MIT510/2, MIT520/2 and MIT1020/2

Similar documents
5000V Graphical Megohmmeter Model 5070

Insulation resistance testing. A complete solution for every person.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

DET3 Contractor Series 3-Terminal Earth/Ground Resistance Testers

Multi-Function Ground

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

DC Electronic Loads 8500 series

Handheld portable appliance testers

DET3 and 4 Contractor Series Earth/Ground Resistance Testers

User's Guide. True RMS Industrial Multimeter

User Guide. Model Insulation Tester / Megohmmeter

DET3 Contractor Series

Why Buy HVI VLF Products?

T Substation Maintenance and Commissioning Test Equipment

Digital Transformer Ratiometer DTR Model 8500

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

High Voltage Test Equipment. Product Catalogue

Dialight Control and Monitoring System for Vigilant LED Based Obstruction System for High Intensity Installations. FAA Type B FAA Type C FAA Type F

80 Series - Modular timers 16 A. Features

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Integrating Sound Level Meter and Datalogger

DS 600. A contact free flux gate based current measurement sensor 600A rms

38 Series - Relay interface modules A

Multi-Range Programmable DC Power Supplies 9115 Series

World Leader in HV Testing Technology

USB-500/600 Series Low-Cost Data Loggers and Accessories

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

MEGGER Insulation & Low Resistance Tester

A Guide To Diagnostic Insulation Testing Above 1 kv TOLL FREE CUSTOMER SERVICE NUMBER.

Ron 3025 Crane Scale with 1"/25mm Display

Thyristor-controlled power supplies and battery chargers

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

38 Series - Relay interface modules A

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Digital MULTIFUNCTION & INSULATION CONTINUITY-VOLTAGE TESTER

Model UT201/202: OPERATING MANUAL. Table of Contents

Understanding Insulation Resistance Testing

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Current Monitoring Kit

High Voltage Power Supplies

AC-Synchronous Generator

Instruction Manual. T3111 T3111L T3111P T3111Ex

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

49 Series - Relay interface modules A. Features

PAT120, PAT150 and PAT150R Handheld portable appliance testers

Voltage Regulator SPAU 341 C. Product Guide

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

80 Series - Modular timers 16 A. Features

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

USB-500 Series Low-Cost Data Loggers and Accessories

48 SERIES Relay interface modules 10 A

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

USB-500 Series Stand-Alone, Low-Cost Data Loggers

TORKEL 820 Battery Load Unit

Multifunction Digital Timer

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

AMB V Insulation Resistance Tester. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

Low and High Voltage Power Supplies

Fluke 1650B Series Multifunction Installation Testers

AutoRanging Digital MultiMeter

SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

Digital Clamp-on DMMs with uncompromising performance


T0118 T2118 T3118. Instruction Manual

USB-500/600 Series Low-Cost Data Loggers and Accessories

Fluke 3000 FC Series Test Tools Technical Data

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Bulletin 150 SMC Flex Smart Motor Controller Specifications

AVO410. Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter

A Guide To Diagnostic Insulation Testing Above 1 kv

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

AMB V Insulation Resistance Tester. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

User's Guide. Integrating Sound Level Datalogger. Model Introduction

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Advanced Systems Tester 900AST

Insulation Resistance Testing of Low Voltage Cables in the Field

Agilent 87421A/87422A Power Supply

Permissible ambient temperature Operation Storage, transport

Insulation resistance testing

Current Monitoring Kit QUICK START GUIDE

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

Power Capacitor Units for improved power quality

Table of Contents. Page

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Manual Ranging MultiMeter

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

AC3200 INTELLIGENT BROADBAND AMPLIFIER

Physical Specifications (Custom design available.)

Transcription:

99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com MIT510/2, MIT520/2 and MIT1020/2 Line supply or battery operated Digital/analog backlit display Measurement range to 15 TΩ (MIT510/2 and MIT520/2) and 35 TΩ (MIT1020/2) CAT IV 600 V safety rating Automatic dielectric absorption ratio, polarization index, step voltage, and dielectric discharge tests (MIT520/2 and MIT1020/2) RS232 or USB download of results (MIT520/2 and MIT1020/2) Ingress protection to IP65 3 ma short circuit current DESCRIPTION The new MIT510/2 and 520/2, 5-kV and MIT1020/2, 10-kV insulation resistance testers are all designed specifically to assist the user with the testing and maintenance of high voltage equipment. The instruments are designed in a landscape style which is more familiar and user friendly. The MIT510/2 and MIT520/2 measures to 15 TΩ, replacing the ambiguous infinity reading with an actual number that can be used for predictive/preventive trending on the highest quality insulation. Both units are supplied with test leads with medium insulated clips. The MIT510/2 has the facility to set the test voltage in steps from 250 V to 5000 V and the MIT520/2 has the ability to set the test voltage from 50 V to the maximum output voltage. The MIT1020/2 offers a measurement range to 35 TΩ in order to provide trending values for the best of insulating materials used on the higher capitalized equipment. The model features an expanded test voltage range from 50 V to 10 kv, in 10 V increments to 1 kv and 25 V increments above. The MIT1020/2 is supplied with two sets of test leads, one with medium insulated clips and the other with large insulated clips. All three instruments have a large, easy-to-read backlit LCD making them equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time is displayed constantly, removing the need for separate timers. The MIT520/2 and MIT1020/2 allow up to 3 timed measurement positions to be set, which simplifies DAR testing. A built-in integral timer starts automatically at the beginning of a test, and displays in minutes and seconds. At the end of any test, capacitive loads are automatically discharged and the decaying voltage displayed. The timer enables the performance of an automatic IR test with the MIT510/2, while the MIT520/2 and MIT1020/2 add the capability of preprogrammed DAR, PI, SV and DD. The MIT520/2 and MIT1020/2 include a selectable breakdown or burn mode and an alarm mode, which allows the operator to preset a specific resistance level. The unit will beep until the limit is exceeded. The controls of the instruments are clear and unambiguous, and a quick start guide is included in the lid, eliminating the need to carry manuals to site locations. Redundant safety features make the instruments fully amenable to safe operation in the more demanding high voltage environment. The CAT IV 600 V safety rating means that the instruments are protected for use on outside applications and are protected against impulses to 8 kv. Instrument design is in conformance with EN61010 for arc-flash protection. If the instrument is accidentally connected to a live test item, external voltage will be automatically displayed and testing inhibited above 50 V (80 V on MIT1020/2). At the conclusion of a test, dangerous static voltage on the test item is automatically discharged and monitored on the display. All three models are fitted with a guard terminal to enhance accuracy. The guard test lead is included as standard with each instrument.

APPLICATIONS All three models are designed for testing the insulation of high-voltage electric equipment. Their wide voltage range also allows applications for low-voltage equipment. Generators, motors, transformers, cables and switchgear all require effective maintenance. The test techniques on the instruments provide valuable diagnostic information. All three instruments test the insulation resistance of: High-voltage power cables and high-voltage buses Large motor/generator windings Line and substation transformers The MIT520/2 and MIT1020/2 also perform spot tests, step-voltage tests, dielectric discharge tests and dielectric absorption tests for the following applications: Acceptance testing at installation to check conformance to specifications. Routine preventive/predictive maintenance testing after installation. Quality assurance testing as part of the manufacturing process. Diagnostic testing to isolate faulty components for repair. With its higher voltage testing capability, the MIT1020/2 is the perfect every day work tool for manufacturers, users and maintainers of rotating machinery. Designed in accordance with the requirements of IEEE43:2000 the MIT1020/2 is ideal for measuring the insulation resistance of armature and field windings in rotating machines rated 1hp (750 W) or greater. The standard applies to synchronous, induction and dc machines as well as synchronous condensers. FEATURES AND BENEFITS CAT IV 600 V safety rating allows for safe use in the widest range of applications. Improved operating flexility provides the user with the choice of using these instruments via line or battery operation. Line operation also affords enhanced charging capabilities for high-capacitance test samples. High measurement range enables installation testing and long-term trending of higher value apparatus. 3 ma short circuit current allows for faster charging and testing of large capacitive and inductive loads. Results storage and downloading enables state-of-the-art record keeping free of transposition errors. Five industry-standard tests can be performed automatically, freeing operator from time-consuming manual operations. Backlit display enables ease of testing in poorly lit areas. Rugged, lightweight polypropylene case and IP65 rating make all of the instruments adaptable for all field conditions. A variety of measurements including applied test voltage, leakage current and capacitance, affords enhanced capabilities to diagnose insulation condition and problems. Redundant safety features includes automatic discharge of test item, test inhibition in presence of external voltage, and design to EN61010. The MIT1020/2 in use at an industrial complex substation Delta wye transformer being testing with a MIT520/2

The MIT1020/2 incorporates the ability to apply test voltage up to 10 kv, making it fully conformable to the requirements of IEEE 43:2000. Industry best guard terminal performance to insure highest accuracy of measured values. For greater ease of use and downloading, an RS232 or USB interface is available (MIT520/2 and MIT1020/2 only). Alarm limit mode (MIT520/2 and MIT1020/2 only) allows for faster testing and less ambiguous result interpretation. SPECIFICATIONS Test Voltage MIT510/2: 250 V, 500 V, 1000 V, 2500 V, 5000 V MIT520/2: 50 V to 1 kv in 10 V steps, 1 kv to 5 kv in 25 V steps MIT1020/2: 50 V to 1 kv in 10 V steps, 1 kv to 10 kv in 25 V steps Insulation Resistance Range Digital display: MIT510/2 and MIT520/2: 10 kω to 15 TΩ MIT1020/2: 10 kω to 35 TΩ Analog display: MIT510/2, MIT520/2 and MIT1020/2: 100 kω to 1 TΩ Accuracy (23º C) ±5% to 1 TΩ ±20% to 10 TΩ (MIT520/2) ±20% to 20 TΩ (MIT1020/2) Voltage Output Accuracy (0ºC to 30ºC) 0 to +4% ±1 V of nominal test voltage at 100 MΩ load ±25 V for test voltages less than 500 V kv 6 5 4 3 2 1 0 5kV Voltage Characteristic 0 1 2 3 4 5 6 7 8 9 10 M Ohms Test Voltage Output Characteristics Over Insulation Resistance Range 5kV 2.5kV 1kV 500V 250V Short Circuit/Charge Current 3 ma Current Measurement Range: ±0.01 na to ±5 ma Accuracy (23ºC): ±5% ±0.2 na at all voltages Capacitance Measurement Range: 10 nf to 50 µf (for voltages > 500 V) Accuracy (23ºC): ±5% ±5 nf Capacitor Charge Time: 5 seconds per µf at 3 ma Discharge Time: 5 seconds per µf to discharge from: MIT510/2 and MIT520/2: 5000 V to 50 V MIT1020/2: 10,000 to 50 V Display Analog/digital 3 digits Timer Range Count up to 99 minutes and 59 seconds from start of test Memory Capacity (MIT520/2 and MIT1020/2) 32 kb Industry-Standard Tests MIT510/2: Auto IR MIT520/2: Auto IR, PI, DAR, SV, and DD MIT1020/2: Auto IR, PI, DAR, SV, and DD Interference Rejection 2 ma rms at 200 V and above Guard Terminal 2% error guarding 500 kω leakage with 100 mω load Voltage Input Range 95 to 240 V, ±10% rms 50/60 Hz and dc Battery Life 6 hours continuous testing at 5 kv 4 hours continuous testing at 10 kv Safety Meets the requirements of EN61010-1: 2001 CAT IV 600 V EMC Meets the requirements of EN61326-1:1998 for use in heavy industrial areas Ingress Protection IP65 (lid closed) Temperature Range Operating: -4ºF to 122ºF (-20ºC to +50ºC) Storage: -13ºF to +149ºF (-25ºC to +65ºC) Humidity Range 90% RH @ 104ºF (40ºC) Dimensions 12 in. x 7.6 in. x 14.2 in. (305 mm x 194 mm x 360 mm) Weight 15 lb. (6.75 kg)

These unique features improve insulation testing efficiency and effectiveness Extra data storage and download capability Run more tests and save more test data. Download results using either an RS232 or USB style connection (MIT520/2 and MIT1020/2 only). Line or battery operation The operating flexibility you need when site conditions are unknown or long term testing is required. Multiple built-in safety features Designed to meet the most stringent operator safety requirements, including EN61010. Includes live voltage warning, safety lockout over 50 V on 5-kV testers and 80 V on 10-kV testers, and automatic energy discharge. Improved enclosure It s virtually indestructible, yet ergonomic and lightweight. It features an oversized rubber handle and removable lid for effective use in tight places. A lid mounted lead storage bag is also included. Easier operation Use a Quick Start guide conveniently located in the lid, always there for easy reference.

Product comparison guide. A look at each instrument s features. MIT510/2 MIT520/2 MIT1020/2 Display Analog/Digital Power Supply Mains power Rechargeable 10.0 kv 5.0 kv 2.5 kv Test Voltage 1.0 kv 500 V 250 V 10 V steps 50 V to 1 kv, 25 V steps 1 kv to max test voltage Max reading 15 TΩ 15 TΩ 35 TΩ Min reading 10 kω 10 kω 10 kω Measurements Voltage Capacitance and time constant Leakage current Auto IR Polarization index Test Types Step voltage Dielectric discharge Dielectric absorption ratio Timer control Timer display 3mA test currents Other Features USB output RS232 output Free calibration certificate IP65 rating Alarm limit mode Guard terminal performance 2% error guarding 500 kω leakage with a 100 MΩ load What is the IEEE Standard 43-2000? In March 2000, the IEEE-SA Standards Board approved a revision of IEEE Std 43-1974 by the Electric Machinery Committee of the IEEE Power Engineering Society. This revision is IEEE Std 43-2000, the IEEE Recommended Practice for Testing Insulation Resistance of Rotating Machinery. Following is a brief summary of the highlights of IEEE Standard 43-2000: Test voltages up to 10 kv are recommended for windings rated greater than 12 kv. Both the insulation resistance and the polarization index test are recommended. Test results should be compared to historical values to identify changes. In lieu of historical records, minimum acceptable values (based on the type of equipment) for both tests are indicated. Depending on the machine rating, the readings for one or both tests should exceed the minimum acceptable values. If the readings are below the minimum acceptable values, the winding is not recommended for an overvoltage test or for operation.

MIT520/2/MIT1020/2 DISPLAY EXAMPLE 1 15 14 13 12 11 2 3 10 4 4 5 9 6 7 8 1. Voltage at terminals Displays amount of voltage present at the terminal. 2. Battery level Indicates the level of battery operation available. 3. Breakdown indicator Indicates that breakdown mode is in operation 4. High-voltage indicator Indicates the presence of high voltage during operation. 5. Digital display Displays the reading during a test. 6. Dielectric absorption ratio (DAR) 7. Polarization index (PI) 8. Time constant 6 through 8 Displays the ratio value or the resistance measured at the indicated time. 9. Capacitance display Indicates the capacitance of the test sample. 10. Analog display Unique, patented analog display shows resistance with real-time pointer movement. 11. Timer Displays the elapsed time of test. Displayed constantly, eliminating the need for a separate timer. 12. Data recording Indicates if data is being recorded during the test. 13. Alarm Indicates that alarm has been set. 14. Burn indicator Indicates that burn mode is in operation. 15. Test modes Shows which pre-programmed test is being run. ORDERING INFORMATION Item [Qty] Cat. No. MIT510/2 5-kV Insulation Resistance Tester 1000-372 MIT520/2 5-kV Insulation Resistance Tester 1000-376 MIT1020/2 10-kV Insulation Resistance Tester 1000-380 Included Accessories 10 ft (3 m) lead set, medium insulated clips [3] 6220-820 10 ft (3 m) lead set, large insulated clips [3] for MIT1020/2 only 6220-811 RS232 cable (MIT520/2 and MIT1020/2) EV25955-025 USB cable (MIT520/2 and MIT1020/2) 25970-041 Item Cat. No. Line cord 17032 Pouch 6320-244 MIT510/2 User guide, CD version 6172-929 MIT520/2/MIT1020/2 User guide, CD version 6172-960 Optional Accessories 33 ft (10 m) lead set, medium insulated clips [3] 1000-441 50 ft (15 m) lead set, medium insulated clips [3] 1000-442 33 ft (10 m) lead set, large insulated clips [3] 1000-443 50 ft (15 m) lead set, large insulated clips [3] 1000-432 Visit us at www.testequipmentdepot.com