WORKING IN THE ELECTRIFIED AREA



Similar documents
Handbook 16. Handbook 16. AC electrified lines. GE/RT8000/HB16 Rule Book

High Voltage (HV) Electricity System Safety Rules and Associated Safety Guidance

The Electrical Safety Regulation (pre and post 1 January 2014)

mit to Original Authorised Issue number Prepared Review date March 2014 copies up Electrified Interim Page 1 Manager National Standards

BMT Tax Depreciation Pty Ltd - Terms of Engagement

WHS CONTRACTOR MANAGEMENT PROCEDURE

WHS Contractor Management Procedure

Earthing Guidance Notes

Excavation & Trenching Procedure

Electrical safety rules

Corporate Standard. Contractor Management

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Contractor Training Courses & Pre-requisites. January 2016

Title: Plant and Equipment Management Procedure

Eskom Life Saving Rules Implementation of the Eskom Life Saving Rules

GroundRod AC Substation Earthing Tutorial

CHAPTER E12 - ENVIRONMENTAL IMPACT ASSESSMENT ACT

RISQS Audit Protocol: Network Rail On-Track Plant Operations Scheme (POS) module.

Queensland CORRECTIVE SERVICES AMENDMENT ACT 2003

ASBESTOS REMOVAL LICENCE ASBESTOS NOTIFICATIONS

Work in Substations - General

Employer resource assessment

Noosa Jazz Festival Terms and Conditions Food and Market Stalls

POLICY Contents. 1.0 Introduction Statement

Asbestos licensing and notification guide for applicants

PMA MODELS PTY LTD CONTRACTOR OFFER LETTER

Standard conditions of the Electricity Distribution Licence

Asbestos Management Policy (Version 3)

Credit Reporting Privacy Policy of Baybrick Pty Ltd

QUALIFICATION HANDBOOK

Asbestos removal and licensing

SAFETY AND SUSTAINABILITY POLICY

Health and Safety Policy and Procedures

Customer Installation Safety Plan. March 2015

Electrical Safety Policy

Department: Corporate Secretariat

ANGUS COUNCIL SUPPLEMENTARY CONDITIONS OF CONTRACT. SC 01 - Contract Performance Guarantee Insurance

CIRCULAR HEAD COUNCIL

1. GENERAL STATEMENT OF COMPANY HEALTH, SAFETY AND ENVIRONMENTAL POLICY

Digital Music Distribution Agreement between You (Licensor) and VIDYPS 79 (Licensee Owner of Blue2Digital)

X VIC X NSW/ACT X QLD X SA X NT X WA X TAS

Induction & Orientation of Educators, Students & Volunteers

Operational Control of the UKPN Low Voltage Distribution Network for EPN and LPN Regions

Life Saving Rules SAFETY BY CHOICE, NOT BY CHANCE

Procedures for Tenders and Contracts. October Huon Valley Council Procedures for Tenders and Contracts October 2014 Page 1 of 14

FORMAL LETTER OF APPOINTMENT FOR INDEPENDENT DIRECTORS

Procedure. Work Health and Safety Contractor Management. Document number: PRO Rev no. Description Process Owner Approved for issue

OH&S MANAGEMENT SYSTEM CHECKLIST - AS 4801:2001 (STATUS A = Acceptable; N = Not Acceptable; N/A = Not Applicable)

Other Review Dates: 15 July 2010, 20 October 2011

Miscellaneous Professional Indemnity Insurance

Trees, powerlines and your property

Pollution Incident Response Plan

U & D COAL LIMITED A.C.N BOARD CHARTER

Procedure: OHS CONTRACTOR MANAGEMENT

An employers guide to using the DBS Update Service

Procurement Transformation Division. Procurement guidance. Engaging and managing consultants. Includes definitions for consultants and contractors

Asset Protection Agreement Templates - Customer Explanatory Notes. Explanatory Notes on Asset Protection Agreement

Securing Jobs for Your Future - Skills for Victoria

Circuit Electrical Testing

CREDIT CARD POLICY AND PROCEDURES

WORKING IN ISOLATION PROCEDURE

Gladstone Ports Corporation Limited

GUIDE TO IMPLEMENTING A REGULATORY FOOD SAFETY AUDITOR SYSTEM

Standard Conditions for Recruitment Services

Queensland COAL MINING SAFETY AND HEALTH ACT 1999

Power of Attorney for Lead Member of Consortium

WORKING IN CONFINED SPACES GUIDELINES

Work Health and Safety (WHS) Policy

CAIRNS CRUISE LINER TERMINAL VENUE HIRE DEED

Assessment Centres and Psychometric Testing. Procedure

Terms and Conditions of Offer and Contract (Works & Services) Conditions of Offer

Steadfast Client Broker Agreement (Wholesale Broker) [Steadfast member] and GSA Insurance Brokers Pty Ltd

How To Protect Decd Information From Harm

Client Agreement for Investments & Insurances

COMMISSION REGULATION (EU)

SECTION 2 HAZARDOUS WORK. CLASSIC STANDARD 2.04 Working at Heights

Workers Compensation Return-to-Work-Program

Knowledge Transfer Partnerships: frequently asked questions

Management of Contractors and Suppliers Procedure

COUNCIL POLICY R180 RECORDS MANAGEMENT

ARTWORK COMMISSION AGREEMENT

Standard terms and conditions

FUNCTIONAL POLICY MANDATORY PROCUREMENT POLICY REQUIREMENTS FOR THE APPROVED CONTRACTOR INSURANCE PROGRAM INITIATIVE. Contracting Policy and Practice

Framework Terms and Conditions

SAFETY and HEALTH MANAGEMENT STANDARDS

MEDICAL-OBJECTS SOFTWARE LICENCE AGREEMENT

High Voltage. Hazards

Agreement For Trainee Position At [Company Name]

Transcription:

Network Safety Management System SPECIFICATION SAF/SPC/5178/ELE/NET WORKING IN THE ELECTRIFIED AREA Version 1.0 Effective Date: 12 October 2014 AURIZON COMMERCIAL-IN-CONFIDENCE

SAF/SPC/5178/ELE/NET Working in the Electrified Area Version 1.0 Authorisation This document is approved by: This document is authorised by: GM Network Assets VP Network Operations Copyright Aurizon Network Pty Ltd 2014 Confidential Information remains at all time the exclusive property of Aurizon Network Pty Ltd and shall at all times be kept secret and confidentiality maintained. Disclosure of Confidential Information without Aurizon Network Pty Ltd prior written consent is prohibited. Aurizon Network Pty Ltd asserts its rights in relation to Intellectual Property including the right to legal action for infringement. Revision History Version Issued Details Approved By: 1.0 08-09-2014 First publication VP Network Operations Network Safety Management System Page 2 of 53 Aurizon Network Pty Ltd 132 181 116

SAF/SPC/5178/ELE/NET Working in the Electrified Area Version 1.0 Modules MODULE 1 INSTRUCTIONS FOR NON-TRACTION STAFF... 4 MODULE 2 ISOLATION PROCESS... 12 MODULE 3 PLANNING INSTRUCTION... 20 MODULE 4 EARTHING... 29 MODULE 5 SUBSTATION ISOLATIONS... 37 Throughout this document: Terminology the terms must and shall indicate the statement is mandatory; and the term should indicates the statement is non-mandatory, i.e. advisory or recommended. Network Safety Management System Page 3 of 53 Aurizon Network Pty Ltd 132 181 116

MODULE 1 INSTRUCTIONS FOR NON- TRACTION STAFF Network Safety Management System Page 4 of 53 Aurizon Network Pty Ltd 132 181 116

Module 1 Contents 1 Purpose... 6 2 Scope... 6 3 Associated Documents... 6 4 Legislation... 6 5 Safety Principles... 6 6 Competencies... 6 7 Working within Electrical Exclusion Zones... 7 8 Safe Work Method Statements... 8 9 Qualified Persons... 9 9.1 Authorised Person... 9 9.2 Electric Control Operator... 9 9.3 Form B Holder... 9 9.4 Nominated Person... 9 9.5 Subsidiary Nominated Person... 9 10 Working during Isolations... 10 10.1 Form C Permit to Work NEAR... 10 10.2 Issuing Form C Permit to Work NEAR... 10 10.3 Receiving the Form C Permit to Work NEAR... 10 10.4 Transferring Form C Permit to Work NEAR... 11 10.5 Surrendering the Form C Permit to Work NEAR... 11 10.5.1 Bonding... 11 10.5.1.1 Bonding Requirements during Maintenance Shutdowns Isolations... 11 10.5.1.2 Bonding Requirements all other times... 11 Module 1 Figures Figure 1-1 Electrical Exclusion Zone... 7 Network Safety Management System Page 5 of 53 Aurizon Network Pty Ltd 132 181 116

1 Purpose The purpose of this Module is to outline the basic safety requirements for all staff when they are working in Aurizon Network s High Voltage (HV) electrified areas. 2 Scope This Module applies to staff and contractors working in the HV electrified areas. 3 Associated Documents Document Number Legislation Document Title Electrical Safety Act 2002 (Queensland) Document Library Queensland Government NET-ELE-RD-5177 Electric Traction Useful Terms & Definitions in-gauge NET-ELE-BI-1425 Electric Control Room Instructions in-gauge FORM-QRS-0009 Request to Work In Electrified Area in-gauge PRI/0014/COR Safety Risk Management Aurizon SMS QR 2007 of SAF/STD/0148/SWK/NET Network Communication Network SMS 4 Legislation The Electrical Safety Act 2002 (Queensland) and associated documents apply. 5 Safety Principles Workers shall always treat the HV electric traction infrastructure as LIVE and DANGEROUS. Overhead line equipment, power systems equipment, pantographs and roof-mounted electrical equipment on trains are extremely dangerous and can be fatal if you touch or go near to them, or if you allow anything to touch or go near to them. You shall treat these items as being LIVE at all times. No work shall commence within 3 metres of the overhead line equipment without the correct level of approval. Approvals depend on the type of work activity to be performed within the electrified areas as outlined within this Module. 6 Competencies The roles outlined in this Module shall be carried out by workers who have been trained and deemed competent to undertake the necessary roles and associated responsibilities. Network Safety Management System Page 6 of 53 Aurizon Network Pty Ltd 132 181 116

7 Working within Electrical Exclusion Zones The Electrical Safety Act 2002 (Queensland) specifies exclusion zones for work around LIVE electrical equipment. Aurizon Network s electrical exclusion zone is 3 metres from any LIVE electric traction infrastructure refer to Figure 1-1 below. Aurizon sets the electrical exclusion zone for Authorised Persons and Instructed Persons at 1.3 metres (An Instructed Person is a worker acting under the direct supervision of an Authorised Person). If there is a possibility that your work including the use of any plant, tools, or materials could come within the electrical exclusion zone you must have: a Safe Work Method Statement approved; and an Authorised Person appointed. You must not carry out any work above LIVE electric traction infrastructure unless a written Safe Work Method Statement has been approved by the owner of the electrical equipment. Figure 1-1 Electrical Exclusion Zone Network Safety Management System Page 7 of 53 Aurizon Network Pty Ltd 132 181 116

8 Safe Work Method Statements Working on and around the LIVE electrified track is classed as High Risk Construction Work and a Safe Work Method Statement must be in place. A Safe Work Method Statement shall be a written statement for the activity to be performed in the LIVE electrified area. It shall be prepared by or under the direction of the relevant manager for the activity and shall contain all of the following: a) The activity to be performed. b) The specific control measures that the relevant manager proposes to use to discharge their work health and safety duty for the activity. c) The way the relevant manager proposes to perform the activity, including how the control measures are to be used. d) How the effectiveness of the control measures shall be monitored and reviewed. An example of how the effectiveness of a control measure may be monitored: Before work starts each day the Authorised Person and operator shall review the activity and the Safe Work Method Statement and conduct a pre-start brief for all workers involved in the activity. The Safe Work Method Statement shall be signed off by the appropriate Line Manager who has the level of authority to sign off the risk as assessed when complying with PRI/0014/COR Safety Risk Management. The Safe Work Method Statement shall outline sufficient control measures to ensure the electrical safety of workers, plant and materials. A Safe Work Method Statement may be a generic work method statement prepared for workplaces where the activity is to be performed in the same way in the same or similar circumstances. Network Safety Management System Page 8 of 53 Aurizon Network Pty Ltd 132 181 116

9 Qualified Persons 9.1 Authorised Person In Aurizon Network, the Authorised Person is the authorised person as mentioned in the Electrical Safety Act 2002 (Queensland). Workers whose electrical safety is directly controlled by an Authorised Person are Instructed Persons. If work has the potential to come closer than 3 metres to LIVE overhead line equipment, an Authorised Person shall be in place at all times to supervise the electrical safety aspect of the work. Authorised Persons and Instructed Persons may work with a reduced Exclusion Zone of 1.3 metres. 9.2 Electric Control Operator The Electric Control Operator (ECO) is the worker who monitors, manages and controls the power supply to the overhead line equipment and is responsible for controlling all switching operations and isolations of HV electric traction infrastructure. Blackwater ECO controls the Blackwater System. Goonyella ECO controls the Goonyella System. 9.3 Form B Holder The Form B Holder is a qualified Nominated Person or a trainee Nominated Person under the direct supervision of a qualified Nominated Person who is responsible for: the isolation process in conjunction with the ECO; the Form B Authority for Testing, Earthing; issuing Permits to Work Near (Form C) and Access Permits. The Form B Holder is the only person who shall communicate the details of the Form B with the Electric Control Operator during the isolation and as such shall follow the Electric Control Operator s instructions. 9.4 Nominated Person A Nominated Person (NP) is a person who is qualified and approved by Aurizon Network to switch, test, apply earths and issue permits. 9.5 Subsidiary Nominated Person A Subsidiary Nominated Person (SNP) is a qualified Nominated Person, acting under the instructions of the Form B Holder or the Access Permit Recipient. Network Safety Management System Page 9 of 53 Aurizon Network Pty Ltd 132 181 116

10 Working during Isolations All isolations shall be planned and approved in advance. To work during a Planned Isolation a Request to Work in Electrified Area Form, FORM-QRS-0009 (available via in-gauge) shall be completed and issued to the appropriate Isolation Planning Coordinator. Electrical safety advice can be sought from the local Traction Power Engineer or the local Isolation Planner. 10.1 Form C Permit to Work NEAR The Isolation Planning Coordinator shall determine which workgroups are to be issued with a Form C Permit to Work NEAR. An Authorised Person shall be appointed by line management. The Authorised Person is responsible for: receiving and surrendering the Form C Permit to Work NEAR; the electrical safety of the workers; giving a pre-start safety brief to the workers. Permits shall be issued to Authorised Persons at pre-determined times and locations. Permits shall be cancelled at the specified times and locations. If contact is made with the electric traction infrastructure then the Authorised Person shall contact the Form B Holder or Electric Control Operator immediately. 10.2 Issuing Form C Permit to Work NEAR The Form B Holder or Subsidiary Nominated Person issuing a Form C Permit to Work NEAR shall: check the Authorised Person s credentials. communicate worksite electrical safety information to the Authorised Person. This shall include, but not be limited to; isolation duration and times, work-site limits, any nearby LIVE equipment and hazards. inform the Authorised Person of the rules associated with the Form C Permit to Work NEAR as outlined on the cover of the Form C books. communicate the Authorised Person transfer process. ensure the Authorised Person reads out, understands and signs the Authorised Person declaration. 10.3 Receiving the Form C Permit to Work NEAR Only an Authorised Person can receive permits from a Form B Holder or Subsidiary Nominated Person. Authorised Persons receiving Form C Permits to Work NEAR shall: show credentials to the Form B Holder / Subsidiary Nominated Person; follow the Form B Holder / Subsidiary Nominated Person s instructions; sign the Authorised Person Declaration in front of the Form B Holder / Subsidiary Nominated Person; keep the permit in your possession and not leave it unattended on site; remain on-site whenever work is being carried out; transfer the permit only to another Authorised Person; ensure any LIVE infrastructure adjacent to the worksite is communicated to the work group. Network Safety Management System Page 10 of 53 Aurizon Network Pty Ltd 132 181 116

Permits shall not be copied or duplicated. A Form C Permit to Work NEAR does not absolve the Authorised Person from ensuring that adequate track protection has been provided. Track protection must ensure that trains cannot inadvertently enter the Worksite. 10.4 Transferring Form C Permit to Work NEAR An Authorised Person may transfer the permit as required, however an Authorised Person can only be relieved by another Authorised Person. The transfer shall be documented on the Form C Permit to Work NEAR and the relief Authorised Person shall inform the Form B Holder or Electric Control Operator immediately. 10.5 Surrendering the Form C Permit to Work NEAR The Authorised Person shall ensure all workers and materials are clear of the track and treat the HV electric traction infrastructure as LIVE and DANGEROUS. The Authorised Person shall complete Part 3 of the Form C Permit to Work NEAR. The Form B Holder / Subsidiary Nominated Person shall: confirm that the Authorised Person surrendering the Form C Permit to Work NEAR is the duly appointed Authorised Person; confirm with the Authorised Person that no contact has been made with electric traction infrastructure; ensure the Authorised Person reads out and understands the statement in the Clearance section of the permit and has advised their workers that the Form C Permit to Work NEAR and all associated access has been cancelled; confirm the Authorised Person has signed the Clearance Declaration; instruct the Authorised Person that the overhead line equipment shall now be regarded as LIVE and DANGEROUS. 10.5.1 Bonding 10.5.1.1 Bonding Requirements during Maintenance Shutdowns Isolations During Maintenance Shutdown (MS) Isolations only: where the rail is required to be cut or bonds are to be removed and or replaced within the limits of the isolation; then temporary bonds are not required to be installed around the repair site. All bonds shall be re-installed before the isolation can be cancelled. If the repair work cannot be completed within the timeframes of the isolation, temporary bonding shall be installed to ensure electrical safety. 10.5.1.2 Bonding Requirements all other times Temporary bonds shall be applied around repair work where the rail is to be cut or removed to ensure electrical safety during all isolations not classed as MS Isolations. If bonding requirements are unclear, advice can be sought from the local Traction Engineering Staff. Network Safety Management System Page 11 of 53 Aurizon Network Pty Ltd 132 181 116