ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories



Similar documents
Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Three-phase monitoring relay CM-PFE

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Three-phase monitoring relays Product group picture

Grid feeding monitoring according to VDE-AR-N 4105 and BDEW CM-UFD.M31

Analog signal converters CC-E I/I Current / current isolators

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

Thermistor motor protection

EMR measuring and monitoring relays

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Pluggable interface relays CR-P Pcb relays

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

RM4TG20 three-phase network control relay RM4-T - range V

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Signal converters Index

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Safety technique. Emergency stop module BO 5988 safemaster

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

48 SERIES Relay interface modules 10 A

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

38 Series - Relay interface modules A

Type: DILM32 10(24V50HZ) Article No.:

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Type: DILM9 10(24VDC) Article No.:

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

PHOENIX CONTACT Features

Manual motor starter MS116

Catalog. Modular DIN rail components Installation contactors

38 Series - Relay interface modules A

49 Series - Relay interface modules A. Features

Technical catalogue. Modular DIN rail components Installation contactors

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Signal converters Index

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Power Supplies 3. SDN-P DIN Rail Series

80 Series - Modular timers 16 A. Features

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Technicaldata General

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

MasterINTERFACE 39 Series - Relay interface modules

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Relés e Contatores de Estado Sólido SIRIUS

MasterINTERFACE 39 Series - Relay interface modules

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Redundancy Module QUINT-DIODE/40

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

80 Series - Modular timers 16 A. Features

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

PHOENIX CONTACT - 01/2007

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

40 Series - Miniature PCB/Plug-in relays A. Features

APD / Outputs 19" DC/DC Converter, 50 Watt

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

STRATO LED Drivers 70W, Single output

Voltage Regulator SPAU 341 C. Product Guide

Contact expansion modules

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

15 Series - Electronic step relay and dimmer. Features SERIE

R.C.C.B. s two-pole LEXIC

Quick Connect. quick - simple - efficient.

Manual Motor Starter MS 116 up to 16 A Technical Data

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Contact expander modules

Waveguide Access Point WGA631. Product Guide

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Digital input modules

Telephone- and leased line modem for industrial applications TD-36

7 - Phaseo power supplies and transformers

MINI MCR-SL-R-UI(-SP)

Thermal-Magnetic Circuit Breaker M1-..

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

ZS10 Screw Clamp Terminal Block

E-STOP relays, safety gate monitors

Transcription:

2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used to monitor single-phase mains Threshold value for the 10 minutes average value adjustable (110-115% of Us) Start-up delay ts1 prior to first grid connection and after a short-term interruption, Restart delay ts2, Powered by the measuring circuit True RMS measuring principle 2 c/o (SPDT) contacts 3 LEDs for status indication R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault message Adjustment of the threshold value for the 10 minutes average value Selection of neutral conductor, connected or not 6 Marker label Approvals TÜV Marks a CE Order data Type Rated control supply voltage = Measuring voltage Order code 3 x 400 V AC (L-L) / 230 V AC (L-N) 1SVR 630 736 R0300 Order data - Accessories Type Description Order code ADP.01 Adapter for screw mounting 1SVR 430 029 R0100 MAR.01 Marker label 1SVR 366 017 R0100 COV.01 Sealable transparent cover 1SVR 430 005 R0100 Application The is a monitoring relay for feeding in three-phase mains. The device is connected between the grid connected, decentral electrical energy source such as photovoltaic systems, wind turbines, block-type thermal power stations, and the public grid. In case the public grid is disconnected due to any reason, for instance during maintance work, the recognizes this powerless situation. Then, in conjunction with a switching device, the disconnects the decentral electrical energy source from the public grid. The device detects overvoltage and undervoltage (voltage increase and decrease protection) as well as any changes in grid frequency (frequency increase and decrease protection) in accordance with DIN V VDE V 0126-1-1. The connection of the neutral conductor is configurable. The threshold value for the 10 minutes average value is adjustable. The is also suitable for monitoring single-phase mains. For this, all three external conductors (L1, L2, L3) have to be jumpered and connected as one single conductor. ABB 1

Automatized grid connection instead of a permanently accessible switching point with a disconnection function L1 L2 L3 N Low voltage grid 2CDC 252 022 F0209 L1 L2 L3 N 15 CM-UFS.x <U< <f< 25 16 18 26 28 Coordination of short-circuit protection, welding free K1 K2 External switch-off conditions May also be the inverter output. In this case, apply the signal of relay R2 to the relevant input Inverter(s) Generator(s) Power plant 2 ABB

Operating mode Configuration of the device is made by means of setting elements accessible on the front of the unit and signalling is made by means of front-face LEDs. Adjustment potentiometer Threshold value for the 10 minutes average value The threshold value for the 10 minutes average value can be adjusted within a range of 110-115 % of the rated control supply voltage U s by means of the potentiometer Average % with a linear scale. The value specified by the network provider has to be set! Rotary switch Neutral conductor connection The connection of the neutral conductor is configurable by means of the rotary switch Function. Neutral conductor not connected N Neutral conductor connected To avoid any faulty tripping, the selection has to be made prior to commissioning. Do not change the switch setting during operation! Threshold values according to DIN V VDE V 0126-1-1: February 2006 Overvoltage Undervoltage Overfrequency Underfrequency 10 minutes average value Threshold value > 115 % of U s < 80 % of U s > 50,2 Hz < 47,5 Hz 110-115 % of U s, adjustable Attention: The threshold value is specified by the network provider! LEDs Function R/T: yellow LED F1: red LED F2: red LED Output relay energized V - - Delay active W - - Overvoltage - V - Undervoltage - - V Overfrequency - W - Underfrequency - - W Exceedance of the average value - V V Phase failure - V W ABB 3

Function description / diagrams Function diagram legend G Control supply voltage not applied / Output contact open / LED off B Control supply voltage applied / Output contact closed / LED glowing Function of the yellow LED The yellow LED is flashing during timing and turns steady as soon as the output relays are energized. Phase failure monitoring Applying control supply voltage begins the fixed start-up delay t S1. When t S1 is complete and all phases are present with correct voltage and frequency, the output relays energize. They de-energize instantaneously if a phase failure occurs. The fault is indicated by LEDs. As soon as all 3 phases are present again, the output relays re-energize automatically after the fixed restart delay t S2 is complete. L1, L2, L3 (N) Measuring value 15-18, 25-28 15-16, 25-26 F1: red LED F2: red LED R/T: yellow LED t S1 L1, L2, L3 L1, L2 L1, L2, L3 t S1 = Start-up delay prior to first grid connection and after a short-term interruption, t S2 = Restart delay, L3 t S2 2CDC 252 018 F0209 Over- and undervoltage monitoring Applying control supply voltage begins the fixed start-up delay t S1. When t S1 is complete and all phases are present with correct voltage and frequency, the output relays energize. If the voltage to be monitored exceeds or falls below the fixed threshold value, the output relays de-energize instantaneously. The fault type is indicated by LEDs. As soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 5 %, the output relays re-energize after the fixed restart delay t S2 is complete. L1, L2, L3 (N) > U > U - Hyst. Measuring value < U + Hyst. < U t S1 t S2 < t S2 < t S2 2CDC 252 016 F0209 15-18, 25-28 15-16, 25-26 F1: red LED F2: red LED R/T: yellow LED t S1 = Start-up delay prior to first grid connection and after a short-term interruption, t S2 = Restart delay, 4 ABB

Over- and underfrequency monitoring Applying control supply voltage begins the fixed start-up delay t S1. When t S1 is complete and all phases are present with correct voltage and frequency, the output relays energize. If the frequency to be monitored exceeds or falls below the fixed threshold value, the output relays deenergize instantaneously. The fault type is indicated by LEDs. As soon as the frequency returns to the tolerance range, taking into account a fixed hysteresis, the output relays re-energize after the fixed restart delay t S2 is complete. L1, L2, L3 (N) > f > f - Hyst. Measuring value < f + Hyst. < f t S1 t S2 < t S2 < t S2 2CDC 252 020 F0209 15-18, 25-28 15-16, 25-26 F1: red LED F2: red LED R/T: yellow LED t S1 = Start-up delay prior to first grid connection and after a short-term interruption, t S2 = Restart delay, 10 minutes average value monitoring Applying control supply voltage begins the fixed start-up delay t S1. When t S1 is complete and all phases are present with correct voltage and frequency, the output relays energize. The voltages of the individual phases are measured over a period of 10 minutes and the average value is calculated. If the 10 minutes average value of a phase exceeds the set threshold value, the output relays de-energize instantaneously. The fault is indicated by LEDs. As soon as the 10 minutes average value drops again below the set threshold value, the output relays reenergize instantaneously. L1, L2, L3 (N) > U > U - Hyst. Measuring value 15-18, 25-28 15-16, 25-26 F1: red LED F2: red LED R/T: yellow LED t S1 t S1 = Start-up delay prior to first grid connection and after a short-term interruption, 2CDC 252 002 F0209 ABB 5

Connection diagram L1 N L2 L1 L2 L3 15 N 26 25 16 15 L3 25 16 18 26 28 28 18 2CDC 252 036 F0b08 L1, L2, L3, N Control supply voltage = Measuring voltage 15-16/18 Output contacts - 25-26/28 closed-circuit principle 6 ABB

Data at T a = 25 C and rated values, unless otherwise indicated Type Input circuit - Supply circuit L1, L2, L3 L-N Rated control supply voltage U s = Measuring voltage 3 x 400 V AC 3 x 230 V AC Rated control supply voltage U s tolerance -20...+20 % Control supply voltage range 3 x 300-500 V AC 3 x 180-280 V AC Rated frequency 50 Hz Frequency range Typical current / power consumption Power failure buffering time 45-55 Hz 23 ma / 16 VA min. 20 ms Input circuit - Measuring circuit L1, L2, L3 L-N Monitoring functions Phase failure J Over-/undervoltage Over-/underfrequency 10 minutes average value J Measuring range Voltage range 3 x 320-460 V AC 3 x 184-264.5 V AC Frequency range J J 45-55 Hz Threshold values Overvoltage 115 % of U s, fixed Undervoltage Overfrequency Underfrequency 80 % of U s, fixed 50.2 Hz fixed 47.5 Hz fixed 10 minutes average value 110-115% of U s, adjustable Hysteresis related to Over-/undervoltage 5 % fixed the threshold value Over-/underfrequency 20 mhz fixed Rated frequency of the measuring signal 50 Hz Frequency range of the measuring signal 45-55 Hz Maximum measuring cycle 50 ms Maximum reaction time (time between Over-/undervoltage < 120 ms fault detection and change of switching status of the relay) Over-/underfrequency < 100 ms 10 minutes average value without delay Accuracy within the rated control supply voltage tolerance iu 0.5 % Accuracy within the temperature range iu 0.06 % / C Measuring method True RMS Timing circuit Start-up delay t S1 prior to first grid connection and after a short-term interruption Restart delay t S2 Accuracy within the rated control supply voltage tolerance it 0.5 % Accuracy within the temperature range it 0.06 % / C Indication of operational states 1 yellow LED, 2 red LEDs Details see operating mode and function description/diagrams Outpur circuits 15-16/18, 25-26/28 Kind of output Relay, 1 x 2 c/o (SPDT) contacts Operating principle 1) closed-circuit principle Contact material AgNi alloy, Cd free Rated operational voltage U e (IEC/EN 60947-1) 250 V Minimum switching voltage / switching current 24 V / 10 ma Maximum switching voltage / switching current see load limit curve Rated operational current I e AC12 (resistive) 230 V 4 A (IEC/EN 60947-5-1) AC15 (inductive) 230 V 3 A DC12 (resistive) 24 V 4 A DC13 (inductive) 24 V 2 A Mechanical lifetime 30 x 106 switching cycles Electrical lifetime (AC12, 230 V, 4 A) 0.1 x 106 switching cycles Short-circuit resistance, n/c contact 6 A fast-acting maximum fuse rating n/o contact 10 A fast-acting ABB 7

Data at T a = 25 C and rated values, unless otherwise indicated Type General data Mean time between failures (MTBF) Duty time 100 % Repeat accuracy (constant parameters) < w 0,5 % Dimensions (W x H x D) 22.5 x 78 x 100 mm (0.89 x 3.07 x 3.94 in) Weight 0.14 kg (0.31 lb) Monting DIN rail (EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units not necessary Degree of protection enclosure / terminals IP50 / IP20 Electrical connection Wire size fine-strand with/without wire end ferrule 2 x 0.75-2.5 mm² (2 x 18-14 AWG) rigid 2 x 0.5-4 mm² (2 x 20-12 AWG) Stripping length 7 mm (0.28 in) Tightening torque 0.6-0.8 Nm (5.31-7.08 in.lb) Environmental data Ambient temperature range operation / storage -25...+60 C / -40...+85 C Damp heat, cyclic (IEC/EN 60068-2-30) 2 x 12 h cycle, 55 C, 95 % RH Climatic category (IEC/EN 60721-3-1) 3K3 Vibration, sinusoidal (IEC/EN 60255-21-1) Class 2 Shock (IEC/EN 60255-21-2) Class 2 Isolation data Rated insulation input circuit / output circuit 600 V voltage U i output circuit 1 / output circuit 2 300 V Rated impulse withstand voltage U imp input circuit 6 kv; 1.2/50 µs (VDE 0110, IEC/EN 60664) output circuit 4 kv; 1.2/50 µs Test voltage between all isolated circuits (type test) 2.5 kv, 50 Hz, 1 s Basis isolation input circuit / output circuit 600 V Protective separation (VDE 0106 part 101 and 101/A, IEC/EN 61140) input circuit / output circuit Pollution degree (VDE 0110, IEC/EN 60664, UL 508) 3 Overvoltage category (VDE 0110, IEC/EN 60664, UL 508) III Standards Product standard IEC/EN 60255-6, DIN V VDE V 0126-1-1: February 2006 Further standards EN 50178, EN 61727 Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC RoHS Directive 2002/95/EC Electromagnetic compatibility Interference immunity IEC/EN 61000-6-1, IEC/EN 61000-6-2 Electrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3 (6 kv / 8 kv) Electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 Level 3 (10 V/m) Fast transients (Burst) IEC/EN 61000-4-4 Level 3 (2 kv / 5 khz) Powerful impulses (Surge) IEC/EN 61000-4-5 Level 4 (2 kv L-L, L-N) HF line emission IEC/EN 61000-4-6 Level 3 (10 V) Resistance to harmonics IEC/EN 61000-4-13 Class 3 Interference emission IEC/EN 61000-6-3, IEC/EN 61000-6-4 Electromagn. field (HF radiation resistance) IEC/CISPR 22, EN 50022 Class B HF line emission IEC/CISPR 22, EN 50022 Class B 1) Closed-circuit principle: Output relay(s) de-energize(s), if measured value exceeds or falls below the adjusted threshold value yes 8 ABB

Techical diagrams Load limit curve AC load (resistive) DC load (resistive) U V 300 200 100 80 60 50 40 30 20 2CDC 252 194 F0105 U V 300 200 100 80 60 50 40 30 20 2CDC 252 193 F0105 10 0,1 0,2 0,5 1 2 4 6 10 I A 10 0,1 0,2 0,5 1 2 4 6 10 I A Derating factor F at inductive AC load F 1.0 0.9 0.8 0.7 0.6 0.5 2CDC 252 192 F0205 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ Contact lifetime Switching cycles 250 V resistive load 2CDC 252 148 F0206 Switching current [A] ABB 9

Dimensions in mm 2CDC 252 031 F0b03 Dimensions - Accessories in mm 4,5.177 62,5 2.46 60 2.36 11,5.453 10.394 22,5.886 2CDC 252 187 F0005 3A11 20.787 8.315 2CDC 252 186 F0005 ADP.01 - Adapter for screw mounting MAR.01 - Marker label 2.70 22,5.886 7.275 3,5.138 68,5 2CDC 252 185 F0005 front-to-back size 107 COV.01 - Sealable transparent cover Further documentation Document titel Document type Document number Electronic Products and Relays Technical catalogue 2CDC 110 004 C020x ; CM-UFS.2 Instruction manual 1SVC 630 540 M0000 You can find the documentation online at www.abb.com/lowvoltage R Control Products R... 10 ABB

ABB As part of the on going product improvement, ABB reserves the right to modify the characteristics of the products described in this document. The information given is noncontractual. For further details please contact (www.abb.com/contacts) the ABB company marketing these products in your country. Document number. 2CDC 112 141 D0201 (02/2010) ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82, 69123 Heidelberg, Germany Postfach 10 16 80, 69006 Heidelberg, Germany Internet http://www.abb.com/lowvoltage R Control Products You can find the address of your local sales organisation on the ABB homepage http://www.abb.com/contacts R Low Voltage Products