Analysis of Double-Ring Infiltration Techniques and Development of a Simple Automatic Water Delivery System

Similar documents
CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

Measurement of Soil Parameters by Using Penetrometer Needle Apparatus

RESEARCH. Effect of urban soil compaction on infiltration rate

EXPERIMENT 10 CONSTANT HEAD METHOD

METHOD OF TEST FOR DETERMINATION OF PERMEABILITY OF GRANULAR SOILS

KWANG SING ENGINEERING PTE LTD

A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil

Determination of Thermal Conductivity of Coarse and Fine Sand Soils

CHAPTER 2 HYDRAULICS OF SEWERS

Name: PLSOIL 105 & 106 First Hour Exam February 27, Part A. Place answers on bubble sheet. 2 pts. each.

PART I SIEVE ANALYSIS OF MATERIAL RETAINED ON THE 425 M (NO. 40) SIEVE

SOUTHWEST FLORIDA WATER MANAGEMENT DISTRICT RESOURCE REGULATION TRAINING MEMORANDUM

Storm Drain Inlet Protection for Construction Sites (1060)

PERMEABILITY TEST. To determine the coefficient of permeability of a soil using constant head method.

GUIDELINES FOR SOIL FILTER MEDIA IN BIORETENTION SYSTEMS (Version 2.01) March 2008

METHOD A10 (a) THE DETERMINATION OF THE IN-PLACE DRY DENSITY OF SOIL OR GRAVEL BY THE SAND REPLACEMENT METHOD

POWDER PROPERTIES LABORATORY

Attachment G-1: Pit Latrine Diagram. Fig E.1a: Pit Latrine. Fig E.1b: Plan View of Twin Pits

NC STATE UNIVERSITY PERMEABLE PAVEMENT RESEARCH AND CHANGES TO THE STATE OF NC RUNOFF CREDIT SYSTEM

oil liquid water water liquid Answer, Key Homework 2 David McIntyre 1

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Storm Drain Inlet Protection for Construction Sites (1060)

METHOD OF TEST FOR SAMPLING AND TESTING CRUMB RUBBER MODIFIER

#4.43 HYDRAULIC WASTEWATER LOADING RATES TO SOIL. E.J. Tyler* ABSTRACT INTRODUCTION

Appendix D.1. Testing Requirements for Infiltration, Bioretention and Sand Filter Subsoils

Effect of grain size, gradation and relative density on shear strength and dynamic cone penetration index of Mahi, Sabarmati and Vatrak Sand

Retention/Irrigation. Design Considerations. Soil for Infiltration Area Required Slope Environmental Side-effects

Hydraulic Conductivity Tests for Soils. Hsin-yu Shan Dept. of Civil Engineering National Chiao Tung University

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

The University of Toledo Soil Mechanics Laboratory

TEMPERATURE, CONCENTRATION, AND PUMPING EFFECTS ON PAM VISCOSITY

Surface Infiltration Rate of Permeable Pavements

Chapter D9. Irrigation scheduling

Preventing Basement Flooding

GUIDELINE FOR HAND HELD SHEAR VANE TEST

Apr 17, 2000 LAB MANUAL

Pervious Pavers: Where is the Perviousness?

[4] SA1.2 The student demonstrates an understanding of the processes of science by observing,

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!

Drainage Solutions and Water Treatment / Single-wall corrugated drainage tubing is ideal for agricultural and. Durable Economical Wide range of sizes

Standard Test Procedures Manual

FLUID FLOW Introduction General Description

2. THE TEORRETICAL OF GROUND PENETRATING RADAR:

For Water to Move a driving force is needed

Hydrologic Soil Groups

SOIL MECHANICS Assignment #4: Soil Permeability.

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

CHAPTER: 6 FLOW OF WATER THROUGH SOILS

EXPERMENTATIONAL DATA ANALYSIS OF CHIMNEY OPERATED SOLAR POWER PLANT

Geotechnical Investigation Reports and Foundation Recommendations - Scope for Improvement - Examples

Operations and Maintenance Guidelines for Coal Ash Landfills Coal Ash Landfills are NOT the Same as Subtitle D Solid Waste Landfills

Proper use of the Rebound Hammer Updated to reflect the changes to ASTM C805

Apr 17, 2000 LAB MANUAL PARTICLE SIZE ANALYSIS OF SOILS AASHTO Designation T 88 (Mn/DOT Modified)

Figure CPT Equipment

HIGHWAYS DEPARTMENT GUIDANCE NOTES ON SOIL TEST FOR PAVEMENT DESIGN

APPENDIX F. RESIDENTIAL WATER QUALITY PLAN: ALLOWABLE BMP OPTIONS

Section 2100-Trenching and Tunneling

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

Homework 9. Problems: 12.31, 12.32, 14.4, 14.21

SIEVE ANALYSIS OF FINE AND COARSE AGGREGATES

The University of Toledo Soil Mechanics Laboratory

Exposure of Copper in Äspö Groundwaters

BMP 6.7.3: Soil Amendment & Restoration

Drainage A Crucial Component for Athletic Field Performance. Part Three: Sub-Surface Installed Drainage Systems

GREEN ROOFS. Location. Design SMALL COMMERCIAL GUIDE CITY OF ATLANTA, GEORGIA DEPARTMENT OF WATERSHED MANAGEMENT

ITD Pipe Materials Selection & Specification Procedures. July 2011

HYDRAULICS. H91.8D/C - Computerized Open Surface Tilting Flow Channel - 10, 12.5, 15 and 20 m long

STANDARD SPECIFICATIONS SECTION PRECAST REINFORCED CONCRETE MANHOLES AND MANHOLE BASES. 1. Structure Earthwork: 02200

1.72, Groundwater Hydrology Prof. Charles Harvey Lecture Packet #2: Aquifers, Porosity, and Darcy s Law. Lake (Exposed Water Table)

CHAPTER 29 VOLUMES AND SURFACE AREAS OF COMMON SOLIDS

Emergency Spillways (Sediment basins)

APPLICATION FOR GRAYWATER IRRIGATION SYSTEM PERMIT SIMPLE RESIDENTIAL GRAVITY SYSTEMS, NO STORAGE

Standard Test Procedures Manual

Water Saving Technology

Section 2.0 : Construction and Measurement of a Simple Test Transmission Line

University of Florida Institute of Food and Agricultural Sciences. Gulf Coast Research and Education Center th Street East Bradenton, FL 34203

Low-cost Solar Desalinator

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

GAP CLOSING. Volume and Surface Area. Intermediate / Senior Student Book

GRADATION OF AGGREGATE FOR CONCRETE BLOCK

How to build raised beds page

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

ALUMINIUM SYSTEMS S.A.

S.3.6. BULK DENSITY AND TAPPED DENSITY OF POWDERS. Final text for addition to The International Pharmacopoeia

Geotechnical Investigation Test Report

Rain Gardens: Designing your Landscape to Protect Aquatic Resources. Curtis Hinman WSU Extension Faculty Watershed Ecologist

Prepared By: Tom Parker Geum Environmental Consulting, Inc.

ALPERTON COMMUNITY SCHOOL MATHS FACULTY ACHIEVING GRADE A/A* EXAM PRACTICE BY TOPIC

Landscape Irrigation Design Manual

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

Flash Flood Science. Chapter 2. What Is in This Chapter? Flash Flood Processes

Local buckling of plates made of high strength steel

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur

An Automatic Kunzelstab Penetration Test

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives

valid as of 1 April 2014 Intec injection hose system

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

Sample preparation for X-ray fluorescence analysis

CHAPTER 3: FORCES AND PRESSURE

Transcription:

2005 Plant Management Network. Accepted for publication 25 April 2005. Published. Analysis of Double-Ring Infiltration Techniques and Development of a Simple Automatic Water Delivery System Justin H. Gregory, Former Graduate Research Assistant, and Michael D. Dukes, Assistant Professor, Agricultural and Biological Engineering Department, University of Florida, Gainesville 32611; Grady L. Miller, Associate Professor, Environmental Horticulture Department, University of Florida, Gainesville 32611; and Pierce H. Jones, Professor, Agricultural and Biological Engineering Department and Director of the Program for Resource Efficient Communities, University of Florida, Gainesville 32611 Corresponding author: Michael D. Dukes. mddukes@ufl.edu Gregory, J. H., Dukes, M. D., Miller, G. L., Jones, P. H. 2005. Analysis of double-ring infiltration techniques and development of a simple automatic water delivery system. Online. Applied Turfgrass Science doi:10.1094/ats-2005-0531-01-mg. Abstract Double-ring infiltrometers are routinely used by turfgrass specialists, soil scientists, and other professionals to measure the infiltration rate of field sites. Measurement of infiltration rate is important in proper golf course design development and other scenarios that require estimates of runoff. This study compared several commonly performed double-ring infiltration methods as follows: 30- (inner) and 60-cm (outer) diameter rings with a constant water depth (head), 15- (inner) and 30-cm (outer) diameter rings with a constant head, and 15- (inner) and 30-cm (outer) diameter rings with a falling inner head. In addition, a Mariotte siphon device was fabricated to maintain a constant inner head for the 15-cm diameter rings. The 15- and 30-cm rings with the constant head resulted in significantly higher infiltration rates compared to 30- and 60-cm diameter rings with a constant head and 15- and 30-cm rings with a falling head. This was due to variation in the 30- and 60-cm test inner ring water level that had to be maintained manually and because of the non-constant water level in the 15- and 30-cm falling head test. Thus, we concluded that the constant head 15- and 30-cm double-ring test was adequate to represent the infiltration rate in the sandy soils tested. The Mariotte siphon device made it easy for one person to conduct a test while maintaining a constant inner head under infiltration rates ranging from 22 to 225 mm/h. Introduction Infiltration is the process by which water arriving at the soil surface enters the soil. This process affects surface runoff, soil erosion, and groundwater recharge. Being able to measure the surface infiltration rate is necessary in many disciplines. The double-ring infiltrometer is often used for measuring infiltration rates, and has been described by Bouwer (5) and by ASTM (3). These references contain standard guidelines for conducting double-ring infiltration tests; however, in practice a wide variety of testing methodologies are used. Ring infiltrometers consist of a single metal cylinder that is driven partially into the soil. The ring is filled with water, and the rate at which the water moves into the soil is measured. This rate becomes constant when the saturated infiltration rate for the particular soil has been reached. The size of the cylinder in these devices is one source of error. A 15-cm diameter ring produces measurement errors of approximately 30%, while a 50-cm diameter ring produces measurements errors of approximately 20% compared to the infiltration rate that would be measured with a ring of an infinite diameter (10). It has been suggested that a diameter of at least 100 cm should be used for accurate results (5). However, cylinders of this size become very difficult to use in practice on light soils, because large volumes of water are required to conduct tests on sandy soils with high infiltration rates.

Single-ring infiltrometers overestimate vertical infiltration rates (5,10). This has been attributed to the fact that the flow of water beneath the cylinder is not purely vertical, and diverges laterally. This lateral divergence is due to capillary forces within the soil, and layers of reduced hydraulic conductivity below the cylinder. A number of techniques for overcoming this error have been developed (such as a correction procedure that uses an empirical equation) for 15-cm diameter rings (10). Double-ring infiltrometers minimize the error associated with the single-ring method because the water level in the outer ring forces vertical infiltration of water in the inner ring. Another possible source of error occurs when driving the ring into the ground, as there can be a poor connection between the ring wall and the soil. This poor connection can cause a leakage of water along the ring wall and an overestimation of the infiltration rate. Placing a larger concentric ring around the inner ring and keeping this outer ring filled with water so that the water levels in both rings are approximately constant can reduce this leakage (5). The double-ring infiltrometer test is a well recognized and documented technique for directly measuring soil infiltration rates (3,5). Bouwer (5) describes the double-ring infiltrometer as often being constructed from thinwalled steel pipe with the inner and outer cylinder diameters being 20 and 30 cm, respectively; however, other diameters may be used. There are two operational techniques used with the double-ring infiltrometer for measuring the flow of water into the ground. In the constant head test, the water level in the inner ring is maintained at a fixed level and the volume of water used to maintain this level is measured. In the falling head test, the time that the water level takes to decrease in the inner ring is measured. In both constant and falling head tests, the water level in the outer ring is maintained at a constant level to prevent leakage between rings and to force vertical infiltration from the inner ring. Numerical modeling has shown that falling head and constant head methods give very similar results for fine textured soils, but the falling head test underestimates infiltration rates for coarse textured soils (12). The ASTM standard (3) describes a procedure for measuring the soil infiltration rate with a double-ring infiltrometer for soil with a hydraulic conductivity between 1 10-2 and 1 10-6 cm/s (360 mm/h to 0.036 mm/h). The ASTM standard specifies inner and outer diameters of 30- and 60-cm, respectively. There are also some minor differences in the method that is suggested by the standard compared to that described by Bouwer (5). The primary objective of this research was to compare falling head and constant head double-ring tests with 15- and 30-cm rings and a constant head test with 30- and 60-cm diameter rings. A secondary objective was to develop a simple device to automatically maintain a constant water level in 15-cm diameter inner ring. Infiltration Measurement Methods An area at the Irrigation Park on the University of Florida campus in Gainesville, Florida was used to conduct the double-ring infiltrometer tests. The area was approximately 5 m by 15 m and was covered by a permeable black plastic sheeting to prevent weed growth. This cover was removed for testing purposes. The soil was an Arredondo fine sand (11), which had been tilled and allowed to settle for several months. Soil textural analysis indicated 92% sand, 4.5% silt, and 3.1% clay (6). The three types of tests that were evaluated were the ASTM standard 30-cm (inner) and 60-cm (outer) double-ring infiltrometer under a manually maintained inner ring constant head (A), 15-cm (inner) and 30-cm (outer) infiltration rings under an inner ring constant head with a Mariotte siphon (B) and 15-cm (inner) and 30-cm (outer) infiltration rings under a falling head (C). In all three types of tests, the outer ring was maintained manually at a constant head. Maintaining a constant head in the outer ring was not as critical as maintaining constant head in the inner ring to measuring infiltration rates since the purpose of this head is to reduce the leakage of water between rings. The 15- and 30-cm infiltration ring size is typically used in turfgrass systems such as golf courses for infiltration measurements. In many cases, the falling head test is preferred since less water and time are required to complete a test.

A total of eight tests in different locations within the experimental site were conducted using method (A), which followed the procedure set out by the ASTM standard. Nine infiltration tests each were conducted using methods (B) and (C). One fewer of the method (A) tests was conducted because substantially more water was required for this test compared to the smaller rings and not enough water was available to run the final test with the large rings. Both the small (15 and 30 cm) and large (30 and 60 cm) sets of double rings were manufactured out of 2.5- mm thick aluminum (Fig. 1). These rings were driven into the ground approximately 15 cm for (A) and 5 cm for (B) and (C) using an 18-kg hammer and a 10- -10- -75-cm block of wood. A Mariotte siphon was manufactured from a 10.2-cm inner diameter Plexiglass pipe cut to a length of 120 cm (Fig. 1). This resulted in approximately Fig. 1. Photograph of (A) 30-cm diameter (inner) and 60-cm diameter (outer) double-ring infiltrometer (B) 15-cm diameter (inner) and 30-cm diameter (outer) double-ring infiltrometer, and (C) Mariotte siphon developed to maintain a constant inner head in the infiltration rings. 12.5 liters of water storage, sufficient to keep a constant head in a 15-cm diameter inner ring for more than 4 h assuming an infiltration rate of 150 mm/h and for 1 h assuming an infiltration rate of 700 mm/h. The 30- cm diameter inner ring used in the ASTM Standard test would require approximately 50 liters of water to keep a constant head for 1 h assuming an infiltration rate of 700 mm/h. Two 130-mm PVC end caps were used to seal both ends of the Plexiglass pipe and a wooden base was built to support the siphon. A barbed pipe fitting was tapped into the bottom PVC end-cap and a 20-mm diameter hole was drilled into the top endcap. A 1.5-m long, 15-mm diameter PVC pipe was then placed within the siphon (Fig. 2) and a rubber stopper was used to create an airtight seal between the end-cap and pipe. Adjusting the level of the tube allowed the pressure at the outlet of the siphon to be either increased or decreased. The height of the bottom of the pipe above the siphon outlet was equal to the water level in the inner ring of the infiltrometer. A graduated tape was placed on the outside of the siphon to allow the water level in the siphon to be recorded at a regular time interval. The water level in the outer ring was maintained manually by adjusting a flow valve on a water container (38 liters) that was used to supply water to the outer ring of the double-ring infiltrometer. Alternatively, another Mariotte siphon could be used to maintain a constant water level in the outer ring; however, the water level could be maintained manually with sufficient precision to minimize lateral flow or leakage from the inner ring. Cumulative infiltration and time were recorded, with each test generally lasting 40 to 90 minutes for the constant head test and approximately 20 to 30 minutes for the falling head test. The bulk density and volumetric moisture content of the soil were measured adjacent to each test site before each infiltration test was conducted using standard laboratory procedures (1,2,4,8). The infiltration rate was found by regressing the recorded cumulative infiltration and time data using Sigma Plot (SPSS, Chicago, IL). The GLM procedure in SAS (SAS Institute, Inc., Cary, NC) was used to produce an Analysis of Variance (ANOVA) to test for statistical differences between infiltration rates and Duncan s Multiple Range Test was used for means separation.

Fig. 2. Mariotte siphon developed for infiltration rate testing with 15- and 30-cm inner and outer rings of a double-ring testing apparatus. Dimensions in millimeters. Evaluating Measured Infiltration Rates Table 1 shows the results of the measured infiltration rates from the three different testing methods. Measured infiltration rates on the sandy soil ranged from 22 to 225 mm/h and averaged 143 mm/h over all tests (Table 1). These rates are representative of moderately compacted fine sandy soils such as has been documented on pasture sites (9). Testing methods (A) and (C) resulted in a significantly lower mean infiltration rate (119 and 128 mm/h, respectively) compared to method (B) at 179 mm/h (P = 0.0492) (Table 2). This difference was expected for the falling head test (C) since the depth of water in the inner ring, one of the components of total head which causes infiltration, decreases during the test. This result is similar to results reported by Wu et al. (12). However, it is unknown why the large rings at constant head resulted in lower infiltration rates. One possibility is that the large volume of water required to maintain water level in the inner ring was manually controlled; therefore, contributing to an increase in the incidence of human error since the larger the volume of water that is manually added the more difficult it is to be precise in the application of that water. Test (B) had the lowest CV at 24% compared to tests (A) and (C) at 39% and 37%, respectively. It was observed that one test with (A) and one with (B) resulted in infiltration rate outliers. Using boxplots, these values were between one and a half and three box-lengths from the 25th percentile (7).

Table 1. Statistical analysis of infiltration rates (K) from three types of infiltration tests z. Test A ASTM standard with 30- and 60-cm dia. rings x Test B Constant head with 15- and 30-cm dia. rings x Test C Falling head with 15- and 30-cm dia. rings x Test no. K (mm/h) Test no. K (mm/h) Test no. K (mm/h) 1 120 1 79 1 161 2 147 2 225 2 56 3 110 3 171 3 128 4 164 4 196 4 100 5 N/A y 5 209 5 186 6 86 6 190 6 80 7 152 7 201 7 197 8 152 8 151 8 119 9 22 9 192 9 125 Mean 119 Mean 179 Mean 128 Std dev 47 Std dev 43 Std dev 47 CV 39% CV 24% CV 37% z Note, the overall mean infiltration rate was 143 mm/h, with a standard deviation of 52 mm/h and a CV of 36%. y Test 5 for (A) not conducted. x Note that 15- and 30-cm rings refer to inner and outer ring diameters, respectively and 30- and 60-cm ring diameters refer to inner and outer ring diameters, respectively. Table 2. Results of an ANOVA for measured infiltration rates using different testing methodologies (tmt = infiltration test and rep = replication). Source Type III sum of squares DF Mean square F Pr > F tmt 161.8 2 80.9 3.71 0.0492 rep 151.8 8 19.0 0.87 0.5624 error 327.5 15 21.8 Although the outliers observed in (A) and (B) are commonly found in infiltration testing (9), they were removed and the analysis was repeated. Test (B) still had a mean infiltration rate (192 mm/h) higher than tests (A) and (C) (133 and 128 mm/h, respectively). Test (B) infiltration rate remained significantly higher (P = 0.0180) than (A) and (C). By removing the outliers in the two tests, the overall CV was reduced to 19%. Volumetric moisture was not significantly different across testing locations with all data or with the outliers removed (P = 0.0789 and P = 0.1073, respectively). Soil bulk density was not significant across testing locations in the full data set (P = 0.0789) but was significant when the outliers were removed (P = 0.0278). Test (A) sites had a higher soil bulk density of 1.53 g/cm 3 in the upper 6 cm compared to test (C) at 1.47 g/cm 3. Bulk density at (A) was similar to test (B) at 1.50 g/cm 3. Although soil bulk density was higher on (A), there was not a correlation with infiltration rate over all tests (r = 0.1893) or with outliers removed (r = 0.1394). In addition, tests of covariance between soil moisture content and infiltration rate and between soil bulk density and infiltration rate indicated no covariance between infiltration rate and soil moisture or soil bulk density.

A typical 15- and 30-cm ring test required approximately 60 liters of water (inner and outer ring) and the constant head was easily maintained with the Mariotte siphon. As previously mentioned, the constant head in the large ring (30 and 60 cm) tests was maintained manually. This required a substantial amount of water to be manually added (approximately 115 liters), thus the actual head maintained varied. Summary of Infiltration Studies The use of smaller diameter inner and outer rings (15 and 30 cm, respectively) with a constant head provided results that were statistically higher than the ASTM standard test and the falling head test with small rings. Both the ASTM and the falling head tests resulted in higher CVs than the 15- and 30-cm ring constant head tests. This trend was more evident when outliers from the data set were removed. A higher soil bulk density on ASTM ring testing sites coupled with human error at maintaining the water level in the inner ring contributed to the high variability in this test. It was concluded that the test using a constant head with a double-ring infiltrometer of 15-cm inner diameter and 30-cm outer diameter would be suitable for infiltration research on the sandy soils generally found in North Central Florida. Previous measurements indicate these soils have similar infiltration rates to golf greens built to USGA specifications with mature turf (data not shown). This allows for infiltration tests to be conducted in areas where a methodology such as that specified by the ASTM would not be suitable due to insufficient spacing between obstacles or because the volume of water required to maintain a constant head in the larger diameter double-ring infiltrometers can not be transported to remote sites. The set-up of the double-ring infiltrometer with the Mariotte siphon, as described in this paper is an efficient method of conducting a double-ring infiltrometer test. The Mariotte siphon automatically maintains a constant head in the inner ring, while the head in the outer ring is maintained manually (a second Mariotte siphon could be used for this). This testing procedure therefore only requires one person to maintain the head in the outer ring and record the change in water level in the siphon. The volume of water that is needed for this tests can also be managed by a single person compared to the large volume of water needed to conduct the ASTM standard test. Acknowledgments This research was supported by the Florida Agricultural Experiment Station and a grant from the St. Johns River Water Management District and approved for publication as Journal Series No. R-10708. Literature Cited 1. ASTM. 2002. D2216-98: Standard test method for laboratory determination of water (moisture) content of soil and rock by mass. Annual Book of ASTM Standards 04.08. Amer. Soc. Testing Materials, West Conshohocken, PA. 2. ASTM. 2002. D2937-00: Standard test method for density of soil in place by the drive-cylinder method. Annual Book of ASTM Standards 04.08. Amer. Soc. Testing Materials, West Conshohocken, PA. 3. ASTM. 2003. D3385-03 Standard test method for infiltration rate of soils in field using double-ring infiltrometer. Annual Book of ASTM Standards 04.08. Amer. Soc. Testing Materials, West Conshohocken, PA 4. Blake, G. R., and Hartge, J. H. 1986. Bulk gensity. Pages 363-375 in: Methods of Soil Analysis, Part I, ASA Monograph 9. ASA. Madison, WI. 5. Bouwer, H. 1986. Intake rate: Cylinder infiltrometer. Pages 825-843 in: Methods of Soil Analysis. A. Klute, ed. ASA Monograph 9. ASA. Madison, WI. 6. Carlisle, V. W., Hallmark, C. T., Sodek, F., III, Caldwell, R. E., Hammond, L. C., and Berkheiser, V. E. 1981. Characterization Data for Selected Florida Soils. Soil Science Res. Rep. 81-1. Univ. Florida, Insti. Food and Agric. Sci., Gainesville, FL. 7. Devore, J. L. 1995. Probability and Statistics for Engineering and Sciences. 4th ed. Duxbury Press, Boston, MA. 8. Gardner, W. H. 1986. Water content. Pages 493-544 in: Methods of Soil Analysis. Part I, ASA Monograph 9. ASA. Madison, WI.

9. Gregory, J. H. 2004. Stormwater infiltration at the scale of an individual residential lot in North Central Florida. M.E. Thesis, Agricultural and Biological Engineering Dept., University of Florida. 10. Tricker, A. S. 1978. The infiltration cylinder: Some comments on its use. J. Hydrol. (Amsterdam) 36:383-391. 11. USDA. 1985. Soil Survey of Alachua County, Florida. United States Dep. Agric., Natural Resource Conserv. Ser., Washington, DC. 12. Wu, L., Pan, L., Robertson, M., and Shouse, P. 1997. Numerical evaluation of ring infiltrometers under various soil conditions. Soil Sci. 162:771-777.