precision glass capillary viscometers



Similar documents
Viscometers. CANNON-FENSKE REVERSE FLOW VISCOMETER TYPE for opaque and transparent liquids

LABORATORY.

Viscosity. Test Methods

Standard Test Method for Kinematic Viscosity of Asphalts (Bitumens) 1

Ubbel. Viscometers and their range of use. Viscometer type. Cannon-Fenske reverse flow BS/IP-U tube reverse flow. Cannon-Fenske-Routine

Kinematic viscometers in accordance with ISO 3105, DIN 51562, ASTM D445 For automatic and manual viscosity measuring Greatest precision and durability

Catalogue June2012, R1.0. Tamson Instruments

A H M 531 Penetration & Ring & Ball & Ductility & Flash & Fire point By: Mu'men Al-Otoom

Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best

CHAPTER 2: LIQUID VISCOSITY MEASUREMENT

POLYDIMETHYLSILOXANE

Standard Test Methods for Determination of Solution Viscosities of Polyamide (PA) 1, 2

Standard Test Methods for Viscosity of Adhesives 1

PENETRATION OF BITUMINOUS MATERIALS

OIL CONDITION MONITORING: AUTOMOTIVE ANALYSIS

PRODUCT GUIDE PRECISION INSTRUMENTS FOR Temperature, Density, Time, Weather and Calibration

Calibration Certificate

DENSITY MEASURING SYSTEMS

Trend Health Check & Monitoring Program - in-depth fluid condition analysis at laboratory

How To Use An Irius Pid Detector

Hello viewers welcome to lesson 4.7 which is on pavement materials part IV and in this lesson we will be covering bituminous binders.

Viscosity - Flow Cups. elcometer.com

CATALOGUE REFERENCE MATERIALS

1. The Determination of Boiling Point

Determination of Viscosity Using A Brookfield Viscometer for Conditioning Polymers

Viscosity. Desmond Schipper Andrew R. Barron. 1 Introduction

Flash Point. Test Methods

The Safest Heating Method!

Viscosity (VIS) Topic: Mechanics. Laminar and turbulent flow, Reynolds number, Hagen-Poiseuille s law, Stokes law

Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer 1

Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1.

Ultrasonic Reference Blocks

Penetration. Test Methods

HIGHWAYS DEPARTMENT GUIDANCE NOTES ON ROAD SURFACE REQUIREMENTS FOR EXPRESSWAYS AND HIGH SPEED ROADS

Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution

MATRIX GEMINI LIMS AT WORK IN THE FOOD INDUSTRY

Viscosity Cup Reference Table 1

ROTOFIX 32 A Benchtop Centrifuge

NEW SMART STEAM DISTILLATION VAPODEST 200 VOLATILES SO 2 ALCOHOL PHENOLS KJELDAHL-N UNRIVALED EASE OF USE EFFICIENCY FUNCTIONS SAFETY

109 Adopted:

Oil Analysis. It is important that the sampling be done in the following manner: 1.

Elcometer Viscosity Cups (AFNOR, BS, DIN, FORD, ISO)

To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.

Determination of Ultra Low Chlorine (and Sulfur) in Oil

How To Test A Titrette And Digital Burette

Electrical and mechanical interface requirements for separable HR, LR and LRM voltage detecting systems

Test equipment for temperature and its reduction

ORGANIC SAMPLE PREPARATION

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

FederalDemocratic RepublicofEthiopia

VISCOSITY CLASSIFICATIONS

Vacuum drying oven for non-flammable solvents

Elcometer Viscosity Cups (AFNOR, BS, DIN, FORD, ISO)

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

Designation: Manual of Petroleum Measurement Standards (MPMS), Chapter 9.1

World-Class Oil Sampling It is Possible

Draeger-Tubes and accuro Pump

Measuring Extruders and Extrusiograph. ... where quality is measured.

Color, True and Apparent

Portable digital microprocessor thermometers with interchangeable probes

Penetration Test Methods

ASTM Certified Glass Thermometers

PA94 Plus Basic. System Overview. Accessories/Options. PA94 Plus Basic Quick Release LDV Coupling PA94 Plus Basic Fixed LDV

The NEW Advanced Range of Portable Temperature Calibrators PROVISIONAL. Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources

limit to percentage levels, a limited working range translates

SOLENOID VALVES AND PNEUMATIC VALVES

Color, True and Apparent

A U T O M O T I V E L I F T S

Standard Test Method for Water in Petroleum Products and Bituminous Materials by Distillation 1

ERAFLASH NEW! THE SAFE SIDE OF FLASHPOINT TESTING. One Flashpoint Tester for All Applications:

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Particle Measurement Technology in Practice. From Theory to Application.

EasyTrack 2 Accessories List

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

Laboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen

HFM Heat Flow Meter Thermal Conductivity Analyzer

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

CSI Oil Analysis Options

What Can the OIL ANALYZERS Fluid Analysis Program Do For You?

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

DEHNshield Application-optimised multipole combined lightning current and surge arrester

OPTICAL PARTICLE SIZER MASS CALIBRATION METHOD

Esterification Method 1 Method to 2800 mg/l (as acetic acid) Reagent Solution

Density/Specific Gravity/ Concentration Meter DMA 500

MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX AL-KHOBAR KINGDOM OF SAUDI ARABIA

Root ZX II Endodontic Predictability Apex Locator with Low Speed Handpiece. Thinking ahead. Focused on life.

haze-gard i The objective standard for a clear view Global communication Reliable and Precise

Titrette. class A precision. The next generation Digital Burette!

Sampling Solutions. Fuel and Lube Oil sampling Equipment. Convenient, Representative, Approved.

Viscosity: A Property of fluids Compare the viscosity of various liquids Describe factors that can modify the viscosity of a liquid 208-6

GC/MS Considerations for Fracking Gases and Water. Dr. Harold McNair Virginia Tech Blacksburg, VA.

Performance Graded Asphalt Binders Bob Horan, P.E. Consulting Engineer Mechanicsville, VA

X-SERIES THERMAL IMAGING CAMERAS

OT 40L / 90L. Laboratory Steam Sterilizers

Your Service Partner Avonmouth and Bristol Service Centres

Transcription:

precision glass capillary viscometers

ASTM Ubbelohde Suitable for measuring transparent liquids. High precision & easy to use. Nominal overall length 283 mm; approximate sample volume 18 ml. Complete with ISO 17025 certificate of calibration. U-Tube Reverse Flow Viscometers Suitable for measuring opaque liquids. Type BS/IP/RF. Nominal overall length 275 mm; approximate sample volume 12-25 ml. Complete with ISO 17025 certificate of calibration. 1643/01 O 0.001 0.3 to 1 1643/02 OC 0.003 0.6 to 3 1643/03 OB 0.005 1 to 5 1643/04 1 0.01 2 to 10 1643/05 1C 0.03 6 to 30 1643/06 1B 0.05 10 to 50 1643/07 2 0.1 20 to 100 1643/08 2C 0.3 60 to 300 1643/09 2B 0.5 100 to 500 1643/10 3 1.0 200 to 1,000 1643/11 3C 3.0 600 to 3,000 1643/12 3B 5.0 1,000 to 5,000 1643/13 4 10 2,000 to 10,000 1643/14 4C 30 6,000 to 30,000 1643/15 4B 50 10,000 to 50,000 1643/16 5 100 20,000 to 100,000 1637/01 1 0.003 0.6 to 3 1637/02 2 0.01 2 to 10 1637/03 3 0.03 6 to 30 1637/04 4 0.1 20 to 100 1637/05 5 0.3 60 to 300 1637/06 6 1.0 200 to 1,000 1637/07 7 3.0 600 to 3,000 1637/08 8 10 2,000 to 10,000 1637/09 9 30 6,000 to 30,000 1637/10 10 100 20,000 to 100,000 1637/11 11 300 60,000 to 300,000 Cannon-Fenske Routine Suitable for measuring transparent liquids. Calibration data stated at 40 & 100ºC. Nominal overall length 250 mm; approximate sample volume 7 ml. Complete with ISO 17025 certificate of calibration. Cannon-Fenske Opaque Suitable for measuring opaque liquids. Calibration data stated at 40 & 100ºC. Nominal overall length 295 mm; approximate sample volume 12 ml. Complete with ISO 17025 certificate of calibration. 1634/01 25 0.002 0.5 to 2 1641/01 25 0.002 0.4 to 2 1634/02 50 0.004 0.8 to 4 1641/02 50 0.004 0.8 to 4 1634/03 75 0.008 1.6 to 8 1641/03 75 0.008 1.6 to 8 1634/04 100 0.015 3 to 15 1641/04 100 0.015 3 to 15 1634/05 150 0.035 7 to 35 1641/05 150 0.035 7 to 35 1634/06 200 0.1 20 to 100 1641/06 200 0.1 20 to 100 1634/07 300 0.25 50 to 250 1641/07 300 0.25 50 to 250 1634/08 350 0.5 100 to 500 1641/08 350 0.5 100 to 500 1634/09 400 1.2 240 to 1,200 1641/09 400 1.2 240 to 1,200 1634/10 450 2.5 500 to 2,500 1641/10 450 2.5 500 to 2,500 1634/11 500 8 1,600 to 8,000 1641/11 500 8 1,600 to 8,000 1634/12 600 20 4,000 to 20,000 1641/12 600 20 4,000 to 20,000 1634/13 650 50 10,000 to 50,000 1641/13 650 50 10,000 to 50,000 1634/14 700 100 20,000 to 100,000 1641/14 700 100 20,000 to 100,000 PSL Rheotek offers a comprehensive range of precision calibrated glass capillary viscometers. Viscometers are made by our experienced glass blowers from high grade borosilicate glass tubing. PSL Rheotek viscometers are used by refinery, testing and research laboratories throughout the world and enjoy a high reputation for quality workmanship and accuracy of calibration.

Cannon-Ubbelohde Viscometers Suitable for transparent liquids. Nominal overall length 335mm, approximate sample size 11 ml. Complete with ISO 17025 certificate of calibration. Suspended-Level Viscometers Suitable for measuring transparent liquids. Type BS/IP/SL Nominal overall length 330mm; approximate sample volume 22-40 ml. Complete with ISO 17025 certificate of calibration. 1647/01 25 0.002 0.5 to 2 1647/02 50 0.004 0.8 to 4.0 1647/03 75 0.008 1.6 to 8.0 1647/04 100 0.015 3 to 15 1647/05 150 0.035 7 to 35 1647/06 200 0.1 20 to 100 1647/07 300 0.25 50 to 250 1647/08 350 0.5 100 to 500 1647/09 400 1.2 240 to 1,200 1647/10 450 2.5 500 to 2,500 1647/11 500 8.0 1,600 to 8,000 1647/12 600 20 4,000 to 20,000 1647/13 650 45 9,000 to 45,000 1647/14 700 100 20,000 to 100,000 1625/01 1 0.01 3.5 to 10 1625/02 1A 0.03 6 to 30 1625/03 2 0.1 20 to 100 1625/04 2A 0.3 60 to 300 1625/05 3 1.0 200 to 1,000 1625/06 3A 3.0 600 to 3,000 1625/07 4 10 2,000 to 10,000 1625/08 4A 30 6,000 to 30,000 1625/09 5 100 20,000 to 100,000 Suspended-Level Viscometers, Shortened Form Suitable for measuring transparent liquids. Type BS/IP/SL Nominal overall length 250mm; approximate sample volume 10 ml. Complete with ISO 17025 certificate of calibration. 1628/01 1 0.0008 1.05 min 1628/02 2 0.003 2.1 to 3 1628/03 3 0.01 3.8 to 10 1628/04 4 0.03 6 to 30 1628/05 5 0.10 20 to 100 1628/06 6 0.3 60 to 300 1628/07 7 1.0 200 to 1,000 1628/08 8 3.0 600 to 3,000 1628/09 9 10 2,000 to 10,000 Miniature Suspended-Level Viscometers Suitable for measuring transparent liquids. Type BS/IP/MSL Nominal overall length 330mm; approximate sample volume 4 ml. Complete with ISO 17025 certificate of calibration. 1631/01 1 0.003 0.6 to 3 1631/02 2 0.01 2 to 10 1631/03 3 0.03 6 to 30 1631/04 4 0.1 20 to 100 1631/05 5 0.3 60 to 300 1635/06 6 1.0 200 to 1,000 1635/07 7 3.0 600 to 3,000 Viscometer calibration is performed on-site by our UKAS accredited ISO 17025 calibration laboratory. The PSL Calibration Laboratory maintains a master viscometer scale in accordance with ASTM D2162. All calibration data us directly traceable to international standards.

Cannon-Manning Vacuum Capillary Viscometer Suitable for measuring the dynamic viscosity of bituminous binders. Nominal overall length 245 mm. Calibrated in accordance with EN 12596 and ASTM D2171. Part No. Size Constant Range (Pa.s) 1676/01 4 0.0002 0.0036 to 0.08 1676/02 5 0.0006 0.012 to 0.24 1676/03 6 0.002 0.036 to 0.8 1676/04 7 0.01 0.12 to 2.4 1676/05 8 0.02 0.36 to 8.0 1676/06 9 0.06 1.2 to 24 1676/07 10 0.2 3.6 to 80 1676/08 11 0.6 12 to 240 1676/09 12 2.0 36 to 800 1676/10 13 6.0 120 to 2400 1676/11 14 20.0 360 to 8000 Note: Nominal constant for bulb B is shown for illustration purposes. Asphalt Institute Vacuum Capillary Viscometer Suitable for measuring the dynamic viscosity of bituminous binders. Nominal overall length 245 mm. Calibrated in accordance with EN 12596 and ASTM D2171. Range (Pa.s) 1677/01 25 0.2 4.2 to 80 1677/02 50 0.8 18 to 320 1677/03 100 3.2 60 to 1280 1677/04 200 12.8 240 to 5200 1677/05 400 50 960 to 20000 1677/06 400Rc 50 960 to 140000 1677/07 800Rc 200 3800 to 580000 Note: Nominal constant for bulb B is shown for illustration purposes. Modified Koppers Vacuum Capillary Viscometer Suitable Suitable for for measuring measuring the the dynamic dynamic viscosity viscosity of of bituminous bituminous binders. binders. Nominal Nominal overall overall length length 270 270 mm. mm. Calibrated Calibrated in in accordance accordance with with EN EN 12596 12596 and and ASTM ASTM D2171. D2171. Vacuum System for bituminous binders Complete with vacuum controller, vacuum pump, valve control module and glass bottle. Range (Pa.s) 1678/01 25 0.2 4.2 to 80 1678/02 50 0.8 18 to 320 1678/03 100 3.2 60 to 1280 1678/04 200 12.8 240 to 5200 1678/05 400 50 960 to 20000 Note: Nominal constant for bulb B is shown for illustration purposes. Part No. 20700/01 20700/02 Description Bitumen Vacuum System 240V / 50Hz Bitumen Vacuum System 110V / 60Hz PSL Rheotek bitumen viscometers are suitable for measuring a wide range of liquid asphalts, bituminous binders and asphalt cements. For vacuum capillary viscometers, a bitumen vacuum system is available. Other accessories include viscometer bath, silicone bath oil and viscosity oil standards.

U-Tube Viscometers Suitable for measuring transparent liquids. Type BS/U - Nominal overall length 300 mm, approximate sample volume 13-40 ml. Complete with ISO 17025 certificate of calibration. 1619/00 O 0.001 0.3 to 1 1619/01 A 0.003 0.9 to 3 1619/02 B 0.01 2.0 to 10 1619/03 C 0.03 6 to 30 1619/04 D 0.1 20 to 100 1619/05 E 0.3 60 to 300 1619/06 F 1.0 200 to 1,000 1619/07 G 3.0 600 to 3,000 1619/08 H 10 2,000 to 10,000 Cannon Manning Semi-Micro Viscometers Type ASTM Suitable for transparent liquids. Nominal overall length 275 mm; approximate sample volume 1 ml. Complete with ISO 17025 certificate of calibration. 1659/01 25 0.002 0.4 to 2.0 1659/02 50 0.004 0.8 to 4.0 1659/03 75 0.008 1.6 to 8.0 1659/04 100 0.015 3 to 15 1659/05 150 0.035 7 to 35 1659/06 200 0.1 20 to 100 1659/07 300 0.25 50 to 250 1659/08 350 0.5 100 to 500 1659/09 400 1.2 240 to 1,200 1659/10 450 2.5 500 to 2,500 1659/11 500 8.0 1,600 to 8,000 1659/12 600 20 4,000 to 20,000 Miniature U-Tube Viscometers Suitable for measuring transparent liquids. Type BS/U/M - Nominal overall length 250 mm, approximate sample volume 4 ml. Complete with ISO 17025 certificate of calibration. 1622/01 M1 0.001 0.2 to 1 1622/02 M2 0.005 1 to 5 1622/03 M3 0.015 3 to 15 1622/04 M4 0.04 8 to 40 1622/05 M5 0.1 20 to 100 Zeitfuchs Cross-Arm Viscometers Type ASTM Nominal overall length 295 mm; approximate sample volume up to 3 ml. Complete with ISO 17025 certificate of calibration. 1663/01 1 0.003 0.6 to 3 1663/02 2 0.01 2 to 10 1663/03 3 0.03 6 to 30 1663/04 4 0.1 20 to 100 1663/05 5 0.3 60 to 300 1663/06 6 1.0 200 to 1,000 1663/07 7 3.0 600 to 3,000 1663/08 8 10 2,000 to 10,000 1663/09 9 30 6,000 to 30,000 1663/10 10 100 20,000 to 100,000 PSL Rheotek glass capillary viscometers are suitable for a wide range of applications. Applicable petroleum testing methods include ASTM D445, D446, D2162, D2170, D2171, ISO 3104 & ISO3105. Other applications include polymers, cellulose, blood and plasma.

Accessories Metal Viscometer Holders Viscometer Bench Stand Part No. 20430 Part No. Specifications 1850/A1 Universal Viscometer Holder 1818/A1 U-Tube Viscometer Holder Size O to F 1818/A2 U-Tube Viscometer Holder Size G & H 1824/A1 Suspended-Level Viscometer Holder Size 1 to 4 1824/A2 Suspended-Level Viscometer Holder Size 4A & 5 1827/A1 Suspended-Level Short Form Viscometer Holder 1833/A1 1836/A1 Cannon-Fenske Routine Viscometer Holder U-Tube Reverse Flow Viscometer Holder 1840/A1 1842/A1 1842/A2 Cannon-Fenske Opaque Viscometer Holder Ubbelohde Viscometer Holder Size 0 to 4 Ubbelohde Viscometer Holder Size 4C to 5 Plastic Viscometer Holders Part No. Specifications 1934/A1 Plastic holder for CF Routine & Opaque 1943/A1 Plastic holder for ASTM Ubbelohde (sizes O to 4) SCAN Viscometer Part No. 21003/Type C Part No. 21004/Type T Viscometer Bath PSL Master Viscometer. Part No. 1690 series Precision Digital Thermometer Part No. TT3 TLC-250 Chiller Part No. TLC-250 TCB-7 Viscometer Bath Part No. 20402 Other Viscometers available: Master Viscometers Scan Viscometers Ostwald Viscometers Suspended-Level dilution Viscometers Deoxyribonuclease Assay Viscometers Falling Sphere Viscometers

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.