Agilent Cary 4000/5000/6000i Series UV-Vis-NIR



Similar documents
Agilent Cary 60 UV-Vis

UV-VIS-NIR Cary 4000, 5000, 6000i Spectrophotometers Preliminary Performance Data

CARY UV-VIS-NIR SPECTROPHOTOMETERS UV-VIS-NIR. Typical Specifications

instruments Analytical Instruments for Science

VWR SPECTROPHOTOMETERS

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

UV-VISIBLE SPECTROPHOTOMETER

Hitachi U-4100 UV-vis-NIR spectrophotometer (341-F)

UV-VIS-NIR. Varian Cary 4000, 5000 and 6000i Spectrophotometers

Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy

UV-Vis spectrophotometers

Hellma. Where precision becomes an art. Calibration standards for spectrophotometers by Hellma

MCAL Spectrophotometry. Spectrophotometry

73 Series Spectrophotometers

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

INTERNATIONAL OLIVE COUNCIL

Copyright by Mark Brandt, Ph.D. 12

V-700 series. UV-Visible/NIR Spectrophotometers

Spectrophotometer Water Quality Analysers

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Quasi-Continuous Wave (CW) UV Laser Xcyte Series

Thermo Scientific GENESYS 10S Series UV-Visible Spectrophotometers

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Measurement & Analytics Measurement made easy

MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC

SUPPLY & INSTALLATION OF UV-VIS SPECTROPHOTOMETER IN SCHOOL OF BASIC SCIENCE, IIT MANDI

Hitachi Double Beam Spectrophotometer

Nederland België / Belgique

SOLSPEC MEASUREMENT OF THE SOLAR ABSOLUTE SPECTRAL IRRADIANCE FROM 165 to 2900 nm ON BOARD THE INTERNATIONAL SPACE STATION

Amplified High Speed Fiber Photodetectors

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

Single Photon Counting Module COUNT -Series

Thermo Scientific Dionex UltiMate 3000 Variable Wavelength Detectors

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

HITACHI SPECTROPHOTOMETER Measurement Systems for Optical Parts / New Materials

IR Sensor Module for Reflective Sensor, Light Barrier, and Fast Proximity Applications

MAR MEMS 2D Laser Scanning Mirror Data Sheet Rev 2

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

Validating UV/Visible Spectrophotometers

Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions

JASCO. FP-6000 Series Spectrofluorometer. Fluorescence Spectrophotometer

Agilent E5100A Network Analyzer

Reprint (R22) Avoiding Errors in UV Radiation Measurements. By Thomas C. Larason July Reprinted from Photonics Spectra, Laurin Publishing

Evaluating System Suitability CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x

USB-ISS-UV/VIS Integrated Sampling System Installation and Operation Instructions

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

How To Use A Ds340 (Dsp)

PinAAcle 900 AA Spectrometers

FTIR Instrumentation

Silicon PIN Photodiode

C101-E142 TALK LETTER. Vol. 16

Silicon PIN Photodiode

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber

Data. microcat +SPECT

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Hitachi Spectrophotometer

Agilent AEDB-9140 Series Three Channel Optical Incremental Encoder Modules with Codewheel, 100 CPR to 500 CPR Data Sheet

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

QUANTITATIVE DETERMINATION OF COMMON TYPES OF ASBESTOS BY DIFFUSE REFLECTANCE FTIR

Adjustment functions for both span and shift have been incorporated

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Simplicity. Reliability. Performance

User guide for Cary 5000 absorption spectrometer with external DRA 1800 attachment.

Dual Laser InfraRed (IR) Thermometer

UV/VIS Spectrophotometer PG INSTRUMENTS LIMITED

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Introduction to Fourier Transform Infrared Spectrometry

Raman Spectroscopy Basics

UV-1700 series SERVICE MANUAL

Analysis of Chlorine, Bromine and Iodine in Water using ICP-AES

FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS. drm TesT equipment

Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information

RIEGL VQ-480. Airborne Laser Scanning. Airborne Laser Scanner with Online Waveform Processing. visit our website

SGS: Das Scanning Grating Spektrometer Ein kleines, günstiges Spektrometermodul auf Basis eines dispersiven Mikrosystems

Thyristor-controlled power supplies and battery chargers

Report of the Spectral Irradiance Comparison EURAMET.PR-K1.a.1 between MIKES (Finland) and NIMT (Thailand)

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family

palmotdr Series Handheld OTDR

LUT Luminescence scanners: Seeing what no-one else can

Raman spectroscopy Lecture

LwLVision-USB 2.0. Installation Guide

GE Healthcare. Lullaby Warmer. Because every baby deserves a high standard of care

IR Receiver Module for Light Barrier Systems

UV-VIS VARIAN, INC. Cary 100/300 UV-Vis. S p e c t r o p h o t o m e t e r s

M-D,T,Q-series BroadLighter. Benchtop Broadband Light Source with Extended Bandwidth. Technical Product Specification

DS 600. A contact free flux gate based current measurement sensor 600A rms

Dual Laser InfraRed (IR) Thermometer

BY UV SPECTROPHOTOMETRY

3 - Atomic Absorption Spectroscopy

Uses of Derivative Spectroscopy

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Dual Laser InfraRed (IR) Thermometer with Color Alert

APPLICATION NOTE. Basler racer Migration Guide. Mechanics. Flexible Mount Concept. Housing

Transcription:

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR Guaranteed specifications Design overview Double beam, ratio recording, double out-of-plane Littrow monochromator UV-Vis-NIR spectrophotometer (Agilent Cary 4000 is UV-Vis only). 2 x 400 mm focal length, dual double sided gratings (Agilent Cary 4000 single sided only), centrally controlled by a PC. Features Optical Isolation System for low noise performance and minimized impact from surrounding environment. High speed non-measurement-phase-stepping wavelength drive. UV-Vis detector: high performance R928 photomultiplier tube, NIR detector: electrothermally controlled lead sulfide photocell (Agilent Cary 5000) incorporating PbSmart technology for better noise and linearity performance than standard photocells, or electrothermally controlled Indium Gallium-Arsenide PIN photodiode (Agilent Cary 6000i) for the ultimate in low noise, linearity and resolution in the NIR. Tungsten halogen visible source with quartz window, deuterium arc UV source. Supplied as standard is a mercury lamp module for automatic wavelength accuracy validation. Features Plug-and-Go lamp management. Lamps are pre-aligned and easily replaced, requiring no adjustment. Plug-and-Go supports a wide range of lamp designs. Precision Lock Down mechanism for quick and reproducible accessory change overs. The Agilent Cary Lock Down system eliminates tools and time consuming alignment. Choice of software interfaces. Agilent Cary 4000/5000/6000i Series UV-Vis-NIR spectrophotometers are manufactured according to a quality management system certified to ISO 9001. These guaranteed specifications are based on the ±4 sigma statistical confidence level of the final acceptance tests performed at the factory. Typical specifications are not reported in this document. Operators can routinely repeat performance tests using Agilent s dedicated instrument performance test software suite Validate. Some tests, where indicated, require equipment or certified material, which can be obtained through Agilent or international standard organizations.

Performance specifications Monochromator Agilent Cary 4000 Agilent Cary 5000 Agilent Cary 6000i Double out-of-plane Littrow monochromator Grating 70 x 45 mm 70 x 45 mm 70 x 45 mm UV-Vis 1200 lines/mm blazed at 250 nm 1200 lines/mm blazed at 250 nm 1200 lines/mm blazed at 250 nm NIR 300 lines/mm blazed at 1192 nm 600 lines/mm blazed at 1000 nm Beam splitting system Rotating beam splitter, which measures a sample, dark and reference signal per cycle with a speed of 30 Hz Detectors UV-Vis R928 PMT R928 PMT R928 PMT NIR Cooled PbS Cooled InGaAs Limiting resolution (nm) UV-Vis <0.048 nm <0.048 nm <0.048 nm NIR <0.2 nm Stray light (%T) At 220 nm (10 g/l NaI ASTM method) <0.00007% <0.00007% <0.00007% At 370 nm (50 mg/l NaNO2) <0.00007% <0.00007% <0.00007% At 1420 nm (H2O, 1 cm pathlength) <0.0002% <0.0001% At 2365 nm (CHCl3, 1 cm pathlength) <0.00045% Wavelength range (nm) (N2 purge required below 185 nm) 175 900 nm 175 3300 nm 175 1800 nm Wavelength accuracy (nm) Deuterium lamp lines UV-Vis: 190 900 nm ± 0.08 nm ± 0.08 nm ± 0.08 nm NIR: 760 3000 nm (Cary 5000) NIR: 760 1700 nm (Cary 6000i) ± 0.4 nm ± 0.4 nm Wavelength reproducibility (nm) Peak separation of repetitive scanning of a UV-Vis line source Peak separation of repetitive scanning of a NIR line source <0.025 nm <0.025 nm <0.025 nm <0.1 nm <0.05 nm Standard deviation of 10 measurements, UV-Vis <0.005 nm <0.005 nm <0.005 nm Standard deviation of 10 measurements, NIR <0.02 nm <0.02 nm Photometric accuracy (Abs) Using double aperture method at 0.3 Abs UV-Vis <0.00025 Abs <0.00025 Abs <0.00025 Abs Photometric linearity (Abs) All tests performed by addition of filters technique UV-Vis (465 nm, 10 s SAT, 2 nm SBW), NIR (1200 nm, 10 s SAT, energy 3) UV-Vis, at 1 Abs <0.0007 Abs <0.0007 Abs <0.0007 Abs UV-Vis, at 2 Abs <0.0014 Abs <0.0014 Abs <0.0014 Abs UV-Vis, at 3 Abs <0.005 Abs <0.005 Abs <0.005 Abs NIR, at 1 Abs <0.0015 Abs <0.0005 Abs NIR, at 2 Abs <0.007 Abs <0.0018 Abs Photometric range (Abs) with RBA 8 Abs 8 Abs 8 Abs 2

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR Performance specifications Agilent Cary 4000 Agilent Cary 5000 Agilent Cary 6000i Photometric reproducibility (Abs) Using NIST 930D filters, at 546.1 nm, 2 s SAT, 2 nm SBW 0.5 Abs, Standard deviation for 10 measurements <0.00008 <0.00008 <0.00008 1.0 Abs, Standard deviation for 10 measurements <0.00014 <0.00014 <0.00014 Photometric stability (Abs/hour) After 2 hr warm up, 500 nm, 1 s SAT, 2 nm SBW <0.00018 <0.00018 <0.00018 Photometric noise (Abs/RMS) UV-Vis (190 nm, 1 s SAT, 2 nm SBW) At 0 Abs <0.00009 <0.00009 <0.00009 At 1 Abs <0.0002 <0.0002 <0.0002 UV-Vis (500 nm, 1 s SAT, 2 nm SBW) At 0 Abs <0.00003 <0.00003 <0.00003 At 1 Abs <0.00005 <0.00005 <0.00005 At 2 Abs <0.0001 <0.0001 <0.0001 At 3 Abs with 1.5 Abs RBA <0.0003 <0.0003 <0.0003 At 4 Abs with 1.5 Abs RBA <0.0008 <0.0008 <0.0008 At 5 Abs with 1.5 Abs RBA <0.002 <0.002 <0.002 At 6 Abs with 3.0 Abs RBA <0.0045 <0.0045 <0.0045 NIR: Fixed SBW (1500 nm, 1 s SAT, 2 nm SBW (Cary 5000), 1500 nm, 1 s SAT, 0.4 nm SBW (Cary 6000i)) At 0 Abs <0.00003 <0.00002 At 1 Abs <0.0001 <0.00004 At 2 Abs <0.0005 <0.0002 At 3 Abs <0.007 <0.001 At 4 Abs <0.007 NIR: Variable SBW (1500 nm, 1 s SAT, Energy 1) At 0 Abs <0.00004 <0.00002 At 2 Abs <0.0005 At 3 Abs with 1.5 Abs RBA <0.0003 <0.00006 At 6 Abs with 3.0 Abs RBA <0.0009 Baseline flatness (Abs) UV-Vis (0.1 s SAT, 4 nm SBW), NIR (0.2 s SAT, Energy 1), baseline corrected UV-Vis (0.2 s SAT, 2 nm SBW), NIR (0.24 s SAT, Energy 1), no smoothing applied ± 0.0012 (200 to 850 nm) ± 0.0012 (200 to 3000 nm) ± 0.0012 (200 to 1700 nm) ± 0.0007 (200 to 850 nm) ± 0.0007 (200 to 3000 nm) ± 0.0007 (200 to 1700 nm) 3

Performance specifications Agilent Cary 4000 Agilent Cary 5000 Agilent Cary 6000i Sample compartment beam separation (mm) 190.5 mm 190.5 mm 190.5 mm Compartment size (width x depth x height) Extended sample compartment fitted 160 x 433 x 221 mm 160 x 433 x 221 mm 160 x 433 x 221 mm Access Top, front and base Top, front and base Top, front and base Instrument dimensions (width x depth x height) 1020 x 710 x 380 mm 1020 x 710 x 380 mm 1020 x 710 x 380 mm Purging Sample compartment Yes Yes Yes Optics Yes Yes Yes Instrument weight 91 kg 91 kg 91 kg Operational Spectral bandwidth (nm) UV-Vis 0.01 5.00 nm, 0.01 nm steps 0.01 5.00 nm, 0.01 nm steps 0.01 5.00 nm, 0.01 nm steps NIR 0.04 20 nm 0.04 20 nm Signal averaging (seconds) 0.033 999 s 0.033 999 s 0.033 999 s Maximum scan rate (nm/min) UV-Vis 2000 nm/min 2000 nm/min 2000 nm/min NIR 8000 nm/min 8000 nm/min Slew rate (changing between wavelengths, nm/min) UV-Vis 16000 nm/min 16000 nm/min 16000 nm/min NIR 64000 nm/min 32000 nm/min Data interval (UV-Vis) (nm) 0.005-1.111 nm 0.005 1.111 nm 0.005 1.111 nm cm -1 * 1.633-13.699 cm -1 * 1.627 17.335 cm -1 * 1.627 17.335 cm -1 * Å 0.05-11.1 Å 0.05 11.1 Å 0.05 11.1 Å Data interval (NIR) (nm) 0.02 4.444 nm 0.02 2.222 nm cm -1 * 0.3145 4.0753 cm -1 * 0.3145 2.0377 cm -1 * Å 0.2 44.44 Å 0.2 22.22 Å * Interval range is dependent upon scan range Repetitive scanning Maximum number of cycles 999 999 999 Maximum cycle time (min) 9999 9999 9999 4

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR Recommended environmental conditions Agilent Cary 4000/5000/6000i Instrument storage 5 45 C at 20 80% relative humidity, non-condensing, altitude < 2133 m. Instrument operation Instrument electrical requirements Below 853 m altitude: 10 35 C, 50 80% relative humidity, non-condensing. Between 853 and 2133 m altitude: 10 25 C, 50 80% relative humidity, non-condensing. Mains supply of 85 264 volts AC with 300 VA power consumption. Frequency 47-63 Hz. Support policies Further details Type Warranty Hardware support period Software support More information Policy 12 months, though this may vary according to location Seven (7) years from date of last unit manufacture. After this time, parts and supplies will be provided if available Telediagnostic capability is available for some instrument models. Availability of Telediagnostic support may vary according to location. Software upgrades to add additional functionality will attract a fee. For further information please consult your Agilent office or supplier, or our Web site at www.agilent.com 5

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc. 2011 Published May 6, 2011 Publication number: 5990-8077EN