MP8000 Series Pneumatic Valve Actuators



Similar documents
Stainless Steel Single and Dual Circulation Kits

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

VG7000 Series Bronze Control Valves

A-4000 Oil Indicator

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

POWERS Controls No. 4 Pneumatic Damper Actuator

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

VG2000 Series Cast Iron Flanged Globe Valves

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual

T and T Single Input Receiver-Controllers Installation and Calibration

Rebuild Instructions for and Transmission

V47 Series Temperature Actuated Modulating Water Valves

Diaphragm Control Valves FLUXOTROL Series I and Series 25 Installation and Maintenance Instructions

2100 AD Mirror Elevator Ball Nut Replacement Procedure

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations

VG7000 Series Bronze Control Valves

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

Series 2700A Control Valve. Operation and Maintenance INTRODUCTION

430 Power/Electronics Replacement

Fisher CV500 Rotary Globe Control Valve

PRESSURE REDUCING CONTROL VALVE

Baumann Flexsleev Sanitary Control Valve

Trunnion-Design Ball Valves

Rollator Cane and Brake Replacement SAFETY SUMMARY (CONTINUED)

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

SCION tc COIL OVER SUSPENSION Preparation

OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

Fisher 377 Trip Valve

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

Fisher 377 Trip Valve

2740 Whitten Rd Bldg 103 Memphis, TN Telephone

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

Fisher 2625, 2625SST, and 2625NS Volume Boosters

Baumann Way Bronze or Stainless Steel Control Valve

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

DiscPlus DX195 and DX225 Air Disc Brakes

758 Heavy-duty Ratchet Guy Wire Cutter

Style 9168 Field Service Kit Black Max Piston intake valve

2.4M SERIES 1241 ANTENNA

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

A99B Series Temperature Sensors

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

T-4000 Series Room Thermostat Adjusting Instructions*

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Baumann Mikroseal Control Valve

2006 HEADSHOK Service Video #1

Fisher 657 and 667 Diaphragm Actuators

Char-Lynn Hydraulic Motors. Repair Information. W Series Geroler Motors 002, 003. April, 1999

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual Declutchable Worm Gear

Front brakes (FN- 3), servicing

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

FRONT TURN SIGNAL RELOCATION KIT

Installation Guide 2010 BMW S1000RR Full Exhaust System

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Fuel Injection Pump, Rotary ( )

Pulleys and Belt. Install the Major Accessory and Pulley. Install the Motor Pulley NOTE. Align the Motor Pulley and the Tool Pulley NOTE

Service Manual Rol-Lift

DYNA RIDER FOOTBOARD KIT

S&G Model 2937 Group 1 Combination Lock

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

MODEL G300 BRAKE BLEEDER

Baumann 24000SB Barstock Control Valve

Round Housing with Side Ports

MGB Chrome Bumper Conversion

Installation Instructions S

INSTALLATION INSTRUCTIONS COMPETITION SERIES COILOVER SUSPENSION SYSTEM 03+ Scion xb

TECHNICAL DATA. Dry 122a. November 12, 2013

Universal Adjustable Fuel Pressure Regulator

V46 Pressure-Actuated Water-Regulating Valve

Experience In Motion. Valtek Spring Cylinder Linear Actuators

Installation Instructions

TYPE E Main Valve Sizes 3 /8 through 12

Installation Instructions

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Self Purging Liquid Trap (SPLT ) User s Manual

Operating Instructions Parts List Manual Scissor Lift Pallet Truck

GPS AutoSteer System Installation Manual

TABLE OF CONTENTS. Section 1 - Assembling your new pit bike.

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

Fisher 249 Caged Displacer Sensors

Fisher EDR and ETR easy-e Valves

Machine needle shut-off nozzle type HP

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Transcription:

14-1161- 9, Rev. A Technical Bulletin MP8000 Issue Date March 2016 MP8000 Series Pneumatic Valve Actuators Pre-Assembly Details Page 3 MP8000 Actuator Components 3 Tools Required to Assemble an MP8000 Actuator to a Valve Body 4 Theory of Operation 5 Mounting Procedure 7 Mounting to VG2000 Series and V-5000 Series Iron Valves 7 Mounting to VG7000 Series Bronze Control Valves 14 Reversing the Action of the MP8000 Actuator 23 Reversing From Spring-Return-Up to Spring-Return-Down 23 Reversing From Spring-Return-Down to Spring-Return-Up 24 MP8000 Actuator Maintenance and Repair 25 2016 Johnson Controls, Inc. 1 Part No. 14-1161-9, Rev. A www.johnsoncontrols.com Code No. LIT-977258

2 Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators

Pre-Assembly Details MP8000 Actuator Components A F D B C E H G Figure 1: MP8000 Actuator Components Table 1: MP8000 Actuator Components Item Description Quantity A Actuator 1 B Metric Nuts and Washers 8 C Connector 1 D Actuator Stem Bolt 1 E Jam Nuts 2 F Anti-Rotation Pin 1 G Yoke Nut 1 H Yoke 1 Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators 3

Tools Required to Assemble an MP8000 Actuator to a Valve Body Table 2: Tools Required Description Brass Valves Iron Valves MP82, MP83 MP84, MP85 MP82, MP83 MP84, MP85 MP86, MP87 3/16 in. Open End Wrench X X 1/4 in. Open End Wrench X X X 7/16 in. Open End Wrench X X 9/16 in. Open End Wrench X X X X X 5/8 in. Open End Wrench X X X X X 1 in. Open End Wrench X X X X X 1-3/8 in. Open End Wrench X X 10 mm Open End Wrench X X 13 mm Open End Wrench X X X 7/32 in. Allen Wrench* X X X X X MP8000-6012 Repair Tool Kit** X X X X X * Used when reversing Allen-head set screw. ** Used for mounting spring-return-down actuators only. 4 Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators

Theory of Operation MP8000 Series Pneumatic Valve Actuators are designed to accurately position chilled water, hot water, and steam control valves in response to a pneumatic signal from a controller. Air pressure from a pneumatic controller is applied to the diaphragm of the actuator, which moves the piston against the fluid and actuator spring forces. The piston will move the valve stem and plug until the diaphragm pressure balances the actuator return spring force and the fluid forces. Reducing the air pressure permits the spring to return the valve plug to its normal position. With no control air pressure applied to the diaphragm, the valve is in the normal position. For applications requiring stable, accurate control and sequencing, a V-9502 Pneumatic Valve Actuator Positioner or an EPP-1000 Electro-Pneumatic Actuator Positioner is available for mounting in the field. For more information regarding these positioners, refer to the V-9502 Pneumatic Valve Actuator Positioner Product Bulletin (LIT-977265) or the EPP-1000 Series Electro-Pneumatic Positioners Product Bulletin (LIT-2681270). Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators 5

6 Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators

Mounting Procedure Mounting to VG2000 Series and V-5000 Series Iron Valves When mounting a V-9502 Pneumatic Valve Actuator Positioner or an EPP-1000 Electro-Pneumatic Valve Actuator Positioner to an MP8000 Series Actuator, refer to the instructions included with the positioner.! CAUTION: Personal Injury Hazard. If the valve body is installed in a system, isolate the valve and bleed off the system pressure. Failure to do so may result in personal injury. To perform the basic mounting procedure for Normally Open (N.O.), Normally Closed (N.C.), and three-way mixing valves (no positioner), proceed as follows: Actuator Stop Nut Connector Metric Nuts and Washers Lock Washer Actuator Stem Bolt Yoke Figure 2: Disassembling the Yoke 1. Remove the metric nuts and washers, yoke, connector, actuator stem bolt, and lock washer from the MP8000 Actuator and retain for later use. Note: When removing the actuator stem bolt, be careful not to turn the actuator stop nut. If the stop nut is also turned, the factory calibration of the actuator will be affected. In order to hold the actuator stop nut securely in place while removing the actuator stem bolt, it may be necessary to pressurize the actuator and stroke the valve in order to gain access to the actuator stop nut. Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators 7

Stem Down Stem Up Packing Nut Bonnet Nut Figure 3: Preparing the Valve 2. Push the valve stem down as far as it will go into the valve. 3. Remove the packing nut and retain. 4. Where applicable, remove and discard the bonnet nut. Yoke Stem Jam Nut Packing Nut Yoke Nut Figure 4: Assembling the Yoke 5. Secure the yoke to the valve bonnet using the yoke nut included with the actuator mounting kit. Position the centering boss of the yoke nut so that it faces the valve (as illustrated in Figure 4). Hand tighten only. 6. Reinstall the packing nut retained in Step 3, and tighten it 1/6 of a turn past hand tight. 7. Thread the lower stem jam nut (included with the valve) fully onto the valve stem. 8 Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators

Actuator Stop Nut Connector Anti-Rotation Pin Hole Lock Washer Actuator Stem Bolt Figure 5: Attaching the Connector (Spring-Return-Up Models) 8. For spring-return-up models, attach the connector to the actuator stop nut using the 7/16-20 x 7/8 in. actuator stem bolt and lock washer (included with the actuator). Engage the actuator stem bolt approximately three turns into the actuator stop nut; the connector will be loose. Actuator Stem Connector Anti-Rotation Pin Hole Lock Washer Actuator Stem Bolt Figure 6: Attaching the Connector (Spring-Return-Down Models) For spring-return-down models, attach the connector to the actuator stem using the actuator stem bolt and lock washer (included with the actuator). Hand tighten only. Note: The connector must be oriented so that the holes for the anti-rotation pin are closest to the valve body. Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators 9

Threaded Studs Connector Metric Nuts and Washers Yoke Figure 7: Attaching the Actuator to the Yoke Spring-Return- Up Models For spring-return-up action, proceed as follows: 9. Locate the four threaded studs on the actuator housing adjacent to the actuator stop nut, and install the actuator onto the yoke. 10. Secure the actuator to the yoke with the four metric nuts and washers (included with the actuator). Extend the valve stem until it engages the connector and tighten the metric nuts securely. Also hand tighten the actuator stem bolt. The connector should be free to move. Anti-Rotation Pin Connector Figure 8: Installing the Anti-Rotation Pin 11. Align the connector with the yoke slot and insert the anti-rotation pin. Tighten the anti-rotation pin securely in place. 12. Apply enough supply air to the actuator in order to move the actuator stem bolt down at least 1/8 in. (3 mm), then tighten the actuator stem bolt securely. Note: Do not rotate the actuator stop nut while tightening the actuator stem bolt; doing so may change the start point of the actuator. 13. Disconnect the supply air. 10 Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators

1/32 in. Gap Actuator Stop Nut Upper Stem Jam Nut Lower Stem Jam Nut Figure 9: Securing the Valve Stem 14. Fully extend the valve stem into the connector hole and thread the upper stem jam nut (included with the valve) onto the valve stem, down against the connector. For N.C. and three-way mixing valves only, tighten the upper stem jam nut until there is a 1/32 in. gap between the actuator stop nut and the brass bearing holder. 15. Thread the lower stem jam nut up against the connector and tighten it securely in place. 16. Tighten the yoke nut securely in place. 17. Apply 20 psig (138 kpa) supply air to the actuator and observe the unit for proper operation. 18. Install the position indicator scale (included with the actuator) so that the top line on the scale is aligned with the center of the anti-rotation pin. Doing so completes the mounting procedure for spring-return-up action. Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators 11

Spring-Return- Down Models (N.O. Valves Only) For spring-return-down action on N.O. valves only, proceed as follows: Actuator Stem Upper Stem Jam Nut Lower Stem Jam Nut Figure 10: Positioning the Valve Stem 9. Locate the four threaded studs on the actuator housing adjacent to the actuator stem, and install the actuator onto the yoke. 10. Secure the actuator to the yoke with the four metric nuts and washers (included with the actuator). Extend the valve stem until it engages the connector and tighten the metric nuts securely. The connector should be free to move. Anti-Rotation Pin Figure 11: Installing the Anti-Rotation Pin 11. Align the connector with the yoke slot and insert the anti-rotation pin. Tighten the anti-rotation pin securely in place. 12 Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators

12. Apply enough supply air to the actuator in order to move the actuator stem bolt down at least 1/8 in. (3 mm), then tighten the actuator stem bolt securely. Note: Do not rotate the actuator stem while tightening the actuator stem bolt; doing so may wrinkle the diaphragm, affecting actuator performance. Use the stem wrench included in the MP8000-6012 Repair Tool Kit to keep the actuator stem from turning. 13. Disconnect the supply air. Actuator Stem Upper Stem Jam Nut Lower Stem Jam Nut Figure 12: Securing the Valve Stem 14. Thread the lower stem jam nut onto the valve stem, up against the connector. Tighten the lower stem jam nut until there is a 1/32 in. gap between the actuator stop nut and the brass bearing holder (both located on the opposite side of the actuator). 15. Thread the upper stem jam nut (included with the valve) up against the connector and tighten it securely in place. 16. Tighten the yoke nut securely in place. 17. Apply 20 psig (138 kpa) supply air to the actuator and observe the unit for proper operation. 18. Install the position indicator scale (included with the actuator) so that the bottom line on the scale is aligned with the center of the anti-rotation pin. Doing so completes the mounting procedure for spring-return-down action. Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators 13

Mounting to VG7000 Series Bronze Control Valves When mounting a V-9502 Pneumatic Valve Actuator Positioner or an EPP-1000 Electro-Pneumatic Valve Actuator Positioner to an MP8000 Series Actuator, refer to the instructions included with the positioner.! CAUTION: Personal Injury Hazard. If the valve body is installed in a system, isolate the valve and bleed off the system pressure. Failure to do so may result in personal injury. To perform the basic mounting procedure for Normally Open (N.O.), Normally Closed (N.C.), and three-way mixing valves (no positioner), proceed as follows: Actuator Stop Nut Connector Metric Nuts and Washers Lock Washer Actuator Stem Bolt Yoke Figure 13: Disassembling the Yoke 1. Remove the metric nuts, washers, yoke, connector, actuator stem bolt, and lock washer from the MP8000 Actuator and retain for later use. Note: When removing the actuator stem bolt, be careful not to turn the actuator stop nut. If the stop nut is also turned, the factory calibration of the actuator will be affected. In order to hold the actuator stop nut securely in place while removing the actuator stem bolt, it may be necessary to pressurize the actuator and stroke the valve in order to gain access to the actuator stop nut. 14 Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators

Stem Down Stem Up Packing Nut Bonnet Nut Figure 14: Preparing the Valve 2. Push the valve stem down as far as it will go into the valve. 3. Remove the packing nut and retain. 4. Where applicable, remove and discard the bonnet nut. Yoke Stem Jam Nut Packing Nut Yoke Nut Figure 15: Assembling the Yoke 5. Secure the yoke to the valve bonnet using the yoke nut included with the actuator mounting kit. Position the centering boss of the yoke nut so that it faces the valve (as illustrated in Figure 15). Hand tighten only. 6. Reinstall the packing nut retained in Step 3. For brass trim valves, tighten the packing nut 1/6 of a turn past hand tight. For stainless steel trim valves, hand tighten the packing nut all the way. 7. If an MP82 or MP83 Actuator is being mounted to a 1/4 in. stem valve, thread the 1/4 in. stem jam nut (included with the actuator mounting kit) fully onto the valve stem. If an MP84 or MP85 Actuator is being mounted to a 3/8 in. stem valve, skip to Step 9. Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators 15

Stem Extender 3/8 in. Jam Nuts 1/4 in. Jam Nut Figure 16: Installing the Stem Extender 8. Thread the stem extender (included with the actuator mounting kit) fully onto the valve stem. 9. For 1/4 in. stem valves, thread the 3/8 in. stem extender jam nut (included with the actuator mounting kit) onto the stem extender until there is approximately a four-thread gap between the two jam nuts. For 3/8 in. stem valves, thread the 3/8 in. stem jam nut (included with the actuator mounting kit) fully onto the valve stem. Actuator Stop Nut Connector Anti-Rotation Pin Hole Lock Washer Actuator Stem Bolt Figure 17: Attaching the Connector (Spring-Return-Up Models) 10. For spring-return-up models, attach the connector to the actuator stop nut using the actuator stem bolt and lock washer (included with the actuator). Engage the actuator stem bolt approximately three turns into the actuator stop nut; the connector will be loose. 16 Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators

Actuator Stem Connector Anti-Rotation Pin Hole Lock Washer Actuator Stem Bolt Figure 18: Attaching the Connector (Spring-Return-Down Models) For spring-return-down models, attach the connector to the actuator stem using the actuator stem bolt and lock washer (included with the actuator). Hand tighten only. Note: The connector must be oriented so that the holes for the anti-rotation pin are closest to the valve body. Metric Nuts and Washers Threaded Studs Connector Yoke Figure 19: Attaching the Actuator to the Yoke Spring-Return- Up Models For spring-return-up action, proceed as follows: 11. Locate the four threaded studs on the actuator housing adjacent to the actuator stop nut, and install the actuator onto the yoke. Note: The valve stem should be positioned in the fully down position. 12. Secure the actuator to the yoke with the four metric nuts and washers (included with the actuator). Extend the valve stem until it engages the connector and tighten the metric nuts securely. Also hand tighten the actuator stem bolt. The connector should be free to move. Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators 17

3/8 in. Upper Jam Nut Connector 3/8 in. Lower Jam Nut Figure 20: Connecting the Actuator to the Valve 13. Fully extend the valve stem into the connector hole; the valve stem must engage the connector. Note: If necessary, the stem extender may be turned Counterclockwise (CCW) in order to engage it into the connector. Anti-Rotation Pin Connector Figure 21: Installing the Anti-Rotation Pin 14. Align the connector with the yoke slot and insert the anti-rotation pin. Tighten the anti-rotation pin securely in place. 15. For N.O. valves only, install the 3/8 in. upper jam nut onto the stem (or stem extender) and tighten both jam nuts snug against the connector. For N.C. and three-way mixing valves, skip to Step 21. 16. Apply enough supply air to the actuator in order to move the actuator stem bolt down at least 1/8 in. (3 mm), then tighten the actuator stem bolt securely. Note: Do not rotate the actuator stop nut while tightening the actuator stem bolt; doing so may change the start point of the actuator. 18 Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators

17. Tighten the yoke nut securely in place. 18. Apply 20 psig (138 kpa) supply air to the actuator and observe the unit for proper operation. 19. Install the position indicator scale (included with the actuator) so that the top line of the scale is aligned with the center of the anti-rotation pin. 20. Disconnect the supply air. This completes the mounting procedure for spring-return-up action on N.O. valves. 21. For N.C. and three-way mixing valves, thread the 3/8 in. upper jam nut (included with the actuator mounting kit) onto the valve stem (or stem extender), down against the connector. Tighten the 3/8 in. upper jam nut until there is a 1/32 in. gap between the actuator stop nut and the brass bearing holder. 22. Thread the 3/8 in. lower jam nut up against the connector and tighten it securely in place. 23. Tighten the yoke nut securely in place. 24. Apply 20 psig (138 kpa) supply air to the actuator and observe the unit for proper operation. 25. Install the position indicator scale (included with the actuator) so that the top line on the scale is aligned with the center of the anti-rotation pin. This completes the mounting procedure for spring-return-up action on N.C. and three-way mixing valves. Spring-Return- Down Models (N.O. Valves Only) For spring-return-down action on N.O. valves only, proceed as follows: Actuator Stem Connector Anti-Rotation Pin Hole Lock Washer Actuator Stem Bolt Figure 22: Positioning the Valve Stem 11. Position the valve stem in order to fully close the valve. Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators 19

Anti-Rotation Pin Figure 23: Installing the Anti-Rotation Pin 12. Align the connector with the yoke slot and insert the anti-rotation pin. Tighten the anti-rotation pin securely in place. 13. Apply enough supply air to the actuator in order to move the actuator stem bolt down at least 1/8 in. (3 mm), then tighten the actuator stem bolt securely. Note: Do not rotate the actuator stem while tightening the actuator stem bolt; doing so may wrinkle the diaphragm, affecting actuator performance. Use the stem wrench included in the MP8000-6012 Repair Tool Kit to keep the actuator stem from turning. 14. Disconnect the supply air. 3/8 in. Upper Jam Nut 3/8 in. Lower Jam Nut 1/4 in. Stem Jam Nut Figure 24: Securing the Valve Stem 20 Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators

15. Thread the 3/8 in. lower jam nut up against the connector. Tighten the 3/8 in. lower jam nut until there is a 1/32 in. gap between the actuator stop nut and the brass bearing holder (both located on the opposite side of the actuator). 16. Thread the 3/8 in. upper jam nut (included with the actuator mounting kit) up against the connector and tighten it securely in place. 17. Thread the 1/4 in. stem jam nut (located directly above the packing nut) onto the valve stem up against the stem extender and tighten securely in place. 18. Tighten the yoke nut securely in place. 19. Apply 20 psig (138 kpa) supply air to the actuator and observe the unit for proper operation. 20. Install the position indicator scale (included with the actuator) so that the bottom line on the scale is aligned with the center of the anti-rotation pin. This completes the mounting procedure for spring-return-down action on N.O. valves. Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators 21

22 Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators

Reversing the Action of the MP8000 Actuator If required, the action of the MP8000 Actuator mounted on a N.O. valve can be reversed in the field from spring-return-up to spring-return-down or vice versa. Refer to the appropriate section that follows for reversing the action of the MP8000 Actuator.! CAUTION: Personal Injury Hazard. If the valve body is installed in a system, isolate the valve and bleed off the system pressure. Failure to do so may result in personal injury. Reversing From Spring-Return- Up to Spring- Return-Down Actuator Stem Connector Anti-Rotation Pin Hole Lock Washer Actuator Stem Bolt Figure 25: Reassembly for Spring-Return-Down Action Refer to Figure 25 and proceed as follows: 1. Disassemble the actuator and yoke assembly from the valve. Note: The actuator and yoke must be disassembled from the valve in order to reverse the action of the actuator in the field. 2. Disassemble the yoke from the actuator, and retain the yoke and four metric nuts and washers for reassembly. Also remove and retain the four metric nuts and washers on the actuator housing adjacent to the actuator stem. 3. Remove the set screw from inside the actuator stem and install it into the actuator stop nut. While keeping the actuator stop nut from turning, tighten the set screw securely in place. If the stop nut is also turned, the factory calibration of the actuator will be affected. Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators 23

4. Reassemble the actuator and yoke to the valve following the spring-return-down installation procedures outlined in the Mounting Procedure section. Reversing From Spring- Return-Down to Spring-Return- Up Actuator Stop Nut Connector Anti-Rotation Pin Hole Lock Washer Actuator Stem Bolt Figure 26: Reassembly for Spring-Return-Up Action Refer to Figure 26 and proceed as follows: 1. Disassemble the actuator and yoke assembly from the valve. Note: The actuator and yoke must be disassembled from the valve in order to reverse the action of the actuator in the field. 2. Disassemble the yoke from the actuator, and retain the yoke and four metric nuts and washers for reassembly. Also remove and retain the four metric nuts and washers on the actuator housing adjacent to the actuator stop nut. 3. Remove the set screw from inside the actuator stop nut and install it into the actuator stem. While keeping the actuator stem from turning, tighten the set screw securely in place. If the stop nut is also turned, the factory calibration of the actuator will be affected. 4. Reassemble the actuator and yoke to the valve following the spring-return-up installation procedures outlined in the Mounting Procedure section. 24 Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators

MP8000 Actuator Maintenance and Repair Replacement diaphragm and seal kits are available for MP8000 Series Pneumatic Valve Actuators; refer to Table 3 for ordering information and additional details. For a replacement MP8000 Actuator, contact the nearest Johnson Controls representative. Table 3: Repair Parts (Order Separately) Description Code Number Seal Kit for All MP8000 Series Actuators MP8000-6001 Diaphragm and Seal Kit for MP8000-6325 MP82 and MP83 Series Actuators Diaphragm and Seal Kit for MP8000-6350 MP84 and MP85 Series Actuators Repair Tool Kit (Required for Diaphragm and Seal MP8000-6012* Replacement) * This kit includes a strap handle and polyester strap, stem wrench, and 7/16 in. hex tool. Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators 25

Notes 26 Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators

Notes Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators 27

Notes European Single Point of Contact: NA/SA Single Point of Contact: APAC Single Point of Contact: JOHNSON CONTROLS WESTENDHOF 3 45143 ESSEN GERMANY JOHNSON CONTROLS 507 E MICHIGAN ST MILWAUKEE WI 53202 USA JOHNSON CONTROLS C/O CONTROLS PRODUCT MANAGEMENT NO. 22 BLOCK D NEW DISTRICT WUXI JIANGSU PROVINCE 214142 CHINA Controls Group FAN 977 507 E. Michigan Street Valve and Actuator Manual P.O. Box 423 Printed in U.S.A. Milwaukee, WI 53201 www.johnsoncontrols.com 28 Actuators and Positioners Product Information MP8000 Series Pneumatic Valve Actuators