APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class # 2010



Similar documents
Custody Transfer Measurement. with the V-Cone Flowmeter

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

The Unique Accelabar Flow Meter

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Energy and Flow Measurement for Hydronic Systems

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

AN INSTRUMENT FOR GRAVIMETRIC CALIBRATION OF FLOW DEVICES WITH CORROSIVE GASES. J. O. Hylton C. J. Remenyik Oak Ridge National Laboratory *

Steam System Best Practices Condensate System Piping

Typical Aluminum GFM Mass Flow Meter

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

Gas Custody Transfer Calibration

4 Posiflow Proportional Solenoid Valves

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Oil and Gas Custody Transfer

Fundamentals of Mass Flow Control

Using meters to measure steam flow

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter

Coriolis Flow meters. Product family introduction Principle of operation Product review Applications Key product features

In-Line Electronic Flow Switches

INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

Density Measurement. Technology: Pressure. Technical Data Sheet INTRODUCTION. S min =1.0 S max =1.2 CONSTANT LEVEL APPLICATIONS

OPTIMASS 1400 Technical Datasheet

Solartron density transducers

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level B

Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2

Micro Motion 3098 Gas Specific Gravity Meter

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

Rosemount Orifice Plate in Wet Gas

Procon Engineering. Technical Document PELR TERMS and DEFINITIONS

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

PULSATION REDUCTION BY ACOUSTIC FILTERS FOR METERING APPLICATIONS. Robert J. McKee Ray G. Durke

Industrial Steam System Process Control Schemes

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

Flow Measurement Options for Pipeline and Open Channel Flow

GOOD PRACTICE GUIDE THE CALIBRATION OF FLOW METERS

Sentinel I28 and Blackbelt Mass Flow Calibration and Verification

FLOW COMPUTERS METERING, MONITORING, & DATA ACQUISITIONS. Sami Halilah Dynamic Flow Computers Houston, Texas

APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS

Fiscal Measurement Natural Gas

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

STANDARD CLEANING AND CALIBRATION PROCEDURE FOR TGA-50(H) AND TGA-51(H)

TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES. Randall Messman SW Regional Sales Manager

OIL & GAS PRODUCTION AUDITING

Correcting a Coriolis Meter for Two Phase Oil & Gas Flow

In-Line Electronic Flow Switches

Thermal Dispersion Mass Flow

Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF

Density and Refractometry

TABLE OF CONTENT

Advances in Thermal Dispersion Mass Flow Meter Accuracy

EDD-600 FLOW TOTALIZER RATE INDICATOR OPERATION MANUAL. P.O. Box Odessa, Texas USA.

OPTIMASS 6000 Technical Datasheet

LAB #3: MEASURING SPECIFIC GRAVITY AND DENSITY. Set-up and Materials for Experiment

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Micro Motion ELITE CMFS Series Meter

Daniel Venturi Tubes and Flow Nozzles Brochure

AN IN-SITU VERIFICATION TECHNOLOGY FOR CORIOLIS FLOWMETERS

HEAVY OIL FLOW MEASUREMENT CHALLENGES

Turbine Flowmeters for Gas Applications

ORIFICE PLATES. CONCENTRIC BORE: For standard fluid conditions an Orifice Plate would have a centrally located orifice bore.

THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT page 1 THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT INTRODUCTION COEFFICIENT OF DISCHARGE

When the fluid velocity is zero, called the hydrostatic condition, the pressure variation is due only to the weight of the fluid.

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

FLUID FLOW Introduction General Description

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

Experiment # 3: Pipe Flow

TABLE OF CONTENT

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

A Practical Overview of Level Measurement Technologies

Three Methods for Calculating the Buoyant Force Gleue: Physics

Select the Right Relief Valve - Part 1 Saeid Rahimi

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Theory, Application, and Sizing of Air Valves

Practical Application of Industrial Fiber Optic Sensing Systems

Overview. Inficon s Product

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

Variable V Area Flowmeter Rotameter The Original

Gravimetric determination of pipette errors

Simulation of Process Conditions for Calibration of Fisher Level Controllers and Transmitters Supplement to 249 Sensor Instruction Manuals

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Energy transformations

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Chapter Test B. Chapter: Measurements and Calculations

T U R B I N E G A S M E T E R

How To Install A Mazzei Injector

CCST Exam Preparation Course Syllabus

Transcription:

APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class # 2010 Colin B. Blakemore Sr. Product Specialist Pipeline & Gas Measurement Products AMETEK Process Instruments 455 Corporate Boulevard Newark, Delaware USA INTRODUCTION One of the many parameters that must be accurately measured for product quality control, custody transfer, process control, or liquid interface detection purposes is liquid density. Often, density measurement is combined with flow measurement to determine the mass flow rate of a liquid in a pipeline. In this article, we will discuss the principle of operation of vibrating tube densitometers, design suggestions for densitometer installation, and calibrating, or "proving", the system. DENSITOMETER TYPES There are different types of densitometers in use today. Some of the various operational principles in use for these devices are listed as follows: Vibration Buoyancy Nuclear Acoustic Each operational principle has advantages and disadvantages. The selection of the densitometer type usually depends on the application, performance requirements, and budget. In this article, we will restrict our discussions to vibrating tube densitometers. THEORY OF OPERATION The simplest vibrating system consists of a spring and mass mechanically connected together as shown in Figure 1. If the mass is displaced and released, the system will vibrate at a known frequency defined by the following equation, SPRING MASS where, k = spring constant m = total mass Frequency = 147 1 2π k m

If the spring constant, k, or the mass, m, changes, the frequency of vibration, or the "natural frequency", will change. This concept can be related to a vibrating tube densitometer. The spring constant is related to the stiffness of the tubing. The mass is related to the mass of the tubing plus the mass of the liquid inside the tubing. As the mass (or density) of the fluid in the tubing varies the natural frequency varies VIBRATING TUBE DENSITOMETERS Figure 2 A vibrating tube densitometer is basically a spring-mass system where the frequency of vibration of the tubing is measured and related to the fluid density. The tube assembly is supported at each end and is mechanically "excited" or "displaced" using electro-mechanical devices so that the assembly will vibrate at the natural frequency. As previously discussed, the frequency of vibration of the tube assembly will vary as the density of the fluid in the tubing changes. The tube assembly must have appropriate mechanical properties to resist corrosive attack from the fluid, contain the pipeline pressure, and have desired vibration characteristics. The actual arrangement of the tubes will vary with manufacturer, with parallel tubes, U-tube, and in-line tubing being the most common. The tube material is usually Ni-Span C, Stainless Steel, or Hastelloy although other materials have been used. An efficient densitometer installation design will ensure that a representative liquid pipeline sample is located inside the tube(s) at all times. The following equation is used to relate the frequency of vibration of the tubing to the actual fluid density: Uncorrected Density = K 0 + K1t + K2t 2 Where, K 0 = Calibration coefficient K 1 = Calibration coefficient K 2 = Calibration coefficient t = 1/frequency = Period of vibration For increased accuracy, compensation for the effects of changing temperature, T, and pressure, P, on the tubing must be performed. To relate to the spring-mass example, the changes in pipeline T and P cause small changes 148

to the stiffness of the spring, causing variation in the frequency of vibration. In most cases, the frequency shift caused by changing temperature and pressure can be described with second-order equations with coefficients that are unique for each densitometer. The coefficients used in these equations are supplied by the manufacturer when the densitometer is purchased or re-certified. During field calibration, or proving, of the densitometer, a density correction factor, DCF, is used to adjust the indicated, or observed, density of the densitometer to the actual density of the liquid. If the DCF varies beyond manufacturer recommendations, or the accuracy varies with the fluid density, the densitometer must be examined for possible defects and re-certified. DENSITOMETER SIGNAL PROCESSING The signal output from a vibrating tube densitometer is a "square wave" signal with a frequency equaling the vibration frequency of the tube assembly. From this signal, the frequency must be measured, and the corrections for the effects of fluid temperature and pressure must be applied. The final determination is the density of the fluid. A computer is used to perform these calculations. In many cases, the computer is also measuring the pipeline fluid flow rate using a turbine flow meter, an orifice meter, or other flow measurement device. Using the accumulated data, the fluid mass flow rate can be determined. Depending on the application, the flow computer output values may be transferred to another computer or process via 4-20 ma signals, or through the use of a communication network (Fieldbus, Profibus, Modbus, HART, etc...) DENSITOMETER INSTALLATION The performance of a densitometer is highly dependent on the design of the installation. The following items must be considered during the design phase (Ref. Figures 3 and 4): Flow rate. Densitometers may be connected in parallel (bypass) or series (inline) to a pipeline. When connected in series, the maximum flow rate through the densitometer must be considered. Densitometers are usually connected in parallel to the pipeline using a "bypass loop" if the pipeline flow rate is high. In this case, the flow rate in the loop must be sufficient to provide a representative liquid sample from the pipeline, through the densitometer, and back to the pipeline. If this flow rate is too low, the time required to sense a change in pipeline density may be excessive and erratic density readings may occur. The flow rate through the densitometer bypass loop is created using "scoops" in the main pipeline to induce flow. The differential pressure between the inlet and discharge scoops of the loop must be sufficient to induce adequate flow. In some cases, an orifice plate must be used to increase the differential pressure and the loop flow rate. Liquid phase Unless stated otherwise, most densitometers are intended for use with single-phase fluids. Unpredictable density measurements result if the liquid consists of varying mixtures of liquid and gas. Distance from pipeline and related flow measurement devices The distance between the densitometer, the pipeline, nometer connections, temperature and pressure measurements, and flow measurement devices must be minimized. By reducing these distances, the pressure drop through the bypass loop is minimized and the temperature of the entire system is uniform. Densitometer insulation The insulation of the densitometer and bypass loop is critical to provide a uniform temperature at the densitometer, at the nometer, and at the flow measurement site (turbine flow meter or orifice plate). Orientation The orientation of the densitometer is usually vertical or horizontal. The densitometer manufacturer has specific guidelines for performance in all orientations. Pycnometer connection An insulated secondary flow loop must be provided for the nometer upstream of the densitometer in the primary flow loop. This loop is used when the densitometer must be proved (i.e. calibrated). Thermowells and pressure transducers The final accuracy of the density and mass flow measurement is also dependent on the accuracy of the temperature and pressure measurements. The location of these measurements and the stability of the readings must be carefully considered. 149

DENSITOMETER PROVING To verify the accuracy of the entire system, a densitometer must be calibrated or "proved" periodically. The device used to perform this calibration is known as a "nometer". A nometer is a precision sphere of known mass and volume that is capable of withstanding pipeline pressures. The nometer is recommended for use by API for densitometer proving. During the proving of a densitometer, the nometer is connected in series or parallel with the densitometer. Once temperature stability (±0.2 F) has been achieved at all locations in the flow loop, the nometer is removed and weighed. Once the "tare mass" or empty mass of the nometer has been subtracted, the liquid mass per unit volume, or density is calculated. This test is normally repeated until the readings are repeatable. Once this occurs, the density value is used to calculate the "density correction factor", DCF, and is used to calculate the actual density in the flow computer or signal converter. The following equations are used: Density DCF = Density Density = obs M - M V where, Density = Pycnometer density M = Pycnometer mass (filled with fluid M empty = Pycnometer empty mass (under vacuum) V = Pycnometer volume (corrected) Density obs = Observed density A certified, traceable weighing device must be used to determine the mass of the nometer. For optimum accuracy, verify the calibration of the weighing device using certified masses before proving a densitometer. Since the nometer empty mass is determined at standard temperature and pressure, and standard gravity (980 cm/sec ), compensation for a difference in buoyancy at local ambient conditions and local gravity must be applied to the weight values. See Reference 1 for a standard on density proving using a nometer. empty GLOSSARY Density: The mass per unit volume of a gas or liquid. Relative density (Specific gravity): For a gas, the ratio of the density of the gas to the density of air at standard temperature and pressure. For a liquid, the ratio of the density of the liquid to the density of water at standard temperature and pressure. Standard Temperature and Pressure: The standard (reference) temperature and pressure at which gas volumes are calculated. In the U.S., the base temperature is 60 F and the base pressure will vary (14.65, 14.696, 14.73 Psia) depending on local standards. When comparing gas volumes, verify that the base conditions are the same. Mass: A quantity of matter. Matter is any material that occupies space and has mass. Weight: The force with which mass is attracted to earth due to local gravity. Weight = Mass x Local gravity (Gc) 150

REFERENCES 1. API "Manual of Petroleum Measurement Standards", Chapter 14, Section 6. Figure 3. Figure 4 151