Daniel Danalyzer Model 700 Gas Chromatograph

Similar documents
Danalyzer Model 700 Gas Chromatograph

Emerson Gas Chromatograph Solutions For Natural Gas Transmission Applications. Superior Performance, Repeatability, and Reliability

Rosemount Analytical 1500XA Process Gas Chromatograph

Natural Gas Processing Solutions Using the 700XA Gas Chromatograph

Chromatograph Maintenance and Troubleshooting Class # 5050

Process Instrumentation

Natural gas chromatograph LNG gas quality testing

Process Gas Chromatograph

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Fundamentals of Gas Chromatography

Micro Motion 3098 Gas Specific Gravity Meter

CHROMOCTANE O N LINE ANALYZER

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

Microcor Wireless Transmitter (MWT)

S-series SQ Controller

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja

The DL8000 Preset Controller. The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Emerson Smart Firewall

Multi-Range Programmable DC Power Supplies 9115 Series

On-line Dissolved Gas Analysis

S-series Mass Connection Solutions

IFC 070 Technical Datasheet

M-series Virtual I/O Module 2

Bristol ControlWave Redundant Control

M-series FOUNDATION Fieldbus I/O

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

3500/93 System Display

TrueAlarm Fire Alarm Systems

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Analytical Service Certification Program

COMBIMASS. Technical Data COMBIMASS eco-bio +

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Section TELEPHONE AUTOMATIC DIALER SYSTEM

ROC800L Liquid Application Software

Chassis, Power Supply, and Element Management

M-series MD Plus Controller

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Daniel Venturi Tubes and Flow Nozzles Brochure

How To Use Safety System Software (S3)

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

1500XA Gas Chromatograph

Model 500 Gas Chromatograph Hardware Reference Manual

BTU ANALYSIS USING A GAS CHROMATOGRAPH

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Temperature & Humidity SMS Alert Controller

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Multi-Range Programmable DC Power Supplies 9115 Series

Uninterruptible Power Supply

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Centro-Matic Automatic Lubrication Systems System Controls

AXIS 262+ Network Video Recorder

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Metering for today s systems

Regards from the Team at Rheology Solutions.

Rackmount Intelligent Pressure Scanners

NETWORK ENABLED EQUIPMENT MONITOR

KNC Model 3666 Automatic Pressure Calibration System

AMS ValveLink SNAP-ON Application

O C M III. Open Channel Flow Monitor

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

PIEZOMETER AIRFLOW MEASURING RING

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

1.44 kw Programmable DC Power Supplies XLN Series

Lockout Specification BW Clip Maintenance-free single gas detector

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

The L&J Engineering Model MCG 1500SFI Servo Gauge

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

23 The Thermal Conductivity Detector

User's Guide. Integrating Sound Level Datalogger. Model Introduction

DeltaV Remote Client. DeltaV Remote Client. Introduction. DeltaV Product Data Sheet. Remote engineering and operator consoles

Online Infrared Flue Gas Analyzer Gasboard 3000

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

USB-500/600 Series Low-Cost Data Loggers and Accessories

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Tank Gauging & Inventory Management Solutions

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

Repeaters and Mimics Data Sheet

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

A-307. Mobile Data Terminal. Android OS Platform Datasheet

3500/22M Transient Data Interface

FREQUENCY RESPONSE ANALYZERS

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

EnerVista TM Viewpoint Monitoring v7.10

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

Phase Modular Finally the benefits of Modular ups are for all

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Transcription:

Product Data Sheet Model 700 Daniel Danalyzer Model 700 Gas Chromatograph Danalyzer Model 700 Gas Chromatographs offer the broadest range of analysis options available today in a fieldmount gas chromatograph (GC). Whether it is heating value measurement, trace contaminant monitoring, pipeline integrity, or product quality/process control, the Danalyzer Model 700 is flexible enough to meet your analysis needs. Based on the same proven technology and software as the Danalyzer Model 500 series, the Danalyzer Model 700 design offers superior reliability and precision, lower installation and operating costs, greater application flexibility, and unmatched measurement performance. Features and Benefits One package for fiscal metering or gas quality Custody transfer analysis from C 6 + to C 9 + Contaminant monitoring - trace H 2 S, CO 2, oxygen, etc. Combine measurements and reduce analysis cost Oxygen (0-2%) Trace H 2 S (0-50 ppm) CO 2 (as fast as 90 seconds) Helium/Hydrogen (0-10%) Hydrocarbon Dew Point (±2 C) Reduced installation costs 24 VDC power standard Integrated controller electronics Pipe-mount, wall-mount, or floor mount Unmatched measurement performance Highest stated precision ±0.25 BTU/1000 for broad ambient temperature C 6 + analysis in -18 to 54 C (0-130 F) environmental conditions Wide dynamic range from percent to trace level components Reliable performance over broad ambient temperatures -30 C to 60 C (-20-140 F) Easy to use Compatible with Danalyzer Model 500 Gas Chromatographs MON2000 software setup and diagnostics Identical setup and operation for all models no additional training Lower operation and maintenance costs No shelter or instrument air required Low helium and power consumption Longest gas chromatograph valve and column warranties available Visit us online at www.daniel.com

APPLICATIONS Standard Natural Gas Applications We have made our most popular energy and gas quality applications standard. Applications may vary by components of interest, analysis time, reduced hardware (economics), or improved precision. Choose the one that is right for you, or we will create one that is customized for your specific application. Energy Measurement (to C6+ and C9+) The Danalyzer Model 700 offers applications for energy measurement from C6+ hydrocarbon ranges to C9+ hydrocarbon ranges. Calculations based on GPA 2145 or ISO 6976 standards can be provided. Standard Measurement Ranges Methane 65 to 100-mole % Ethane 0 to 20-mole % Propane 0 to 10-mole % N-Butane 0 to 5-mole% Iso-Butane 0 to 5-mole % N-Pentane 0 to 1 mole % Iso-Pentane 0 to 1 mole% Neo-Pentane 0 to 1 mole% Hexane+ 0 to 0.7-mole% Nitrogen 0 to 20 mole % Carbon Dioxide 0 to 20 mole% Hexanes 0 to 1 mole% Heptanes 0 to 1 mole% Octanes 0 to 0.5 Mole% Nonane+ 0 to 0.5 mole% C 6 + C 9 + Hydrocarbon Dew Point Monitoring Accurate and reliable hydrocarbon dew point determination can now be made as an option to any C 9 + extended analysis application. The DewCalc Hydrocarbon Dew Point software is completely integral to the gas chromatograph and provides dew point temperatures and cricondentherm for up to four userentered pressures. Alternately, real-time dew point results can be provided by using analog or Modbus inputs from another device. DewCalc software is loaded with features, including: Choice of two equations of state, Peng-Robinson or Soave-Redlich-Kwong Library of 93 hydrocarbon compounds for detailed breakdown of C9+ fraction DewCalc report with analysis results and factors used Custom Applications If our standard applications do not fit your needs, the Danalyzer Model 700 can be customized to meet your measurement requirements. Simply submit a completed application data sheet found at the end of this data sheet with your request, or ask our Application Engineers for assistance. Gas Quality Analysis Natural gas contaminants reduce pipeline integrity over time. Most contaminants can be easily measured in the Model 700 for online quality assurance. Contaminant monitoring can be combined with energy measurements for complete custody transfer analysis. To the extent possible, these combined applications utilize independent gas chromatograph valves, detectors, and columns, for each primary measurement. This technique offers greater reliability, increased speed, and easier troubleshooting. This application approach also makes field upgrades and re-applications in the Danalyzer Model 700 easy by minimizing internal piping changes. Page 2

Standard Danalyzer Applications and Repeatability Application Code Application Name Components Measured Analysis Time % Repeatability @ Controlled temperature 604 Standard BTU/CV C1 to C6+, CO2, N2 4 min ±0.0125 ±0.025 6GT Gas Turbine BTU/CV/ C1 to C6+, CO2, N2 2 min ±0.05 ±0.1 Density TS2 Gas Quality (H2S) Trace H2S (3-30 ppm) 90 sec ±2 ppm ±3 ppm LF8 Landfill Gas BTU/CV C1, N2, CO2, O2 8 min ±0.1 ±0.2 LF3 Landfill Gas (mole-sieve) C1, N2, CO2, O2 3 min ±0.1 ±0.2 % Repeatability Over 0-130 F 6PS Std C6+ with % H2S C1 to C6+, CO2, N2, H2S 10 min ±0.05 ±0.1 (%) 6PO Std C6+ with % Oxygen C1 to C6+, CO2, N2, O2 10 min ±0.05 ±0.1 6HH Std C6+ with Helium/ Hydrogen C1 to C6+, CO2, N2, He/ H2 5 min ±0.05 ±0.1 6TS C6+ with ppm H2S C1 to C6+, CO2, N2, H2S 7 min ±0.0125/±2 ppm ±0.015/±3 ppm (ppm) 905 Std C9+ C1 to C9+, CO2, N2 5 min ±0.025 ±0.05 HC9 Std C9+ and Hydrocarbon C1 to C9+, CO2, N2 5 min ±0.025 ±0.05 Dewpoint 712 Standard C7+ BTU/CV C1 to C7+, CO2, N2 10-12 min ±0.025 ±0.05 SUPERIOR PERFORMANCE The Danalyzer Difference Modular Analytical Oven An element that is key to the Danalyzer Model 700 Gas Chromatograph s application flexibility is the modular analytical oven. Using field-proven Danalyzer valves, columns, and detectors, the analytical oven has been redesigned to make it modular and scalable. Six- or ten-port valves and detectors mount to a triangular kiosk block which facilitates valve heating and pneumatic actuation. Three temperature control zones and up to three valves and two detectors operating independently provide extreme application flexibility and range. All components in the oven are completely accessible and serviceable in the field. Gas Chromatograph Valves At the heart of the Danalyzer s superior reliability are the six- and ten-port diaphragm/piston gas chromatograph valves. These pneumatic valves are guaranteed for the life of the gas chromatograph and specified to operate over 5 million times between service. By minimizing internal movement (1/1,000 inch) of the pistons, which never come in contact with sample, abrasive mechanical wear is virtually eliminated. This unique double-diaphragm design removes the need for all springs, o-rings, or lubrication. Valve service is performed by replacing a cost-effective diaphragm set, normally completed in less than 10 minutes. Detectors The thermal conductivity detector (TCD) is the detector of choice for most applications due to its universal response to all compounds. The TCD found in the Danalyzer Model 700 Gas Chromatograph is able to go well beyond the normal measuring ranges seen in other designs by being able to do many applications Page 3

with low parts-per-million measurement requirements. This greatly simplifies the gas chromatograph design when a simple and rugged TCD can be used. The flame ionization detector (FID) for trace hydrocarbon measurements and the flame photometric detector (FPD) module for trace sulfur measurements are also available. Micro-packed Columns Danalyzer micro-packed columns offer a superior combination of features found in both capillary and conventional packed columns speed, sharp peak resolution, and low carrier gas consumption. In addition, this unique design provides for greatly extended column life and the longest warranty available on the market (five years on the standard C 6 + natural gas set). Stream Switching Module The Danalyzer Gas Chromatograph offers an internal sample stream switching module. Available in four- or eight-stream versions, this module utilizes the same helium-rated 24-volt solenoids used in the analytical oven. It is temperature-controlled for operation above the sample dewpoint. For applications with widely varying stream composition, double block and bleed configuration is optionally available. Local Indication and Operation Panel Analyzer health and valve status can be viewed through the glass cover of the lower enclosure. The panel displays green (OK), yellow (warning), and red (failure) LEDs, along with LEDs for all gas chromatograph valve actuations, power, and CPU health. Each valve can be actuated manually for simplified troubleshooting and fast system purging after maintenance. Touch Key Local Operator Interface (Optional) The Model 700 local operator interface (LOI) allows for maintenance and operation of a Model 700 without a laptop or PC. The LOI is a state-of-the-art high resolution color display that is touch key infrared activated and supports all core GC operations. Features of the LOI include: - Color LCD with QVGA (320 x 240 pixels) resolution - ASCII text and graphics modes - Auto-backlighting (adjustable) - 8 infrared-activated touch keys and screen saver - Eliminates external magnetic pen requirement - Maintains the Model 700 hazardous area classifications - Operates in the same ambient temperatures as the base Model 700 - Complete GC status, control and diagnostics, including full chromatogram display CONTROLLER ELECTRONICS AND COMMUNICATIONS Modular Electronics The controller electronics, option cards, and field termination boards are packaged conveniently in the lower enclosure of the Danalyzer Model 700. Separate power and output connections are made through this enclosure. Compatible Electronics and Software The Danalyzer Model 700 uses the same CPU board as the Danalyzer Model 500, thus making features, options, and operation nearly identical. No new training is required. Model 700 shown with optional touch-key LCD LOI Page 4

Data archiving and reports The Danalyzer Model 700, with expandable solid-state memory, virtually eliminates the need for external data storage. Every analysis is time/date stamped and archived, for retrieval via the MON2000 software. Pre-configured reports can be displayed, printed, and/ or stored internally. Results can be trended directly or exported easily in ASCII format. Security - three levels of password protected security configurable to read/write or read only for third party access Audit logs - data and event logging fully conforms to API report 21.1 for metering audit purposes and backup to primary systems (flow computer, SCADA, DCS) Event logs - a continuous record of all operator changes, with time, date, and operator name recorded Alarm logs - a continuous record of all historical alarms, time/date stamped with alarm state and description Maintenance log - a scratch pad for keeping track of maintenance or testing performed on the gas chromatograph system Standard reports include: Average reports - hourly, 24-hr., weekly, monthly and variable averages Analysis reports - physical property calculations by component and group for analysis and alarms Raw data report - retention times, peak areas, detector number, method, integration start/stop, and peak width for the analysis Calibration report - raw component data, new response factors, retention times, and deviation for last calibration Final calibration report - results of final calibration, response factor and retention time adjustments ENVIRONMENTAL CHAMBER TESTING We provide the most thorough gas chromatograph testing in the world. Prior to shipment, we test nearly every Danalyzer Model 700 in our walk-in environmental test chambers, where temperatures are cycled between 0 F and 130 F for a minimum of 24 hours. This is all part of our commitment to provide analyzers that are capable of providing reliable measurements in the field. BTU Repeatability In Environmental Chamber Model 700 C 9+ Application - Pipeline Gas COLD RAMP COLD SOAK HOT RAMP HOT SOAK Archiving - the last 35 days of each analysis and 64 calibrations can be archived automatically by time/ date stamp. Last chromatogram stored for each sample and calibration stream. BTU 1040 1039 1038 1037 1036 70 o F 130 o F 1035 0 o F 1034 0:00 1:07 2:14 3:21 4:28 5:35 Stated Repeatability (oven temperature): ±0.05% CV Repeatability as tested: ±0.0165% 6:43 7:50 8:57 10:04 11:11 12:18 13:25 14:33 15:40 16:47 17:54 19:01 20:08 21:16 22:23 ELAPSED TIME 17 Jan 04 Deg C Superior measurement stability in extreme climates is tested for every Model 700 Process Gas Chromatographs before it ships. Page 5

MON2000 SOFTWARE The Danalyzer Model 700 Gas Chromatograph is designed to operate unattended. If adjustments are needed, our exclusive MON2000 software allows complete control of your gas chromatographs either locally or remotely. From within MON2000, a user can: Review and modify analytical settings on one screen Upload and display multiple chromatograms on the screen for comparison Upload and trend any of the measured results Export data for use in other third-party applications Overlay multiple chromatograms for troubleshooting and calibration Check original calibration against last calibration The MON2000 software is Windows -based software designed to make analyzer configuration, maintenance and data collection easy. With intuitive drop-down menus and fill-in-the-blank tables, even new users can quickly navigate through the software. The MON2000 software can display both current and multiple archived chromatograms on the screen streamlining the time needed to perform routine analyzer maintenance. MON2000 also has a number of tools built in to help users manage their analyzers such as: Automatic recording of alarms in a log file Event logs that provide a continuous record of all operator changes with time and user name stored Maintenance log scratch pad for keeping track of maintenance or testing done Download and install the latest GPA 2145 and ISO 6976 physical property factors Data collected from the Danalyzer Model 700 can be stored and displayed in a wide range of options such as trend lines on the screen and logs automatically documenting all changes made to the gas chromatograph. Data can also be exported in formats compatible with most third-party Windows applications. Simple dropdown menus Connect to any GC with a mouse click Full featured chromatogram display Powerful Yet Simple MON2000 Software Summary of application event status and time Automatic listing of measured components Quickly add chromatograms to overlay Manually adjust X/Y scale Interactive cursur Display results Save chromatograms to hard drive Page 6

P Q R P Q R Product Datasheet ANALYZER NETWORKING AND DATA COMMUNICATION Danalyzer Gas Chromatographs can be configured in a number of networking and data communication schemes to meet the communication requirements of the natural gas industry. Options include modem, Ethernet, as well as multi-drop RS-485 networks. It is even possible to set up automatic polling for data collection if desired. Data communication options include simple analog and discrete signals as well as Modbus serial links. To preserve the integrity of the analysis data, all Danalyzer Model 700 Gas Chromatographs are capable of storing up to 35 days of analysis or calibration data in the event of loss of communication. All Danalyzer Gas Chromatographs are designed to operate unattended. Occasionally, adjustments to the analyzer analytical method or a review of possible alarms may be needed. Using our exclusive MON2000 software loaded on either a PC or laptop running Windows, you ll have complete control of your gas chromatographs either locally or remotely. Networking Flexibility Whether you want to network gas chromatographs throughout the plant or simply link a single gas chromatograph to a flow computer system, the Danalyzer Model 700 can be configured to handle most of the scenarios: Choice of Ethernet or RS-485 network Can use same network to connect Danalyzer Model 700, Model 500, and Model 1000 Gas Chromatographs Able to connect multiple PC workstations using MON2000 Connectivity to flow computer or SCADA systems using industry standard protocols such as Modbus and OPC Secure Modbus Connectivity For online gas chromatographs, Modbus continues to be the preferred choice to connect to a gas chromatograph network. Our Modbus design avoids the use of central interface cards or computers that can act as a single-point of failure in the Modbus link. Instead, the flow computer or SCADA system can talk directly to each gas chromatograph to gather the data needed. Furthermore, the register and coil addresses can be easily customized to meet the specific data structure of the flow computer or SCADA system. There is also a program built into the MON2000 workstation to test the Modbus link if troubleshooting is needed. Simplified Network Communications - Multiple serial ports with Ethernet option can be field configured to provide redundant data highways. MODEL 700 MODEL 700 MODEL 1000 INTERNET - RS 232C - RS 485/422 - ETHERNET OPTIONAL LAPTOP FOR LOCAL COMMUNICATION MODEL 500 PRINTER / LOGGER ETHERNET - UNLIMITED NUMBER OF GC S MODEL 500 - RS 232C - RS 485/422 - ETHERNET MON2OOO WORKSTATION DCS OPC SERVER MON2OOO WORKSTATION MODEL 700 OPC SERVER MODEL 1000 MODEL 700 REDUNDANT RS 485/422 UP TO 32 GC S MODEL 500 MODEL 700 - RS 232C - RS 485/422 - ETHERNET OPTIONAL LAPTOP FOR LOCAL COMMUNICATION MODEL 500 - RS 232C - RS 485/422 - ETHERNET MON2OOO WORKSTATION Page 7

ACCESSORIES We offer standard and custom gas chromatograph accessories to meet your installation and application requirements. Gas Chromatograph System Enclosures Complete range of gas chromatograph enclosure solutions ranging from simple sun-shields and cabinets to skids systems and shelters 3 - Sided Shelter API 14.1 compliant solutions with heating of sample lines and calibration gas Standard Auxiliary Equipment Sample probes / pressure regulators / filters for a wide range of sample handling requirements Carrier gas systems with dual manifold regulators for uninterrupted operation Calibration gases and heating blankets GAS CHROMATOGRAPH ACCESSORIES Laptop Computer Shelf mounts easily - folds down on side (PN 2-3-0700-143 ) Multi-stream Heated Sample Conditioning System Carrier Manifold "Condulet" Junction Box for quick laptop PC (db9 connector) access Custom-Engineered Sample Systems Any gas chromatograph is only as good as the quality of the sample it measures. Every sample system for Danalyzer Gas Chromatographs is custom-engineered for the specific requirements of the application. Common features include: Heated and open panel designs All components rated for the area classification Automatic calibration / validation available as an option Variety of sample probes to extract a reliable and stable sample Condulet Junction Box Laptop Computer Shelf Sample Probe Calibration Gas with Heating Blanket Page 8

Danalyzer Model 700 Gas Chromatograph CSA Certified Danalyzer GC, 6 or 10 port valves, single or dual detectors Ordering Matrix (must select only 1 option for each column) 77X C W DC 4 SN N S4 612 1N S (example) Code Approvals C CSA A ATEX Code Mounting W Wall-mount P Pipe-mount F Floor-mount Code Power DC 24 VDC AC Universal 85 to 240 VAC Manuals: (one set included with each system) Hardware manual - P/N 3-9000-521 Software manual - P/N 3-9000-522 All Danalyzer Model 700 Gas Chromatographs must be crated for shipment. * Users with rich natural gas applications may require heated sample system ovens and sample transport tubing to insure that the sample is kept above its sample dew point. Consult the factory to determine if heated sample system is needed. Code Digital/Analog I/O 4 5 Digital In; 4 Digital Out; 4 Analog In; 4 Non-isolated Analog Out 8 5 Digital In; 4 Digital Out; 4 Analog In; 8 Analog Out, 4 Non-Isolated/4 Isolated 12 5 Digital In; 4 Digital Out; 4 Analog In; 12 Non-isolated Analog Out Code Serial Communications/Local Keypad-LCD SN Standard/no keypad - LCD {(2) RS232, (1) RS422/486 Factory/Field configurable} EN Extended/no keypad - LCD {(4) RS232, (2) RS422/486 Factory/Field configurable} Code Internal Modem and/or Ethernet N No Modem or Ethernet M Modem only E Ethernet only B Modem and Ethernet X Special (consult factory) Code Internal Stream Switching (Total max. # streams = sample + calibration streams) S4 Standard Up to 4 streams S8 Standard Up to 8 streams D4 Double block and bleed - Up to 4 streams D8 Double block and bleed - Up to 8 streams ES External stream switching - (consult factory) X Special (consult factory) Code Oven Assembly/Application 612 BTU/CV C 6 + / 12 min. 604 BTU/CD C 6 + / 4 min. 6GT BTU/CV C 6 + / 2 min./turbine TS2 Trace H 2 S / 3 min.* LF8 Landfill Gas / 8 min. LF3 Landfill Gas / 3 min. (mole-sieve) 6PS Std. C 6 + with % H 2 S 6PO Std. C 6 + with % Oxygen 6HH Std. C 6 + with Helium/Hydrogen 6TS C 6 + / 12 min and ppm H 2 S / 7 min.* 905 Std. C 9 + and HC Dew X Special Code Sample Conditioning (sample streams only) 1N 1 stream plate 1G 1 stream plate, with Fast Loop/Membrane Filter/Liq. Shut-off 2N 2 stream plate 2G 2 stream plate, with Fast Loop/Membrane Filters/Liq. Shut-off 3N 3 stream plate 3G 3 stream plate, with Fast Loop/Membrane Filters/Liq. Shut-off 4N 4 stream plate 4G 4 stream plate, with Fast Loop/Membrane Filter/Liq. Shut-off 5N 5 stream plate 5G 5 stream plate, with Fast Loop/Membrane Filter/Liq. Shut-off 6N 6 stream plate 6G 6 stream plate, with Fast Loop/Membrane Filter/Liq. Shut-off 7N 7 stream plate 7G 7 stream plate, with Fast Loop/Membrane Filter/Liq. Shut-off O Heated Sample System (Order Separately) X Special (consult factory) Code Application Software S Std. GPA 2172/GPA2145 I ISO 6976;1995 X Special (consult factory) Page 9

Product Application Datasheet Sheet Every Danalyzer Model 700 Gas Chromatograph is custom built for the specific application requested. To request a free quotation, simply fill out the information below and send it to your world area contact information located on the back cover of this datasheet. Name: Title: Company: Address: Your Reference #: Project Name: Process Unit: Stream Name(s): Hazardous Area Classification: Phone #: Fax #: Email: Stream Composition Units Stream 1 Stream 2 Min Normal Max Measure Min Normal Max Measure (For more than two streams, make copies of this page) Stream Temperature Stream Pressure Stream Phase (vapor/liquid) Stream Contaminants Stream 1 Stream 2 Distance to GC from sample point Power: 100-240 VAC ( ) 24 VDC ( ) Mounting: Wall ( ) Pipe ( ) Stand ( ) Data communication Analog output ( ) Modbus ( ) OPC ( ) Printer ( ) Modem ( ) Analyzer network: Ethernet ( ) RS-485 Multi-Drop ( ) Other options: Carrier Gas ( ) Calibration Gas ( ) Start-up ( ) Training Class ( ) Special Instructions: Page 10

Specifications Power: Standard: 24 VDC, (24.5-26.5 VDC) Optional: 90-264 VAC, 47-63 Hz 80 watts start-up; 33 watts nominal Environment: -29 to 60 C (-20 to 140 F) Enclosure Protection Rating: IP66 and NEMA 4X Dimensions (without sample system): Wall-mount: 914mm H x 462mm W x 483mm D (36 H x 18.2 W x 19 D) Pipe-mount: 914mm H x 462mm W x 645mm D (36 H x 18.2 W x 25.4 D) Floor-mount: 1483mm H x 419mm W x 577mm D (58.4 H x 16.5 W x 22.7 D) Mounting: Free-standing (standard); wall-mount or pipe-mount (optional) Approximate Weight (without sample system): 80 kg (175 lbs.) Area Safety Certification Options: CSA: Class 1, Division 1, Groups B, C, D, T4 USA: Class I, Zone 1, Ex d IIB+H2, T4, Enclosure Type 4 Canada: Class I, Zone 1, Ex d IIB+H2, T4, Enclosure Type 4 ATEX: Ex II 2G Ex d IIC T4 Tamb = 60 C IECEx: Ex d IIC T4 Gb Tamb = 60 C Oven: Airless heat sink, maximum 130 C (266 F) Valves: 6-port and 10-port diaphragm chromatograph valves. Other types of valves may be used, such as liquid injection or rotary valves, depending on the application Carrier Gas: Application-dependent. Typically zero-grade helium, nitrogen, or hydrogen Sample Input Pressure Range (recommended): 15-20 psig Carrier Gas Input Pressure Range (recommended): 90-100 psig Detector: Thermal conductivity detector (TCD), flame ionization detector (FID), TCD/TCD or TCD/FID dual detector configurations possible; flame photometric detector (FPD) available (see FPD module data sheet) Gating Options: Fixed-time automatic slope sense gating of peaks Streams: Up to eight streams (including calibration stream) internally controlled; up to 12 streams externally controlled Chromatograms stored/archived internally: Most recent analysis and/or calibration per stream Analog Inputs: Four inputs filtered with transient protection (user scalable and assignable) Analog Outputs: Four non-isolated analog outputs, 4 20 ma (standard); four additional isolated analog outputs or eight additional non-isolated analog outputs (optional) Serial Communication Ports: Three serial ports standard with option for a total of seven. Depending on the port, choice of RS-232, RS-422, and RS-485 is available as well as the Modbus protocol Digital Inputs: Five digital inputs; user assignable Digital Outputs: One gas chromatograph alarm and four user-assignable outputs (2 form A, 3 solid-state optically isolated) Parallel Printer Port: One parallel port available for printed reports Internal Modem (optional): Field-configurable; 300 to 33.6k baud rate Ethernet Card (optional): 10 mbps with RJ-45 port RAM (DATA) Memory Capacity: 128 Mb RAM (standard) Outline and Mounting Details 25.4 22.4 4 OR 2 POLE MOUNT OPTION 15.50 22.7 4X Ø.50 THRU 13.6 26.25 REMOVAL CLEARANCE TYPICAL 56.6 1.56 SAMPLE PLATE 58.4 12.0 36.8 SAMPLE PLATE 16.75 18.2 33.8 RECOMMENDED FROM GROUND OR FLOOR 16.5 22.1 FRONT VIEW FLOOR MOUNT UNIT SIDE VIEW FLOOR MOUNT UNIT FRONT VIEW WALL MOUNT UNIT POLE MOUNT UNIT Page 11

Notes: Emerson Process Management Daniel Measurement and Control, Inc. World Area Headquarters Houston, Texas, USA T: 713-827-6380, F: 713-827-3865 USA Toll Free 1-866-GC-CENTER gc.csc@emerson.com www.daniel.com Calgary, Alberta, Canada, T: 403-279-1879, F: 403-236-1337 Singapore - Asia Pacific, T: +65-6777-8211, F: +65-6770-8001 Stirling, Scotland - Europe, Mid-East, Africa, T: +44-1259-727-222, F: +44-1786-433-606 Daniel Measurement and Control, Inc. and Rosemount Analytical are a wholly owned subsidiaries of Emerson Electric Co., and are divisions of Emerson Process Management. The Daniel name and logo are registered trademarks of Daniel Industries, Inc. The Emerson logo is a registered trademark and service mark of Emerson Electric Co. All other trademarks are the property of their respective companies. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by Daniel s terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time. Daniel does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Daniel product remains solely with the purchaser and end-user. Daniel products are protected by United States and international patents and patents pending. 2010 Daniel Measurement & Control, Inc. All rights reserved. Unauthorized duplication in whole or in part is prohibited. Printed in the USA. Page 12 May 2010