Light Steel Modular Construction



Similar documents
Best Practice in Best Pra ctice in teel constr uction - onstr industrial B uildings esidential Buildings 01 Introduction 02 Key Design Factors

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Rockwool Flexi Insulation Application Guide

Timber Frame Construction

PART 1 GENERAL 1.1 SECTION INCLUDES

Composite Panel Firewall Systems

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

Timber frame structures platform frame construction (part 1)

Scope of EN Clarification Document

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

STEEL BUILDINGS IN EUROPE. Multi-Storey Steel Buildings Part 2: Concept Design

INSTALLATION. General. Important Note. Design. Transport

Partitioning & Ceiling Product Information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 6 ROOF-CEILING SYSTEMS

Residential Deck Safety, Construction, and Repair

POST AND FRAME STRUCTURES (Pole Barns)

How To Certify The Scottsdale Construction System

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

WI LEY Blackwell. Multi-storey Precast Concrete Framed Structures. Colin K. Jolly MSc, PhD, CEng, MICE, FIStructE

H-Stud Area Separation Wall System

Formwork for Concrete

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Energy Company Obligation (ECO): Technical Monitoring Questions

Steel joists and joist girders are

Detailing of Reinforcment in Concrete Structures

Contents. 01 Introduction Key Design Factors. 03 Floor Systems. 04 Special Floor Systems Beam Connections.

8/18/14. Introduction to. Framing. Terminology and Concepts

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Bracing Webs in Trusses that have Dissimilar Configurations

Rockwool Cladding Roll

FCA CARPENTRY & JOINERY THEORY. 10 SIMPLE ROOF CONSTRUCTION Part 2

Multi-layer Insulation Blanket for Roofs

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

Common Errors in Truss Design

Fire. The Fire Installers Mate. A guide to fire alarm systems design

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Eurocode 5: Design of timber structures

Hanson Building Products. precast basement solutions

Page & Turnbull imagining change in historic environments through design, research, and technology

Technical Notes 3B - Brick Masonry Section Properties May 1993

sound reduction systems for commercial, educational and industrial environments

Timber Frame Walls Rethinking Construction

Technical Assignment 2 TABLE OF CONTENTS

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Mark Cramer Inspection Services, Inc.

Project Report. Structural Investigations Hotel del Sol Yuma, Arizona

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

SIMPLE SAVER SYSTEM DESIGN MANUAL

Welded Fabric. The CARES Guide to Reinforcing Steels Part 5. Installation of welded fabric on a major contract. 1.0 Introduction

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

EAST LYME HIGH SCHOOL

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

Peninsula Place, Greenwich, London

UNIVERSAL RAILING, STEEL

Lightweight Partition Design for Residential and Commercial Buildings

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

COLUMN-FREE OFFICE SPACE RISES IN CHICAGO S LOOP

March 14, Installation of Bay, Bow and Garden Windows

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

Services Enclosures and Protected Shafts - Maintaining Compartmentation

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

WORLD S TALLEST TIMBER BUILDING, BERGEN

Residential Decks. Planning and Development Services Department

Fire safety in timber buildings

PANELIZED HOME INSTALLATION GUIDELINE

Superform Products Ltd.

SUPER SHED. Indoor shelter for your outdoor tools.

Building Systems by Stora Enso. Residential multi-storey buildings

Excerpts from the Canadian National Building Code (NBC)

Module 3.7. Thermal bridging

Certification: Building Plans Examiner. Exam ID: B3

Installation Window Building In Details

Brock Commons Phase 1 University of British Columbia, Vancouver, Canada

Section A Roof Truss

Timber Decks. Technical Note. March 2007

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

FIRE RATED GLAZING System Guide

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

Building Control Guidance Note

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

6 RETROFITTING POST & PIER HOUSES

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

Chapter. Earthquake Damage: Types, Process, Categories

SCHEMATIC AND PROJECT BUDGET APPROVAL EAST CAMPUS NURSING EDUCATION AND CLASSROOM

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Connection Solutions

Transcription:

Technical Information Sheet ED014 Light Steel Modular Construction R M Lawson BSc PhD CEng MICE MIStructE MASCE ACGI This Information Sheet reviews the various forms of building modules constructed using light steel framing and presents examples of where modular construction has been used. It reviews the basic principles of design using modular construction and addresses the basic dimensions, design requirements and interfaces with cladding, services and other details. Key benefits The benefits of modular construction are: y Economy of scale by manufacture of multiple similar modular units. y Speed of construction, which is up to 50% faster than traditional methods. y High level of quality control through off-site manufacture. y Minimum disturbance to the locality during construction. y Detailed design work is carried out by the modular supplier. y Suitable where site constraints may limit deliveries needed for other more traditional methods of building. y Elimination of on-site waste; waste in the factory can be recycled more easily. y Suitability for roof-top extensions in building renovation. y Specialist equipment and services may be commissioned and tested in the factory, which is important in hospital projects. y Modules may be moved in the future as demand changes. High-rise modular building, London (Image courtesy of Futureform and Ayrshire Framing) Three storey modular office building (Image courtesy of BW Industries) Modular construction The use of modular and other lightweight forms of building construction is increasing. The benefits of off-site prefabrication and improved quality in manufacture are being realised for residential buildings, for mixed use projects (e.g. commercial with housing), educational and health sector buildings. The various design issues related to compliance with the Building Regulations, including structural design, acoustic and thermal insulation, are presented in detail in the SCI publication: Residential Buildings using Modular Construction (P302). Modular residential building (Image courtesy of Lightspeed Construction Ltd) The main sectors of application of modular construction are: y Private and social housing y Apartments and mixed use buildings y Educational sector and student residences y Key worker accommodation and sheltered housing y Public sector buildings, such as prisons and MoD buildings y Health sector buildings y Hotels. 1

Four Sided Modules Form of construction Four-sided modules are manufactured with four closed sides to create cellular type spaces and are designed to transfer loads through their longitudinal walls. The modules are designed for the combined vertical load from the modules above and in-plane loads due to wind action. The maximum height of buildings in foursided modular construction is typically 6 to10 storeys, depending on location and exposure to wind loading. However, taller buildings can be achieved when modules are combined with a concrete or steel core. Figure 1 Four sided module (with staggered end) (Image courtesy of Ayrshire Framing) Cellular buildings, such as hotels, student residences, residential buildings and key worker accommodation. Modules are manufactured from a series of 2D panels, beginning with the floor cassette, to which the four wall panels and ceiling panel are attached. The walls transfer vertical loads and therefore the longitudinal walls of the upper module are designed to sit on the walls of the module below. An example of a four-sided module is illustrated in Figure 1. Modules are essentially four sided volumetric units with openings in their ends for windows and doors. Their external width is limited by transportation requirements to approximately 4 m (3 to 3.6 m is the typical internal module width for most applications). The module length is typically 6 to 15 m. The light steel walls typically use 65 to 100 mm deep C sections. Bracing and lateral stability The bracing system required generally depends on the geometric form of the building. Various solutions are used: y For low rise buildings, in plane bracing or diaphragm action of the board materials within the modules can be sufficient. y For buildings of 6 to 10 storeys height, a vertical bracing system is often located around an access core, and assisted by horizontal bracing in the corridor floor between the modules. y For taller buildings, a primary steel podium frame may be provided on which the modules are stacked and supplemented by a concrete or steel core. The maximum height of a modular building is generally limited by the compression resistance of the members in the walls and by the bracing in the walls. Additional steel angle members may be introduced in the corners of the modules for lifting. The floor joists are typically 150 or 200 mm deep, and the combined floor and ceiling depth is in the range of 300 to 450 mm. Figure 2 Long four-sided module with an integral corridor (Image courtesy of Kingspan) 2

Partially Open-Sided Modules Form of construction Modules can be designed with partially open sides by the introduction of corner and intermediate posts and by using a stiff edge beam in the floor cassette. Additional intermediate posts are usually square hollow sections of small cross-section, so that they can fit within the wall. Two modules can be placed together to create wider spaces. The compression resistance of the corner or internal post is critical in the structural design. Typically, 6 to 10 storeys can be achieved, as for four-sided modular construction. Long modules can also be designed to include an integral corridor, as shown in Figure 2. This approach can avoid weather tightness problems during installation and finishing work. Key worker accommodation, small apartments, hotels with corridors, communal areas in student residences. Technical Details Details are similar to four sided modules, except for the use of additional posts, generally in the form of 70 70 to 100 100 SHS steel members. Overall stability and transfer of horizontal forces is provided by additional bracing located in the walls of the modules. Balconies or other components can be attached to the corner or internal posts. The edge beams in the floor cassette can be designed to span 2 to 3 m to create openings in the sides or ends of the module. An example of the arrangement of partially and fully open-sided modules in a school building is shown in Figure 4. Stability of the modules is affected by their partially open sides; additional temporary restraints may be necessary during transport and installation. A separate bracing system may also be required, as the partially open-sided modules may not possess sufficient shear resistance in certain applications. Classroom 3 Classroom 4 Store Hygiene Room Office Girls Toilet Lobby Boys Toilet Store Plant Room Classroom 1 Classroom 2 Figure 3 Partially open sided modules (Image courtesy of Futureform and Ayrshire Framing) Figure 4 Layout of school building using partially and fully open sided modules (alternate modules are shown shaded) (Image courtesy of BW Industries) 3

Open-Sided (Corner Supported) Modules Form of construction Modules may be designed to be fully open on one or both long sides by transfer of loads to the corner posts. This is achieved by bending of the longitudinal edge beams. The framework of the module often uses Square Hollow Section (SHS) columns and Parallel Flange Channel (PFC) edge beams that are bolted together. Modules can be placed side by side to create larger open plan spaces, as required in hospitals and schools etc. The stability of the building generally relies on a separate bracing system (usually of X bracing) in the separating walls. For this reason, fully open sided modules are not often used for buildings more than three storeys high. Schools and hospitals in low-rise buildings. Residential buildings with variable room sizes. The corner posts provide the compression resistance and are typically 70 70 to 100 100 SHS. The edge beams may be connected to these posts by fin plates, which provide nominal bending resistance. The corner posts possess sufficient compression resistance for use in buildings up to 10 storeys. As open sided modules are only stable on their own for one or two storeys, additional bracing is usually introduced vertically and horizontally. In plane forces can be transferred by the floor and ceiling cassettes and by suitable connections at the corners of the modules. Typical details of the internal framework of an open sided module using PFC beams and SHS posts are shown in Figure 6. Installation of open sided modules in a hospital building is shown in Figure 7. Modules using a hot-rolled steel framework can be designed to support concrete floors for use in medical and other applications, where strict control of vibrations is required. 600 200 x 90 PFC 100 x 1.6 C 3000 Open side Internal wall 100 x 100 x 6 SHS 400 150 x 1.6 C 300 x 90 PFC Figure 5 Demonstration modular hospital ward building (with perspex wall to show construction) (Image courtesy of BW Industries) Figure 6 7500 max. Longitudinal edge beams of an open-sided (corner supported) module Open-sided modules comprise a primary steel framework with longitudinal edge beams supporting the floor joists. Edge beams are typically 300 to 450 mm deep, depending on the span, which typically is 5 to 8 m. Some systems use heavy cold-formed sections, and others use hot rolled steel sections, such as PFC. The combined depth of the edge beams, the ceiling and floor may be 600 to 800 mm. Design flexibility is provided by the open-sided modules. Their width is typically 3 to 3.6 m, and rooms of 6 to 12 m width can be created by combining modules. Figure 7 Installation of open sided modules for a hospital (Image courtesy of Yorkon) 4

Modules Supported by a Primary Structure Form of construction Modular units may be designed to be supported by a primary structure at a podium level. The supporting columns are positioned at a multiple of the width of the modules (normally 6 to 8 m). The beams are designed to support the combined loads of the modules above. Modules can be designed to be supported by steel or composite beams. Columns generally align with every 2 or 3 modules. The depth of the podium type structure is typically 800 to 1000 mm, and spans of 10 to 18 m can be created below the podium. The supporting steel structure provides open plan space at ground floor and below ground levels. An external steel structure, consisting of a façade structure that acts to stabilise the building, may also be used. Modules are placed internally within the braced steel exo skeleton, as shown in Figure 9. Stability of a tall modular building can also be provided by clustering the modules around a concrete core, as shown in Figure 10. The modules are designed to resist only vertical load. This form of construction is suitable for mixed retail, commercial and residential developments. Modules can be set back from the façade line. A mixed development with commercial space at ground floor is shown in Figure 8. Modular units may be supported by a hot-rolled steel or concrete podium structure. Buildings with podiums are typically mixed-use, with residential units above commercial areas or car parking. Figure 9 Installation of modules behind external steel framework at MoHo, Manchester (Image courtesy of Yorkon and Joule Consulting Engineers) Figure 10 Concrete core used to stabilise 16 storeys of modules (Image courtesy of Futureform and Ayrshire Framing) Figure 8 Podium structure used to support residential modular units (Image courtesy of The Design Buro and Ayrshire Framing) The use of a concrete core requires that the modules are tied into the core by cast-in plates and welded or bolted connectors to the corridors, which are designed as a horizontal wind girder. This may be in the form of cross bracing of the corridor floor panels, or for longer corridors, a separate lattice structure. 5

Other Types of Modules Stair modules Stairs may be designed as fully modular units. They generally comprise landings and half landings with two flights of stairs. The landings and half landings are supported by longitudinal walls, with additional angles or square hollow section members to provide local strengthening, if necessary. Stair modules may be used in buildings using fully modular construction up to four storeys in height. For their stability, stair modules rely on a base and a top, which leads to use of a false landing. The walls may require additional strengthening members at the half and full landing positions. The stairs can be fully or partially finished before delivery to site. SHS columns and bracing can be introduced in the walls to provide stability. A typical light steel modular stair system is shown in Figure 11. False landings or lateral sections are required to provide stability at the roof of the module. Non-load bearing modules Non-load bearing modules (or pods) are of similar form to structural modular units, but are not designed to resist loads, other than their own weight and the forces exerted during lifting. They are supported directly on a floor or by a separate structure, and are designed to be installed either as the construction proceeds or slid into place on the completed floor. Toilet/bathroom units, plant rooms, other serviced units. The structure of a non-load bearing module is lighter than in structural modular construction, but it must still be sufficiently rigid to resist the forces during lifting and installation. The walls and floor of these pods are relatively thin (typically less than 100 mm). An example of a bathroom pod used in a light steel structure is shown in Figure 12. Alternatively, the framework of the stair module may be made as a primary steel structure, in which case, the light steel walls act as infill. Figure 12 Toilet pod used with light steel framing in a hotel (Image courtesy of Metek UK) Compatibility of the floor depth in the module and in the floor elsewhere is achieved by one of four methods: Figure 11 Light steel modular stair system (Image courtesy of Ayrshire Framing) y Designing the depth of the floor of the module to be the same as the acoustic layer elsewhere. y Placing the module in a recess in the floor of the main structure. y Designing the module without a floor (possible in small modules by attaching fitments to the walls). y Designing the modules to be supported on the bottom flange of Slimflor beams. 6

Technical Solutions Stability and structural integrity Lateral stability can be provided by the modules themselves, or by an external structure. Robustness is provided by the ties between the modules; a minimum tying resistance equal to at least half the loaded weight of the module is recommended (minimum value of 30 kn). Module to-module connections are usually in the form of plates that are bolted together on site. Cladding Various forms of cladding may be used, such as: y Brickwork y Metallic fascia y Insulated render y Board materials. Lightweight cladding can be pre attached to the modules to eliminate the requirement for scaffolding. Acoustic performance The double layers of floor and ceiling, and separating walls, as shown in Figure 13, achieve excellent airborne and impact sound insulation. Airborne sound reductions of over 52 db (with low frequency correction factor), are achieved, which are up 5 to 10 db better than required by Part E of the Building Regulations. Impact sound transmissions are also low (< 30 db). Corner angle Sheathing boards External brickwork Insulation board Fire barrier Light steel studs Two layers of plasterboard Wall tie Mineral wool Thermal insulation Thermal insulation is characterised by the heat loss per unit area of façade (i.e. U value). Low U values of less than 0.2 W/m 2 C and excellent air tightness can be achieved. Services Services are usually pre-installed within the module and service attachments are made externally to the modules, usually in the corridor zone. The modules can be constructed with a recessed corner zone for vertical service routing, or a separate service zone may be constructed outside the module. Fire resistance Fire resistance is provided by multiple layers of fire resisting boards (Type F to BS EN 520). Two 15 mm thick fire resisting plasterboard layers internally plus 100 mm thick mineral wool can achieve a fire resistance of 90 minutes. Outer sheathing boards also assist in preventing passage of smoke into the modules. Regular fire cavity barriers in the form of mineral wool socks are provided horizontally and vertically, as in Figure 13. Balconies Balconies may be attached to modules in various ways: y Balconies supported by a self standing steel structure that is ground supported y Balconies attached between adjacent modules y Balconies attached to corner posts in the modules y Integrated balconies within open-sided modules. T & G chipboard Mineral wool insulating quilt Two layers of plasterboard Figure 13 View of floor and wall in modular construction showing fire protection and cavity barriers Light steel joists Figure 14 Raines Court, London showing modular construction with integral balconies (Image courtesy of Alford Hall Monaghan Morris and Yorkon) 7

Sources of Information Other technical information sheets The following technical information sheets provide further guidance about light steel construction. y ED010: Light Steel Solutions for All s y ED011: Light Steel Residential Buildings y ED012: Light Steel Framed Housing y ED013: Light Steel Infill Walls y ED015: Acoustic Performance of Light Steel Construction y ED016: Fire Safety of Light Steel Construction Manufacturers The following manufacturers are active in the light steel and modular construction sector and may be contacted for further information. Ayrshire Metal Products Ltd - www.ayrshire.co.uk BW Industries Ltd - www.bw-industries.co.uk Fusion Building Systems - www.fusionbuild.com Kingspan Profiles & Sections - www.kingspanprofiles.com Metek UK Ltd - www.metek.co.uk Bibliography The following publications may be referred to for more information on design in modular construction. Modular construction using light steel framing: Residential buildings (P302) Gorgolewski M T, Grubb P J and Lawson R M The Steel Construction Institute, 2001 Case studies on steel in residential buildings (P328) The Steel Construction Institute, 2003 Steel in multi storey residential buildings (P332) Lawson R M and Hicks S J The Steel Construction Institute, 2004 Acoustic detailing for steel construction (P372) Way A G J The Steel Construction Institute, 2008 Guidance on meeting robustness requirements on Approved Document A (P341) Way A G J The Steel Construction Institute, 2005 Insulated render systems used with light steel framing (P343) Wright C et al The Steel Construction Institute, 2006 Energy efficient housing using light steel framing (P367) Lawson R M and Francis K The Steel Construction Institute, 2007 Building Design using Modules (P348) Lawson R M The Steel Construction Institute, 2007 Figure 15 Light steel energy efficient housing constructed using modules (Image courtesy of Ayshire Metal and Futureform) The Steel Construction Institute Silwood Park, Ascot SL5 7QN T: 01344 636525 F: 01344 636370 E: publications@steel-sci.com www.steel-sci.com www.steelbiz.org 24 7 online technical information ED014 Light Steel Modular Construction December 2012, The Steel Construction Institute 8