ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt



Similar documents
LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Operating Manual A-ISOMETER IR1575PG1

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

RM4TG20 three-phase network control relay RM4-T - range V

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Manual ISOMETER IRDH575

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

48 SERIES Relay interface modules 10 A

Electronic overload relay EF19 and EF45

Operating Manual EDS3090. Portable insulation fault location system for energised and deenergised systems Software version: D316 V1.

Duct Humidity Transmitter

Safety technique. Emergency stop module BO 5988 safemaster

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Electronic overload relay EF65, EF96 and EF146

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Preset Counter signo 721

Quick Connect. quick - simple - efficient.

Thermistor motor protection

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

E-STOP relays, safety gate monitors

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

E-STOP relays, safety gate monitors

Contact expansion modules

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Catalog. Modular DIN rail components Installation contactors

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

SKR - industry relay

Type: DILM50(230V50HZ,240V60HZ) Article No.:

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

E-STOP relays, safety gate monitors

ABB i-bus KNX SA/S Switch Actuators Product Manual

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Contact expander modules

Type: DILM32 10(24V50HZ) Article No.:

Pluggable interface relays CR-P Pcb relays

Type: DILM9 10(24VDC) Article No.:

E-STOP relays, safety gate monitors

Charge Controller CC611/CC612 Preliminary datasheet

Modular I/O System Analog and Digital Interface Modules

PHOENIX CONTACT Features

Voltage Regulator SPAU 341 C. Product Guide

Analog signal converters CC-E I/I Current / current isolators

PNOZsigma - Base units

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

E-STOP relays, safety gate monitors

Three-phase monitoring relay CM-PFE

38 Series - Relay interface modules A

49 Series - Relay interface modules A. Features

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Digital input modules

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

38 Series - Relay interface modules A

DLP-PU/E Instruction Manual

Thyristor-controlled power supplies and battery chargers

60 Series - General purpose relays 6-10 A. Features

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

NC-12 Modbus Application

13 SERIES. Electronic step relays A

Technical catalogue. Modular DIN rail components Installation contactors

40 Series - Miniature PCB/Plug-in relays A. Features

Energy Management Energy Meter Type EM23 DIN

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

R.C.C.B. s two-pole LEXIC

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Relés e Contatores de Estado Sólido SIRIUS

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

GAE953 Electrical Alarm Unit 19" with Indicator

SINEAX U553 Transducer for AC Voltage

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Contents. Document information

Digital Pressure Measuring Instrument MDR480

J TB/TW Temperature limiter, temperature monitor

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Actuator-Sensor-Interface

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Installation manual. Generator Paralleling Controller GPC multi-line C

HERZ-Thermal Actuators

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

MasterINTERFACE 39 Series - Relay interface modules

ABB i-bus KNX Switch Actuators SA/S Product Information

Thermal-Magnetic Circuit Breaker M1-..

Transcription:

Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt TDB106015en/05.2013

Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) ISOMETER IRDH275 Device features Insulation monitoring for unearthed AC, AC/DC systems 0 793 V, DC 0 650 V Nominal voltage extendable via coupling device Two separately adjustable response values1 kω 10 MΩ AMP Plus measurement method Automatic adaptation to the system leakage capacitance Info button to display device settings and system leakage capacitance Self monitoring with automatic alarm Automatic self test, selectable Connection for external kω indication Test and reset button External test/reset button can be connected Two separate alarm relays with two potential-free changeover contacts N/O or N/C operation, selectable Backlit LC display RS-485 interface Approvals Product description The ISOMETER of the IRDH275 series is designed to monitor the insulation resistance of unearthed main circuits (IT systems) AC, AC/DC 0 793 V resp. DC 0 650 V. The AMP Plus measurement method meets the particular requirements of modern power supplies which often include rectifiers, converters, thyristor-controlled DC drives and directly connected DC components. In these systems often high leakage capacitances against earth occur due to interference suppression measures. The IRDH275 automatically adapts itself to the existing system conditions. In combination with a coupling device, the devices can also be used for higher voltages. An external supply voltage allows de-energised systems to be monitored too. For door mounting into distribution panels, refer to type IRDH375(B). Application AC, DC or AC/DC main circuits AC/DC main circuits with directly connected DC components, such as rectifiers, converters, and thyristor-controlled DC drives UPS systems, battery systems Heaters with phase control Installations including switch-mode power supplies IT systems including high leakage capacitances Coupled IT systems Function When the insulation resistance between the system conductors and earth falls below the set response value, the alarm relays switch and the alarm LEDs light up. Two separately adjustable alarm relays allow to distinguish between prewarning and alarm. The measured value is indicated on the LC display or an externally connectable measuring instrument. In this way any changes, for example when circuits are connected to the system, can be recognised easily. The fault message can be stored. The fault memory can be reset by pressing the reset button. By pressing the test button, the function of the device as well as the connections to system and earth can be tested. Pressing the Info button provides additional information, such as the existing system leakage capacitance or device settings. The function of the device and the system and earth connections are continuously monitored. When a fault occurs, the system fault relay switches and the alarm LED system fault lights up. The parameterisation of the device can be carried out via the LC display or the function buttons integrated in the front plate. Device version IRDH275B Device version IRDH275B includes the following additional functions: History memory with real-time clock to store all alarm messages with date and time stamp Electrically isolated RS-485 interface (BMS protocol) for communication with other Bender devices Isometer disconnecting relays for the operation of several ISOMETER s in coupled IT systems Current output 0(4 ) 20 ma (electrically isolated) Use in coupled IT systems Only one ISOMETER may be active when several IT systems are coupled. Isometer disconnecting relays and the control inputs F1/F2 integrated in version IRDH275B guarantee that only one ISOMETER is active at any one time. Measurement method The IRDH275(B) uses the patented AMP Plus measurement method. This measurement method allows concise monitoring of modern power supply systems, also in case of extensive, directly connected DC components and high system leakage capacitances. Standards The ISOMETER of the IRDH257 series complies with the requirements of the device standards: DIN EN 61557-8 (VDE 0413-8), EN 61557-8, IEC 61557-8, IEC 61326-2-4, DIN EN 60664-1 (VDE 0110-1), DIN EN 60664-3 (VDE 0110-3), ASTM F1669M-96 (2007), ASTM F1207M-96 (2007) 2 TDB106015en/05.2013

Operating elements IRDH275 Wiring diagram ISOMETER IRDH275 3 AC-System U n AC-System U n 3 4 3 N AC-System U n DC-System U n 1 2 3 4 5 6 7 8 2 5 1 - INFO button: to query standard information ESC button: back to the menu function 2 - TEST button: to call up the self test Arrow up button: Parameter changes, scroll 1 6 3 - RESET button: to delete alarm and fault messages Arrow down button: Parameter change, scroll. 4 - MENU button: to activate the menu system Enter button: to confirm parameter changes 5 - Alarm LED 1 lights: insulation fault, 1st warning level reached 6 - Alarm LED 2 lights: insulation fault, 2nd warning level reached 7 - LED lights: system fault 8 - LC display Response times t an [sec] C e [µf] ISOMETER response times in relation to the system leakage capacitances: C e = 1 500 µf, U n = 0 793 V/50 Hz R f 7 8 9 10 11 12 13 1 - Supply voltage US (see ordering information) via 6 A fuse; for UL and CSA applications, it is mandatory to use 5 A fuses. 2,3 - Connection to the 3AC system being monitored: Connect the terminals L1, L2 to neutral conductor N or terminals L1, L2 to conductor L1, L2. 4 - Connection to the AC system to be monitored: Connect terminals L1, L2 to conductor L1, L2. 5 - Connection of the DC systems being monitored: Connect terminal L1 to conductor L+, terminal L2 to conductor L- 6 - Separate connection of the equipotential bonding conductor to PE and KE *7 - External test button T1/T2 (N/O contact) *8 - External reset button R1/R2 (N/C contact or wire jumper) When the terminals are open, the fault message will not be stored, provided that the memory has not been activated via the operating menu. *9 - STANDBY by means of the function input F1, F2 : with the contact in closed position no insulation measurement takes place (Isometer disconnection B version only/no disconnection when operated via AK). 10 - IRDH275: Currrent output, electrically isolated: 0 400 µa IRDH275B: Currrent output, electrically isolated: 0 20 ma or 4 20 ma 11 - RS-485 interface 12 - Alarm relay: Alarm 1 13 - Alarm relay: Alarm 2/system * The terminal pairs 7, 8 and 9 must be wired galvanically isolate and must not have a connection to PE! TDB106015en/05.2013 3

Ordering information RS-485 interface Coupled IT systems Output ASCII-IsoData BMS not applicable applicable Current output 0 400 µa Current output 0(4) 20 ma 1) Supply voltage U S AC DC Type Art. No. 88 264 V 77 286 V IRDH275-435 B 9106 5100 19.2 72 V IRDH275-427 B 9106 5104 10.2 36 V IRDH275-425 B 9106 5108 88 264 V 77 286 V IRDH275B-435 B 9106 5101 19.2 72 V IRDH275B-427 B 9106 5105 10.2 36 V IRDH275B-425 B 9106 5109 1) Absolute values Device Option-W with increased shock and vibration resistance: Indicated by the letter W at the end of the order number. Suitable system components Type designation Type Page Maßbild XM112 Maßangabe in mm External kω measuring instruments Coupling devices 7204-1421 B 986 763 9604-1421 B 986 764 9620-1421 B 986 841 AGH150W-4 B 9801 8006 AGH204S-4 B 914 013 AGH520S B 913 033 Wiring diagrams IRDH275 connected to different types of coupling devices ISOMETER IRDH275 with coupling device AGH150W-4 ISOMETER IRDH275 with coupling device AGH204S-4 1 2 U n DC 0 1760 V U n ISOMETER IRDH275 with coupling device AGH520S U n 3/(N)/AC 50 400 Hz 0 7200 V 1 - without rectifier Un = 3AC 0 1650 V (DC max. 1000 V) 2 - with rectifier U n = 3AC 0 1300 V (peak voltage downstream of the rectifier or DC voltage intermediate circuit of max.1840 V) 2 AGH520S 5 4 3 4 TDB106015en/05.2013

Technical data Insulation coordination acc. to IEC 60664-1 Rated insulation voltage Rated impulse voltage/pollution degree AC 800 V 8 kv/3 Voltage ranges IRDH275 : Nominal system voltage U n AC, 3/(N)AC 0 793 V* Nominal frequency f n 50 460 Hz Nominal system voltage U n DC 0 650 V* IRDH275-435: Supply voltage U S (also see nameplate) AC 88 264 V* Frequency rangeu S 42 460 Hz Supply voltage U S (also see nameplate) DC 77 286 V* IRDH275-427: Supply voltage U S (also see nameplate) DC 19.2 72 V* IRDH275 Power consumption 14 VA Response values Response value R an1 (Alarm1) 1 kω 10 MΩ Response value R an2 (Alarm2) 1 kω 10 MΩ Relative uncertainty (20 kω 1 MΩ) (acc. to IEC 61557-8) ± 15 % Relative uncertainty (1 20 kω +2 kω/+20 % Relative uncertainty (1 10 MΩ) 0.2 kω/+20 % Response time t an at RF = 0.5 x Ran and Ce = 1 μf 5 s Hysteresis (1 10 kω) +2 kω Hysteresis (10 kω 10 MΩ) 25 % Measuring circuit Measuring voltage U m 50 V Measuring current I m (at RF = 0 Ω) 280 μa Internal DC resistance R i 180 kω Impedance Z i at 50 Hz 180 kω Permissible extraneous DC voltage U fg DC 1200 V Permissible system leakage capacitance 500 μf Factory setting 150 µf Displays Display, illuminated two-line display Characteristics (number) 2 x 16 Display range measured value 1 kω 10 MΩ Operating uncertainty (20 kω 1 MΩ) (nach IEC 61557-8) ± 15 %** Operating uncertainty (1 20 kω) ± 1 kω/± 15 %** Operating uncertainty (1 10 MΩ) ± 0.1 MΩ/± 15 %** Outputs/Inputs Test/reset button internal/external Cable length test/reset button, external 10 m Current output for measuring instrument SKMP (scale centre point = 120 kω): Current output IRDH275 (load) 400 μa ( 12.5 kω) Current output IRDH275B (load) 20 ma ( 500 Ω) Accuracy current output (1 kω 1 MΩ) related to the value indicated ±10 %, ±1 kω Serial interface Interface/protocol IRDH275 RS-485/ASCII-IsoData Interface/protocol IRDH275B RS-485/BMS Connection terminals A/B Cable length 1200 m Cable (twisted in pairs, one end of shield connected to PE) recommended: J-Y(St)Y min. 2 x 0.8 Terminating resistor 120 Ω (0.5 W) Device address, BMS bus 1 30 (factory setting = 3) Switching elements Switching elements 2 changeover contacts: K1 (Alarm 1), K2 (Alarm 2, device error) Operating principle K1, K2 (Alarm 1/Alarm 2) N/O or N/C operation Factory setting (Alarm 1/Alarm 2) N/O operation Electrical endurance, number of cycles 12000 Contact class IIB (DIN IEC 60255-23) Rated contact voltage AC 250 V/DC 300 V Making capacity AC/DC 5 A Breaking capacity 2 A, AC 230 V, cos phi = 0.4 0.2 A, DC 220 V, L/R = 0.04 s Contact rating at DC 24 V 2 ma (50 mw) Environment/EMC EMC acc. to IEC 61326-2-4 Ed. 1.0 Shock resistance IEC 60068-2-27 (device in operation) 15 g/11 ms Bumping IEC 60068-2-29 (transport) 40 g/6 ms Vibration resistance IEC 60068-2-6 (device in operation) 1 g/10 150 Hz Vibration resistance IEC 60068-2-6 (transport) 2 g/10 150 Hz Ambient temperature (during operation) -10 +55 C Ambient temperature (during storage) -40 +70 C Climatic class acc. to IEC 60721-3-3 3K5 Connection Connection screw-type terminals Connection properties rigid/flexible 0.2 4 mm²/0.2 2.5 mm² flexible with ferrules without/with plastic sleeve 0.25 2.5 mm² Tightening torque 0.5 Nm Conductor sizes (AWG) 24 12 Other Operating mode continuous operation Mounting display-oriented Distance to adjacent devices 30 mm Degree of protection, internal components (DIN EN 60529) IP30 Degree of protection, terminals (DIN EN 60529) IP20 Type of enclosure X112, free from halogen DIN rail mounting DIN EN 60715/IEC 60715 Flammability class UL94 V-0 Software version IRDH275 D160 V1.4 Software version IRDH275B D159 V1.4 Operating manual TGH1361 Weight 510 g Option W Shock resistance IEC 60068-2-27 (device in operation) 30 g/11 ms Bumping IEC 60068-2-29 (transport) 40 g/6 ms Vibration resistance IEC 60068-2-6 1.6 mm/10 25 Hz 4 g/25 150 Hz Ambient temperature (during operation) -40 +70 C Storage temperature range - 40 +85 C Screw mounting 2 x M4 The data labelled with an * are absolute values ** = Under EMC test conditions in accordance with IEC 61326-2-4 the specified tolerances can double TDB106015en/05.2013 5

Subject to change! TDB106015en / 05.2013 / Schw / Bender GmbH & Co. KG, Germany Bender GmbH & Co. KG P.O. Box 1161 35301 Grünberg Germany Londorfer Straße 65 35305 Grünberg Germany Tel.: +49 6401 807-0 Fax: +49 6401 807-259 E-Mail: info@bender-de.com www.bender-de.com BENDER Group