LS-101 LAN to Serial Device server. User s Manual



Similar documents
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

One Port Serial Server Users Manual Model ESP901, ESP901E

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

2012 uptimedevices.com

IP SERIAL DEVICE SERVER

MODBUS TCP to RTU/ASCII Gateway

MODBUS TCP to RTU/ASCII Gateway. User s Manual

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

INTRODUCTION FEATURES OF THE ICM

RS-232 COMMUNICATIONS

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

VSCOM USB PRO Series Industrial I/O Adapters

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

NPort s Ethernet Modem Mode

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

RS-232/422/485, Power over Ethernet

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

AXIS 205 Network Camera Quick Installation Guide

Using HyperTerminal with Agilent General Purpose Instruments

EMG Ethernet Modbus Gateway User Manual

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) Manual Rev A + - DLM CTS RTS DTR DSR

Operation Manual of EX-9132C-2. Serial to TCP/IP Converter

T3 Mux M13 Multiplexer

Serial Over IP Ethernet Device Server

Technical Note #14. Phone Modem Device Support. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home

Accessing Diagnostics using a Dialup Modem

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

2-Port RS232/422/485 Combo Serial PCI Card

Advanced Data Capture and Control Systems

TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

Connecting and Setting Up Your Laptop Computer

Serial-Ethernet Server STE-501C. User s Manual

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

Single channel data transceiver module WIZ2-434

Application Note. Terminal Server G6

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide

Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP.

CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program

isco Connecting Routers Back to Back Through the AUX P

NPort DE-311 Hardware Installation Guide

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

INSTALLATION AND OPERATION MANUAL CNFE2DOE TERMINAL SERVER

Industrial Multi-port Serial Cards

1-Port R422/485 Serial PCIe Card

Atop ABLELink Ethernet-Serial Server GW51C- MAXI

Follow these steps to prepare the module and evaluation board for testing.

Table of Contents. Creating a VC1000 Network... 3

LBNP RS-232/485/422 serial device server. User manual

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System

How to setup a serial Bluetooth adapter Master Guide

UDS10 UDS100 User Guide

Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount)

WHQL Certification Approval...2 User Interface K software FIFO 4 Universal PCI Interface...5 Ready for 64-bit System...5

Serial over Ethernet Device Server. User s Manual

Cable Specifications and Information

HWg-STE HWg-STE PoE MANUAL

RS232/485 TCP/IP converter TPC2RS. Ver. 01A- GB

Modbus Communications for PanelView Terminals

Connecting the Console Port to a PC

xpico User Guide Part Number Revision A April 2012

PCMCIA 1 Port RS EDITION OCTOBER 1999

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

UPS Network Interface. Quick InstallationGuide

First Steps. Remote Access Gateway IGW/922. with DIL/NetPC ADNP/9200

Internet-bridge XPort

Chapter 10 Troubleshooting

User Manual Network Interface

LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION

EZL-50L User s Manual

Computer Networks I Laboratory Exercise 1

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Connecting the DG-102S VoIP Gateway to your network

MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

F2103 GPRS DTU USER MANUAL

EZ-View Network Communications Guide

Cable Pinouts. SRP I/O Module

Debugging Network Communications. 1 Check the Network Cabling

Date Rev. Details Author

How To Set Up A Modbus Cda On A Pc Or Maca (Powerline) With A Powerline (Powergen) And A Powergen (Powerbee) (Powernet) (Operating System) (Control Microsci

Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide

Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide

Why you need to monitor serial communication?

UDS1100 User Guide Part Number Revision B June 2006

Cabling Guide for Console and AUX Ports

SyncLink GT2/GT4 Serial Adapter

LOW COST GSM MODEM. Description. Part Number

FINS Gateway For OMRON PLCs

XPort Device Server User Guide

User Manual. NetCom PRO/WLAN. Edition: April 2012

Voice Over Internet Protocol (VoIP) Configuration

Dominion KX II-101-V2

Transcription:

LS-101 LAN to Serial Device server User s Manual

Revision History Revision No Date Author Remarks 0.1 August 29, 2001 IDC Initial document

INTRODUCTION Overview Almost all instruments and most industrial equipment support a serial port (called the craft port) that is primarily used to program the device. In a typical scenario, the user takes a laptop to the device and through custom software, programs the device or the instrument. Being able to control and program instruments remotely through the LAN or the Internet is very desirable and has obvious advantages. The LS-101 device server does precisely that. The LS 101 connects the serial devices to the Ethernet. With the full-featured serial handshake signals and 10/100 Base T-network interface it is now easy to network enable any device that has serial port. Features?? Internet enables any device that has serial port?? Use existing software?? TCP/IP, ICMP, HTTP and DHCP Protocols supported?? Automatic 10/100-BaseT selections?? Communicate only with Trusted systems?? Configuration is protected with the password?? Baud rates up to 230.4Kbps?? Data size 7 or 8?? Stop bits 1 or 2?? Parity Odd or Even or None?? Flow control Hardware, XON/XOFF, none?? Easy configuration?? Modem mode of operation?? Diagnostic LED indicators?? Compact size (3.4 X 2.3 X 0.9 inches)?? Operating temperature -10 to 65 C Applications?? SCADA (Supervisory Control And Data Acquisition)?? Vending machines?? Energy management?? Test Instrumentation

?? Cable set-top boxes?? Credit card terminals?? POS Terminals?? CNC Machines?? Security Systems?? Medical Industry

Packing List: With the LS 101, please verify that you have received: 1. LS-101 Unit 2. RS232 Cable 3. User Manual 4. Power adapter 5. Configuration Software Disk

Getting Started LS-101 Connect Collision Link100 Link10 Duplex Link Power Error Serial Connector LED s Description LED name Description Connect TCP/IP connection has been established with the server. Collision Collision occurred on the Ethernet Link-100 Link-100 Activity Link-10 Link-10 Activity Duplex Glows when the Ethernet Link is operating in Full Duplex mode Link Ethernet Link status Power LED Power supply Error Error occured DIP Switch settings are read only at the power on. DIP Switch Settings: - Switch 4 Switch 3 Switch 2 Switch 1 Mode of operation X OFF OFF ON Configuration Mode ( RS232) OFF OFF ON OFF LAN to Serial (Bi-directional) ( RS232) ON OFF ON OFF LAN to Serial (Bi-directional) ( RS485) OFF ON OFF OFF Modem mode ( RS232) ON ON OFF OFF Modem mode (RS485) ON ON ON ON Load factory defaults. Note:- Since it erases the user configuration, please use this mode in caution.

The LS-101 can operate in three modes (DIP switch selectable) of operation. Please refer to chapter on Configuration. 1. Configuration Mode 2. LAN to Serial converter 3. Modem mode All the operating modes are described below: LS-101 can also be configured through the web browser. First we need to configure the LS 101. Configuration Mode of Operation In this mode we configure the LS-101. Please set the switches as indicated below for Configuration Mode. DIP Switch Settings:- Switch 4 Switch 3 Switch 2 Switch 1 Mode of operation OFF OFF OFF ON Configuration Mode In this mode, the serial port parameters are set to 9600-baud 8N1. Installation Set the LS-101 to the Configuration mode using the Dipswitch as indicated above. Connect the serial port of the system to the LS-101 as shown in the figure below. Power on the LS-101. In the configuration mode the LS-101 serial port parameters are set to 9600, 8, n, 1. Serial LS-101 Fig. Configuring the LS-101. The LS-101 can be configured using IDC supplied configuration program LS101.exe or using any Terminal Emulation program ( Hyperterminal).

For proper operation the following parameters must be set: LS-101 Parameter Factory Default Description IP Address 192.168.002.020 IP address of the LS-101 Server Port 5000 Listening port on LS-101 Subnet mask 255.255.255.0 Subnet mask of the LS-101 Gateway 192.168.002.001 Gateway of the LS-101 DHCP Disabled Enable/Disable the DHCP. i.e. Automatically obtain the Ethernet parameters from the server. Trusted Systems Feature Trusted Systems IP addresses list Remote Server feature Disabled Any system on the network can communicate with the serial device. If Enabled, Communication is permitted with any of the trusted Systems. 0.0.0.0 Allow TCP/IP connections to only these systems. Disabled If Remote Server feature is Disabled AND there is NO Client connected to LS-101, data received on the RS-232 port is discarded. If Remote Server feature is enabled AND there is NO Client connected to the LS- 101, data received on RS-232 port is sent to one of the Remote servers at the specified port. Remote Server IP addresses list 0.0.0.0 The IP address of the system to which this LS-101 has to make the connection Baud rate 9600 Serial port baud rate Data size, Parity and 8 N 1 Serial port Data size, parity and stop bits stop bits Flow control None Serial port Handshaking control Password IDC Used to protect the configuration Configuring LS-101 through the LS101.exe Set the Serial port parameters to 9600, 8, n, 1. Power on the LS-101. The LS-101 displays the Sign-on message and prompts the user to enter the password as IDC. IDC, Inc. LAN to Serial Device Server LS-101 Firmware Version 1.0 Feb 12 2002 Enter the Configuration Password:

Once the correct password is entered, the LS-101 will displays the current LAN and serial parameters set in the EEPROM and main configuration menu as shown below LS-101 IP address =192.168.002.020. Server Port number = 05000 Subnet mask =255.255.000.000. Gateway Address =192.168.002.001. DHCP Disabled Trusted Systems Feature Disabled Remote Server feature Disabled Serial Host Baud rate=9600 Serial Data, Parity, Stop bits=8 N 1 Serial Flow control=none A. Set IP address B. Set Subnet mask C. Set Gateway D. Enable/Disable DHCP E. Enable/Disable Trusted Systems feature F. Trusted Systems IP addresses G. Enable/Disable Remote Server feature H. Remote Servers IP addresses I. Set Host Baud rate J. Select Data size, Parity, Stop bits K. Select the Flow Control L. Set Configuration Password M. Display current parameters N. Save to EEPROM Enter the choice: Select the choice and set the LS-101 LAN/Serial parameters appropriately. After all the parameters are set select the choice L to save the parameters to the EEPROM on the LS-101. Set the DIP switch (Table 1) to the desired mode of operation Power off and ON the LS-101. Power on the LS-101 will read the DIP switch, EEPROM for serial and LAN parameters and operate accordingly. For simple check use ping <LS-101 IPADDRESS> command.

LAN to Serial Mode In this mode of operation the data is transferred from LAN to serial and vice versa in a transparent mode. To select this mode, please set the DIP switch position as shown:- DIP Switch Settings: - Switch 4 Switch 3 Switch 2 Switch 1 Mode of operation OFF OFF ON OFF LAN to Serial (Bi-directional) The fig.1. Describes the existing scenario. The Serial Software running on the server will read/write to its serial port (COM1/2 ) to communicate with the serial device. Serial Instrument PC Fig. 1. Existing scenario Internet/LAN enable the serial device by using two LS-101 s (operating in the LAN to Serial mode of operation) as shown in the fig. 2. Use the same software and communicate with the serial device seamlessly. In this scenario the serial device can be accessed or controlled through remotely over Internet or LAN. Serial LAN Inter LS-101 LAN LS-101 Serial net/ (A) (B) LAN Remote PC Instrum ent Fig. 2. Internet/LAN enable the serial device (Server running serial software)

Using the network software communicate with the serial device as shown in the following fig. LAN Internet/ LAN Serial LS-101 LAN Instrume nt PC Fig 3. Internet/LAN enable the serial device (Server running Network software) Modem Mode of Operation In this mode of operation the LS-101 emulates a dial up modem. For transparency to existing software, the LS 101 accepts modem AT commands. These commands are listed in Table 1. The DIP switch is set as shown DIP Switch Settings: - Switch 4 Switch 3 Switch 2 Switch 1 Mode of operation OFF ON OFF OFF Modem mode Internet/ LAN Ethernet LS-101 In Modem Mode Serial Instrument Fig2. Modem mode of operation. The LS-101 is always in one of two states; the command state or the on-line state. Command State The LS-101 assumes the command state whenever power is applied. This state allows the LS-101 to be configured for the particular application. In the command state the data received from the serial port is treated as commands and responses are sent back. LS-101 operation is controlled by AT commands Table 1. On-line State The command ATD<IP address> is used to connect to the remote server. Once the connection is established LS-101 send CONNECT response to the serial device. The LS- 101 will enter into the on-line state i.e. what ever data received through the serial port is

sent to the LAN and vice versa. You can switch into the command mode by using the escape sequence +++. Modem mode Command Reference Command Guidelines Carriage Return (CR) The command line must end with a carriage return. The LS-101 will not begin to execute the command until it receives a CR. Attention Code Command lines must begin with the characters AT. A/ Command The A/ Command instructs the LS-101 to repeat the last successful command line stored in the buffer. A/ may be used to reconnect the previous server when busy condition is encountered. A/ is used in place of AT and no carriage return is required. Backspace Key Prior to pressing carriage return, editing can be done with the backspace key. Result Codes Result codes are responses by the LS-101 to commands. Result codes may be English words or digits. Unimplemented AT commands If an unimplemented command is entered, no action is taken by the LS-101 and ERROR result code is issued. Escape Code Sequence The three-digit escape code sequence forces the LS-101 to the command state from the on-line state. The escape code sequence is +++. Result codes Digit Code Word Code Meaning 0 OK Command Line Executed without errors 1 CONNECT Connected to the server 2 RING Some server is trying to connect to the LS-101 3 NO CARRIER Connection lost 4 ERROR Invalid command, error in command line 7 BUSY Unable to connect to remote host (server)

AT Commands Command Facory Default Parameters/Description AT Attention Code. AT is the command line prefix (Attention code). AT Precedes the command line except for +++(escape) and A/ (repeat) commands. Parameters:- None A Answer command. A forces the LS-101 to go to auto answer mode. A/ Repeat Last Command. A/ repeats the previous command D[S=x]<Ipaddress> Dial Command. D causes the LS-101 to connect to the remote host (server) with the IP address that follows. Valid characters are 0-9,. Optional S=x (x = 0, 1, 2, 3) causes the LS-101 to establish connection with stored IP address servers. En N = 1 Off-line Echo Character Option. En controls command echo to the host Parameters: n = 0, 1 N = 0 Disables echo N = 1 Enables echo (factory default) Fn N = 1 On-line Echo Character Option. Fn determines whether characters are echoed to the host from the LS-101 in the on-line state. Parameters: n = 0, 1 N = 0 Enables echo N = 1 Disables echo (factory default) Hn N = 0 Connect control option. Hn controls the connection to the host. Parameters: n = 0 N = 0 Disconnect the TCP/IP connection In N = 3 Identification/Checksum Option. In interrogates the LS-101 for its product identification Parameters: n = 3 N = 3 IDC LS-101 Rev 1.0 O On-line Command. O forces the LS-101 to the on-line state from the command state. When the LS-101 is in the on-line state, it will return to the command state upon receipt of the escape code. Qn N = 0 Result Code Display Option. Qn enables the modem to send result codes.

Parameters: n = 0, 1 N = 0 Enables the return of result codes (factory default) N = 1 Disables the return of result codes (Quiet) Vn N = 1 Result Code Form Option. Vn determines the type of result code Parameters: n = 0, 1 N = 0 Result code is sent as digits N = 1 (short form) Result code is sent as words (long form Or verbose) (factory default) Zn N = 0 Recall Stored Profile Option. Zn causes the LS-101 to fetch the stored configuration from non-volatile memory and store it in the active configuration area. An OK result code is returned. Parameters: n = 0, 1 N = 0 Recall stored profile 0 (previously Stored with &W0) (factory default) +++ Escape Code Sequence. The escape code sequence forces the modem to the command state from the on-line state. It consists of a three-character escape code sequence surrounded by escape guard times. The delay between issuance of each escape character must not exceed the escape guard time. The escape guard time is defined as the time delay required between the last character transmitted and the first character of the escape code. The guard time is 1 Second and the escape character sequence is +++. The escape character must be entered three consecutive times. To enter the escape code sequence perform the following:- WAIT AT LEAST 1 SECOND (After the last character has been transmitted) Enter: +++ ( Delay less than one second between characters) WAIT AT LEAST 1 MORE SECOND ( Before transmitting another character). The LS-101 returns to the local command state and sends the OK result code. The LS-101 will not disconnect the TCP/IP connection until it receives an ATH command. The ATO command will make the LS-101 to go back to

on-line state. &Dn N = 0 Data Terminal Ready Option. &Dn controls the Data Terminal Ready (DTR) options. Parameters: n = 0, 2 &V &Zn=x N = 0 N = 2 LS-101 ignores DTR (factory default) LS-101 disconnects the TCP/IP Connection and assumes the Command state when DTR is de- Activated. View Active Configuration and User Profiles. The active and stored profiles are displayed along with the stored IP addresses. Store IP Address. &Zn stores upto four IP addresses into the NVRAM for later recall by the DS dial stored number command. Parameters: n = 0, 1, 2, 3 X = <IP ADDRESS> Example:- AT&Z1=10.0.0.121 <CR> ATDS=1<CR>

The LS-101 serial port (DB25 Female connector) is wired as DCE. Pin No. Signal Name Input/Output 2 TXD Input 3 RXD Output 4 RTS Input 5 CTS Output 6 DSR Output 7 GND 8 DCD Output 20 DTR Input Remaining Pins are NC (Not connected) The LS-101 serial port (DB9 Female connector) is wired as DCE. Pin No. Signal Name Input/Output 1 DCD Output 2 RXD Output 3 TXD Input 4 DTR Input 5 GND 6 DSR Output 7 RTS Input 8 CTS Output 9 RI Output RS-485 related Jumpers JP1, JP2 and JP3 near the RS485 connector JP1 Short Insert a 620 Ohm resistor between GND and RS485 Signal B (Pull-down resistor) Open Remove a 620 Ohm resistor between GND and RS485 Signal B (Pull-down resistor) JP2 Short Insert a 120 Ohm resistor between RS485 Signals A and B (Terminating resistor) Open Remove a 120 Ohm resistor between RS485 Signals A and B (Terminating resistor) JP3 Short Insert a 620 Ohm resistor between Vcc and RS485 Signal A (Pull-up resistor) Open Remove a 620 Ohm resistor between Vcc and RS485 Signal A (Pull-up resistor)

Frequently Asked Questions (FAQs):- 1. Where can I use the LS-101? Ans. As a bi-directional LAN to serial converter, the LS-101 can be used to Net enable any instrument/device that has a serial port. With the LS-101 installed, all such devices can now be monitored and controlled remotely. 2. What are the Ethernet features supported? Ans. LS-101 supports auto detection of 10/100 Mbps link, Half/Full duplex, auto negotiation. Visual indicators are provided for Link, Full Duplex, Link 10-Activity, Link-100 Activity, and Collision. 3. What are the Ethernet standards supported? Ans. LS-101 supports IEEE 802.3/802.3u and 802.3u clause 28. 4. Which Internet protocols are supported? Ans. LS-101 supports TCP/IP, ICMP, DHCP, ARP 5. Can I Ping the LS-101? Ans. Yes. LS-101 supports ICMP for these purposes. 6. What is the Ethernet (MAC address) of the LS-101? Ans. The Ethernet (MAC Address) of every LS-101 is printed on the LABEL. The Ethernet (MAC Address) will start with 00-07-91. 7. Any security features incorporated? Ans. LS-101 supports two security features. 1. Configuration Password, 2. Communicate only with the Trusted systems. 8. What is a trusted system? Ans. A trusted system is an IP address that is authorized to communicate with LS- 101. Communication with other IP addresses server is ignored. 9. I have a different requirement, will IDC be able to support? Ans. Definitely. For custom design and features, please contact IDC.