shells Is not allowe to be use for Pluvia roof outlets 25 l - 100 l Galvanise Prouct material Steel Fastening material Article no. PU1 PU2 358.829.00.1 1 5 Pluvia Prouct an Installation Guie 2011 25
Prouct Guie Pluvia rail an fixing system PluviaFlex 26 Pluvia Prouct an Installation Guie 2011
Installation Guie Siphonic System Elements Guie Installation Guie All Geberit Pluvia rainwater systems in the UK an Irelan are installe by fully traine Approve Installers, who will prepare the final esign for the project an will check at all the construction stages shoul there be any variations to the esign that the system will operate siphonically using the Geberit Pro- Planner software. The Pluvia roof rainage system consists of: Pluvia roof outlets Geberit HDPE rainage system PluviaFix fastening system ProPlanner esign software 1. Siphonic System Elements 1.1. Pluvia Roof Outlets 1.3. PluviaFix Fastening System The Geberit Pluvia fastening system was evelope for the installation of horizontal pipework. Avantages of the rail system: Quick installation Fewer ceiling fastening points Controls thermal movement No expansion because of rigi installation No expansion sockets in the horizontal pipes Simple prefabrication is possible One fastening for anchor an sliing brackets The expansion an contraction of the pipework is prevente by the rail system as the properties of HDPE allows rigi fixing. Pluvia Rail 362.863.26.1 Threae Ro M10 Tension Wege 362.865.26.1 Geberit Pluvia outlets are evelope for all types of roof structures. Due to the ifferent ischarge rates of the outlets (6 l/s, 12 l/s or 25 l/s) an economical layout of the roof rainage system can be reache. The wie range of contact sheets an accessories allows connection to most roof finishes. 1.2. Geberit HDPE Drainage System Pluvia Bracket Connector to Rail 362.864.26.1 Fig. 1: Geberit PluviaFix Rail System Rail Clamp 362.862.26.1 1.4. Geberit ProPlanner Design Software The highly avance software package easily allows the calculation of the most complex roof projects. The Geberit HDPE range of pipes an fittings complements the Pluvia outlet to provie a total rainage solution. Geberit HDPE is available in iameters 40-315, an can be jointe in a variety of ifferent methos incluing electrofusion, butt weling an mechanical coupling. The outstaning material characteristics of Geberit HDPE allow specifiers an contractors to esign an pre-fabricate pipe runs away from the site of the installation. Pipe runs can be create in a safe, clean environment ensuring secure an accurate fabrication as well as consierable material an labour savings Manufacture to BS EN 1519: All pipe iameter 40 to 315 are available to at least PN 4 specification an are suitable to -800 mbar negative pressure Pipe in 200 to 315 iameters are also available to PN 3.2 specification an are suitable to -450 mbar negative pressure Fig. 2: Geberit ProPlanner Pluvia Prouct an Installation Guie 2011 27
Installation Guie Methoology for Designing the Pluvia System It offers istinct avantages: Convenient an very easy to operate Consierable time savings BBA approve Meets the BS8490 Coe of practice for siphonic systems Provies - Isometric rawings - Hyraulic calculations - Material list incl. fixing components - Cost calculation with reay to mail tener ocuments 2. Methoology for Designing the Pluvia System 2.1. Step 1 Determine the roof(s) rainage patterns 2.2. Step 2 Calculate the areas of roof(s) raining to each outlet 2.3. Step 3 Determine the rainfall intensity rate 2.3.1. Metho A Geberit recoen using 108 /hr (0.03 l/s per sqm). In the UK an Irelan this figure provies a frequent return rate for a 2 minute storm which ensures the systems self cleansing routine is activate. 2.3.2. Metho B Use the metho an ata provie in BS EN 12056 part 3. We o however avise against using the very high rainfall intensity rates that can be generate if long life spans for the builing an high safety factors (categories) are use in the calculations. Example: Project locate in Lonon requiring 25 year life span protection, Category 3 Safety Factor. This will result in a rainfall intensity rate of 236 /hr. In reality this will mean that once every 112.5 years for 2 minutes there may be a storm with a rainfall intensity of 236 /hr. Using this high rainfall rate will result in the systems pipework being massively oversize, which will result in the system not operating siphonically frequently, requiring a high level maintenance prograe to check for silt buil up in the pipes. Geberit recoen using the rainfall rate mentione in Metho A an allowing any potential higher rate rainfall to temporarily accumulate on the roof (for valley gutters this may require some over sizing of the gutter to provie aitional storage capacity). Example: If the 236 /hr protection is require, esign a primary system to cope with 108 /hr. Given: Require rainfall intensity rate: 236 /hr Recoen rainfall intensity rate: 108 /hr Require: Buil up from the excess over 2 minutes (1/30 hr) [] Solution: 236 -------- 108 -------- = 128 -------- hr hr hr 128 -------- 30 hr = 4.3 hr Buil up = 4.3 If the above mentione temporary storage metho is not acceptable then one of the three options below may be use: Option 1: Weir overflows in the parapet walls Option 2: A seconary siphonic overflow system Option 3: A separate internal overflow system (gravity) In all roof esigns an emergency / warning overflow must be provie to inicate a blockage within the system. 28 Pluvia Prouct an Installation Guie 2011
Installation Guie Choosing the Correct Pluvia Outlet 3. Choosing the Correct Pluvia Outlet 3.1. Outlet Series 3.1.1. Series 5 Outlets (6 l/s capacity) 3.1.3. Series 7+ Outlet (25 l/s capacity) Fig. 3: Series 5 Outlet Flow Rate On a flat roof or in a wie gutter (1 m min. with) 1.0-6.0 l/s In a narrow gutter (min. with 300 ) * 1.0-5.0 l/s * Narrow gutter must be at least 100 wier than outlet iameter 3.1.2. Series 7 Outlets (12 l/s capacity) Fig. 4: Series 7 Outlet Fig. 6: Series 7+ Outlet Flow Rate On a flat roof or in a wie gutter (1 m min. with) 8.0-25.0 l/s In a narrow gutter (min. with 420 ) * 8.0-20.0 l/s * Narrow gutter must be at least 100 wier than outlet iameter 3.2. Overflow Provision All roofs shoul have some provision of emergency overflow to protect the builing from unplanne buil-up of water on the roof or in the gutter. This can take form of: Weir overflows in the parapet wall or gutter ens Stan pipes through the roof or gutter ischarging via pipes to the groun Seconary gravity or siphonic system which incorporates an internal aaptor in the outlet which prevents water from entering the system until it reaches a epth of at least 55. This system can also ischarge at groun level (not connecte to the rainage system) ue to its infrequency of use plus to give an inication that the roof is flooing for some reason Geberit overflow aaptors can be installe in the Series 7 an Series 7+ type outlets. Series 5 outlets will nee to be raise on a plinth to restrict water flow until the esire height has been reache. Fig. 5: Series 7 Promenae Outlet On a flat roof or in a wie gutter (1 m min. with) In a narrow gutter (min. with 400 ) * With a horizontal spigot less than 100 from roof eck to centre of pipe * Narrow gutter must be at least 100 wier than outlet iameter Flow Rate 1.0-12.0 l/s 1.0-10.0 l/s 1.0-6.0 l/s Fig. 7: Geberit overflow aapter for Series 7 Fig. 8: Geberit overflow aapter for Series 7+ Pluvia Prouct an Installation Guie 2011 29
Installation Guie Connecting the Outlet to the Roof 4. Connecting the Outlet to the Roof Fig. 9: PVC Roof Finish Fig. 12: Steel Profile Roof Deck with Vapour Barrier Clamping Unit Fig. 10: Asphalt Roof Finish Fig. 13: Horizontal Outlet in a Gutter Min. 400 Fig. 14: Steel Gutter Outlet Fig. 11: Clamping Outlet in a Concrete Roof 30 Pluvia Prouct an Installation Guie 2011
Installation Guie Connecting the Outlet to the Roof Fig. 18: Timber Roof Construction Fig. 15: Concrete Roof (no Vapour Barrier) Fig. 19: Overflow Aapter Fig. 16: Concrete Roof (with a Vapour Barrier) Fig. 20: 25 Litre Outlet Fig. 17: Promenae Outlet Pluvia Prouct an Installation Guie 2011 31
Installation Guie System Installation Requirements 4.1. Connecting Various Roofing Materials to Outlets Geberit outlets are available in various forms: Fig. 21: All metal with a 500 square flange suitable for boning to liqui bitumen 5. System Installation Requirements 5.1. The Internal pipe work that makes up the siphonic system must follow the following rules All pipe work must be Geberit HDPE All horizontal pipe work must be lai level (no fall unless agree with Geberit) All horizontal pipe work joints must be either butt wele or electrofusion wele (no mechanical or seal ring joints) Vertical pipes may be either wele or seal ring jointe Horizontal pipes must be restraine to prevent thermal movement preferably with the Geberit Rail System Fig. 22: All metal with a 20 wie lip for weling to gutter Fig. 23: Clamping ring version to accept waterproof sheet hel mechanically All vertical seal ring fittings if use must be anchore with a suitably strong bracket (12 stu) All pipe iameters must follow the esign create by the Geberit ProPlanner software an to checke at all changes in pipe route by the Geberit Approve Installer before final sign-off All changes in irection or branch connection must be mae using 45 egree fittings. The only exception to this is ieiately below the outlets where a 90 egree ben may be use Fig. 24: With 'clamp in' foils of numerous material to suit a large number of roofing membrane types Only one reuction in pipe iameter is permitte at the top of the main vertical rop if the software permits it Fig. 25: Series 5 an Series 7+ metal outlets are also suitable for hot applie mastic asphalt resse into the bowl 32 Pluvia Prouct an Installation Guie 2011
Installation Guie System Installation Requirements 5.2. Horizontal Pipe Work Bracketing Detail Fig. 26: Geberit Rail System Metho Pipe bracket spacing With shells Without shells Pipe iameter [] RA [m] RA [m] 40 1.0 0.8 50 1.2 0.8 56 1.2 0.8 63 1.2 0.8 75 1.6 0.8 90 1.3 0.9 110 1.6 1.1 125 1.8 1.2 160 2.4 1.6 Fig. 27: Conventional Bracketing Metho 33 Pluvia Prouct an Installation Guie 2011
Installation Guie System Installation Requirements 5.3. Methos of Creating Fixe an Sliing Supports 5.3.1. Horizontal Expansion joint For spacing between guie brackets see table Max. 5 m Fig. 28: Using Geberit PluviaFix Rail System Expansion joint 5.3.2. Horizontal or Vertical Fig. 30: Using Expansion Joints Anchor Point with Electrowel Tape Fittings must be strong enough to resist forces of thermal expansion (See HDPE Installation Guie for ata) Max. 5 m Sliing brackets For spacing between guie brackets see table Fig. 29: Using Conventional Fixing 5.3.3. Vertical Instruction for expansion joint metho The following conitions are important to ensure perfect an easy assembly of the sleeve: Chamfering the inserte pipe en to approximate 15 Check the scale on the outer surface of the expansion socket for insertion epth Mark the correct insertion epth on the pipe Lubricate the pipe en well with soft soap, silicone or vaseline. N.B. Do not use oil or grease which can amage the rubber seal Anchor Point with Electrowel Tape Fig. 31: Rigi Fixing Fittings must be strong enough to resist forces of thermal expansion (See HDPE Installation Guie for ata) Table 1: Diameter [] Vert. [m] Table A 32 40 50 56 63 75 90 110 125 160 200 250 315 1.2 1.2 1.2 1.5 1.5 1.5 2.0 2.0 2.0 2.0 2.0 3.0 3.0 34 Pluvia Prouct an Installation Guie 2011
Installation Guie PluviaFlex System an Alternative Approach to Installing Pipe Work 5.4. Siphon Break Methos At the point where the siphonic system connects to the gravity rain the siphonic action must be stoppe. This is achieve by oubling the cross sectional area of the pipe bore (point A) using one of the methos show below. The gravity rain (B) must be size to accept the flow without surcharging. 6. PluviaFlex System an Alternative Approach to Installing Pipe Work The PluviaFlex system has been evelope to offer an alternative metho of installing the horizontal pipe work without using fixe anchor points or rigily fixing the system to prevent thermal movement. The flexible hose will allow the pipe work to expan an contract within limits. Fig. 32: Metho 1: Below Floor Slab Fig. 37: PluviaFlex System General information on the PluviaFlex system The installation temperature must be between -10 C an +50 ºC. (The change in length of the PE materials has been taken into account in the esign of the PluviaFlex components with a corresponing Δt) Fig. 33: Metho 2: Above Floor Slab Fig. 34: Metho 3: After Seale Access in Manhole Support shells an insulation against conensation may not be use with the PluviaFlex system. (These woul negatively affect the necessary sliing effect) The length of straight pipelines may only be max. 50 m Each ownpipe of the PluviaFlex system must be equippe with a fixe point at the irection of change or after the iverting zone area No fixe points may be installe in the entire system (except for ownpipe) Fig. 35: Metho 4: Minimum Distance before Manhole Fig. 36: Metho 5: Open Pluvia Systems are not permitte Pluvia Prouct an Installation Guie 2011 35
Installation Guie Technical Data 7. Technical Data 7.1. Outlet Types Series Min. flow capacity Max. flow capacity Discharge capacity (outlet in gutter) Outlet spigot iameter [l/s] [l/s] [l/s] [] Series 5 Outlet (Small) 1 6 1-5 56 Stanar Series 7 Outlet 1 12 1-10 56 High Capacity Series 7+ 8 25 20 90 7.2. Design Parameters Min. pipe iameter 40 Max. pipe iameter 315 Min. flow velocity 0.7 m/s Min. water to air ratio 60 % Max. negative pressure 40-160 (PN4)* - 800 mbar Max. negative pressure 200-315 (PN3.2)* - 450 mbar Max. negative pressure 200-315 (PN4)* - 800 mbar Min. 2 outlets to be installe on a system Emergency warning overflows must be provie on all roofs Pluvia outlets shoul be space no further than 20 m apart Pluvia outlets shoul be space no further than 10 m from en of gutter All horizontal pipes must be lai level (no graient) 7.3. PluviaFix Rail with Full Pipe Weights Pipe iameter Pipe weight full Rail weight an bracketry Total weight [] [kg/m] [kg/m] [kg/m] 40 1.24 2.34 3.58 50 1.94 2.10 4.04 56 2.34 2.10 4.44 63 3.09 2.10 5.19 75 4.83 2.16 6.99 90 6.31 2.08 8.39 110 9.42 2.06 11.48 125 12.17 2.09 14.26 160 19.95 2.14 22.09 200 31.16 2.13 33.29 250 48.68 4.10 52.78 315 77.23 4.13 81.36 36 Pluvia Prouct an Installation Guie 2011
Installation Guie Testing of System 7.4. Pluvia Rail Fastening System Dimensions Pipe iameter Bracket [] [] A B C D E F 40 133 110 23 71 154 50 141 113 28 75 162 56 147 116 31 81 168 63 157 122 35 89 178 75 169 128 41 101 190 90 185 137 48 115 206 110 206 148 58 136 227 125 221 155 66 152 242 160 257 174 83 190 278 200 297 194 103 233 318 250 351 223 128 336 373 315 416 255 161 402 438 9. Maintenance Maintenance of System Geberit recoen that a maintenance prograe is always implemente on completion of the project. The intervals between inspection will epen on the location of the builing. The maintenance prograe shoul inclue: 1 2 Clean all outlets of any ebris or silt Remove li M10 rop ro PluviaFix bracket PluviaFix Rail Tension wege 3 Remove function isc HDPE pipe B C F b A Fig. 38: Guie brackets on rail 40-200 E D 4 Rinse function isc with water 40 PluviaFix rail M10 rop ro B C HDPE pipe F A 5 Wipe outlet with cloth D E PluviaFix support bracket Fig. 39: Guie brackets on rail 250-315 8. Testing of System On completion of a Geberit Pluvia system the integrity of all joints must be teste using an air test as escribe in BS EN 12056, which in general requires a 38 air test for 3 minutes If the installation has been esigne using the Geberit software it is not normally necessary to performance test the installation. Thir party approval by the BBA inclue verification that the software is a true reflection of the actual flow performance. 6 7 Check that no pipes connecting to outlets are blocke with silt etc., if blockages are foun they can be remove by using a water jet through the outlet after removing the li an function isc as shown above Ensure all outlets have gratings an tops in place. Orer spares from Geberit if necessary Pluvia Prouct an Installation Guie 2011 37
Installation Guie Maintenance 38 Pluvia Prouct an Installation Guie 2011
Numerical inex Article no. Page 240.008.00.1 9 240.231.00.1 12 240.232.00.1 12 240.236.00.1 12 240.237.00.1 12 240.238.00.1 12 240.239.00.1 11 240.240.00.1 11 240.241.00.1 11 240.242.00.1 9 240.647.00.1 9 358.004.00.1 24 358.007.00.1 9 358.008.00.1 14 358.010.00.1 5 358.012.00.1 10 358.013.00.1 9 358.829.00.1 25 359.003.00.1 4 359.012.00.1 13 359.027.00.1 14 359.029.00.1 5 359.500.00.1 3 359.510.00.1 4 359.511.00.1 4 359.512.00.1 4 359.514.00.1 3 359.543.00.1 14 359.544.00.1 13 359.550.00.1 8 359.551.00.1 6 359.552.00.1 11 359.553.00.1 11 359.554.00.1 9 359.555.00.1 9 359.556.00.1 9 359.558.00.1 10 359.560.00.1 10 359.561.00.1 12 359.562.00.1 7 359.563.00.1 6 359.565.00.1 8 359.566.00.1 12 359.567.00.1 12 359.568.00.1 10 359.571.00.1 6 359.573.00.1 13 359.575.00.1 10 359.577.00.1 10 359.578.00.1 10 359.579.00.1 10 359.631.00.1 11 359.635.00.1 9 359.636.00.1 7 359.637.00.1 7 359.638.00.1 7 Article no. Page 360.822.00.1 24 360.850.00.1 21 360.861.00.1 15 361.776.16.1 22 361.822.00.1 24 361.850.00.1 21 361.861.00.1 16 362.836.00.1 20 362.848.26.1 20 362.862.26.1 17 362.863.26.1 17 362.864.26.1 17 362.865.26.1 17 363.776.16.1 22 363.822.00.1 24 363.850.00.1 21 363.861.00.1 16 363.862.00.1 19 363.863.00.1 19 363.864.00.1 19 364.776.16.1 22 364.822.00.1 24 364.850.00.1 21 364.861.00.1 16 365.710.00.1 23 365.776.16.1 22 365.822.00.1 24 365.850.00.1 21 365.861.00.1 16 366.710.00.1 23 366.776.16.1 22 366.850.00.1 21 366.861.00.1 16 367.710.00.1 23 367.776.16.1 22 367.850.00.1 21 367.861.00.1 16 368.710.00.1 23 368.776.16.1 22 368.850.00.1 21 368.861.00.1 16 369.710.00.1 23 369.776.16.1 22 369.861.00.1 16 370.710.00.1 23 370.776.16.1 22 370.861.26.1 16 371.710.00.1 24 371.776.16.1 22 371.861.00.1 18 371.862.00.1 18 372.710.00.1 24 372.776.16.1 22 372.861.00.1 19 372.862.00.1 18 Pluvia Prouct an Installation Guie 2011 39
Geberit Sales Lt Geberit House Acaemy Drive Warwick Warwickshire CV34 6QZ T 0800 077 8365 F 0844 800 6604 Eire +44 (0)1926 516 800 Literature 0800 007 5133 www.geberit.co.uk Subject to change without notice. The information in this ocument contains general escriptions of the technical options available, which o not always have to be present in the iniviual cases. The require features shoul therefore be specifie in each iniviual case at the time of closing the contract. Geberit, August 2011.