SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Siemens ENEAS solutions for substation automation and protection

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

PCS0100en Persy Control Services B.V. Netherlands

Straton and Zenon for Advantech ADAM Copalp integrates the straton runtime into the ADAM-5550 device from Advantech

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Permissible ambient temperature Operation Storage, transport

40.3. Control Relays and Timers

MLC TM Maximum Productivity and Versatility for Control without Compromise!

S-series DeviceNet Interface Card

INDUSTRIAL GATEWAYS VPN ROUTERS SERIAL DEVICE SERVERS

S-series SQ Controller

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Efficient remote access to machines and plants with SIMATIC

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Electronic Control Devices The European Product Catalogue 2007

Disturbance Recoder SPCR 8C27. Product Guide

Modular I/O System Analog and Digital Interface Modules

PROFIBUS fault finding and health checking

Charge Controller CC611/CC612 Preliminary datasheet

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

SNAP-SCM-PROFI Communication Module

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Introduction to PROFIBUS and PROFINET

connecdim Gateway G1 Ethernet TCP/IP to DALI

CPUs - CPU PN/DP

Using installed Fieldbus Wiring to carry Ethernet Communications

M-series FOUNDATION Fieldbus I/O

T7560A,B,C Digital Wall Module

Power network telecommunication

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

SIMATIC VS720A and VS720-S series Intelligent cameras with PROFINET

SIMATIC S It s the interplay that makes the difference. SIMATIC Controller. Answers for industry.

NEW. EVEN MORE data acquisition and test stand automation

Rosemount 333 HART Tri-Loop


OZW30. Central Unit SYNERGYR

Electronic Control Devices The European Product Catalogue 2007

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

Real-time Video Monitoring Increases the Efficiency of SCADA Process Management

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Model: DC-A2IO Advanced HVAC Controller

Climate Ready Control Systems Technical Specifications

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G

In-Sight Hardware specifications

SCADA System Fundamentals

Ponto Series. A new concept for automation

Installation manual. Generator Paralleling Controller GPC multi-line C

The CP FO provides access to different communication services of the PROFIBUS bus system:

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Digital and Analog I/O

MINI MCR-SL-R-UI(-SP)

Telephone- and leased line modem for industrial applications TD-36

ROC Protocol Specifications Manual

White paper The future role of ethernet and the trend to decentralised control solutions

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

Easy. Modular. Universal. Laboratory automation with SIMATIC PCS 7 LAB SIMATIC PCS 7. Answers for industry.

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

PROFIBUS AND MODBUS: A COMPARISON

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

SYSTEM DESCRIPTION Termination Boards

BL compact multiprotocol station for Industrial Ethernet SSI interface BLCEN-1M12MT-1SSI

M2M/IoT Solutions.

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Data sheet SLIO CPU 015 (015-CEFPR00)

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

CP Page 1342 Mar 2008 Siemens ITS

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Remote Monitoring and REC 501 Control Unit Product Guide

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Industrial Communication

Optimize your simple machines... Modicon M218 Selection Guide

The CP provides access to different communication services of the PROFIBUS bus system:

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

154 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local

1. Introduction Communication in Substation

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Duct Humidity Transmitter

Rack mounted telephone- and leased line modem for industrial applications

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

What ensures easy and fast wiring?

emobility WAGO Leading the Charge

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

ABB Drives. User s Manual HTL Encoder Interface FEN-31

TrueAlarm Fire Alarm Systems

TX OPEN RS232/485 module

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Transcription:

Automation Unit Flexible automation and telecontrol Power Transmission and Distribution

Outstanding performance: Automate simply with Highly complex and yet fully transparent automation solutions are not a problem with the new automation unit. The ACP 1703 system concept creates the necessary technological conditions for combining automation and telecontrol in one device. The mechanical design is based on intelligent terminal modules that can be readily mounted on 35-mm rails. Versatility is essential permits systematic reduction of hard-wired I/O interfaces through the direct connection of actuators and sensors with wire crosssections of up to 2.5 mm 2. Modules for binary input and output up to 220 VDC also open up streamlining potentials on the interposing level. For decentral input/output, individual modules can be distributed as much as 200 m from the master controller. Flash Card puts everything on one card The receives parameter data via a flash card. That means the required parameters will always be available locally and loading via PCs is no longer necessary. In the event that servicing is required, replacing the component is a simple matter of plug & play, because you can very easily import the parameter configuration into the replacement component using the flash card. Therefore and also thanks to the comprehensive remote diagnostics functions you can do more to reduce downtimes to a minimum. Rising demands for efficiency in nearly all processes require increasingly innovative automation solutions to achieve a more comprehensive and safer utilization of primary equipment. A prerequisite for this is automation systems such as with various communications interfaces and peripheral elements that can be expanded by adding modules. understands your system allows you to utilize a host of different media for local and remote communication. The universal use of the IEC 60870-5-101/103/104 standards guarantees consistent addressing from acquisition to output. IEC 61850 is also supported. The use of many third-party protocols, however, also ensures the seamless integration into existing automation networks, thereby guaranteeing the long-term protection of your previous investments. Consistently simple engineering An essential aspect in the overall economic assessment of a process is the costs for the erection and maintenance of automation systems. You re especially on the safe side with the SAT 1703 automation family. That s because the use of the object-oriented engineering system SAT Toolbox II makes it possible to utilize the properties of the same types of primary units and equipment (such as pumps, circuit-breakers, feeders, etc.) also for the parameter configuration. In addition, the close interfacing with the design tool such as ELCAD ensures the consistent, uniform documentation of the global system all the way down to the circuit diagram level. Open-loop and closed-loop control functions are created in CAEx plus according to IEC 61131-3, thereby considerably reducing the necessary staff training times. SAT Toolbox II allows you to carry out all engineering, from system diagnostics to online testing, also from remote locations.

: The main benefits at a glance offers you automation with integrated telecontrol for hydroelectric power stations (such as the TC 1703 turbine controller), distribution and transmission of electric power, oil and gas pipelines, traffic (railroads, tunnels, etc.). provides powerful communication with up to four serial interfaces, serial and LAN/WAN communication according to IEC 60870-5-101/103/104, IEC 61850, Profibus DP, and many third-party protocols. Simplified service through storing of parameters and firmware on flash card; thus modules can be replaced via plug & play, even without a tool., the intelligent terminal on 35-mm rails: direct connection of actuators and sensors through wire cross-sections of up to 2.5 mm 2, distributable peripherals, and binary input/output also for 110/220 VDC. Simple engineering thanks to the creation of open-loop and closed-loop control functions according to IEC 61131-3, object orientation, and consistent data management, as well as the option to perform all engineering tasks from remote locations as well.

Process control system SAT Toolbox II IEC 60870-5-101 NTP IEC 60870-5-104 Master control element A is an automation unit within the SAT 1703 system family, consisting of the master control element and the peripheral elements that can be expanded by adding modules and arranged in distributed locations. Profibus DP (optional) 16 mbps Peripheral elements in practical use Master control element Up to four communications interfaces via insertable serial interface modules for: serial communication (point-to-point, multipoint, and dial-up traffic) LAN/WAN (Ethernet) Profibus DP Interfacing of up to 16 peripheral elements via the serial Ax-1703 peripherals bus (16 mbps) Function diagram design according to IEC 61131-3 with CAEx plus for open-loop and closed-loop control functions Configurable telecontrol functions with and without time tagging Time synchronization via minute pulse, time signal receiver, serial communications link or NTP server (LAN/WAN) Parameter setting, diagnostics, and testing by SAT Toolbox II, both locally or from remote locations Storing of parameters and firmware on flash card Peripheral element One peripheral element consists of a power supply, peripheral interface and up to eight I/O modules Direct connection of the signal cables via pull-off screw terminals Acquisition, processing, and output of process data Exchange of process data with the master control element via the serial Ax-1703 peripheral bus

Technical data Model number Master control element CP-6003/CPC65 Processing and communication Peripheral elements Periphery interfacing Power supply I/O modules PE-6400 PE-6401 PS-6620 PS-6630 PS-6632 DI-6100 DI-6101 DI-6102 DI-6103 DO-6200 DO-6212 AI-6300 AI-6303 AI-6307 AI-6310 AO-6380 TE-6420 TE-6450 Periphery interfacing for A x 1703 electrical peripherals bus Periphery interfacing for A x 1703 optical peripherals bus Power supply module 24 60 VDC Power supply module 24 60 VDC EMC+ Power supply module 110 220 VDC EMC+ Binary input 2 x 8, 24/60 VDC Binary input 2 x 8, 110 220 VDC Binary input 2 x 8, 24 60 VDC 1ms Binary input 2 x 8, 110/220 VDC 1ms Binary output transistor 2 x 8, 24 60 VDC Binary output relay 1 x 8, 24 220 VDC/230 VAC Analog input 2 x 2, ±20 ma/±10 ma/±10 V Direct transformer input (4 x 220 V, 3 x 6 A) Analog input 2 x 2, ±5 ma Analog input 2 x 2 Pt100 Analog output 4 x ±20 ma/±10 ma/±10 V Speed measurement 2 x 2 5 VDC/24 VDC/NAMUR Position measurement 2 x 2 SSI/RS-422 Open-loop and closed-loop control functions 256 kb for user programs, approx. 50,000 variables and signals, 2,000 of which buffered, 250 buffered setpoint values Third-party protocols Modbus, DNP 3.0, IEC 61107,... EMC IEC 60870-2, IEC 60255, IEC 61000, EN 50082,... Supply voltage 24 60 VDC +30 %/ 20 % Temperature range Master control element: 25... +65 C (depending on hardware configuration) Peripheral element: 25... +70 C Relative humidity 5 to 95 % non-condensing (IEC 60654, IEC 60870-2) Vibration and shock resistance IEC 60068-2, IEC 60870-2-2 Cl. Bm, IEC 60255-21 Cl. 1 Dimensions Master control element: 306 x 155 x 75 (W x H x D) Peripheral element: 630 x 127 x 72 (W x H x D) = fully equipped peripheral element with 8 I/O modules

Siemens AG Power Transmission and Distribution Energy Automation Division P.O. Box 4806 90026 Nuremberg Germany www.siemens.com/energy The information in this document contains general descriptions of the technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. Subject to change without prior notice Order-No. E50001-U321-A252-X-7600 Printed in Germany Dispo 06200 TH 345-060135 101790 PA 04062.0 If you have any question about Power Transmission and Distribution, our Customer Support Center is available around the clock. Tel.: +49 180/524 70 00 Fax: +49 180/524 24 71 (Subject to changes, e.g.: 12 ct/min.) E-mail: support.energy@siemens.com www.siemens.com/energy-support