Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. OMNISTAT 2 (RC-1000 and RC-2000) WIRED MODELS ONLY.



Similar documents
RadioRA 2 (QS) Lighting and Climate Control. g! 5.4 Fan Controller: g! RadioRA2 Inclusive Software v5.0.8 or newer

Model Number(s): SRC, SRC Plus, Pro-C, ICC, XCORE, icore

Export: Exporting the call log or Voice Mail messages from the Viewer software is not supported.

Minimum Core Module Version: Comments: Server Version: IP Video V2.38 & V2.39 Document Revision Date: 2/13/2013

Baldwin, Kwikset, Schlage, Yale. 5.7 or newer required

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

T-100-R Installation Guide

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Digi-Motor Installation Guide

Workshop 7 PC Software - Tracker

for Windows Media Center User's Guide

DUKANE Intelligent Assembly Solutions

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline

The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Bluetooth HC-06 with serial port module Easy guide

Energy Communication Unit (ECU)

How to setup a serial Bluetooth adapter Master Guide

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

GV- RK1352 Card Reader

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

Energy Communication Unit (ECU)

1 Serial RS232 to Ethernet Adapter Installation Guide

HDMI Switch USER MANUAL VS481A

INSIDE WDDCMON. User s Guide for the ENVIRO-TEC DDC Control System Windows Based Software

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

MS830 / MS833 Barcode Reader v1.0 9-December-2014

1-Port R422/485 Serial PCIe Card

UPS Network Interface. Quick InstallationGuide

Omron I/O Driver (Series 2) Programmable Serial Interface Card

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

ETHERNET IRRIGATION CONTROLLER. Irrigation Caddy Model: ICEthS1. User Manual and Installation Instructions

User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller M720

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

Signature Center Getting Started Guide

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

How To Set Up A Smart Card Programmer With Titan (Titan) And Titan 2.3 (Tok) (Tonga) (Powerbook) (Smart Card) (Programmer) (S

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Setting up VPN Access for Remote Diagnostics Support

EDI Distributor Control Interface Wiring and Setup Instructions

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

HWg-STE HWg-STE PoE MANUAL

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

BASLER ACE QUICK INSTALLATION GUIDE

SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL

Six-servo Robot Arm. DAGU Hi-Tech Electronic Co., LTD Six-servo Robot Arm

HYDROSOFT Version INSTALLATION AND OPERATING

Professional Contractor INSTALLATION GUIDE

2S RS232 Multi Serial PCI Card Installation Guide

Configuring the Siemens TC35 modems for use with the MI2292

g!mobile 6 Android App Android 4.0 or above -- See Android Devices table for compatibility information Document Revision Date: 2/14/2013

Wireless Thermostats 230v and Battery Operated Instruction Manual

Making a DB to RJ45 adapter.

Bluetooth to Serial Adapter

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

RIU-IP Remote IP Interface User Guide

ServiceTools for MicroTech II Version 2.0 Applied Terminal Systems User Manual

Telebyte 209 Short Haul Modem

Honeywell Internet Connection Module

Serial Cables & Adapters

Dominion KX II-101-V2

F2103 GPRS DTU USER MANUAL

INTRODUCTION FEATURES OF THE ICM

IP Link Device Interface Communication Sheet

Introduction: Implementation of the MVI56-MCM module for modbus communications:

All of the above software and firmware are included in the VAV-B Package. Contact Customer Service or Technical Support for this, or for cables.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Contents Chapter 1: Introduction... 3 Chapter 2: Ethernet (LAN)... 5 Chapter 3: ZigBee Wireless Connection Options... 7

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP.

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

User s Manual for Fingerprint Door Control Software

USB to RS-422/485 Serial Adapter

[USING THE NM150 WITH ADULTICIDING] July 13, 2015

A L ERT. Quick Start With

Installation and Operation Guide

LBNP RS-232/485/422 serial device server. User manual

PLC training panel (Twido version)

ioptron ASCOM 3.11 PC Control Application Note

Bluetooth Serial Adapter

IntesisBox Modbus Server SAMSUNG Air Conditioners

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

Link Gate SIP. (Firmware version 1.20)

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

GE Security. FHSD Monitor / Web Server user manual

Transcription:

Manufacturer: Model Number(s): Minimum Core Module Version: Comments: HAI Document Revision Date: 4/18/2013 OMNISTAT 2 (RC-1000 and RC-2000) WIRED MODELS ONLY Firmware V. 1.03 Tested Integration Note OVERVIEW AND SUPPORTED FEATURES This Integration Note describes the integration of HAI thermostats by connecting them directly to the g! system, instead of wiring them into HAI Security panel. Refer to HAI Security Integration Notes for details on integrating HAI thermostats when they are wired into the Omni panel. Supported models: Omnistat2 WIRED Thermostats ONLY. Models that support Zigbee or other wireless formats are not compatible! THE HAI OMNISTAT2 COMMUNICATING THERMOSTATS SUPPORT THE FOLLOWING FEATURES: Temperature Control: Temperature control can be managed by schedules tied to house modes or by manual control based on time (Timed Temporary Hold, Temporary Hold and Permanent Hold). Mode Control: The climate system can be set to run in the following heating and cooling modes: Heat only, Cool only, Auto Heat/Cool or Off. In addition, systems that have a fan can be set to run in Automatic mode or Continuous mode. History View: The history view shows the inside temperature, outside temperature, unit run and fan run times, and cooling and heating setpoints. Schedule Control: Up to three schedules can be set using the Viewer software. The schedules are tied to the house mode. Auto Thermostat Detection: The g! system will automatically detect all the thermostats connected to system, along with each thermostat s ID (number). Celsius and Fahrenheit: HAI Thermostats support displaying Temperatures in C or F both at the stat and in the g! system. Remote Sensors that replace the internal sensor: HAI Thermostats may be capable of having a remote temperature sensor configured to replace the on-board room temperature thermistor. In this configuration ONLY remote sensors are supported. THE FOLLOWING FEATURES ARE UNSUPPORTED: Humidity Control: Humidifier/Dehumidifier control with RC-2000 thermostats is not currently supported. Humidity Display: Humidity readings from the RC-2000 thermostat cannot be displayed in the viewer. External Sensors: Additional Temperature sensor inputs are not supported at this time. Decimal Temperature Control: g! Core module 5.5 added support for decimal/fractional temperature display. The HAI Thermostats are not compatible with control using fractional numbers. Any feature not specifically noted as supported is not supported. ELAN Home Systems 1690 Corporate Circle Petaluma, CA 94954 USA tech support: 800.622.3526 main: 760.710.0990 sales: 877.289.3526 email: elan@elanhomesystems.com 2013 ELAN Home Systems. All rights reserved. ELAN and g! are trademarks of ELAN Home Systems. All other trademarks are the property of their respective owners.

INSTALLATION OVERVIEW 1. Install the HAI RS-232 thermostat communication network and control cables during the rough-in phase. Consult the HVAC unit manual for control cabling requirements. 2. Each serial port can support up to 4 thermostats without a booster. Installation of the booster will allow up to 127 thermostats per serial port. 3. Mount the punch down block and terminate the wires, as per the diagram provided. Make sure that the serial port cable is not plugged in prior to wiring. 4. Run a Cat5 wire from the punch down block back to the Network Assembly of the g! system. 5. Mount and connect the thermostats bases electrically using the diagrams provided. 6. Recheck the wiring on both at the thermostat and the punch down block. 7. Install and power up the thermostats one at a time. Setup the thermostats as outlined in the thermostat setup section, noting the thermostat ID number for each zone. 8. Test the thermostat and climate system to ensure that the thermostats correctly turn on the appropriate heating or cooling equipment, and open or close the appropriate valves / dampers. 9. Connect the g! system to the HAI thermostats electrically. See the wiring diagrams for more information. 10. Configure the g! system for the thermostats and confirm communication between the thermostats and the g! system controller. Use the auto detect (Discover Devices) feature to find the thermostats on the network. 11. Test the system by changing the set points, modes and schedules on the viewer and various thermostats, confirming that the various components in the system are in communicating with each other. 2 of 8

CONNECTION DIAGRAMS WIRING DIAGRAM 1 Wire the HAI OMNIStats for external control: Remove Jumper N / C Cat5 Cable (EIA 568 Standard B Colors) HAI OMNIStat 2 Communicating Thermostat Black Yellow White / White / 1: White / Orange 2: Orange 3: White / 4: 5: 6: 7: White / Brown 8: Brown Remove Jumper HAI OMNIStat 2 Communicating Thermostat N / C Black Yellow White / Cat5 Cable Cat5 Cable Cat5 Cable Remove Jumper HAI OMNIStat 2 Communicating Thermostat N / C Black Yellow White / All the terminals in the column are electrically connected Terminal Block (Clip Down) 8 RJ45 1 To Serial Port Remove Jumper N / C Notes: 1. Use a maximum of 4 thermostats per serial port. Use a second serial port to support 5-8 thermostats, or use a booster to support additional stats on a single serial port. HAI OMNIStat 2 Communicating Thermostat Black Yellow White / Cat5 Cable 3 of 8

OPTION 1: CONNECT UP TO FOUR THERMOSTATS TO THE g! CONTROLLER BILL OF MATERIALS # Device M anufacturer Part Number Protocol Connector Type Notes 1 Thermostat HAI RC-1000/RC-2000 RS-232 None 2 Cat5 Cable Installer N/A RS-232 None 3 Punch Down Block ETCO DD3C RS-232 Insulation Displacement or Punch Down Block Leviton 40066-M25 RS-232 Insulation Displacement 4 Cat5 Cable Assy. Installer N/A RS-232 RJ-45 Male X Wire 5 g! Controller Elan Various (ex. HC-12) RS-232 RJ-45 Female Use COM 1, 2, 3, etc. 4 of 8

OPTION 2: CONNECT MORE THAN FOUR THERMOSTATS WITH THE BOOSTER 6 RS-232 BOOSTER DB9F X RJ-45F Adapter 5 7 DB25M X DB9F Adapter Consult HVAC and HAI documentation for wiring details 8 DB9M X RJ-45F Adapter 9 Cat5 Cable Assy. 1 Thermostat 4 Cat5 Cable Assy. T-Stat 1 3 Punch Down Block 10 g! Controller T-Stat 2 RS232 PORT T-Stat 3 T-Stat 4 2 Cat5 Cable HVAC UNIT See Wiring Diagram 1 for details BILL OF MATERIALS # Device M anufacturer Part Number Protocol Connector Type Notes 1 Thermostat HAI RC-1000/RC-2000 RS-232 None 2 Cat5 Cable Installer N/A RS-232 None 3 Punch Down Block ETCO DD3C RS-232 Insulation Displacement or Punch Down Block Leviton 40066-M25 RS-232 Insulation Displacement 4 Cat5 Cable Assy. Installer N/A RS-232 RJ-45 Male X Wire 5 DB9F to RJ45 Adapter HomeLogic HA-CB-308 RS-232 DB-9 Female X RJ-45 Female 6 RS-232 BOOSTER HAI RC-202 RS-232 DB-25 Female X DB-9 Male 7 DB25M X DB9F Adapter Belkin F2L088 RS-232 DB-25 Male X DB-9 Female 8 DB9M to RJ45 Adapter HomeLogic HA-CB-307 RS-232 DB-9 Male X RJ-45 Female 9 Cat5 Cable Installer N/A RS-232 RJ-45 Male X RJ-45 Male Must terminate all 8 conductors 10 g! Controller Elan Various (ex. HC-12) RS-232 RJ-45 Female Use COM 1, 2, 3, etc. 5 of 8

THERMOSTAT SETUP Once the thermostats are powered up and running properly, you need to make a few changes to the thermostat to integrate with the g! system. STANDARD THERMOSTAT SETUP The changes outlined below in Table 1 assume that you are starting with a factory default thermostat. These changes will then put the thermostat into a standard g! setup. Step Instructions Comments 1 Remove the stat from the base then remove the Comm Jumper J8 if present. On newer hardware versions of the stat there is a jumper on the back of the stat that needs to be removed in order to communicate with g!. 2 Re install stat on the base and press the Dial to enter the Main Menu 3 Use the Dial to select and enter SETUP Firmware version will appear at bottom of SETUP 3 Use the Dial to enter INSTALLATION SETTINGS Press Continue on the warning message 4 Enter Thermostat Address Each thermostat must be assigned a unique address 5 Press OK to accept changes Returns you to INSTALLATION SETTINGS 6 Enter Communications Mode Use the Dial to alter fields and Next to move between 7 Set Communications to Serial and System Baud to 300. Expansion baud does not impact integration and can be set as needed or ignored. 8 Press OK to accept changes Returns you to INSTALLATION SETTINGS 9 Enter Program Settings 10 Set Program Mode to NONE This will disable internal schedules 11 Press OK to accept changes You may now BACK out of setup mode. Table 1: Steps to setup a factory default OMNISTAT 2 with standard g! settings. All other settings pertain to the stat itself or your HVAC system and may be set as desired. FIRMWARE AND HARDWARE VERSION INFORMATION g! requires each TStat to be using appropriate firmware. Please check and ensure your OMNISTAT 2 is using firmware version 1.03. Check your firmware by entering the SETUP menu as detailed in Step 2 above. If your version is not version 1.03, or no firmware appears listed in this area, contact HAI for assistance. This firmware update is particularly important if you are running the OmniStat 2 in Celsius, as earlier firmware contained a bug which causes odd readings and bad behavior. Please update to 1.03 by contacting HAI if you are running in Celsius. In newer hardware versions of the OmniStat2 have added a Comm Jumper J8 to the back of the stat. This jumper will need to be removed to communicate properly with g!. 6 of 8

g! CONFIGURATION DETAILS The following table provides settings used in the g! Configurator when connecting to an HAI thermostat network. Please refer to the Configurator Reference Guide for more details. In the table below: o <Select> Select the appropriate item from the list (or drop-down) in the Configurator. o <User Defined>, etc. Type in the desired name for the item. o <Auto Detect>, etc. The system will auto detect this variable. Devices Variable Name Setting Comments Communication Devices Name <Auto Detect> Type Serial Port Communication Type HAI Stand-Alone Thermostat Network Location <User Defined> (Not Required) Com Port <Select> COM1, 2, 3 etc. HVAC Units Name <User Defined> Model Generic HVAC Unit Controls Heat Controls Cooling Controls Fan <Discover Devices> Click the Discover Devices button on the Communication Device Thermostats Name <User Defined> Discover Devices will set a default name of "ThermostatID:1", etc. Location <User Defined> (Not Required) Com Device <Auto Detect> Thermostat # <Auto Detect> Heating Unit Cooling Unit Schedules HVAC Schedule 0, 1, 2 or 3 schedules Programs 1, 2, or 3 weekly programs Monday - Sunday <Select days> Select days that go together Periods per Day 1, 2 or 4 periods per day Global Options Units Fahrenheit or Celsius Temporary Hold Mode Timed Hold or Hold until next period Temporary Hold Default Time <Select> Outside Temperature Sensor Choose optional sensor if installed or choose Internet Outside Humidity Sensor Choose optional sensor if installed or choose Internet 7 of 8

COMMON MISTAKES 1. Programming two thermostats with the same address. 2. Failing to plug the Cat5 cable assembly into the correct serial port. Make sure the RJ-45 connector is plugged into the correct serial port as specified in the Configurator. 3. Configuring 2 subsystems with the same serial port. 4. Miswiring the Cat5 cables for the RS-232 connection. Be sure that you are following the EIA568B protocol, or if using the EIA568A, make sure you pay careful attention to Wiring Diagram 1. Remember that the CAT5 cable must be wired pin to pin, regardless of your wiring standard. 5. Using stats with incorrect firmware version. g! has tested firmware version 1.02c, and suggests using this version of firmware or newer. To alter firmware on your Thermostats please contact HAI. If you will be operating in Celsius your OmniStat 2 MUST be running version 1.03. 6. Not removing the Comm Jumper J8 on the back of the stat. See step 1 of Thermostat setup above. Note: Only newer model OmniStat 2 have this jumper 8 of 8