E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51



Similar documents
DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

2/2 and 3/2 Way Size 6 Seat Valves

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

3/2 Solenoid Cartridge Valve, Size 6

3/2- and 2/2-way cartridge valve type BVE

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Chapter 5: Flow Valves

Assisted lift operated 2/2-way solenoid valves Type EV250B

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Pressure reducing valve, direct operated, Type ZDR 6 D

Electro-hydraulic pressure switches type DG

Pressure relief valves Size 6

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

SOLENOID VALVES 3-4 WAY

PUMP AND MOTOR DIVISION

15/40/80CN Series Medium Pressure Filters

Electro-pneumatic control valves

Solenoid valves 2/2-way direct-operated Type EV210A

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Actuators and Sensors. Products

KDG3V-5/7/8, 10 Series

Chapter 6: Check Valves

2-way flow control valve Type 2FRM 6

Single sub-base valve

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Proportional pressure regulators VPPE

4/2-Way Pneumatic Solenoid Valve

4 Posiflow Proportional Solenoid Valves

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

Hydraulic Flow Control Valves

Directional seated valves type VP 1

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

3/2-way Mini Solenoid Valve

3/2-way Solenoid Valve, direct-acting, NC or NO

Unit 24: Applications of Pneumatics and Hydraulics

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Cable Plug acc. to DIN EN , Form A

Hydraulic Control Solutions

Variable Displacement Pump AA10VSO

For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } {175}

Proportional Pressure Reducing Valves

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Load-sensing control block in mono and sandwich plate design

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Reaction Torque Sensor

Instruction Manual Differential Pressure Transmitter

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

G1/4 Q8. Standard with biased position

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Control block EDD Modular Directional Valve

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Check Valves Valve locator

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

3 Port Solenoid Valve

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

STC 3S A Series Solenoid Valves

size size

Pressure Relief. Pressure Relief Valves. Vickers

Redundancy Module QUINT-DIODE/40

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

Turbine Flow Sensor Series VTR

servo-controlled 3-WaY vacuum solenoid valves WiTH

TX OPEN RS232/485 module

Pressure Relief Valves SPV, SPVF

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Eco130 Series. Medium Pressure Filters Max l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

Oil Pressure Regulating Valve

Fixed displacement vane pumps

BGAH Series. Medium Pressure Filters Max. 500 l/min. 25 bar. In-line solution for a straight pipeline. Applications: Contact Information:

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Data Sheet PS1B Pressure Switch

COUNTERBALANCE VALVES

Eco130 Series. Medium Pressure Filters Max l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

Transcription:

83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE CETOP 4.2-4-P05-250 optional T port SPECIFICATIONS (obtained with mineral oil with viscosity of 36 cst at 50 C in conjunction with the relative electronic control units) Maximum operating pressure: P-A-B ports T port bar bar The E4E valve is a pilot operated directional control valve with electric proportional control and mounting interface in compliance with CETOP standards. Valve opening and flow rate can be modulated continuously in proportion to the current supplied to the proportional solenoids of the pilot valve. E4E 250 see par. 5 Maximum flow (with p 10 bar P-T) l/min 50-75 - 100 Step response Hysteresis Repeatability Electrical characteristics see par. 8 % Q max < 8% % Q max < ±2% see par. 7 The valve can be controlled directly by a current control supply unit or by means of the relative electronic control units to exploit valve performance to the full (see par. 10). Valves are available in open loop versions and in three flow rate control ranges up to 100 l/min. The valves are normally supplied with internal pilot and external drain. See par. 5 for other combinations. To ensure correct valve operation, maintain a minimum control pressure of 20 bar and flow rate of 3 l/min. Ambient temperature range Fluid temperature range C C 10 +50 20 +70 HYDRAULIC SYMBOL (typical) Fluid viscosity range cst 13 380 Recommended filtration µm absolute < 25 Recommended viscosity cst 25 Mass E4E - S* E4E - TA/TC kg 8,3 7,8 83 300/100 ED 1/8

1 - IDENTIFICATION CODE E 4 E - / / 51-24 / Pilot operated directional control valve Size: CETOP P05 Electric proportional control Configurations, spool type and controlled flow rate (see table 2) Seal: omit for mineral oils V = viton for special fluids Nominal solenoid voltage 24 V DC Series No. (from 50 to 59 sizes and mounting dimensions remain unchanged) Piloting: E=external pilot (omit for internal pilot) Drain: I =internal drain (omit for external drain) 2 - CONFIGUTATIONS Valve configuration depends on the combination of the following elements: number of proportional solenoids, type of spool, controlled flow rate, number of return springs. S configuration: 2 solenoids with spring centering TA configuration: 1 solenoid on port B side with return spring in main valve TC configuration: 1 solenoid on port A side with return spring in main valve Controlled flow with N.B. Spools with differential control areas (ratio 1:2) are available on request. 83 300/100 ED 2/8

3 - CHARACTERISTIC CURVES (values measured with viscosity of 36 cst at 50 C with valves connected to the relative electronic control units) 3.1 - Flow control Typical constant flow rate control curves at p according to current supply to solenoid, measured for spool types S12 * - 12 * TA - 12 * TC. The reference p values are measured between ports P and T on the valve. SPOOL TYPE 121 SPOOL TYPE 122 SPOOL TYPE 123 83 300/100 ED 3/8

Typical flow rate control curves at constant p according to current supply to solenoid, measured for spool type S9 *. The reference p values are measured between ports P and T on the valve. SPOOL TYPE 91 SPOOL TYPE 92 SPOOL TYPE 93 83 300/100 ED 4/8

4 - HYDRAULIC FLUIDS Use mineral oil-based hydraulic fluids with anti-foam and antioxidant additives. For use with other types of fluids (water glycol, phosphate esters and others) consult our technical department. Operation with fluid temperature exceeding 70 C causes premature deterioration of the quality of the fluid and seals. The physical and chemical properties of the fluid must be maintained. 5 - PILOTING AND DRAINS E4E valves are normally supplied with internal pilot and external drain. For special plant requirements other combinations are possible; refer to the table below. VALVE TYPE Plug assembly X Y X: plug for external pilot M5x6 Y: plug for external drain M5x6 E4E - ** INTERNAL PILOT AND EXTERNAL DRAIN NO YES E4E - ** /I INTERNAL PILOT AND INTERNAL DRAIN NO NO E4E - ** /E E4E - ** /EI EXTERNAL PILOT AND EXTERNAL DRAIN EXTERNAL PILOT AND INTERNAL DRAIN YES YES YES NO T PRESSURE (bar) Pressure MIN MAX X line pilot pressure 20 250 Pressure in T line with internal drain Pressure in T line with external drain 2 200 P 83 300/100 ED 5/8

6 - OVERALL AND MOUNTING DIMENSIONS Fastening bolts: 4 bolts M6x35 Torque: 8 Nm 1 2 3 4 5 Mounting surface with sealing rings: 5 off OR type 2050-2 off OR type 2037 DIN 43650 electrical connector Connector removal space Manual emergency control Coil removal space dimensions in mm 83 300/100 ED 6/8

7 - ELECTRICAL CHARACTERISTICS Proportional solenoid The proportional solenoid comprises two parts: tube and coil. The tube, screwed to the valve body, contains the armature which is designed to maintain friction to a minimum thereby reducing hysteresis. The coil is mounted on the tube secured by means of a lock nut and can be rotated through 360 depending on installation clearances. NOMINAL VOLTAGE V DC 20 COIL RESISTANCE (at 20 C) Ω 18,5 CURRENT DUTY CYCLE nominal maximum ELECTROMAGNETIC COMPATIBILITY (EMC) - EMISSIONS EN 50081-1 - IMMUNITY EN 50082-2 A 100% 0,7 0,82 in compliance with 89/336 EEC PROTECTION TO ATMOSPHERIC AGENTS (according to IEC 144 standards) IP 65 8 - STEP RESPONSE (measured with mineral oil with viscosity of 36 cst at 50 C in conjunction with the relative electronic control units) Step response is the time taken for the valve to reach 90% of the set pressure value following a step change of reference signal. The table shows typical response times with valve flow rate of 75 l/min and p=10 bar P-T. Reference signal step E4E-S * E4E- * T * 0 100% 100% 0 25 75% 75 25% +90 90% Step response [ms] 95 60 50 50 60 9 - INSTALLATION E4E valves can be installed in any position without impairing correct operation. Ensure that there is no air in the hydraulic circuit. Valves are fixed by means of screws or tie rods on a flat surface with planarity and roughness equal to or better than those indicated in the relative symbols. If minimum values are not observed fluid can easily leak between the valve and support surface. Surface finishing 83 300/100 ED 7/8

10 - ELECTRONIC CONTROL UNITS E4E - 12 * TA (TC) EPC-111 plug version (see cat. 89 110) EPA-M111 rail DIN EN 50022 (see cat. 89 220) mounting UEIK-11 Eurocard format (see cat. 89 300) E4E - S * EPA-M211 rail DIN EN 50022 (see cat. 89 220) mounting UEIK-21 Eurocard format (see cat. 89 320) 11 - SUBPLATES (see 51 000) PME4-AI5G ports on rear PME4-AL5G side ports Port dimensions: P, T, A, B: 3/4 BSP X, Y: 1/4 BSP DUPLOMATIC OLEODINAMICA SpA 20025 LEGNANO (MI) - P.le Bozzi, 1 / Via Edison Tel. 0331/472111-472236 - Fax 0331/548328 83 300/100 ED REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS. 8/8