767-6401 4 AI U/I Analog Input Module Voltage/Current WAGO-SPEEDWAY 767. Manual. Version 3.1.0



Similar documents
WAGO Software CODESYS Library WagoLibDiagnosticIDs.lib for accessing the internal diagnostics protocol

WAGO-Software WAGO DALI Configurator. Manual. for the configuration of the DALI network and the DALI Multi-Master Module Version 2.0.

WAGO-I/O-SYSTEM 750 Bluetooth RF-Transceiver Manual. Version 2.0.0, valid from FW/HW Version 03/03

WAGO Software MODBUS Master Configurator. Manual. for Configuration of MODBUS Networks with WAGO-I/O-PRO (CODESYS) Version 1.0.0

WAGO-I/O-SYSTEM 750 KNX/EIB/TP1 Module Device Mode. Manual. Version 1.1.0

WAGO-I/O-SYSTEM 750 The WAGO KNX Concept. Manual. Version 1.1.0

Application Note. WAGO EtherNet/IP Communications with a CompactLogix PLC Using Explicit Messaging. A500620e, English Version: 1.0.

WAGO-I/O-SYSTEM 750 ETHERNET TCP/IP 2-port Controller PLC - ETHERNET TCP/IP Programmable Fieldbus Controller, 2 Ports

WagoLibConfigETH.lib CODESYS Library for Device Configuration of ETHERNET Fieldbus Controller. WAGO Software. Library Description. Version 1.0.

WAGO-I/O-SYSTEM 750 ETHERNET Controller 10 MBit PLC - ETHERNET TCP/IP Programmable Fieldbus Controller

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

DO 230V AC 1.0A/ Relay 2CO/ Potential Free 2-Channel Relay Output Module 230 VAC, 1.0 A, Isolated Outputs, 2 Changeover Contacts

MINI MCR-SL-R-UI(-SP)

WAGO-I/O-SYSTEM 750 WAGO-I/O-IPC-C / PROFIBUS DP Master, CoDeSys 2.3, Telecontrol

Modular I/O System Analog and Digital Interface Modules

WAGO-I/O-SYSTEM. Using library WagoLibMSSQL_03.lib in CoDeSys 2.3 for interface to Microsoft SQL Server 200x. Application Note

WAGO PFC 750-8xx Interface to Horner HMI Application note

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Digital input modules

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Inductive sensor NI10-M18-Y1X-H1141

Accessing EtherNet/IP Network Variables in a WAGO with a ControlLogix PLC Application note

Accessories SUNNY REMOTE CONTROL

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Technical Data. Dimensions

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

WAGO-I/O-SYSTEM 750 ETHERNET Programmable Fieldbus /100 Mbit/s; digital and analog signals. Version 1.1.0

Voltage Regulator SPAU 341 C. Product Guide

BNI IOL K006 BNI IOL K006. IO-Link Sensor-Hub analog User s Guide

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

3M Wrist Strap and Footwear Tester 740. User s Guide

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

DMX2PWM 9 Channel Dimmer Setup Manual

Redundancy Module QUINT-DIODE/40

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Mounting Instructions. Torque Transducer. A en

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Duct Humidity Transmitter

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

WAGO-I/O-SYSTEM in ABB robot control systems Application note

KNX R. Rain Sensor. Installation and Adjustment

BNI EIP Z009 IP67 Module, Unmanaged Switch

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

How To Use A Power Supply On A Powerline 2.2 (Ai)

TX OPEN RS232/485 module

A good connection. International approvals.

Threaded Resistance Thermometers Model TR10-D, Miniature Design

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

Configuration a Profibus-DP node using Step7 and WAGO-I/O components Application note

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor

Safety technique. Emergency stop module BO 5988 safemaster

Operating instructions. AS-i Profibus gateway AC1411 / AC /00 04/2014

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Installation and safety instructions for AC/DC built-in devices

User s Manual Before using the inverter, you need to read and save the safety instructions.

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Technical data sheet TDS0070

Operating Instructions Busch-Dimmer. Universal master dimmer 2251 UCGL Rev

Analog signal converters CC-E I/I Current / current isolators

SAFETY MANUAL SIL Switch Amplifier

PHOENIX CONTACT Features

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

BroadBand PowerShield. User Manual

CompactLogix Power Supplies Specifications

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Cross-beam scanning system to detect slim objects. 100 mm in

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Explosion proof enclosures

1756 ControlLogix Chassis Specifications

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

3500/62 Process Variable Monitor

Architect/Contractor Information Package

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Product and functional description

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Floodlight Range Installation Guide

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

S-series Mass Connection Solutions

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Series 8146/5-V37 and Series 8150/5-V37

LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

Variable speed drives for synchronous and asynchronous motors

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Transcription:

Pos: 2 /Dokumentation allgemein/einband/einband Handbuch - Fronts eite 2015 - mit Doc Variabl en (Standar d) @ 9\mod_1285229289866_0.docx @ 64941 @ @ 1 Pos : 3 /Alle Serien (Allgemeine M odul e)/hinweise z ur Dokumentation/Impres sum für Standardhandbüc her - allg. Angaben, Ansc hriften, Tel efonnummer n und E-Mail-Adres sen @ 3\mod_1219151118203_21.docx @ 21060 @ @ 1 WAGO-SPEEDWAY 767 767-6401 4 AI U/I Analog Input Module Voltage/Current

=== Ende der Liste für T extmar ke Ei nband_vorne === 2 WAGO-SPEEDWAY 767 2016 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik GmbH & Co. KG Hansastraße 27 D-32423 Minden Phone: +49 (0) 571/8 87 0 Fax: +49 (0) 571/8 87 1 69 E-Mail: Web: info@wago.com http://www.wago.com Technical Support Phone: +49 (0) 571/8 87 5 55 Fax: +49 (0) 571/8 87 85 55 E-Mail: support@wago.com Every conceivable measure has been taken to ensure the accuracy and completeness of this documentation. However, as errors can never be fully excluded, we always appreciate any information or suggestions for improving the documentation. E-Mail: documentation@wago.com We wish to point out that the software and hardware terms as well as the trademarks of companies used and/or mentioned in the present manual are generally protected by trademark or patent.

WAGO-SPEEDWAY 767 Table of Contents 3 Pos : 5 /D okumentati on allgemein/verzeic hnisse/inhalts verz eichnis - Ü berschrift og und Verzei chnis @ 3\mod_1219151230875_21.docx @ 21063 @ @ 1 Table of Contents 1 Notes about this Documentation... 6 1.1 Validity of these Operating Instructions... 6 1.2 Copyright... 6 1.3 Symbols... 7 1.4 Number Notation... 9 1.5 Font Conventions... 9 2 Important Notes... 10 2.1 Legal Bases... 10 2.1.1 Subject to Changes... 10 2.1.2 Personnel Qualification... 10 2.1.3 Use in Compliance with Underlying Provisions... 11 2.1.4 Technical Condition of Specified Devices... 11 2.2 Safety Advice (Precautions)... 12 2.3 Safety Equipment... 13 2.4 Notes on Operation... 14 3 Device Description... 15 3.1 Connectors... 16 3.2 Marking Possibilities and Fastening... 17 3.3 Display Elements... 18 3.4 Labeling... 19 3.5 Schematic Diagram... 21 3.6 Dimensions... 22 3.7 Technical Data... 23 3.7.1 General Information... 23 3.7.2 Supply... 23 3.7.3 Communication... 23 3.7.4 Inputs... 24 3.7.5 Analog Value Creation... 24 3.7.6 Failures and Errors... 24 3.7.7 Configurable Functions... 24 3.7.8 Diagnostics... 25 3.7.9 Process Image... 25 3.7.10 Display Elements... 25 3.7.11 Isolation... 25 3.8 Approvals... 26 3.9 Standards and Guidelines... 27 4 Mounting... 28 4.1 Information on Mounting... 28 4.2 Tools and Accessories Required for Mounting... 30 4.3 Direct Mounting on Your System... 31 4.4 Mounting on a Carrier Rail (only with WAGO Accessories)... 32 4.4.1 Fastening the Carrier Rail Adapter to the Module... 32 4.4.2 Fastening the Module with Carrier Rail Adapter to a Carrier Rail... 33 4.5 Mounting on a Profile Rail (only with WAGO Accessories)... 34 4.5.1 Fastening the Profile Adapter to the Module... 34

4 Table of Contents WAGO-SPEEDWAY 767 4.5.2 Fastening the Module with Profile Adapter to a Profile Rail... 35 4.6 Marking and Replacing the Marking Spaces... 36 4.7 Mounting the Spacer in the Case of Compact Arrangement... 37 5 Connecting Data and Supply Cables... 39 5.1 Notes... 39 5.2 Required Accessories... 40 5.3 Connecting the S-BUS Cables... 41 5.4 Connecting the Supply Cable... 43 5.5 Connecting the Sensor Cable... 45 6 Commissioning... 47 7 Parameterizing... 48 7.1 Electronic Type Label... 50 7.2 Diagnostic Overview... 51 7.3 Analog Inputs... 53 7.4 User-defined Measuring Ranges 1 4... 55 7.5 Global Settings... 56 7.6 Parameters of Field Supply... 56 7.7 Automatic Storage of System Parameters... 57 7.8 Updating the Firmware... 57 8 Process Image... 58 8.1 Input Data... 59 8.2 Output Data... 62 9 Diagnostics... 64 9.1 LED Signaling... 64 10 Service... 67 10.1 Updating the Firmware... 67 10.2 Replacing the Module... 67 10.2.1 Disconnecting the Cables... 67 10.2.2 Removing the Module from Your System... 68 10.2.3 Removing the Module from the Carrier Rail... 68 10.2.4 Removing the Module from the Profile Adapter... 69 10.2.5 Connecting the Module... 69 10.3 Disposal... 69 11 Use in Hazardous Environments... 70 11.1 Marking Configuration Examples... 71 11.1.1 Marking for Europe According to ATEX and IEC-Ex... 71 11.2 Installation Regulations... 72 11.2.1 Special Conditions for Safe Use (ATEX Certificate BVS 15 ATEX E098X)... 73 11.2.2 Special Conditions for Safe Use (IEC Ex Certificate IECEx BVS 15.0083X)... 74 12 Appendix... 75 12.1 Process Values of the Module... 75 12.2 Diagnostic Information... 78 List of Figures... 79

=== Ende der Liste für T extmar ke Verzeic hnis_vor ne === WAGO-SPEEDWAY 767 Table of Contents 5 List of Tables... 80

Pos : 9 /Seri e 767 ( WAGO- SPEED WAY) /Wic htige Erl äuter ung en/sic her hei tshi nweis e/warnung/warnung: R eleas e N otes beac hten @ 8\mod_1278912368761_21.docx @ 59530 @ @ 1 Pos : 10 /Serie 767 ( WAGO-SPEED WAY)/Wic htige Erläuterungen/Sicherheits hinweis e/achtung/achtung: Vers orgungsausleg ung @ 8\mod_1278912433448_21.docx @ 59533 @ @ 1 Pos : 11 /All e Seri en (Allgemei ne Module)/Hi nweis e zur Dokumentation/Hinweise/Hinweis: Dokumentation aufbewahren @ 4\mod_1237987339812_21.docx @ 29026 @ @ 1 Pos: 13.2 /Dokumentation allgemein/gliederungselemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 6 Notes about this Documentation WAGO-SPEEDWAY 767 Pos : 7 /Alle Serien (Allgemeine M odul e)/übersc hriften für all e Serien/Hi nweis e zur D okumentati on/hinweise z u dies er D okumentation - Ü berschrift 1 @ 4\mod_1237987661750_21.docx @ 29029 @ 1 @ 1 1 Notes about this Documentation Pos : 8 /Seri e 767 ( WAGO- SPEED WAY) /Hinweise zur Dokumentati on/hinweis e z ur D okumentation I/O-M odul e 767- xxxx @ 5\mod_1248172015859_21.docx @ 38666 @ @ 1 The module shall only be installed and operated in conjunction with these operating instructions and the system description. Observe release notes! Please note that, within the SPEEDWAY system, a function is provided without restriction only if all system's components have the same system-wide firmware release. Therefore, always observe the appropriate release notes on products used. Supply layout! In addition to these operating instructions, you will need the WAGO SPEEDWAY 767, System Description and Information manual, which can be downloaded at www.wago.com. There you will find information regarding supply layout, etc. Always retain this documentation! This documentation is part of the product. Therefore, retain the documentation during the entire service life of the product. Pass on the documentation to any subsequent user. In addition, ensure that any supplement to this documentation is included, if necessary. Pos : 12 /Serie 767 ( WAGO-SPEEDWAY)/Hinweise zur Dokumentation/Gültigkeit Dokumentation I/O-Modul 767- xxxx @ 5\mod_1248172494859_21.docx @ 38679 @ 2 @ 1 1.1 Validity of these Operating Instructions These operating instructions are only applicable to the WAGO SPEEDWAY 767 Series module 4 AI U/I, 767-6401. Pos : 13.1 /All e Seri en ( Allgemei ne Module)/Hi nweis e zur D okumentati on/urhebersc hutz ausführlich @ 4\mod_1235565145234_21.docx @ 27691 @ 2 @ 1 1.2 Copyright This, including all figures and illustrations, is copyright-protected. Any further use of this by third parties that violate pertinent copyright provisions is prohibited. Reproduction, translation, electronic and phototechnical filing/archiving (e.g., photocopying) as well as any amendments require the written consent of WAGO Kontakttechnik GmbH & Co. KG, Minden, Germany. Non-observance will involve the right to assert damage claims.

Pos : 13.4.1 /All e Serien ( Allgemei ne Module)/Wic htige Erläuterungen/Sicherheits- und sons tige Hinweis e/gefahr/gefahr: _War nung vor Personenschäden allgemein_ - Erl äuter ung @ 13\mod_1343309450020_21.docx @ 101029 @ @ 1 Pos : 13.4.2 /All e Serien ( Allgemei ne Module)/Wic htige Erläuterungen/Sicherheits- und sons tige Hinweis e/gefahr/gefahr: _War nung vor Personenschäden durc h elektrisc hen Strom_ - Erläuterung @ 13\mod_1343309694914_21.docx @ 101030 @ @ 1 Pos : 13.4.3 /All e Serien ( Allgemei ne Module)/Wic htige Erläuterungen/Sicherheits- und sons tige Hinweis e/warnung/warnung: _Warnung vor Personensc häden allgemei n_ - Erläuterung @ 13\mod_1343309877041_21.docx @ 101035 @ @ 1 Pos : 13.4.4 /All e Serien ( Allgemei ne Module)/Wic htige Erläuterungen/Sicherheits- und sons tige Hinweis e/vorsic ht/vorsicht: _War nung vor Pers onensc häden allgemein_ - Erläuterung @ 13\mod_1343310028762_21.docx @ 101038 @ @ 1 Pos : 13.4.5 /All e Serien ( Allgemei ne Module)/Wic htige Erläuterungen/Sicherheits- und sonstige Hinweise/Achtung/Achtung: _Warnung vor Sachschäden allgemein_ - Erläuterung @ 13\mod_1343310134623_21.docx @ 101041 @ @ 1 Pos : 13.4.6 /All e Serien ( Allgemei ne Module)/Wic htige Erläuterungen/Sicherheits- und sonstige Hinweise/Achtung/Achtung: _Warnung vor Sachschäden durch elektrostatische Aufladung_ - Erläuterung @ 13\mod_1343310227702_21.docx @ 101044 @ @ 1 Pos : 13.4.7 /All e Serien ( Allgemei ne Module)/Wic htige Erläuterungen/Sicherheits- und sonstige Hinweise/Hi nweis/hinweis: _Wichtiger Hi nweis allgemein_ - Erläuterung @ 13\mod_1343310326906_21.docx @ 101047 @ @ 1 Pos : 13.4.8 /All e Serien ( Allgemei ne Module)/Wic htige Erläuterungen/Sicherheits- und sons tige Hinweis e/infor mation/infor mation: _Weiter e Infor mation allgemei n_ - Erl äuter ung @ 13\mod_1343310439814_21.docx @ 101051 @ @ 1 WAGO-SPEEDWAY 767 Notes about this Documentation 7 Pos : 13.3 /All e Seri en ( Allgemei ne Module)/Ü bers chriften für alle Serien/Hinweis e z ur Dokumentation/Symbol e - Ü bersc hrift 2 @ 13\mod_1351068042408_21.docx @ 105270 @ 2 @ 1 1.3 Symbols Personal Injury! Indicates a high-risk, imminently hazardous situation which, if not avoided, will result in death or serious injury. Personal Injury Caused by Electric Current! Indicates a high-risk, imminently hazardous situation which, if not avoided, will result in death or serious injury. Personal Injury! Indicates a moderate-risk, potentially hazardous situation which, if not avoided, could result in death or serious injury. Personal Injury! Indicates a low-risk, potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Damage to Property! Indicates a potentially hazardous situation which, if not avoided, may result in damage to property. Damage to Property Caused by Electrostatic Discharge (ESD)! Indicates a potentially hazardous situation which, if not avoided, may result in damage to property. Important Note! Indicates a potential malfunction which, if not avoided, however, will not result in damage to property.

Pos: 13.5 /Dokumentation allgemein/gliederungselemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 8 Notes about this Documentation WAGO-SPEEDWAY 767 Additional Information: Refers to additional information which is not an integral part of this documentation (e.g., the Internet).

Pos : 14 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Notes about this Documentation 9 Pos : 13.6 /All e Seri en ( Allgemei ne Module)/Hi nweis e zur D okumentati on/dars tellung der Zahlens ys teme - Ü berschrift 2 und Inhal t @ 3\mod_1221059454015_21.docx @ 21711 @ 2 @ 1 1.4 Number Notation Table 1: Number Notation Number Code Example Note Decimal 100 Normal notation Hexadecimal 0x64 C notation Binary '100' '0110.0100' In quotation marks, nibble separated with dots (.) Pos : 13.7 /All e Seri en ( Allgemei ne Module)/Hi nweis e zur D okumentati on/sc hriftkonventi onen - Ü bers chrift 2 und Inhalt @ 3\mod_1221059521437_21.docx @ 21714 @ 2 @ 1 1.5 Font Conventions Table 2: Font Conventions Font Type Indicates italic Names of paths and data files are marked in italic-type. e.g.: C:\Program Files\WAGO Software Menu Menu items are marked in bold letters. e.g.: Save > A greater-than sign between two names means the selection of a menu item from a menu. e.g.: File > New Input Designation of input or optional fields are marked in bold letters, e.g.: Start of measurement range Value Input or selective values are marked in inverted commas. e.g.: Enter the value 4 ma under Start of measurement range. [Button] Pushbuttons in dialog boxes are marked with bold letters in square brackets. e.g.: [Input] [Key] Keys are marked with bold letters in square brackets. e.g.: [F5]

Pos: 16.5 /Dokumentation allgemein/gliederungselemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 10 Important Notes WAGO-SPEEDWAY 767 Pos : 15 /All e Seri en (Allgemei ne Module)/Ü berschriften für alle Serien/Wichtige Erläuterungen/Wichtige Erläuterungen - Übersc hrift 1 @ 4\mod_1241428899156_21.docx @ 32170 @ 1 @ 1 2 Important Notes Pos : 16.1 /All e Seri en ( Allgemei ne Dokumente) ( Allgemei ne Module)/Wic htige Erläuterungen/Wic htige Erläuterungen - Einl eitung @ 3\mod_1221059818031_21.docx @ 21717 @ @ 1 This section includes an overall summary of the most important safety requirements and notes that are mentioned in each individual section. To protect your health and prevent damage to devices as well, it is imperative to read and carefully follow the safety guidelines. Pos : 16.2 /All e Seri en ( Allgemei ne Module)/Ü bers chriften für alle Serien/Wichtige Erläuter ungenr ec htlic he Gr undlag en - Übersc hrift 2 @ 3\mod_1221060626343_21.docx @ 21726 @ 2 @ 1 2.1 Legal Bases Pos : 16.3 /All e Seri en (Allgemeine Dokumente) (Allgemeine Module)/Wichtige Erläuterungen/Änderungsvorbehalt - Ü bers chrift 3 und Inhalt @ 3\mod_1221060036484_21.docx @ 21720 @ 3 @ 1 2.1.1 Subject to Changes WAGO Kontakttechnik GmbH & Co. KG reserves the right to provide for any alterations or modifications that serve to increase the efficiency of technical progress. WAGO Kontakttechnik GmbH & Co. KG owns all rights arising from the granting of patents or from the legal protection of utility patents. Third-party products are always mentioned without any reference to patent rights. Thus, the existence of such rights cannot be excluded. Pos: 16.4 /Serie 767 (WAGO-SPEED WAY)/Wic htige Erläuterungen/I/O-M odul/pers onalqualifi kation 767- xxxx @ 5\mod_1248175871265_21.docx @ 38705 @ 3 @ 1 2.1.2 Personnel Qualification All sequences implemented on the module may only be carried out by electrical specialists with sufficient knowledge in automation. The specialists must be familiar with the current standards and guidelines for the module and automation environment.

Pos: 16.6 /Serie 767 (WAGO-SPEED WAY)/Wic htige Erläuterungen/I/O-M odul/bes timmungsgemäß e Verwendung 767-6401 @ 5\mod_1248176466312_21.doc x @ 38731 @ 3 @ 1 Pos : 16.11 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Important Notes 11 2.1.3 Use in Compliance with Underlying Provisions The module 767-6401 is used to capture voltage signals and current signals that are relayed to a higher-level controller (e.g., a programmable fieldbus coupler). Pos: 16.7 /Serie 767 (WAGO-SPEED WAY)/Wic htige Erläuterungen/I/O-M odul/bes timmungsgemäß e Verwendung 767-IOs allgemein1 @ 7\mod_1266322273828_21.docx @ 50731 @ @ 1 The module may not be used to control safety-related functions, i.e. it cannot be a functional part of a safety function. Pos: 16.8 /Serie 767 (WAGO-SPEED WAY)/Wic htige Erläuterungen/I/O-M odul/bes timmungsgemäß e Verwendung 767-IOs allgemein2 @ 5\mod_1248176511796_21.docx @ 38751 @ @ 1 The module may only be operated in combination with components of the WAGO SPEEDWAY 767 Series. The module was developed for applications requiring IP 67 (NEMA type 6, 6P) protection. Pos: 16.9 /Serie 767 (WAGO-SPEED WAY)/Wic htige Erläuterungen/I/O-M odul/bes timmungsgemäß e Verwendung 767- xxxx allgemei n3 @ 8\mod_1278997190572_21.docx @ 59680 @ @ 1 Applications other than those described in this manual are not permitted. Pos : 16.10 /Alle Serien (Allgemeine D okumente) (Allgemeine M odul e)/wichtige Erläuterungen/T echnisc her Zus tand der Ger äte - Ü bers chrift 3 und Inhalt @ 3\mod_1221060446109_21.docx @ 21723 @ 3 @ 1 2.1.4 Technical Condition of Specified Devices The devices to be supplied ex works are equipped with hardware and software configurations, which meet the individual application requirements. WAGO Kontakttechnik GmbH & Co. KG will be exempted from any liability in case of changes in hardware or software as well as to non-compliant usage of devices. Please send your request for modified and new hardware or software configurations directly to WAGO Kontakttechnik GmbH & Co. KG.

Pos : 16.13 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/sic herheits hinweise/gefahr/gefahr: El ektrisc he Spannung @ 8\mod_1278307980373_21.docx @ 58901 @ @ 1 Pos : 16.14 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/sic herheits hinweise/vorsicht/vorsic ht: Heiß e Ansc hluss buchsen @ 8\mod_1278308217203_21.docx @ 58913 @ @ 1 Pos : 16.15 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/sic herheits hinweise/ac htung/ac htung: Höchs te Strombel astbar keit der Vers orgungskontakte @ 8\mod_1278308653219_21.docx @ 58916 @ @ 1 Pos : 16.16 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/sic herheits hinweise/ac htung/ac htung: Offene Ans chl üss e @ 8\mod_1278308159953_21.docx @ 58910 @ @ 1 12 Important Notes WAGO-SPEEDWAY 767 Pos : 16.12 /Alle Serien (Allgemeine M odul e)/übersc hriften für all e Seri en/wic htige Erl äuter ungensicherheits hinweis e - Ü bers chrift 2 @ 6\mod_1260180299987_21.docx @ 46724 @ 2 @ 1 2.2 Safety Advice (Precautions) Electric voltage! Operate the 767 Series components exclusively with 24 VDC PELV (Protective Extra Low Voltage) or SELV (Safety Extra Low Voltage) voltage sources. Failure to comply may result in electric shock. Hot connection sockets! Even when taking into account derating, high surface temperatures on the metallic connection sockets and on the enclosure can arise during operation. If the 767 Series component has been in operation, allow it to cool off before moving it. The highest current carrying capacity of the supply contacts is 4 A! Always observe the maximum current carrying capacity per supply line (U LS, U A ) for each 767 Series component and the overall power consumption for all 767 components. Neither of these values shall exceed 4 A since an increase in current causes the contacts to overheat and damages the 767 Series components. Information regarding the power demand of each 767 Series component can be found in the corresponding data sheet, which is available from www.wago.com. Exposed connections! If connections have not been closed with protective caps, liquid or dirt can penetrate the components of the 767 Series module and ruin it. Therefore, close all unnecessary connections with protective caps, which must be ordered separately, in order to maintain the IP67 degree of protection. (See section Accessories of the fieldbus coupler/controller manual.) Pos : 16.17 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/i/o-modul /Sic her hei tshi nweise 767- xxxx_2 @ 7\mod_1267623532771_21.docx @ 51669 @ @ 1 Disconnect the power supply from the system on which you wish to mount the 767 Series device. Observe the appropriate accident prevention regulations for your system during assembly, start-up, maintenance, and repairs. For example, BGV A3, Electrical systems and equipment. The operating instructions for the 767 Series module and the system description must be laid out ready on site. Observe the exact positioning (coding) between plug and socket. The 767 Series device shall not come into contact with substances having seeping and insulating properties. Otherwise, additional measures shall be

Pos : 16.21 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Important Notes 13 taken for the device, such as installation of an enclosure that is resistant to the above-mentioned substance properties. Electronic components fulfilling the ESD requirements according to the IEC 61000-6-2 are integrated in the 767 device. As higher voltages may occur, under unfavorable circumstances, due to electrical charge in the field, discharge must be ensured before performing work on the 767 system. Ensure that the potential equalization is correctly laid out. Pos : 16.18 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/i/o-modul /Sic her hei tshi nweise 767- xxxx_3 @ 7\mod_1267624103126_21.docx @ 51676 @ @ 1 Keep all cables a sufficient distance away from electromagnetic sources of interference in order to maintain a high level of interference resistance of the 767 system against electromagnetic emissions. Use only shielded cables at the necessary locations, and always observe the appropriate standards for EMC-suitable installations. For the power supply and for the S-BUS, use only pre-assembled WAGO system cables, so the specified characteristics of the technical data can be achieved. Pos : 16.19 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/i/o-modul /Sic her hei tshi nweise 767- xxxx_4 @ 7\mod_1267623157545_21.docx @ 51662 @ @ 1 Replace defective or damaged modules (e.g., deformed connections), else function disruptions can occur in the respective fieldbus stations or nodes. When laying any cables, make sure that you do not lay them within the shear range of movable machine parts. For each activity, observe the corresponding personnel qualification in the corresponding section. Observe the marking on the front and rear side of the module. Pos : 16.20 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/i/o-modul /Sic her hei tsei nrichtungen 767- xxxx @ 7\mod_1268142379773_21.docx @ 52055 @ 2 @ 1 2.3 Safety Equipment All 767 Series products are designed to meet the requirements of IP67. This includes complete protection against accidental contact with electrical voltage and currents even when wet.

Pos : 16.24 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/i/o-modul /Hinweise z um Betri eb 767- xxxx, Teil 3 @ 7\mod_1266921848140_21.docx @ 51222 @ @ 1 Pos : 17 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 14 Important Notes WAGO-SPEEDWAY 767 Pos : 16.22 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/i/o-modul /Hinweise z um Betri eb 767- xxxx, Teil 1 @ 7\mod_1266921815843_21.docx @ 51219 @ 2 @ 1 2.4 Notes on Operation When integrating the 767 module in your machine or system, all the currently applicable norms, regulations and guidelines shall be observed during all activities: for example, BGV A3, Electrical systems and equipment, DIN EN 418, EN 60204. The emergency stop equipment shall remain effective in all operating modes of the system and machine. For protection from electromagnetic interferences Connect your system to protective earth (PE), and Pos : 16.23 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/i/o-modul /Hinweise z um Betri eb 767-I/O, T eil 2 @ 5\mod_1248180225875_21.docx @ 38755 @ @ 1 Ensure that the cable routing and the installation of the fieldbus cable, S- BUS cable, supply cable, and sensor or actuator cable are correct. The following elements for 24 V supply shall be present: Outer lightning protection on buildings Inner lightning protection of supply lines and signal lines Safe electrical separation of low voltage 24 VDC through PELV (Protective Extra Low Voltage) or SELV (Safety Extra Low Voltage) voltage sources

Pos: 18.3 /Dokumentation allgemein/gliederungselemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Device Description 15 Pos : 18.1 /All e Seri en ( Allgemei ne Module)/Ü bers chriften für alle Serien/Gerätebesc hreibung/gerätebeschr eibung - Übersc hrift 1 @ 3\mod_1233756084656_21.docx @ 27096 @ 1 @ 1 3 Device Description Pos: 18.2 /Serie 767 (WAGO-SPEED WAY)/Ger ätebesc hrei bung/i/o-module/gerätebes chr eibung 767-6401 @ 5\mod_1248412362171_21.docx @ 38978 @ @ 1 The module 767-6401 is used to capture voltage and current signals. The module has many parameterization options that can be carried out via a fieldbus coupler. In addition, diagnostic messages for individual channels and for the entire module can be parameterized. It is protected against overload and can detect load errors. The actuator supply and the logic and sensor supply are monitored for undervoltage. Overview of measuring ranges of the module: Measuring ranges for current 0 ma 20 ma, 0 ma 22 ma, 4 ma 20 ma, -20 ma 20 ma Measuring ranges for voltage 0 V 10 V, -10 V 10 V Use a fieldbus or FDT-DTM as, for example, with the WAGOframe to make module settings. Detailed information about assignment of module parameters using a fieldbus can be found in the corresponding manual. Detailed information regarding the properties of the module is available in Section "Technical Data".

Pos: 18.5 /Serie 767 (WAGO-SPEED WAY)/Ger ätebesc hrei bung/ansc hl üss e/i/o-module/ansc hlüss e 767- xxxx 4xM12-Vers orgungsausg ang - Bild @ 5\mod_1248847867062_21.docx @ 39135 @ @ 1 Pos: 18.9 /Dokumentation allgemein/gliederungselemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 16 Device Description WAGO-SPEEDWAY 767 Pos : 18.4 /All e Seri en ( Allgemei ne Module)/Ü bers chriften für alle Serien/Gerätebesc hreibung/ansc hlüs se - Übersc hrift 2 @ 4\mod_1240984262656_21.docx @ 31961 @ 2 @ 1 3.1 Connectors 1 2 3 3 4 5 Figure 1: Connectors Pos: 18.6 /Serie 767 (WAGO-SPEED WAY)/Ger ätebesc hrei bung/ansc hl üss e/i/o-module/legende Anschl uss 767- xxxx S-BU S @ 5\mod_1248847875187_21.docx @ 39167 @ @ 1 Table 3: Legend for figure "Connectors" Pos: 18.7 /Serie 767 (WAGO-SPEED WAY)/Ger ätebesc hrei bung/ansc hl üss e/i/o-module/legende Anschl uss 767-6xxx AI 4xM12 @ 5\mod_1248847871890_21.docx @ 39143 @ @ 1 Position Description Function 1 S-BUS input M12 plug, B-coded For transmitting data from previous 767 Series components. 2 S-BUS output M12 socket, B-coded For transmitting S-BUS data to the next 767 Series components or to the S-BUS terminator. 3 Analog inputs X1 X4 M12 socket, A-coded For connecting analog sensors. Pos: 18.8 /Serie 767 (WAGO-SPEED WAY)/Ger ätebesc hrei bung/ansc hl üss e/i/o-module/legende Anschl uss 767- xxxx Versorgung, nicht 4803 und 4804 @ 5\mod_1248847875765_21.docx @ 39171 @ @ 1 4 Supply output M12 socket, A-coded 5 Supply input M12 plug, A-coded To use the Logic-/Sensorsupply and/or actuator supply for the following I/O modules. For feeding in both U LS (logic and sensor supply) and U A (actuator supply).

Pos : 18.12 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Device Description 17 Pos : 18.10 /Serie 767 ( WAGO-SPEEDWAY)/Gerätebeschreibung/Befestigung/I/O-Module/Beschriftung und Befestigung 767-xxxx_4xM 12 - Bild @ 5\mod_1248845067328_21.docx @ 39110 @ 2 @ 1 3.2 Marking Possibilities and Fastening 10 11 12 11 Figure 2: Marking possibilities and fastening (exemplary) Pos : 18.11 /Serie 767 ( WAGO-SPEEDWAY)/Gerätebeschreibung/Befestigung/I/O-Module/Legende z u Beschriftung und Befes tigung 767- xxxx @ 5\mod_1249475777546_21.docx @ 40514 @ @ 1 Table 4: Legend for figure "Marking possibilities and fastening" Position Description Function 10 Module marker card For identifying the module within a fieldbus node. 11 Mounting holes With integrated function earth (FE) socket for fastening and grounding the module. 12 Marker strips For identifying inputs.

Pos : 18.14 /Serie 767 ( WAGO-SPEED WAY)/Gerätebeschr eibung/anz eigeel emente/i/o-m odul e/anz eigeelemente 767- xxxx_io_4xm12 - Bild @ 5\mod_1248851030140_21.docx @ 39179 @ @ 1 Pos : 18.18 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 18 Device Description WAGO-SPEEDWAY 767 Pos : 18.13 /Alle Serien (Allgemeine M odul e)/übersc hriften für all e Seri en/gerätebes chr eibung/anzeigeel emente - Ü bersc hrift 2 @ 4\mod_1240984390875_21.docx @ 31964 @ 2 @ 1 3.3 Display Elements 15 16 17 17 19 18 Figure 3: Display elements (exemplary) Pos : 18.15 /Serie 767 ( WAGO-SPEED WAY)/Gerätebeschr eibung/anz eigeel emente/i/o-m odul e/legende zu Anz eigeel emente 767- xxxx, Pos. 15+16: Status SB und F @ 5\mod_1248854485718_21.docx @ 39190 @ @ 1 Pos : 18.16 /Serie 767 ( WAGO-SPEED WAY)/Gerätebeschr eibung/anz eigeel emente/i/o-m odul e/legende zu Anz eigeel emente 767-64xx, Pos. 17: Status AI @ 5\mod_1248855873328_21.docx @ 39208 @ @ 1 Pos : 18.17 /Serie 767 ( WAGO-SPEED WAY)/Gerätebeschr eibung/anz eigeel emente/i/o-m odul e/legende zu Anz eigeel emente 767- xxxx, Pos. 18+19: Status U A und ULS @ 7\mod_1268053208570_21.docx @ 51957 @ @ 1 Table 5: Legend for figure "Display elements" Position LED Color Meaning 15 SB Green/red/orange S-BUS status 16 F Red Diagnostic information 17 Ch1 Ch4 Yellow Indication of input status Er1 Er4 Red Indication of input error 18 U A Green Actuator supply is present. 19 U LS Green Logic supply and sensor supply are present. Detailed information Detailed information can be found in section "Diagnostics" > "LED Signaling".

Pos : 18.19.2 /Serie 767 ( WAGO-SPEEDWAY)/Gerätebeschr eibung/bedr uc kung/i/o-m odul e/bedruc kung 767-6401 - Bild @ 5\mod_1248860320359_21.docx @ 39345 @ @ 1 Pos : 18.19.4 /D okumentati on allgemein/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Device Description 19 Pos : 18.19.1 /Alle Serien (Allgemeine M odul e)/übersc hriften für all e Serien/Gerätebesc hr eibungbedruc kung - Übersc hrift 2 @ 4\mod_1241082409515_21.docx @ 32035 @ 2 @ 1 3.4 Labeling 30 37 36 31 32 33 34 35 Figure 4: Labeling Pos : 18.19.3 /Serie 767 ( WAGO-SPEEDWAY)/Gerätebeschr eibung/bedr uc kung/i/o-m odul e/legende zur Bedr uc kung 767- xxxx DI, AI @ 5\mod_1248857878390_21.docx @ 39285 @ @ 1 Table 6: Legend for figure "Labeling" Position Description 30 Manufacturer's mailing address 31 Connection assignment of S-BUS 32 Connection assignment of inputs 33 Connection example 34 Connection assignment of supply input and output 35 Information on approvals and CE marks 36 Unambiguous identification of module 37 Item number

Pos : 18.19.6 /Serie 767 ( WAGO-SPEEDWAY)/Gerätebeschr eibung/bedr uc kung/i/o-m odul e/bedruc kung sei tlich - Bild @ 5\mod_1248864035578_21.docx @ 39357 @ @ 1 Pos : 18.21 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 20 Device Description WAGO-SPEEDWAY 767 Pos : 18.19.5 /Serie 767 ( WAGO-SPEEDWAY)/Gerätebeschr eibung/bedr uc kung/i/o-m odul e/bedruc kung sei tlich @ 7\mod_1267620827007_21.docx @ 51647 @ @ 1 On the side of the module is a label, with information that would prove useful in the case of a complaint: BA: Work order number (40) SN: Serial number (40) Manufacturing number (41) 40 Figure 5: Label on the module 41 Pos : 18.20 /Serie 767 ( WAGO-SPEED WAY)/Gerätebeschr eibung/bedr uc kung/i/o-m odul e/bedruc kung sei tlich - Legende @ 9\mod_1286969974465_21.docx @ 65601 @ @ 1 Table 7: Description of manufacturing number Abbreviation Description WW Week of production JJ Year of production FW HW FL h1h2h3 Firmware release index When updating the firmware, please note that, the firmware release index may not be conformed to the printed firmware release index on the side of the fieldbus coupler. The Electronic Type Label (see section Electronic Type Label ) shows the actual firmware release index. Hardware release index Firmware loader release index Internal manufacturer information

Pos : 18.24 /Serie 767 ( WAGO-SPEED WAY)/Gerätebeschr eibung/sc hematis che Sc haltbilder/i/o-module/schematisches Schal tbil d 767-6401 @ 10\mod_1306758372759_21.docx @ 73363 @ @ 1 Pos : 18.25 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Device Description 21 Pos : 18.22 /Alle Serien (Allgemeine M odul e)/übersc hriften für all e Seri en/gerätebes chr eibung/sc hematisc hes Schaltbild - Übersc hrift 2 @ 4\mod_1240984441312_21.docx @ 31967 @ 2 @ 1 3.5 Schematic Diagram Pos : 18.23 /Serie 767 ( WAGO-SPEED WAY)/Gerätebeschr eibung/sc hematis che Sc haltbilder/i/o-m odule/ei nleitung zum sc hematisc hen Sc haltbil d 767-6xxx AI @ 10\mod_1306764200948_21.docx @ 73460 @ @ 1 The following schematic diagram provides an overview of the power supply and principle of operation of the power supply connections, as well as the analog inputs of the modules (see also sections "Connecting Data and Supply Cables" > "Connecting the Supply Cable" and "Connecting the Sensor Cable"). Analog input M12 Supply input M12 A/D Logic Ch LED 1 4 Error (Er LED) 1 4 Functional earth (FE) Figure 6: Schematic diagram

Pos : 18.27 /Serie 767 ( WAGO-SPEEDWAY)/Gerätebeschreibung/Abmessungen/I/O-Module/Abmessungen 767- xxxx_io_4xm 12 - Bild @ 5\mod_1248873304828_21.docx @ 39496 @ @ 1 Pos : 18.28 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 22 Device Description WAGO-SPEEDWAY 767 Pos : 18.26 /Alle Serien (Allgemeine M odul e)/übersc hriften für all e Seri en/gerätebes chr eibung/abmess ungen - Ü bersc hrift 2 @ 5\mod_1248869612468_21.docx @ 39441 @ 2 @ 1 3.6 Dimensions Figure 7: Dimensions of the module in millimeters (exemplary)

Pos : 18.30 /Alle Serien (Allgemeine M odul e)/wichtige Erläuterungen/Sic herheits- und sonstige Hinweise/Hinweis/Hinweis: Abweichende technische Daten bei Ver wendung i m Ex- Bereic h beac hten! @ 22\mod_1425551402429_21.docx @ 176938 @ @ 1 WAGO-SPEEDWAY 767 Device Description 23 Pos : 18.29 /Alle Serien (Allgemeine M odul e)/übersc hriften für all e Seri en/gerätebes chr eibung/t ec hnis che D aten - Ü bersc hrift 2 @ 3\mod_1232967587687_21.docx @ 26924 @ 2 @ 1 3.7 Technical Data Different technical data for applications in hazardous areas! If the device is used in an application in the hazardous area, the technical data contained in the ATEX/IECEx certificate are binding in this application! Pos : 18.31 /Serie 767 ( WAGO-SPEED WAY)/Gerätebeschr eibung/tec hnisc he Daten/I/O-Module/Gerätedaten_1_8xM8/4xM12 @ 7\mod_1265956726562_21.docx @ 50444 @ 3 @ 1 3.7.1 General Information Table 8: Technical data General information Width Height Lowness Pos : 18.32 /Serie 767 ( WAGO-SPEED WAY)/Gerätebeschr eibung/tec hnisc he Daten/I/O-Module/Gerätedaten_2_64xx @ 16\mod_1375795678262_21.docx @ 128084 @ @ 1 Weight Pos : 18.33 /Serie 767 ( WAGO-SPEED WAY)/Gerätebeschr eibung/tec hnisc he Daten/I/O-M odule/anal ogei ngangsmodul e/t ec hnisc he D aten 767-6401 @ 5\mod_1248946013625_21.docx @ 39544 @ 333333333 @ 1 3.7.2 Supply 50 mm 35.7 mm 117 mm Approx. 262 g Table 9: Technical data Supply Connection type M12 connectors, A-coded, 4 poles * Current carrying capacity of the Maximum 8 A (U LS : 4 A, U A : 4 A) supply connections Supply voltage Logic and sensor voltage U LS ** Actuator voltage U A Supply current Logic and sensor current I LS Actuator current I A Protection * Derating must be observed ** Also required for supply transmission 3.7.3 Communication DC 24 V (-25 % +30 %) DC 24 V (-25 % +30 %) Typically 50 ma + sensors (max. 400 ma) 5 ma Reverse voltage protection for U LS + U A Short-circuit protection for sensor supply Table 10: Technical data Communication S-BUS connection Shielded M12 connector, B-coded, 5 poles

24 Device Description WAGO-SPEEDWAY 767 3.7.4 Inputs Table 11: Technical data Inputs Number of inputs 4 Connection type M12 connectors, A coded, 5 poles Type of signal Currents and voltages (differencial inputs) Wire connection 2- to 4-wire (external shield (screen) via knurled nut) Measuring Range 0 20 ma, 0 22 ma, 4 20 ma, ±20 ma, 0 10 V, ±10 V Input impedance AI (U) 100 kω, AI (I) 200 Ω at 20 ma Type of cable, cabel length Shielded, 30 m 3.7.5 Analog Value Creation Table 12: Technical data Analog value creation Resolution Conversion method Monotonicity without error code Sampling time Sampling delay Sampling repeat time 16 bits SAR Yes 1 ms 1 ms (module) < 100 µs (channel/channel) 1 ms 3.7.6 Failures and Errors Table 13: Technical data Failures and errors Voltage proof Up to 32 V (internal current limitation) Maximum measuring error at 25 C ± 0.2 % of measuring range Temperature error ± 100 ppm/k of measuring range Maximum error over the full ± 0.6 % of the measuring range temperature range 3.7.7 Configurable Functions Table 14: Technical data Configurable functions Measuring range (per channel) Limiting values (per channel) Input filter (per channel) Substitute value (per channel) Online simulation per channel per channel/module 0 20 ma, 0 22 ma, 4 20 ma, ±20 ma, 0 10 V, ±10 V, user-defined Min/Max 50 Hz/60 Hz/filter off Value Lock/unlock; simulation value: (according to measuring range) diagnostics

Pos : 18.35 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Device Description 25 3.7.8 Diagnostics Table 15: Technical data Diagnostics Per channel Overrange/underflow measuring range Per channel Wire break at 4 20 ma Per channel Overcurrent Per channel Limit value violation (min/max) Per module Short circuit (sensor supply) Per module Wire break (sensor supply) Per module Undervoltage (U LS + U A ) 3.7.9 Process Image Table 16: Technical data Process image Process data width 8-byte data + status 3.7.10 Display Elements Table 17: Technical data Display elements SB: S-BUS status LED (green/red/orange) F: Error status LED (red) Ch1 Ch4 : Input signal status LED (yellow) Er1 Er4 : Input signal error LED (red) U LS + U A : Supply status LED (green) Indicators Non-retentive Pos : 18.34 /Serie 767 ( WAGO-SPEED WAY)/Gerätebeschr eibung/tec hnisc he Daten/I/O-M odule/potentialtr ennung I/O-M odule @ 7\mod_1265957068843_21.docx @ 50448 @ 3 @ 1 3.7.11 Isolation Table 18: Technical data Isolation Channel - Channel U LS, U A, S-bus No 500 VDC each

Pos : 18.36.3.1 /Alle Serien (Allgemeine D okumente) (Allgemeine M odul e)/zul ass ungen/standar dzul ass ungen/ce (Konfor mitäts kennz eic hnung) @ 3\mod_1224494777421_21.docx @ 24276 @ @ 1 Pos : 18.36.3.2 /Alle Serien (Allgemeine D okumente) (Allgemeine M odul e)/zul ass ungen/standar dzul ass ungen/cu Lus (UL508) @ 3\mod_1224055013140_0.docx @ 24020 @ @ 1 Pos : 18.36.3.3 /D okumentati on allgemein/gli ederungsel emente/------leerzeil e------ @ 3\mod_1224662755687_0.docx @ 24460 @ @ 1 Pos : 18.36.5 /Alle Serien (Allgemeine M odul e)/z ulass ungen/ex-z ul ass ungen/tü V AT EX/BVS 15 ATEX E098X: II 3G Ex na IIC T5 Gc II 3D Ex tc IIIB T 90 C Dc @ 22\mod_1427970660809_0.docx @ 179548 @ @ 1 Pos : 18.36.6 /Alle Serien (Allgemeine M odul e)/z ulass ungen/ex-z ul ass ungen/iec Ex (TÜ V N ord)/iec Ex BVS 15.0083X: Ex na IIC T 5 Gc Ex tc IIIB T90C D c @ 22\mod_1427970752942_0.docx @ 179552 @ @ 1 Pos : 18.37 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 26 Device Description WAGO-SPEEDWAY 767 Pos : 18.36.1 /Alle Serien (Allgemeine M odul e)/übersc hriften für all e Serien/Gerätebesc hr eibung/z ulassungen - Ü berschrift 2 @ 3\mod_1224055364109_21.docx @ 24030 @ 2 @ 1 3.8 Approvals Pos : 18.36.2 /Serie 767 ( WAGO-SPEEDWAY)/Gerätebeschr eibung/zul ass ung en/zul ass ung en I/O-Modul e 767- xxxx Allgemein, ohne Variantenangabe - Ei nleitung @ 24\mod_1447685953407_21.docx @ 195688 @ @ 1 The following approvals have been granted to 767-6401 module: Conformity Marking CUL US UL508 Pos : 18.36.4 /Serie 767 ( WAGO-SPEEDWAY)/Gerätebeschr eibung/zul ass ung en/zul ass ung en I/O-Modul e 767- xxxx Ex, ohne Variantenangabe - Ei nlei tung @ 24\mod_1447686155055_21.docx @ 195692 @ @ 1 The following Ex approvals are pending for 767-6401 module: BVS 15 ATEX E098X II 3 G Ex na IIC T5 Gc II 3 D Ex tc IIIB T90 C Dc IECEx BVS 15.0083X Ex na IIC T5 Gc Ex tc IIIB T90 C Dc

Pos : 19 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Device Description 27 Pos : 18.38.1 /Alle Serien (Allgemeine M odul e)/übersc hriften für all e Serien/Gerätebesc hr eibung/n or men und Ric htli nien - Ü berschrift 2 @ 4\mod_1242804031875_21.docx @ 33646 @ 2 @ 1 3.9 Standards and Guidelines Pos : 18.38.2 /Serie 767 ( WAGO-SPEEDWAY)/Gerätebeschr eibung/nor men und Richtlini en/n or men und Richtlinien I/O-Modul e 767- xxxx, ohne Variantenangabe - Ei nleitung @ 24\mod_1447686649865_21.docx @ 195700 @ @ 1 Th The module 767-6401 meets the following standards and guidelines: Pos : 18.38.3 /Alle Serien (Allgemeine M odul e)/nor men und Ric htlini en/em V-Nor men - Standard/EG-EM V-Richtli nie 2004/108/EG @ 7\mod_1274262373820_21.docx @ 56628 @ @ 1 EC EMC Directive 2004/108/EC Pos : 18.38.4 /Alle Serien (Allgemeine M odul e)/nor men und Ric htlini en/em V-Nor men - Standard/EM V C E-Störfestig kei t EN 61000-6- 2 @ 4\mod_1242797655625_21.docx @ 33591 @ @ 1 EMC CE-Immunity to interference acc. to EN 61000-6-2 Pos : 18.38.5 /Alle Serien (Allgemeine M odul e)/nor men und Ric htlini en/em V-Nor men - Standard/EM V C E-Störaussendung EN 61000-6-4 @ 4\mod_1242798273984_21.docx @ 33602 @ @ 1 EMC CE-Emission of interference acc. to EN 61000-6-4 Pos : 18.38.6 /Alle Serien (Allgemeine M odul e)/nor men und Ric htlini en/ex(i)-nor men/at EX-Ric htlini e 94/9/EG @ 19\mod_1404197489184_21.docx @ 157133 @ @ 1 Ex Directive 94/9/EC Pos : 18.38.7 /Alle Serien (Allgemeine M odul e)/nor men und Ric htlini en/ex(i)-nor men/explosionsfähig e Atmosphär e EN 60079-0 @ 14\mod_1360841627885_21.docx @ 111880 @ @ 1 Explosive atmosphere EN 60079-0 Devices General requirements Pos : 18.38.8 /Alle Serien (Allgemeine M odul e)/nor men und Ric htlini en/ex(i)-nor men/explosionsfähig e Atmosphär e EN 60079-15 @ 13\mod_1351072320086_21.docx @ 105289 @ @ 1 Explosive atmosphere EN 60079-15 Equipment protection by type of protection n Pos : 18.38.9 /Alle Serien (Allgemeine M odul e)/nor men und Ric htlini en/ex(i)-nor men/explosionsfähig e Atmosphär e EN 60079-31 @ 13\mod_1351072407879_21.docx @ 105292 @ @ 1 Explosive atmosphere EN 60079-31 Equipment dust ignition protection by enclosure t Pos : 18.38.10 /Alle Seri en (Allgemeine M odule)/n or men und Richtlinien/Ex(i)-Nor men/explosi onsfähige Atmos phäre IEC 60079-0 @ 15\mod_1368541723872_21.docx @ 119704 @ @ 1 Explosive atmospheres IEC 60079-0 General requirements Pos : 18.38.11 /Alle Seri en (Allgemeine M odule)/n or men und Richtlinien/Ex(i)-Nor men/explosi onsfähige Atmos phäre IEC 60079-15 @ 15\mod_1368542600428_21.docx @ 119712 @ @ 1 Explosive atmospheres IEC 60079-15 Equipment protection by type of protection "n" Pos : 18.38.12 /Alle Seri en (Allgemeine M odule)/n or men und Richtlinien/Ex(i)-Nor men/explosi onsfähige Atmos phäre IEC 60079-31 @ 15\mod_1368542725923_21.docx @ 119716 @ @ 1 Explosive atmospheres IEC 60079-31 Equipment dust ignition protection by enclosure "t"

Pos: 21.4 /Dokumentation allgemein/gliederungselemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 28 Mounting WAGO-SPEEDWAY 767 Pos : 20 /All e Seri en (Allgemei ne Module)/Ü berschriften für alle Serien/Monti eren/m ontier en - Übersc hrift 1 @ 3\mod_1225446744750_21.docx @ 24900 @ 1 @ 1 4 Mounting Pos: 21.1 /Serie 767 (WAGO-SPEED WAY)/M ontier en/i/o-modul e/m ontage_einl eitung 767- xxxx allgemein @ 5\mod_1249028190437_21.docx @ 39640 @ @ 1 The module can be fastened directly to your system using screws. It can also be mounted on a carrier rail using an adapter or fastened to a profile rail using a surface mounting profile. For mounting on a flat surface, WAGO offers spacers to assist in the mounting process that can be inserted between the 767 Series components. This helps by providing sufficient mounting distance for compact direct mounting, as well as eliminating gaps where dirt could accumulate. A cable tie can be fastened through each of two mounts in the spacer, which together serve to relieve strain from the sensor or actuator cables. Pos: 21.2 /Serie 767 (WAGO-SPEED WAY)/M ontier en/i/o-modul e/m ontage_hi nweis e 767- xxxx allgemei n_1 @ 5\mod_1249028727125_21.docx @ 39643 @ 2 @ 1 4.1 Information on Mounting The following information shall always be observed: Disconnect the power supply from the system before you start with installation. The maximum diameter of the drill hole of the module's mounting holes is not to exceed 4 mm. Otherwise, a full contact with function earth (FE) socket of the module not be guaranteed. This may lead to restrictions in the shielding. To protect the module from tensile forces that may arise, do not bridge spaces with it. Screw the module down only on flat contact surfaces to protect it from warping. Ensure that the connectors are not soiled during installation. Dirt and other such substances damage the contacts, allowing corrosion to develop. To avoid damaging the module, do not mount it in shear areas of moving devices. Arrange for a sufficient potential equalization in your system. Pos: 21.3 /Serie 767 (WAGO-SPEED WAY)/M ontier en/i/o-modul e/m ontage_hi nweis e 767- xxxx allgemei n_2 @ 7\mod_1267626531021_21.docx @ 51689 @ @ 1 Use all mounting holes to mount the module to your system so all FE (function earth) connections lie on a ground potential.

Pos: 21.6 /Dokumentation allgemein/gliederungselemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Mounting 29 Pos: 21.5 /Serie 767 (WAGO-SPEED WAY)/M ontier en/i/o-modul e/hi nweis : Montage_Ei nbaulag e_767- xxxx_i/o-module @ 24\mod_1448268126523_21.docx @ 196008 @ @ 1 Any mounting position is possible. Ensure a safe mounting position! In explosion hazardous environments no increased mechanical loads must be present at the installation location. If shocks are possible, a shock protection must be installed between the module and the possible source of the shock.

Pos: 21.9 /Dokumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 30 Mounting WAGO-SPEEDWAY 767 Pos: 21.7 /Serie 767 (WAGO-SPEED WAY)/M ontier en/i/o-modul e/m ontage_wer kzeug 767- xxxx allgemein_1 @ 5\mod_1249034240265_21.docx @ 39783 @ 2 @ 1 4.2 Tools and Accessories Required for Mounting Depending on the mounting type, the following tools are required for installation: A screwdriver for M4 fixing screws Drilling machine to pre-drill the mounting holes for the module to be mounted to the system and, if applicable, for the imperforated carrier rail. M4 thread cutter (bottoming tap or hand tap set) The WAGO accessories listed below are required for mounting. The associated item numbers can also be found in the 767 Series fieldbus manuals, in the "Accessories" section. Select the manual appropriate to the fieldbus you are using. Carrier rail adapter, including fixing screws and perforated or imperforated carrier rails (DIN rail 35 x 7.5 or DIN rail 35 x 15) according to EN 60715, also available from WAGO. or Profile adapter, including fixing screws Spacer (optional) Two M4x12 screws are required for direct mounting of the module. The length of the screw shaft is to be selected according to the mounting type. Pos: 21.8 /Serie 767 (WAGO-SPEED WAY)/M ontier en/i/o-modul e/m ontage_wer kzeug 767- xxxx allgemein_2 @ 7\mod_1267626863027_21.docx @ 51695 @ @ 1 Bore measurements When fastening the 767 Series components without a threaded hole, the clearance hole must not be wider than 4 mm so as to ensure safe contact of the FG (functional ground) connections.

Pos : 21.11 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/sicherheitshinweise/hinweis/hi nweis: 767- xxxx Distanz stück @ 8\mod_1279025151416_21.docx @ 59810 @ @ 1 Pos : 21.13 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/i/o-m odule/montage_direktmontage 767- xxxx_4xm 12 - Bil d @ 5\mod_1249284606687_21.docx @ 39829 @ @ 1 Pos : 21.14 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Mounting 31 Pos : 21.10 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/i/o-m odule/montage_direktmontage 767- xxxx allgemei n_1 @ 5\mod_1249029032515_21.docx @ 39651 @ 2 @ 1 4.3 Direct Mounting on Your System Mount the module directly on a level surface of your system, without using WAGO accessories. Direct mounting of the module is to be carried out as follows: 1. Disconnect the power supply from those devices on which you wish to mount the module. 2. Mark the drill holes using the hole drilling template printed on the packaging. You can also hold the module in the desired position and mark the drill holes. Ensure that there is sufficient space around the 767 Series components to enable you to connect all cable without problems. Direct Mounting We recommend using WAGO spacers for compact direct mounting. If these are used, the resulting additional distance from the second 767 Series component is to be noted. See section Mounting the Module > Mounting the Spacer in the Case of Compact Arrangement. Pos : 21.12 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/i/o-m odule/montage_direktmontage 767- xxxx allgemei n_2 @ 8\mod_1279025380479_21.docx @ 59813 @ @ 1 3. Fasten the module with two M4x12 screws via the two mounting holes. Figure 8: Mounting the module on a grounded frame or to another grounding point

Pos : 21.16 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/i/o-m odule/montage auf Tr agschi ene 767- xxxx_4xm 12 - Bil d @ 5\mod_1249284442703_21.docx @ 39821 @ @ 1 Pos : 21.17 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 32 Mounting WAGO-SPEEDWAY 767 Pos : 21.15 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/i/o-m odule/montage auf Tr agschi ene 767- xxxx allgemei n @ 5\mod_1249030348312_21.docx @ 39746 @ 23 @ 1 4.4 Mounting on a Carrier Rail (only with WAGO Accessories) 4.4.1 Fastening the Carrier Rail Adapter to the Module A carrier rail adapter is required to mount the module on carrier rails. Screw together the module and carrier rail adapter using the M4 threaded screws provided, as shown in the figure below. Figure 9: Fastening to the carrier rail adapter

Pos : 21.19 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/i/o-m odule/montage_befestigung auf Tragsc hi enenadapter 767- xxxx - Bil d @ 5\mod_1249030807718_21.docx @ 39757 @ @ 1 Pos : 21.20 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Mounting 33 Pos : 21.18 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/i/o-m odule/montage_befestigung auf Tragsc hi enenadapter 767- xxxx allgemein @ 5\mod_1249030636984_21.docx @ 39754 @ 3 @ 1 4.4.2 Fastening the Module with Carrier Rail Adapter to a Carrier Rail In order to provide a clear representation, the carrier rail adapter in the figure below is shown without module. When mounting the module to a carrier rail (DIN rail 35 x 7.5) using a carrier rail adapter, proceed as follows: 1. Disconnect the power supply from those devices on which you wish to mount the module. 2. Set the module onto the edge of the carrier rail (51) with the two notches (50). 3. Press the undersurface against the lower carrier rail edge until the latch (52) locks in place. Use end stops When mounting the rail vertically or if shock or vibration loading should occur, the use of end stops (item no.: 249-116 or 249-117) for stabilization is required. 50 51 52 Figure 10: Mounting the carrier rail adapter (exemplary)

Pos : 21.22 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/i/o-m odule/montage an einer Pr ofilsc hiene 767- xxxx_4xm12 - Bild @ 5\mod_1249284289078_21.docx @ 39813 @ @ 1 Pos : 21.23 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 34 Mounting WAGO-SPEEDWAY 767 Pos : 21.21 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/i/o-m odule/montage an einer Pr ofilsc hiene 767- xxxx allgemein @ 5\mod_1249031560359_21.docx @ 39765 @ 23 @ 1 4.5 Mounting on a Profile Rail (only with WAGO Accessories) 4.5.1 Fastening the Profile Adapter to the Module Aside from using carrier rail adapters to fasten the module, you also have the option to fasten it to a profile rail using the profile adapter and nuts, provided that this mounting type is supported by your system. You are to supply the necessary nuts. Screw together the module and the profile adapter using the M4 threaded screws provided, as shown in the following figure. Figure 11: Fastening to the profile adapter

Pos : 21.25 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Mounting 35 Pos : 21.24 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/i/o-m odule/montage mi t Pr ofiladapter an einer Pr ofilsc hiene 767- xxxx allgemein @ 5\mod_1249032474562_21.docx @ 39773 @ 3 @ 1 4.5.2 Fastening the Module with Profile Adapter to a Profile Rail To fasten the module to a profile rail of your system, two nuts are required with one screw each (length of screw threads must be compatible with your system). 1. Disconnect the power supply from those devices on which you wish to mount the module. 2. Insert the two screws into the holes above and beneath the fastened module on the profile adapter. 3. Fasten an appropriate nut on each of these screws. 4. Insert the profile adapter with the attached module into the profile rail of your system. Position it and tighten the screws.

Pos : 21.27 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/i/o-m odule/montage_besc hriftung austauschen 767- xxxx_4xm12 - Bild @ 5\mod_1249284529218_21.docx @ 39825 @ @ 1 Pos : 21.28 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 36 Mounting WAGO-SPEEDWAY 767 Pos : 21.26 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/i/o-m odule/montage_besc hriftung austauschen 767- xxxx allgemein @ 5\mod_1249034032812_21.docx @ 39780 @ 2 @ 1 4.6 Marking and Replacing the Marking Spaces The module marker card (10) and marking strip (12) are attached when delivered. The protective cover is to be removed when labeling the marking strip. To do this, proceed as follows: 1. Press the slot screwdriver (maximum slot width: 3mm) into the small opening under the marking strip cover (12) and lever it up. 2. Remove the marking strip cover. 3. Mark the marking strip with a waterproof pen. 4. Reinsert the marking strip cover and press it firmly in place. If the module's marker card (10) must be replaced, proceed in accordance with the step sequence described previously. New module marker cards can be obtained through WAGO. 10 12 Figure 12: Replacing the marking spaces

Pos : 21.30 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/i/o-m odule/montage_distanzstüc k T eil 1_767- xxxx_4xm 12 - Bil d @ 5\mod_1249284921328_21.docx @ 39843 @ @ 1 Pos : 21.31 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Mounting 37 Pos : 21.29 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/i/o-m odule/montage_distanzstüc k T eil 1_767- xxxx allgemei n @ 5\mod_1249281269203_21.docx @ 39797 @ 2 @ 1 4.7 Mounting the Spacer in the Case of Compact Arrangement By using the spacer, a sufficient mounting distance can be achieved when directly mounting the 767 Series components, and gaps can be eliminated where otherwise dirt and other substances could accumulate. In addition, it is possible to optimize the cable routing. For this purpose, two fastening lugs each are included on the spacer for cable ties. 1. Disconnect the power supply from those devices on which you wish to mount the module. 2. The spacer can only be inserted into the appropriate openings of the module from the bottom. To bind both components, place the module on the spacer or push the spacer from the bottom into the module. 3. Fasten the attached components on a flat surface by fastening the module to the grounded frame of your system or to another grounding point with two M4 screws via the mounting holes. Figure 13: Attaching a spacer to a module

Pos : 21.33 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/i/o-module/montage_distanzstüc k T eil 2_767- xxxx_4xm 12 - Bil d @ 5\mod_1249284983031_21.docx @ 39847 @ @ 1 Pos : 22 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 38 Mounting WAGO-SPEEDWAY 767 Pos : 21.32 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/i/o-m odule/montage_distanzstüc k T eil 2_767- xxxx allgemei n @ 5\mod_1249281510875_21.docx @ 39805 @ @ 1 4. When attaching 767 Series component, only one 767 component connected with a spacer can be attached and screwed on to the preceding component due to the mounting direction. The last 767 component is fastened without a spacer. Figure 14: Attaching another module with a spacer

Pos: 23.3 /Serie 767 (WAGO-SPEED WAY)/Wic htige Erläuterungen/Sicherheits hinweis e/gefahr/gefahr: El ektrische Spannung @ 8\mod_1278307980373_21.docx @ 58901 @ @ 1 Pos: 23.4 /Serie 767 (WAGO-SPEED WAY)/Wic htige Erläuterungen/Sicherheits hinweis e/achtung/achtung: H öc hste Strombelastbar keit der Vers orgungskontakte @ 8\mod_1278308653219_21.docx @ 58916 @ @ 1 Pos: 23.5 /Serie 767 (WAGO-SPEED WAY)/Wic htige Erläuterungen/Sicherheits hinweis e/achtung/achtung: Offene Ansc hlüss e @ 8\mod_1278308159953_21.docx @ 58910 @ @ 1 Pos: 23.7 /Serie 767 (WAGO-SPEED WAY)/Ans chl uss D aten- und Vers orgungs kabel/i/o-modul e/ans chl uss _Hinweise allgemeiner T eil 2 @ 5\mod_1249298321031_21.docx @ 40028 @ @ 1 WAGO-SPEEDWAY 767 Connecting Data and Supply Cables 39 Pos: 23.1 /Serie 767 (WAGO-SPEED WAY)/Ans chl uss D aten- und Vers orgungs kabel/i/o-modul e/01_ansc hl uss der Daten- und Vers orgungskabel - Übersc hrift 1 @ 8\mod_1278310189976_21.docx @ 58919 @ 1 @ 1 5 Connecting Data and Supply Cables Pos : 23.2 /Serie 767 (WAGO-SPEED WAY)/Ans chl uss D aten- und Vers orgungs kabel/i/o-modul e/02_hinweis e - Ü bers chrift 2 @ 8\mod_1278310190960_21.docx @ 58923 @ 2 @ 1 5.1 Notes Electric voltage! Operate the 767 Series components exclusively with 24 VDC PELV (Protective Extra Low Voltage) or SELV (Safety Extra Low Voltage) voltage sources. Failure to comply may result in electric shock. The highest current carrying capacity of the supply contacts is 4 A! Always observe the maximum current carrying capacity per supply line (U LS, U A ) for each 767 Series component and the overall power consumption for all 767 components. Neither of these values shall exceed 4 A since an increase in current causes the contacts to overheat and damages the 767 Series components. Information regarding the power demand of each 767 Series component can be found in the corresponding data sheet, which is available from www.wago.com. Exposed connections! If connections have not been closed with protective caps, liquid or dirt can penetrate the components of the 767 Series module and ruin it. Therefore, close all unnecessary connections with protective caps, which must be ordered separately, in order to maintain the IP67 degree of protection. (See section Accessories of the fieldbus coupler/controller manual.) Pos: 23.6 /Serie 767 (WAGO-SPEED WAY)/Ans chl uss D aten- und Vers orgungs kabel/i/o-modul e/ans chl uss _Hinweise allgemeiner T eil 1 @ 5\mod_1249286391531_21.docx @ 39858 @ @ 1 The connectors must be disconnected from the power supply when screws are tightened. Tighten the connectors by hand. To achieve the required torque (see below) for the connector, use the torque wrench with the order number 206-701. Torque for M8 connectors: Torque for M12 connectors: 0.6 Nm 1.0 Nm Use torque wrench 206-701! Only use the specified torque wrench. Using mechanical tools can cause the threads to strip. In this case, replace the module! Pos: 23.8 /Serie 767 (WAGO-SPEED WAY)/Ans chl uss D aten- und Vers orgungs kabel/i/o-modul e/ans chl uss _Hinweise T eil 3 @ 5\mod_1249287289312_21.docx @ 39865 @ @ 1 For both power supply and S-BUS, use only pre-assembled WAGO system cables so the specified characteristics of the technical data can be achieved.

Pos : 23.11 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 40 Connecting Data and Supply Cables WAGO-SPEEDWAY 767 Do not use drop lines under any circumstances. This can lead to amplified line reflections and signal distortions, which greatly impair the transmission quality. Pos: 23.9 /Serie 767 (WAGO-SPEED WAY)/Ans chl uss D aten- und Vers orgungs kabel/i/o-modul e/ans chl uss _Hinweise T eil 3.1 @ 8\mod_1278314911479_21.docx @ 58959 @ @ 1 Observe the exact positioning (coding) between plug and socket. Keep all cables a sufficient distance away from electromagnetic sources of interference in order to maintain a high level of interference resistance of the 767 system against electromagnetic emissions. Observe the minimum bending radiuses of the WAGO system cable. For more information, see the technical data at www.wago.com. When laying all cable, ensure that you do not lay it in shear areas of moving machine parts. Observe the correct layout of the potential equalization. Pos : 23.10 /Serie 767 ( WAGO-SPEED WAY)/Ansc hluss D aten- und Versorgungs kabel/i/o-m odule/ansc hlus s_z ubehör allgemein @ 5\mod_1249287357968_21.docx @ 39869 @ 2 @ 1 5.2 Required Accessories The WAGO accessories listed below are required for connecting the data and supply cable. The associated item numbers can also be found in the fieldbus manuals for 767 Series, in the "Accessories" section. Select the manual appropriate to the 767 Series fieldbus you are using. S-BUS M12 terminator, IP 67 S-BUS and supply cables, pre-assembled on both ends, IP 67 Torque wrench Protective caps

WAGO-SPEEDWAY 767 Connecting Data and Supply Cables 41 Pos : 23.12 /Serie 767 ( WAGO-SPEED WAY)/Ansc hluss D aten- und Versorgungs kabel/i/o-m odule/ansc hlus s_s-bu S allgemein @ 5\mod_1249287447062_21.docx @ 39873 @ 2 @ 1 5.3 Connecting the S-BUS Cables The S-BUS is used for communication between a fieldbus coupler and the connected 767 Series components. Requirement: A WAGO S-BUS cable pre-assembled on both ends is readily available to you. This is necessary for optimal signal transmission. The S-BUS terminator is available to you, which is necessary for communication. The following table outlines the assignment of the S-BUS connections: Table 19: S-BUS connection assignment Connection Contact Description IN OUT IN OUT 1 RD + TD + 2 RD TD 3 TD RD 4 TD + RD + 5 GND Connecting thread Shield

Pos : 23.13 /Serie 767 ( WAGO-SPEED WAY)/Ansc hluss D aten- und Versorgungs kabel/i/o-m odule/ansc hlus s_s-bus_4xm12 - Bil d @ 5\mod_1249301323125_21.docx @ 40063 @ @ 1 Pos : 23.14 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 42 Connecting Data and Supply Cables WAGO-SPEEDWAY 767 To connect the S-BUS cables to fieldbus coupler and I/O modules, proceed as follows: 1. Disconnect the power supply from those devices on which you have mounted the module. 2. Connect the S-BUS cable (S1) with the OUT connection (3) of the fieldbus coupler and the IN connection (1) of the module. For example, if two I/O modules have been connected to the fieldbus coupler, connect the S-BUS cables (S1, S2) to the associated IN and OUT connections, as shown in the following figure. 3. Tighten the plugs and sockets using the knurled-head screws. 4. Attach the S-BUS terminator (T) to the last I/O module as shown in the figure and tighten it. 1 3 Figure 15: S-BUS connected to a fieldbus coupler and modules

Pos : 23.16 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/sic herheits hinweise/ac htung/ac htung: Höchs te Strombel astbar keit der Vers orgungskontakte @ 8\mod_1278308653219_21.docx @ 58916 @ @ 1 Pos : 23.17 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Connecting Data and Supply Cables 43 Pos : 23.15 /Serie 767 ( WAGO-SPEED WAY)/Ansc hluss D aten- und Versorgungs kabel/i/o-m odule/ansc hlus s_spannungs vers orgung allgemein @ 5\mod_1249291817750_21.docx @ 39906 @ 2 @ 1 5.4 Connecting the Supply Cable The supply cable provides power to the module. Requirement: The WAGO supply cables K1 and K2, which are pre-assembled on both ends, must be available (see figure on next page). The following table outlines the assignment of the supply connections: Table 20: Supply connection assignment Connection Contact Description IN OUT 1 24 VDC U LS 2 24 VDC U A 3 0 V U LS 4 0 V U A The highest current carrying capacity of the supply contacts is 4 A! Always observe the maximum current carrying capacity per supply line (U LS, U A ) for each 767 Series component and the overall power consumption for all 767 components. Neither of these values shall exceed 4 A since an increase in current causes the contacts to overheat and damages the 767 Series components. Information regarding the power demand of each 767 Series component can be found in the corresponding data sheet, which is available from www.wago.com.

Pos : 23.19 /Serie 767 ( WAGO-SPEED WAY)/Ansc hluss D aten- und Versorgungs kabel/i/o-m odule/ansc hlus s_spannungs vers orgung _4xM 12 - Bild @ 5\mod_1249301804906_21.docx @ 40067 @ @ 1 Pos : 23.20 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 44 Connecting Data and Supply Cables WAGO-SPEEDWAY 767 Pos : 23.18 /Serie 767 ( WAGO-SPEED WAY)/Ansc hluss D aten- und Versorgungs kabel/i/o-m odule/ansc hlus s_spannungs vers orgung allgemein_2 @ 8\mod_1278320131837_21.docx @ 58967 @ @ 1 To connect the supply cable to the fieldbus coupler and modules, proceed as follows: 1. Disconnect the power supply from those devices on which you have mounted the module. 2. Connect the power supply cable (K1) to the OUT connection (9) of the fieldbus coupler and the IN connection (5) of the module. For example, if two modules have been connected to the fieldbus coupler, connect the power supply transmission cable (K1, K2) with the associated IN and OUT connections, as shown in the following figure. 3. Tighten the plugs and sockets using the knurled-head screws. 4. Screw a protective cap on all unused ports to ensure that IP 67 degree of protection is provided Information on connecting the power supply cable (K0) to the "IN" port a fieldbus coupler can be found in the appropriate manuals. (6) of 6 9 5 Figure 16: Supply cable connected to a fieldbus coupler and modules

Pos : 23.22 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/sic herheits hinweise/ac htung/ac htung: Höchs te Strombel astbar bei t der Vers.kontakte(Sensoren) und Sensorstromaufnahme 400 ma @ 8\mod_1278305007084_21.docx @ 58890 @ @ 1 Pos : 23.23 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Connecting Data and Supply Cables 45 Pos : 23.21 /Serie 767 ( WAGO-SPEED WAY)/Ansc hluss D aten- und Versorgungs kabel/i/o-m odule/ansc hlus s_sens oren 767-6401_4xM12 @ 5\mod_1249293071609_21.docx @ 39950 @ 2 @ 1 5.5 Connecting the Sensor Cable The sensor cables provide power to the connected sensors and transmit the sensor signals. When using cables that have not been pre-assembled, make sure that these cables are shielded and equipped with M12 plugs rated to IP67. The following table outlines the assignment of the sensor connections: Table 21: Connection assignment of analog inputs Connection Connection diagram IN IN X1, X3 X2, X4 The highest current carrying capacity of the supply contacts is 4 A! Ensure that the sensors are supplied with power from the U LS supply line. The sensors power consumption is to be taken into consideration when determining the present power demand for the U LS supply line. The total maximum power consumption of the sensors must not exceed 400 ma! Please note that the combined power consumption of all connected sensors is not to exceed 400 ma. The distribution of power among the existing connections is depending on the individual power requirements of the sensors.

Pos : 23.25 /Serie 767 ( WAGO-SPEED WAY)/Ansc hluss D aten- und Versorgungskabel/I/O-M odule/ansc hlüs se_4xm12_sensor en/aktor en - Bil d @ 5\mod_1249293750953_21.docx @ 39979 @ @ 1 Pos : 24 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 46 Connecting Data and Supply Cables WAGO-SPEEDWAY 767 Pos : 23.24 /Serie 767 ( WAGO-SPEED WAY)/Ansc hluss D aten- und Versorgungs kabel/i/o-m odule/ansc hlus s_sens oren 767-38xx, 64xx allgemei n @ 5\mod_1249297832343_21.docx @ 39987 @ @ 1 To connect the sensors to the digital inputs, proceed as follows: 1. Disconnect the power supply from those devices on which you have mounted the module. 2. Insert the sensor cable plug into an input socket (3) on the module, and tighten it via knurled-head screw. 3. Screw a protective cap on all unused ports to ensure that IP67 degree of protection is provided. 3 3 Figure 17: Connectors M12 (exemplary)

Pos : 26 /Serie 767 ( WAGO-SPEED WAY)/Wic htige Erläuterungen/Sicherheits hinweis e/achtung/achtung: Offene Ansc hlüss e @ 8\mod_1278308159953_21.docx @ 58910 @ @ 1 Pos : 28 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Commissioning 47 Pos : 25 /All e Seri en (Allgemei ne Module)/Ü berschriften für alle Serien/Inbetri ebnehmen - Konfigurier en - Parametri eren - Bedienen/In Betrieb nehmen - Ü bersc hrift 1 @ 4\mod_1240901452750_21.docx @ 31570 @ 1 @ 1 6 Commissioning Exposed connections! If connections have not been closed with protective caps, liquid or dirt can penetrate the components of the 767 Series module and ruin it. Therefore, close all unnecessary connections with protective caps, which must be ordered separately, in order to maintain the IP67 degree of protection. (See section Accessories of the fieldbus coupler/controller manual.) Pos : 27 /Serie 767 ( WAGO-SPEED WAY)/In Betrieb nehmen/i/o-modul e/inbetriebnahme allgmein @ 5\mod_1249365805015_21.docx @ 40130 @ @ 1 Before starting up the 767 node, ensure that the following requirements are met: Both 767 Series Fieldbus Coupler and Module 767-6401 have been properly mounted (See also fieldbus coupler manuals Series 767). The fieldbus, all necessary supply and sensor lines, and the S-BUS bus terminator are all securely fastened onto the appropriate connections (see section "Connecting Data and Supply Cables"). An appropriate potential equalization is implemented in your system. Shielding is carried out properly.

48 Parameterizing WAGO-SPEEDWAY 767 Pos : 29 /All e Seri en (Allgemei ne Module)/Ü berschriften für alle Serien/Inbetri ebnehmen - Konfigurier en - Parametri eren - Bedienen/Parametrier en - Übersc hrift 1 @ 3\mod_1223554593484_21.docx @ 23717 @ 1 @ 1 7 Parameterizing Pos: 30.1 /Serie 767 (WAGO-SPEED WAY)/Par ametrieren/i/o-m odule/parametri erung 767- xxxx allgemei n @ 5\mod_1249376935062_21.docx @ 40257 @ @ 1 All parameters listed here can be set using WAGOframe (or another FDT/DTM frame application) for the module. If you use a fieldbus for the parameterization, only certain parameters are configurable, depending on the type of fieldbus. Changing parameters! When parameters are incorrectly modified via FDT/DTM frame application (e.g., WAGOframe), machine components could be placed in a dangerous state and personnel and machines could be at risk. Before changing the parameters, ensure that the machine components are in a safe and defined state and switch off the higher-level controller. Also ensure before start-up that no personnel remain in the danger area of the machine components. For the parameterization of the module, an appropriate DTM is available. Via this DTM, you can parameterize the module either online or offline. The offline mode enables the parameterization of a module that is not yet present. In the offline mode, first store the parameters in a project and later transfer them to the module. In the online mode there is a direct link between the display and the connected module. If the module is in the online mode, its name is displayed in bold and italic font in the network window. Detailed informations. Detailed information on handling WAGOframe can be found in the fieldbus coupler manuals. The following sections provide information on the parameters and their descriptions.

Pos: 30.2 /Serie 767 (WAGO-SPEED WAY)/Par ametrieren/i/o-m odule/parametri erung 767- xxxx allgemei n - Bild @ 5\mod_1249377954171_21.docx @ 40275 @ @ 1 Pos: 30.3 /Dokumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Parameterizing 49 To open the parameterization user interface (DTM) of the module, double-click on the module in the "Network View" of WAGOframe. The parameterization user interface can also be opened by right-clicking on Offline Parameter or Online Parameter in the context menu. If several DTMs are open, select one via the corresponding tabs. Depending on the DTM you have selected, different buttons are provided: Table 22: DTM buttons Buttons [Read] (Online mode only) [Write] (Online mode only) [Close] (Online and offline mode) [Apply] (Offline mode only) [Help] (Online and offline mode) Description Reads and displays the parameters found in the module. Writes the modified values to the module. Closes the parameterization user interface (DTM). Applies the entries in the project. Please note that the project should also be subsequently saved (File > Save). Opens the online help for an entry that has been previously selected in the DTM (e.g., digital inputs, global setting). Shows/hides parameter overview. Displays the product data sheet. A PDF reader must be installed on your PC. Opens the DTM online help. Figure 18: Example of an open DTM, including parameters

Pos: 30.5 /Dokumentation allgemein/gliederungselemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 50 Parameterizing WAGO-SPEEDWAY 767 Pos: 30.4 /Serie 767 (WAGO-SPEED WAY)/Par ametrieren/i/o-m odule/parametri erung 767- xxxx Elektronisc hes T ypensc hild @ 5\mod_1249377784078_21.docx @ 40260 @ 2 @ 1 7.1 Electronic Type Label Table 23: Information on the module Parameter Vendor Release index Firmware revision Order number Description Serial number Date of production Designation Description Manufacturer FW.HW.FL FW: Actual firmware release index. When updating the firmware, please note that the firmware release index may not be conformed to the printed firmware release index on the side of the fieldbus coupler. HW: Hardware release index FL: Firmware loader release index General information on the module Electronic marking field

Pos: 30.8 /Dokumentation allgemein/gliederungselemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Parameterizing 51 Pos: 30.6 /Serie 767 (WAGO-SPEED WAY)/Par ametrieren/i/o-m odule/parametri erung 767- xxxx Di agnoseübersic ht_1 @ 14\mod_1360836957753_21.docx @ 111870 @ 2 @ 1 7.2 Diagnostic Overview The currently pending diagnostics existing on the module are displayed here. In this view of the DTM, you can enable simulation of the diagnostics, as well as disable transmission of the diagnostics. When disabling transmission, make sure that the display behavior of each LED changes that indicates the specific diagnostics (section "Diagnostics" > "LED Signaling"). The diagnostic overview is only available in online mode. Figure 19: Example of the diagnostic overview of a module (information may differ from the actual module) Pos : 30.7 /Serie 767 (WAGO-SPEED WAY)/Par ametrieren/i/o-m odule/parametri erung 767- xxxx Di agnoseübersic ht_2 @ 7\mod_1265811272140_21.docx @ 50279 @ @ 1 Table 24: Diagnostics setup Parameter Description Insert in PI Simulation Status By unselecting the checkbox, you specifically suppress evaluation and transmission of individual diagnostics. Doing so has no effect on the size of the process image. Even if a diagnostics has occurred, the diagnostic value "0" (no error) is transmitted to the higher-level controller. If you have selected the "Insert in PI" checkbox, the "Simulation" parameter is released. You can select the diagnostics you want to simulate. Click the [Write] button to transfer the simulated values to the module. Displays whether there is a diagnostics: X mark: There is a diagnostic message. Check mark: There is no diagnostic message.

Pos : 30.11 /Serie 767 ( WAGO-SPEED WAY)/Parametrier en/i/o-module/parametrier ung Kanaldi agnosen M ess ber eichsgrenzen und Anwendergrenzen @ 8\mod_1278393653313_21.docx @ 59050 @ @ 1 Pos : 30.14 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 52 Parameterizing WAGO-SPEEDWAY 767 Pos : 30.9 /Serie 767 (WAGO-SPEED WAY)/Par ametrieren/i/o-m odule/parametri erung 767-64xx Global e Di agnosen U LS und U A @ 7\mod_1265870806718_21.docx @ 50290 @ @ 1 Table 25: Information about existing module diagnostics Global Diagnostics Diagnostics Description Low voltage U LS Low voltage U A Pos : 30.10 /Serie 767 ( WAGO-SPEED WAY)/Parametrier en/i/o-module/parametrier ung Global e Di agnosen Kurzschl uss /Überlas t und U nterbr echung Fel dversorgung @ 8\mod_1278394655719_21.docx @ 59061 @ @ 1 Short circuit/ overload encoder supply If an undervoltage of the logic and sensor supply (U LS ) of < 18 V occurs on the module, a corresponding diagnostic is transmitted to the fieldbus coupler and the F-LED of the module illuminates. The module transmits the substitute value set by DTM as a process value. If an undervoltage of the actuator supply (U A ) of < 18 V occurs on the module, a corresponding diagnostic is transmitted to the fieldbus coupler and the F-LED of the module illuminates. The undervoltage of the actuator supply has no functional effect on the module. The module has detected a short circuit or overload of the encoder supply (only possible when field supply is switched on). Table 26: Information about an existing channel diagnostic Channel Diagnostics Diagnostics Description Measuring range underflow Measuring range overflow User limit underflow User limit overflow The module has detected an under-run of the measuring range on the respective channel (1 4). The module has detected an overrun of the measuring range on the respective channel (1 4). The module has detected an under-run of the user range on the respective channel (1 4). The module has detected an overrun of the user range on the respective channel (1 4). Pos : 30.12 /Serie 767 ( WAGO-SPEED WAY)/Parametrier en/i/o-module/parametrier ung Kanaldi agnosen Ü berstrom @ 8\mod_1278394228805_21.docx @ 59053 @ @ 1 Overcurrent The module has detected an overcurrent on the respective channel (1 4). Pos : 30.13 /Serie 767 ( WAGO-SPEED WAY)/Parametrier en/i/o-module/parametrier ung Kanaldi agnosen Dr ahtbr uch 6401 @ 8\mod_1278394381491_21.docx @ 59057 @ @ 1 Line break The module has detected an line break on the respective channel (1 4) (measuring range 4 20 ma).

WAGO-SPEEDWAY 767 Parameterizing 53 Pos : 30.15 /Serie 767 ( WAGO-SPEED WAY)/Parametrier en/i/o-module/parametrier ung 767-6401 Parameter der Eing änge und anwenderdefi nierte M ess ber eiche @ 5\mod_1249386167859_21.docx @ 40299 @ 22 @ 1 7.3 Analog Inputs Table 27: Overview of adjustable parameters for the analog inputs Parameter Designation Display mode process value Description Electronic marking field (max. 40 characters) Selection of the representation for displaying the process value and limit values: Process image value Measuring range - Decimal - Hexadecimal - Physical* Display of the current measured input value. If the "Simulation" parameter has been activated, enter the simulation value here. Select the measuring range here. You have the following options: 0 10 V* ± 10 V 0 20 ma 4 20 ma ±20 ma 0 22 ma (acc. NAMUR "NE 43") User-defined 1 User-defined 2 User-defined 3 User-defined 4 Use the measuring range 0 22 ma When using measuring range 0 22 ma, the measuring range underrange occurs at currents of < 3.8 ma and wirebreak at currents of < 3.6 ma. The measuring range low underrange occurs from 20.5 ma. Use the user-defined measuring ranges 1-4 The user-defined measuring ranges 1 4 can be configured by you (for more information, please see section "Parameterization" > "User-defined Measuring Ranges 1-4"). Simulation Upper user limit Lower user limit If this parameter is activated, you can simulate both the process value and the channel-specific diagnostics. Moreover, the input field for the process value is made available so that you can enter the input value that is to be simulated. Default setting: deactivated Here you can enter the limit value that is to trigger a diagnostic when exceeded. Here you can set the limit value that is to trigger a diagnostic when under-run:

54 Parameterizing WAGO-SPEEDWAY 767 Table 27: Overview of adjustable parameters for the analog inputs Parameter Substitute value Description Here you can enter the process value that is transmitted in the case of an error. Measuring range underflow Measuring range overflow User limit underflow User limit overflow Overcurrent Default setting: 0 If there is a limit value overrun or underrun, the corresponding diagnostic is displayed here. If the "Simulation" parameter is activated, you can simulate the corresponding diagnostic state by selecting this parameter. (Set in currentmeasuring mode in the case of overload (input deactivated simultaneously). Line break Extended parameters Input filter Indicates a wire break in the measuring range 4 20 ma. Set the input filter for the measured signals here. The following options are available: * Default setting No filter* 50 Hz 60 Hz

Pos : 30.16 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Parameterizing 55 7.4 User-defined Measuring Ranges 1 4 Table 28: Overview of adjustable parameters for the user-defined measuring ranges Parameter Description Copy presettings from Here you can select the area from which the settings for this measuring range should be acquired. You have the following options: Measuring type Physical conversion offset Physical conversion multiplier Physical unit string Enable user scaling User offset User gain 0 10 V ±10 V 0 20 ma 4 20 ma ±20 ma User-defined 1 User-defined 2 User-defined 3 User-defined 4 Here you can set the measuring path of the electronics. You have the following setting options: - Voltage* - Current Offset value for calculating the physical value F(x) from the process value (x). F(x) = (x + conversion offset) * conversion multiplier. Conversion factor (gain) for calculating the physical value F(x) from the process value (x). F(x) = (x + conversion offset) * conversion multiplier. Display of the physical measured value. Here you can activate and deactivate the user scaling ("User Offset" and "User Gain"). Offset value for scaling the process value. The process value is calculated according to the following formula: F(x) = (x + user offset) * user gain Conversion factor (user gain) for scaling the process value. The process value is calculated according to the following formula: F(x) = (x + user offset) * user gain

Pos : 30.19 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 56 Parameterizing WAGO-SPEEDWAY 767 Pos : 30.17 /Serie 767 ( WAGO-SPEED WAY)/Parametrier en/i/o-module/parametrier ung 767- xxxx Gl obal e Parameter @ 7\mod_1265881925390_21.docx @ 50320 @ 2 @ 1 7.5 Global Settings Table 29: Overview of parameters for the entire module Parameter Description Simulation diagnostic If the checkbox is selected, you can simulate a low voltage diagnostic. To generate a low voltage diagnostic, one or both of the two checkboxes "Low voltage U LS " and "Low voltage U A " must be selected. Default setting: unselected Low voltage U LS Low voltage U A In the case of an undervoltage of the logic and sensor supply (U LS ) or the actuator supply (U A ), the corresponding diagnostic is displayed here. Pos : 30.18 /Serie 767 ( WAGO-SPEED WAY)/Parametrier en/i/o-module/parametrier ung 767-38xx, 5xxx, 6401, 7401 Param. der Feldversorgung @ 5\mod_1249379780656_21.docx @ 40285 @ 2 @ 1 7.6 Parameters of Field Supply Table 30: Overview of adjustable parameters for the field supply Parameter Description Enable field supply Autorestart delay Simulation diagnostic Short circuit/overload Switch on the field supply (24VDC) here. Default setting: selected In the event of a short circuit, the sensor supply is switched off for a certain time. Here, enter this delay time (in 100 ms increments) after which the sensor supply is restarted. If the short circuit still exists, the process is repeated. The simulation can be used to simulate a short circuit. Default setting: unselected If simulation is deactivated, the respective error is displayed upon emergence. If simulation is activated, you can simulate one of the errors by selecting the appropriate parameter.

Pos : 31 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Parameterizing 57 Pos : 30.20 /Serie 767 ( WAGO-SPEED WAY)/Parametrier en/i/o-module/parametrier ung 767- xxxx Speicherung von Systemparametern @ 5\mod_1249380126156_21.docx @ 40288 @ 2 @ 1 7.7 Automatic Storage of System Parameters Some fieldbus couplers provide the "System Parameter Handling" feature. This serves to identify changes to the configuration of a 767 Series node and to the automatic configuration of the I/O modules. When an I/O module must be replaced due to a defect, you do not need to reconfigure the new I/O module. The stored parameters are automatically transferred to the new I/O module. Detailed information on this procedure can be found in the fieldbus coupler manuals in the "Parameter Setting via FDT/DTM" section. Pos : 30.21 /Serie 767 ( WAGO-SPEED WAY)/Parametrier en/i/o-module/parametrier ung 767- xxxx Aktualisier ung der Firmwar e @ 7\mod_1265881922171_21.docx @ 50306 @ 2 @ 1 7.8 Updating the Firmware When updating the module firmware, the saved module parameters can be overwritten. Therefore, check your existing configuration after updating the firmware.

Pos : 34 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 58 Process Image WAGO-SPEEDWAY 767 Pos : 32 /All e Seri en (Allgemei ne Module)/Ü berschriften für alle Serien/ noc h nic ht ei ns ortierte Ü berschriften müss en noc h eins orti ert werden Pr oz ess abbild - Übersc hrift 1 @ 4\mod_1240983067828_21.docx @ 31942 @ 1 @ 1 8 Process Image Pos : 33 /Serie 767 ( WAGO-SPEED WAY)/Proz ess abbild/i/o-module/proz ess abbil d 767- xxxx Ei nleitung @ 5\mod_1249373659937_21.docx @ 40223 @ @ 1 The process images for the module listed in the following sections describe the data length on the S-BUS (system bus). The implementation of the S-BUS process images onto the respective fieldbus process images can be found in the fieldbus coupler manuals. The process image is divided into two areas: an output data area and an input data area. The process image can contain process data with and without diagnostic information, independently of whether the transmission of synchronous diagnostic information has been selected. Synchronous diagnostic information Synchronous diagnostic information designates the cyclical transmission of diagnostic information in the process image. This is not selected in the original factory settings for the module. This is only possible when using a fieldbus coupler that supports the synchronous diagnostic function (e.g. 767-1101 or 767-2301). Detailed information about enabling the transmission of diagnostic information can be found in the manual for the fieldbus coupler being used: see the section about the device description file. In addition, you can also switch on synchronous diagnostic information in fieldbus couplers that support this function by using an FDT/DTM frame application (e.g. WAGOframe) in the corresponding DTM. For more information, see the Section "Parameterization via FDT/DTM" > "Diagnostics setting" in the fieldbus coupler manuals. Activate module diagnostics You can enable or suppress the individual module diagnostics. For more information, see the Section "Diagnostics Overview".

WAGO-SPEEDWAY 767 Process Image 59 Pos : 35 /Serie 767 ( WAGO-SPEED WAY)/Proz ess abbild/i/o-module/proz ess abbil d 767-6401 Eingangsdaten @ 5\mod_1249368617375_21.docx @ 40167 @ 2 @ 1 8.1 Input Data The image for the process data, which are sent from the I/O module to the fieldbus coupler, has a size of 8 bytes. If you configure synchronous diagnostic data for the I/O module, the process image has a size of 12 bytes. The diagnostic message is structured as follows: Table 31: Input data in the process image 15 8 Byte 0 \ ------------------- \/ ------------------- / 8 data bits (signed integer value) 7 0 Byte 1 \ ------------------- \/ ------------------- / 8 data bits (signed integer value) 15 8 Byte 2 \ ------------------- \/ ------------------- / 8 data bits (signed integer value) 7 0 Byte 3 \ ------------------- \/ ------------------- / 8 data bits (signed integer value) 15 8 Byte 4 \ ------------------- \/ ------------------- / 8 data bits (signed integer value) 7 0 Byte 5 \ ------------------- \/ ------------------- / 8 data bits (signed integer value) 15 8 Byte 6 \ ------------------- \/ ------------------- / 8 data bits (signed integer value) 7 0 Byte 7 Input value channel 1 Input value channel 1 Input value channel 2 Input value channel 2 Input value channel 3 Input value channel 3 Input value channel 4 Input value channel 4 \ ------------------- \/ ------------------- / 8 data bits (signed integer value)

60 Process Image WAGO-SPEEDWAY 767 Byte 8 7 0 Diagnostic message Byte 9 1 B : Measuring range underflow on channel X1 1 B : Measuring range underflow on channel X2 1 B : Measuring range underflow on channel X3 1 B : Measuring range underflow on channel X4 1 B : Measuring range overflow on channel X1 1 B : Measuring range overflow on channel X2 1 B : Measuring range overflow on channel X3 1 B : Measuring range overflow on channel X4 7 0 Diagnostic message 1 B : User limit underflow on channel X1* 1 B : User limit underflow on channel X2 1 B : User limit underflow on channel X3 1 B : User limit underflow on channel X4 1 B : User limit overflow on channel X1** 1 B : User limit overflow on channel X2 1 B : User limit overflow on channel X3 1 B : User limit overflow on channel X4 * Set when the process value is smaller than the "Lower Limit Value" parameter (see WAGOframe). ** Set when the process value is larger than the "Upper Limit Value" parameter (see WAGOframe).

Pos : 36 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Process Image 61 Byte 10 7 0 Diagnostic message 1 B : Overcurrent on channel X1* 1 B : Overcurrent on channel X2 1 B : Overcurrent on channel X3 1 B : Overcurrent on channel X4 1 B : Line break on channel X1** 1 B : Line break on channel X2** 1 B : Line break on channel X3** 1 B : Line break on channel X4** * Set when the input is parameterized as a current input and the supplied current exceeds the acceptable range. ** The wire break message appears in the measuring range of 4 20 ma. Byte 11 7 0 Diagnostic message 1 B : Short circuit encoder supply * always 0 1 B : Undervoltage U LS 1 B : Undervoltage U A * Can only occur when the field supply is enabled. Encoder supply In normal operation, the encoder supply is always switched on.

62 Process Image WAGO-SPEEDWAY 767 Pos : 37 /Serie 767 ( WAGO-SPEED WAY)/Proz ess abbild/i/o-module/proz ess abbil d 767-6401 Ausgangsdaten @ 5\mod_1249368718531_21.docx @ 40171 @ 2 @ 1 8.2 Output Data The process image for the output data that is transmitted from the fieldbus coupler to the I/O module has a size of 0 byte. If you configure a synchronous diagnostic confirmation of the I/O module, the process image has a size of 4 bytes. The diagnostic confirmation is structured as follows: Table 32: Output data in the process image Byte 0 7 0 Diagnostic confirmation Byte 1 1 B : Measuring range underflow on channel X1 confirmed 1 B : Measuring range underflow on channel X2 confirmed 1 B : Measuring range underflow on channel X3 confirmed 1 B : Measuring range underflow on channel X4 confirmed 1 B : Measuring range overflow on channel X1 confirmed 1 B : Measuring range overflow on channel X2 confirmed 1 B : Measuring range overflow on channel X3 confirmed 1 B : Measuring range overflow on channel X4 confirmed 7 0 Diagnostic confirmation 1 B : User limit underflow on channel X1 confirmed 1 B : User limit underflow on channel X2 confirmed 1 B : User limit underflow on channel X3 confirmed 1 B : User limit underflow on channel X4 confirmed 1 B : User limit overflow on channel X1 confirmed 1 B : User limit overflow on channel X2 confirmed 1 B : User limit overflow on channel X3 confirmed 1 B : User limit overflow on channel X4 confirmed

Pos : 38 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Process Image 63 Byte 2 7 0 Diagnostic confirmation Byte 3 1 B : Overcurrent on channel X1 conf. 1 B : Overcurrent on channel X2 confirmed 1 B : Overcurrent on channel X3 confirmed 1 B : Overcurrent on channel X4 confirmed 1 B : Line break on channel X1 confirmed 1 B : Line break on channel X2 confirmed 1 B : Line break on channel X3 confirmed 1 B : Line break on channel X4 confirmed 7 0 Diagnostic confirmation 1 B : Short circuit encoder supply confirmed 1 B : Not assigned 1 B : Undervoltage U LS confirmed 1 B : Undervoltage U A confirmed

Pos: 41.2 /Serie 767 (WAGO-SPEED WAY)/Wic htige Erläuterungen/Sicherheits hinweis e/hi nweis /Hinweis: 767-6xxx/- 7xxx Betriebs meldungen Deakti vierbar e Diag nos en @ 7\mod_1265892405468_21.docx @ 50350 @ @ 1 Pos: 41.3 /Serie 767 (WAGO-SPEED WAY)/Di agnose/i/o-modul e/betriebs mel dungen 767- xxxx Abbildung 4xM12 @ 5\mod_1249454812578_21.docx @ 40396 @ @ 1 64 Diagnostics WAGO-SPEEDWAY 767 Pos : 39 /All e Seri en (Allgemei ne Module)/Ü berschriften für alle Serien/Diag nos e/di agnos e - Ü bersc hrift 1 @ 4\mod_1240831069471_21.docx @ 31372 @ 1 @ 1 9 Diagnostics Pos : 40 /All e Seri en (Allgemei ne Module)/Ü berschriften für alle Serien/Diag nos e/led-signalisierung - Ü bers chrift 2 @ 4\mod_1240831118032_21.docx @ 31375 @ 2 @ 1 9.1 LED Signaling Pos: 41.1 /Serie 767 (WAGO-SPEED WAY)/Di agnose/i/o-modul e/betriebs mel dungen Einl eitung @ 7\mod_1268130796113_21.docx @ 52028 @ @ 1 The following table lists the operating messages that are indicated via LEDs. Information regarding remedies of certain causes is also provided. Disabling specific diagnostics Use the diagnostic overview (section "Parameterizing" > "Diagnostic Overview") to disable specific diagnostics (see F- and Er-LED). In this case, the corresponding LED is disabled (off). 15 16 17 17 19 18 Figure 20: LEDs indicating operational messages (exemplary) Pos: 41.4 /Serie 767 (WAGO-SPEED WAY)/Di agnose/i/o-modul e/betriebs mel dungen 767- xxxx Allgemei n (Pos.15, T eil 1) @ 5\mod_1249461825765_21.docx @ 40406 @ @ 1 Table 33: Operating messages 1 Pos. LED Color/Status Cause Remedy/information 15 SB Off Red, flashing, 4 Hz Red, flashing, 1 or 2 Hz Green Low voltage; U LS not available. S-BUS error on module. The module is being restarted via the fieldbus coupler. Data exchange is in process; process data values are valid. The module is in RUN mode. Check the power supply. Check whether the S-BUS cable is connected. Check the S-BUS cable for damages. Check whether the fieldbus coupler firmware is compatible with the module. If the flashing frequency is 1Hz, please contact WAGO Support. -

Pos: 41.5 /Serie 767 (WAGO-SPEED WAY)/Di agnose/i/o-modul e/betriebs mel dungen 767- xxxx DI/AI Allgemein (Pos. 15, Teil 2) @ 7\mod_1268637528606_21.docx @ 52460 @ @ 1 Pos: 41.6 /Dokumentation allgemein/gliederungselemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Diagnostics 65 Table 33: Operating messages 1 Pos. LED Color/Status Cause Remedy/information 15 SB 15 SB Green and orange, flashing, 1 Hz Orange, flashing, 2 Hz Orange and green, flashing, 4 Hz Orange, flashing, 1 Hz Orange and green, flashing, 2 Hz Orange Orange, flashing, 4 Hz Green, flashing, 1 Hz Green, flashing, 2 Hz The set substitute value is applied to the module. The module has detected the S-BUS. The last module is being detected in the 767 node. The fieldbus coupler is addressing the module in the 767 node. The S-BUS parameters are being stored by the fieldbus coupler. The firmware is being updated. The module is attempting to establish communication with the fieldbus coupler. The module is in HOLD mode. The module is in STOP mode. Can be set by the fieldbus coupler if fieldbus is missing. Check the fieldbus connection and the status of the higherlevel controller. - Check the S-BUS terminator and/or the S-BUS cables. - - All 767 Series components are being updated by the fieldbus coupler within the node. Check the power supply to upstream 767 Series component and/or check the S-BUS cable for damages. Is initiated by the fieldbus coupler. The last input values transferred to the fieldbus coupler are kept in the process image. Is initiated by the fieldbus coupler. The input values are set to 0 in the process image.

Pos: 41.8 /Serie 767 (WAGO-SPEED WAY)/Di agnose/i/o-modul e/betriebs mel dungen 767- xxxx U LS und UA (Pos. 18 + 19) @ 8\mod_1278577022948_21.docx @ 59316 @ @ 1 Pos : 42 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 66 Diagnostics WAGO-SPEEDWAY 767 Pos: 41.7 /Serie 767 (WAGO-SPEED WAY)/Di agnose/i/o-modul e/betriebs mel dungen 767-6401 F, I/O (Pos. 16 + 17) @ 5\mod_1249463533640_21.docx @ 40414 @ @ 1 Table 34: Operating messages 2 Pos. LED Color/status Cause Remedy/information 16 F 17 Ch1 Ch4 Er1 Er4 18 U A 19 U LS Red Yellow Off Red Off Green Off Green Off An undervoltage of < 18 V of the actuator supply and/or logic and sensor supply is present. Short circuit on sensor supply. Check the power supply of the previous 767 component. Repair the short circuit. Fieldbus supply interruption. Resolve the overload. The corresponding inputs are - ready for operation. Measuring range exceeded or under-run on the corresponding input. Overload of inputs. An undervoltage of < 18 V of the logic and sensor supply is present. Measuring range exceeded or under-run on the corresponding input. Overload of inputs. An undervoltage of < 18 V of the logic and sensor supply is present. Actuator supply U A is present. Actuator supply U A is not present. Logic supply and sensor supply U LS are present. Logic supply and sensor supply U LS are not present. Select the correct measuring area for the input signal. Select the correct measuring area (e.g., 10 V) and the correct signal type (current, voltage) for the input signal. Check the power supply of the previous 767 component. Select the correct measuring area for the input signal. Select the correct measuring range (e.g., 10 V) and the correct signal type (current, voltage) for the input signal. Check the power supply of the previous 767 component. - Connect the power supply and check the voltage level, if applicable. - Connect the power supply and check the voltage level, if applicable.

Pos : 47 /Serie 767 ( WAGO-SPEED WAY)/Wic htige Erläuterungen/Sicherheits hinweis e/vorsic ht/vorsicht: H eiße Ansc hlussbuc hs en @ 8\mod_1278308217203_21.docx @ 58913 @ @ 1 Pos : 49 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Service 67 Pos : 43 /All e Seri en (Allgemei ne Module)/Ü berschriften für alle Serien/Ser vic e ( Wartung)Ser vic e - Ü berschrift 1 @ 4\mod_1241771948421_21.docx @ 32830 @ 1 @ 1 10 Service Pos : 44 /Serie 767 ( WAGO-SPEED WAY)/Ser vic e/i/o-m odule/ser vic e 767- xxxx allgemein 1 @ 7\mod_1267790134757_21.docx @ 51798 @ @ 1 This section contains information on maintenance and service. Pos : 45 /Serie 767 ( WAGO-SPEED WAY)/Ser vic e/i/o-m odule/ser vic e 767- xxxx Firmwareupdate @ 8\mod_1278567931191_21.docx @ 59308 @ 2 @ 1 10.1 Updating the Firmware The firmware for the module can be updated. This takes place via the USB connection of a fieldbus coupler. Additional information can be found in the fieldbus manuals in section "Updating the Firmware". Pos : 46 /Serie 767 (WAGO-SPEED WAY)/Ser vic e/i/o-m odule/ser vic e 767- xxxx allgemein 2 @ 5\mod_1249468812328_21.docx @ 40442 @ 23 @ 1 10.2 Replacing the Module To replace a module, e.g., to change variants, proceed as described follow. 10.2.1 Disconnecting the Cables Before removing the connectors, clean the module to ensure that no dirt or other material comes in contact with the connections. This can lead to damage of the contacts. To unplug the cables, proceed as follows: 1. Disconnect the power supply from those devices on which you have mounted the module. Hot connection sockets! Even when taking into account derating, high surface temperatures on the metallic connection sockets and on the enclosure can arise during operation. If the 767 Series component has been in operation, allow it to cool off before moving it. Pos : 48 /Serie 767 ( WAGO-SPEED WAY)/Ser vic e/i/o-m odule/ser vic e 767- xxxx allgemein 2.1 @ 8\mod_1278568242751_21.docx @ 59311 @ @ 1 2. Unscrew all screw connections and remove the cables.

Pos : 52 /Serie 767 ( WAGO-SPEED WAY)/Ser vic e/i/o-m odule/ser vic e 767- xxxx_m12 allgemein2 - Bild @ 5\mod_1249471167718_21.docx @ 40463 @ @ 1 Pos : 53 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 68 Service WAGO-SPEEDWAY 767 Pos : 50 /Serie 767 ( WAGO-SPEED WAY)/Ser vic e/i/o-m odule/ser vic e 767- xxxx allgemein 2.2 @ 8\mod_1278649957222_21.docx @ 59430 @ 3 @ 1 10.2.2 Removing the Module from Your System To remove the module from your system's framework, proceed as follows: 1. Disconnect the power supply from those devices on which you have mounted the module. 2. Release the module from your system by unscrewing the M4 screws. Pos : 51 /Serie 767 ( WAGO-SPEED WAY)/Ser vic e/i/o-m odule/ser vic e 767- xxxx allgemein 3 @ 5\mod_1249469687968_21.docx @ 40445 @ 3 @ 1 10.2.3 Removing the Module from the Carrier Rail In order to keep the representation unambiguous, the carrier rail adapter in the following figure (B, C) is shown without module. If the module is mounted on a carrier rail, proceed with the removal as follows: 1. Disconnect the power supply from those devices on which you have mounted the module. 2. To remove the module, press down the release actuator of the carrier rail adapter using a slot screwdriver (B) and remove it from the carrier rail (C). A B C Figure 21: Removing the module (with the carrier rail adapter) from the carrier rail

Pos : 55 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Service 69 Pos : 54 /Serie 767 ( WAGO-SPEED WAY)/Ser vic e/i/o-m odule/ser vic e 767- xxxx allgemein 4 @ 5\mod_1249471383765_21.docx @ 40467 @ 332 @ 1 10.2.4 Removing the Module from the Profile Adapter If the module is mounted on a profile adapter, proceed with the removal as follows: 1. Disconnect the power supply from that part of the system on which you have mounted the module before attempting to remove it. 2. Unscrew the screws on which the nuts are fastened and remove the module from the profile rail of your system. 3. Unscrew the screws that connect the module with the profile adapter. 10.2.5 Connecting the Module To connect the module, proceed as described in Sections 4 through 6. If necessary, the parameters of the previous module are transferred to the new module, depending on the type of fieldbus coupler being used. For more information, see section "Parameterizing" > "Automatic Storage of System Parameters". 10.3 Disposal Do not dispose of the 767 Series components in the household waste; observe the laws which apply to them. You can also contact a certified waste management company.

Pos: 56.3 /Dokumentation allgemein/gliederungselemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 70 Use in Hazardous Environments WAGO-SPEEDWAY 767 Pos : 56.1 /All e Seri en ( Allgemei ne Module)/Eins atz in Ex- Ber eichen/eins atz in explosionsgefährdeten Bereic hen - Übersc hrift 1 @ 3\mod_1224075191281_21.docx @ 24084 @ 1 @ 1 11 Use in Hazardous Environments Pos: 56.2 /Serie 767 (WAGO-SPEED WAY)/Eins atz in Ex- Ber eichen/ei ns atz ber eic h Serie 767 @ 22\mod_1428492971659_21.docx @ 179803 @ @ 1 The modular system WAGO-SPEEDWAY 767 (electrical equipment) is designed for use in Zone 2 and 22 hazardous areas. The following sections include both the general identification of components (devices) and the installation regulations to be observed. The individual subsections of the Installation Regulations section must be taken into account if the fieldbus coupler and the I/O module of the series WAGO-SPEEDWAY 767 has the required approval or is subject to the range of application of the ATEX directive.

Pos: 56.6 /Serie 767 (WAGO-SPEED WAY)/Eins atz in Ex- Ber eichen/beis piel bedruc kung der AT EX- und IEC- Ex-zug elass enen 767-Ger äte gemäß C ENELEC und IEC_2013 @ 22\mod_1428493093265_21.docx @ 179811 @ @ 1 Pos: 56.7 /Dokumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Use in Hazardous Environments 71 Pos: 56.4 /Serie 750 (WAGO-I/O-SYST EM)/Eins atz in Ex- Ber eichen/beis piel hafter Aufbau der Kennz eic hnung - Übersc hrift 2 @ 3\mod_1224157499140_21.docx @ 24182 @ 2 @ 1 11.1 Marking Configuration Examples Pos: 56.5 /Serie 750 (WAGO-I/O-SYST EM)/Eins atz in Ex- Ber eichen/kennz eic hnung für Europa gemäß ATEX und IEC- EX - Übersc hrift 3 @ 3\mod_1224157620203_21.docx @ 24185 @ 3 @ 1 11.1.1 Marking for Europe According to ATEX and IEC-Ex Figure 22: Side Marking Example for approved WAGO SPEEDWAY 767 Series Fieldbus Coupler according to ATEX and IECEx Table 35: Legend for Figure Side Marking Example for approved WAGO SPEEDWAY 767 Series Fieldbus Coupler according to ATEX and IECEx Printing on Text Description BVS 15 ATEX E098X Approving authority and certificate numbers IECEx BVS 15.0083X Dust II Equipment group: All except mining 3D Category 3 (Zone 22) Ex Explosion protection mark Tc Dc Type of protection and equipment protection level (EPL): protection by enclosure IIIB Explosion group of dust T90 C Max. surface temperature of the enclosure (without a dust layer) Gases II Equipment group: All except mining 3G Category 3 (Zone 2) Ex Explosion protection mark na Gc Type of protection and equipment protection level (EPL): Non-sparking equipment IIC Explosion group of gas and vapours T5 Temperature class: Max. surface temperature 100 C

Pos : 56.10 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 72 Use in Hazardous Environments WAGO-SPEEDWAY 767 Pos : 56.8 /All e Seri en ( Allgemei ne Module)/Eins atz in Ex- Ber eichen/errichtungs besti mmungen - Ü berschrift 2 @ 3\mod_1232453624234_21.docx @ 26370 @ 2 @ 1 11.2 Installation Regulations Pos : 56.9 /All e Seri en ( Allgemei ne Module)/Eins atz in Ex- Ber eichen/errichtungs besti mmungen Einl eitung_2013 @ 14\mod_1360582328318_21.docx @ 111371 @ @ 1 For the installation and operation of electrical equipment in hazardous areas, the valid national and international rules and regulations which are applicable at the installation location must be carefully followed.

WAGO-SPEEDWAY 767 Use in Hazardous Environments 73 Pos : 56.11 /Serie 767 ( WAGO-SPEED WAY)/Ei ns atz i n Ex-Bereic hen/bes. Bed. für den sic heren Ex-Betrieb g em. ATEX-Zertifikat BVS 15 ATEX E098X @ 22\mod_1428493230701_21.docx @ 179815 @ 3 @ 1 11.2.1 Special Conditions for Safe Use (ATEX Certificate BVS 15 ATEX E098X) 1. The Modular I/O-System has to be protected against UV emitting light. 2. The permitted ambient temperature range is 25 C +50 C. 3. The Modular I/O-System has to be installed in a way that it is protected against any mechanical and electrostatical hazards. This may be realized by a protection measure according to the documentation mentioned in the Test Report. In this case the earthling of the metal cage has to be established by the end user. 4. The plug shall be in accordance with all applicable clauses of IEC/EN 60079-0 and IEC/EN 60079-15. A minimum degree of protection IP54 according to IEC/EN 60529 shall be ensured. This may be realized by accessories series 756 of WAGO Kontakttechnik GmbH & Co. KG. In this case the torque is 0.6 Nm. Pos : 56.12 /D okumentati on allgemei n/gli ederungsel emente/---seitenwec hs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1

Pos : 57 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 74 Use in Hazardous Environments WAGO-SPEEDWAY 767 Pos : 56.13 /Serie 767 ( WAGO-SPEED WAY)/Ei ns atz i n Ex-Bereic hen/bes. Bed. für den sic heren Ex-Betrieb g em. IEC Ex Z ertifi kat IECEx BVS 15.0083X @ 22\mod_1428493277377_21.docx @ 179819 @ 3 @ 1 11.2.2 Special Conditions for Safe Use (IEC Ex Certificate IECEx BVS 15.0083X) 1. The Modular I/O-System has to be protected against UV emitting light. 2. The permitted ambient temperature range is 25 C +50 C. 3. The Modular I/O-System has to be installed in a way that it is protected against any mechanical and electrostatical hazards. This may be realized by a protection measure according to the documentation mentioned in the Test Report. In this case the earthling of the metal cage has to be established by the end user. 4. The plug shall be in accordance with all applicable clauses of IEC/EN 60079-0 and IEC/EN 60079-15. A minimum degree of protection IP54 according to IEC/EN 60529 shall be ensured. This may be realized by accessories series 756 of WAGO Kontakttechnik GmbH & Co. KG. In this case the torque is 0.6 Nm.

WAGO-SPEEDWAY 767 Appendix 75 Pos : 58 /All e Seri en (Allgemei ne Module)/Ü berschriften für alle Serien/Anhang - Z ubehör Anhang - Ü bers chrift 1 @ 4\mod_1239874070437_21.docx @ 30560 @ 1 @ 1 12 Appendix Pos : 59 /Serie 767 ( WAGO-SPEED WAY)/Anhang/I/O-Module/Anhang 767-6401 Proz ess werte @ 5\mod_1249472184734_21.docx @ 40478 @ 2 @ 1 12.1 Process Values of the Module The following tables provide an overview of possible process values that can be transmitted by the module: Table 36: Process values at input voltages from 0 V to 10 V Input voltages Binary input value Hexadecimal Decimal 0 V to 10 V 0,00 0000000000000000 0000 0 1,25 0001000000000000 1000 4096 2,50 0010000000000000 2000 8192 3,75 0011000000000000 3000 12288 5,00 0100000000000000 4000 16384 6,25 0101000000000000 5000 20480 7,50 0110000000000000 6000 24576 8,75 0111000000000000 7000 28672 10,00 0111111111111111 7FFF 32767 Table 37: Process values at input voltages from -10 V to +10 V Input voltages Binary input value Hexadecimal Decimal -10 V to +10 V -10,00 1000000000000000 8000-32768 -8,75 1001000000000000 9000-28672 -7,50 1010000000000000 A000-24576 -6,25 1011000000000000 B000-20480 -5,00 1100000000000000 C000-16384 -3,75 1101000000000000 D000-12288 -2,50 1110000000000000 E000-8192 -1,25 1111000000000000 F000-4096 0,00 0000000000000000 0000 0 1,25 0001000000000000 1000 4096 2,50 0010000000000000 2000 8192 3,75 0011000000000000 3000 12288 5,00 0100000000000000 4000 16384 6,25 0101000000000000 5000 20480 7,50 0110000000000000 6000 24576 8,75 0111000000000000 7000 28672 10,00 0111111111111111 7FFF 32767

76 Appendix WAGO-SPEEDWAY 767 Table 38: Process values at input currents from 0 ma to 20 ma Input current Binary input value Hexadecimal Decimal 0 ma to 20 ma 0,00 0000000000000000 0000 0 2,50 0001000000000000 1000 4096 5,00 0010000000000000 2000 8192 7,50 0011000000000000 3000 12288 10,00 0100000000000000 4000 16384 12,50 0101000000000000 5000 20480 15,00 0110000000000000 6000 24576 17,50 0111000000000000 7000 28672 20,00 0111111111111111 7FFF 32767 Table 39: Process values at input currents from 0 ma to 22 ma Input current Binary input value Hexadecimal Decimal 0 ma to 22 ma 0,00 0000000000000000 0000 0 2,50 0000111010001100 0E8C 3724 5,00 0001110100010111 1D17 7447 7,50 0010101110100011 2BA3 11171 10,00 0011101000101111 3A2F 14895 12,50 0100100010111010 48BA 18618 15,00 0101011101000110 5746 22342 17,50 0110010111010001 65D1 26065 20,00 0111010001011101 745D 29789 22,00 0111111111111111 7FFF 32767 Table 40: Process values at input currents from 4 ma to 20 ma Input current Binary input value Hexadecimal Decimal 4 ma to 20 ma 4,00 0000000000000000 0000 0 6,00 0001000000000000 1000 4096 8,00 0010000000000000 2000 8192 10,00 0011000000000000 3000 12288 12,00 0100000000000000 4000 16384 14,00 0101000000000000 5000 20480 16,00 0110000000000000 6000 24576 18,00 0111000000000000 7000 28672 20,00 0111111111111111 7FFF 32767

Pos : 60 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 Appendix 77 Table 41: Process values at input currents from -20 ma to +20 ma Input current Binary input value Hexadecimal Decimal -20 ma to +20 ma -20,00 1000000000000000 8000-32768 -17,50 1001000000000000 9000-28672 -15,00 1010000000000000 A000-24576 -12,50 1011000000000000 B000-20480 -10,00 1100000000000000 C000-16384 -7,50 1101000000000000 D000-12288 -5,00 1110000000000000 E000-8192 -2,50 1111000000000000 F000-4096 0,00 0000000000000000 0000 0 2,50 0001000000000000 1000 4096 5,00 0010000000000000 2000 8192 7,50 0011000000000000 3000 12288 10,00 0100000000000000 4000 16384 12,50 0101000000000000 5000 20480 15,00 0110000000000000 6000 24576 17,50 0111000000000000 7000 28672 20,00 0111111111111111 7FFF 32767

=== Ende der Liste für T extmar ke Inhalt_mitte === 78 Appendix WAGO-SPEEDWAY 767 Pos : 61 /Serie 767 ( WAGO-SPEED WAY)/Anhang/I/O-Module/Anhang 767-6401 Di agnos einfor mation @ 5\mod_1249472218812_21.docx @ 40482 @ 2 @ 1 12.2 Diagnostic Information Some fieldbus couplers display the error code in the form of an attribute path (CIA), through which diagnostics are clearly assigned. Other fieldbus couplers (e.g., PROFINET IO oder PROFIBUS DP) convert the attribute path into a fieldbus-specific message. The following diagnostic codes can be generated by the module: Table 42: Diagnostics of the module Diagnostic Message Attribute Path Classification C I A hort circuit/overload of field supply This function is only active when the field supply is switched on. Low voltage U LS (sensor supply) Low voltage U A (actuator supply) 16 1 128 Diagnostic alarm 50 1 128 Diagnostic alarm 50 1 129 Diagnostic alarm Table 43: Diagnostics of the individual channels of the module Diagnostic Message Attribute Path Classification C I A Measuring range underflow Measuring range overflow User limit underflow User limit overflow Overcurrent Line break 10 10 10 10 10 10 Channel (1, 2, 3 or 4) Channel (1, 2, 3 or 4) Channel (1, 2, 3 or 4) Channel (1, 2, 3 or 4) Channel (1, 2, 3 or 4) Channel (1, 2, 3 or 4) Use the "Diagnostic Overview" to disable specific diagnostics. 128 Diagnostic alarm 129 Diagnostic alarm 130 Process alarm 131 Process alarm 132 Diagnostic alarm 133 Diagnostic alarm

Pos : 64 /D okumentation allgemei n/glieder ungs elemente/---seitenwechs el--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1 WAGO-SPEEDWAY 767 List of Figures 79 Pos : 63 /D okumentation allgemei n/verz eic hniss e/abbil dungs verz eic hnis - Übersc hrift og und Verz eichnis @ 3\mod_1219222916765_21.docx @ 21080 @ @ 1 List of Figures Figure 1: Connectors... 16 Figure 2: Marking possibilities and fastening (exemplary)... 17 Figure 3: Display elements (exemplary)... 18 Figure 4: Labeling... 19 Figure 5: Label on the module... 20 Figure 6: Schematic diagram... 21 Figure 7: Dimensions of the module in millimeters (exemplary)... 22 Figure 8: Mounting the module on a grounded frame or to another grounding point... 31 Figure 9: Fastening to the carrier rail adapter... 32 Figure 10: Mounting the carrier rail adapter (exemplary)... 33 Figure 11: Fastening to the profile adapter... 34 Figure 12: Replacing the marking spaces... 36 Figure 13: Attaching a spacer to a module... 37 Figure 14: Attaching another module with a spacer... 38 Figure 15: S-BUS connected to a fieldbus coupler and modules... 42 Figure 16: Supply cable connected to a fieldbus coupler and modules... 44 Figure 17: Connectors M12 (exemplary)... 46 Figure 18: Example of an open DTM, including parameters... 49 Figure 19: Example of the diagnostic overview of a module (information may differ from the actual module)... 51 Figure 20: LEDs indicating operational messages (exemplary)... 64 Figure 21: Removing the module (with the carrier rail adapter) from the carrier rail... 68 Figure 22: Side Marking Example for approved WAGO SPEEDWAY 767 Series Fieldbus Coupler according to ATEX and IECEx... 71

80 List of Tables WAGO-SPEEDWAY 767 Pos : 65 /D okumentation allgemei n/verz eic hniss e/tabell enverz eichnis - Übersc hrift og und Verz eichnis @ 3\mod_1219222958703_21.docx @ 21084 @ @ 1 List of Tables Table 1: Number Notation... 9 Table 2: Font Conventions... 9 Table 3: Legend for figure "Connectors"... 16 Table 4: Legend for figure "Marking possibilities and fastening"... 17 Table 5: Legend for figure "Display elements"... 18 Table 6: Legend for figure "Labeling"... 19 Table 7: Description of manufacturing number... 20 Table 8: Technical data General information... 23 Table 9: Technical data Supply... 23 Table 10: Technical data Communication... 23 Table 11: Technical data Inputs... 24 Table 12: Technical data Analog value creation... 24 Table 13: Technical data Failures and errors... 24 Table 14: Technical data Configurable functions... 24 Table 15: Technical data Diagnostics... 25 Table 16: Technical data Process image... 25 Table 17: Technical data Display elements... 25 Table 18: Technical data Isolation... 25 Table 19: S-BUS connection assignment... 41 Table 20: Supply connection assignment... 43 Table 21: Connection assignment of analog inputs... 45 Table 22: DTM buttons... 49 Table 23: Information on the module... 50 Table 24: Diagnostics setup... 51 Table 25: Information about existing module diagnostics... 52 Table 26: Information about an existing channel diagnostic... 52 Table 27: Overview of adjustable parameters for the analog inputs... 53 Table 28: Overview of adjustable parameters for the user-defined measuring ranges... 55 Table 29: Overview of parameters for the entire module... 56 Table 30: Overview of adjustable parameters for the field supply... 56 Table 31: Input data in the process image... 59 Table 32: Output data in the process image... 62 Table 33: Operating messages 1... 64 Table 34: Operating messages 2... 66 Table 35: Legend for Figure Side Marking Example for approved WAGO SPEEDWAY 767 Series Fieldbus Coupler according to ATEX and IECEx... 71 Table 36: Process values at input voltages from 0 V to 10 V... 75 Table 37: Process values at input voltages from -10 V to +10 V... 75 Table 38: Process values at input currents from 0 ma to 20 ma... 76 Table 39: Process values at input currents from 0 ma to 22 ma... 76 Table 40: Process values at input currents from 4 ma to 20 ma... 76 Table 41: Process values at input currents from -20 ma to +20 ma... 77 Table 42: Diagnostics of the module... 78 Table 43: Diagnostics of the individual channels of the module... 78

=== Ende der Liste für T extmar ke Verzeic hnis_hi nten === WAGO-SPEEDWAY 767 List of Tables 81

Pos : 67 /D okumentation allgemei n/einband/einband H andbuc h - R üc kseite 2015 @ 9\mod_1285229376516_21.docx @ 64944 @ @ 1 === Ende der Liste für T extmar ke Ei nband_hinten === WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 D-32385 Minden Hansastraße 27 D-32423 Minden Phone: 05 71/8 87 0 Fax: 05 71/8 87 1 69 E-Mail: info@wago.com Internet: http://www.wago.com