Linear Luminaire with LED Series EXLUX 6402/2



Similar documents
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Plug and Socket Devices CES 63 A Series 8579

Terminal Boxes Series 8146

Series 8146/5-V37 and Series 8150/5-V37

Plug and Socket Devices SolConeX 16 A Series 8570

Control and Distribution Boxes made of Stainless Steel Series 8150

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Flameproof Audible Signal 115 db (A) Series YA90

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Floodlight Range Installation Guide

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

A good connection. International approvals.

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Control Stations Made of Polyester Resin Series 8146

Compact pressure switch Flameproof enclosure Ex d Model PCA

nano led THE GREEN LIGHT

Explosion proof enclosures

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Operating Instructions

H45 LED - Direct and indirect pendant

Cable Plug acc. to DIN EN , Form A

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Inductive sensor NI10-M18-Y1X-H1141

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Solenoid Valve Island Type 3965

Technical data sheet TDS0070

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Abtech Custom Solutions

8146/5 Series Breaker Panelboards

Watertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W

7 Lighting Technology

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Emergency Light Fittings

Product and functional description

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens CLASSIC umodule QLE

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Redundancy Module QUINT-DIODE/40

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Technical Data. Dimensions

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Operating Instructions

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

ASSEMBLED SOCKET-COMBINATIONS

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC / CLE CLASSIC umodule CLE

Brochure. Light fittings, floodlights and beacons New LED range for hazardous areas

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Guide to enclosures for potentially explosive atmospheres

HERZ-Thermal Actuators

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

IVIOS LED III. LUM Technical Information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Terminal Box. Specifications TNCN

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Vario-Series Accessories

Technical Data. Dimensions

Threaded resistance thermometer Model TR10-C, with protection tube

Software and Display instruments

LED HIGHBAY COMMERCIAL & INDUSTRIAL DESIGNED MANUFACTURED AND WARRANTED IN AUSTRALIA

T5 LongLast. GE Lighting DATA SHEET

Fluxa Area floodlights for high pressure discharge lamps and LEDs

Capacitive Prox E2K-X

LED control gear. LED control gear

Electronic Pressure Switch EDS 300

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

The most sustainable lighting solution. QL 85W Induction Lighting System

Invue ECM/EMM EPIC MEDIUM W

Nightspot A2 Floodlights for LEDs and high pressure discharge lamps

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

e explosion-proof emergency light fittings battery sets for zone 1/21 and zone 2/22 e 187/ nd 187/188...

3/2-way Solenoid Valve, direct-acting, NC or NO

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Superlight Compact Nano

Instructions for Safe Use

3500/93 System Display

Flow switches Series AD/VH

Nightscape High performance floodlights and spotlights for discharge lamps

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

Power Supplies 3. SDN-P DIN Rail Series

PUNKT LAMP 150 Design: focus lighting

GROENEVELD AUTOMATIC GREASING SYSTEMS

Transcription:

> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened (option) > Type of protection gas: na (non sparking) www.stahl.de ATEX / IECEx Zone 0 1 2 20 21 22 For use in: x x x Explosion Protection Global (IECEx) Gas and dust IECEx IBE 14.0080X EX na d op is IIC T4 Gc EX tb IIIC T100 C Db EX tc IIIC T100 C Dc Europe (ATEX) Dust IBExU14ATEX1292 E II 2 D Ex tb IIIC T100 C Db Gas and dust Certifications and certificates Certificates IBExU14ATEXB020 X E II 3 G Ex na d op is IIC T4 Gc E II 3 D Ex tc IIIC T100 C Dc IECEx, ATEX 16745E00 WebCode 6402B Lighting /1

Selection Table Version Diffusor Length Power consumpti on mm Cable entry Order number Art. no. Weight kg EXLUX 6402/2 with 700 28 W M25 6402/2182-5500-250 244216 4.200 M20 6402/2182-5500-150 244217 4.200 1310 52 W M25 6402/2284-5500-250 244218 6.400 NOTE The light fittings are delivered without mounting material. These accessories must be ordered separately! M20 6402/2284-5500-150 244219 6.400 Technical Data Electrical data Ballast Inrush current AC: 220... V ±10 %; 50... 60 Hz DC: 200... 250 V ±10 % I peak = 53.5 A; Δt = 124.8 ms maximum number of luminaires per miniature circuit breaker: Power factor ) 0.93 Type 10 A 16 A 20 A 25 A B 8 12 16 20 C 13 21 27 33 Degree of protection IP66 / IP67 (IEC 60598) Protection class I (with internal PE connection) Impact strength (IK code) IK10 (IEC 62262) Disconnection of the light When opening the luminaire Switch with safety lock (optional); when opening the central lock all poles of the voltage supply to the ballast are disconnected; contacts of the switching element are positive opening, they can only be switched on again when the luminaire trough and the central locking system are closed. Luminous characteristics Luminous flux 6402/21.2-.5..-..0 6402/22.4-.5..-..0 Power consumption [W] 28 52 Colour rendering [Ra] ) 80 ) 80 Colour temperature [K] 5000 5000 without diffuser Luminous flux [lm] 2919 5375 Luminaire efficiency [lm/w] 105 103 Light output ratio [%] 85 85 with diffuser Luminous flux [lm] 2558 4670 Luminaire efficiency [lm/w] 92 90 Light output ratio [%] 75 76 Values apply to T a = +25 C. Luminous flux decrease at T a = +55 C to 85% of the nominal value. /2 Lighting

Technical Data Ambient conditions Operating temperature -30... +55 C range Storage -30... +75 C Service life Service life T a ( 25 C T a ( 45 C T a ( 55 C L 70B 10C 10 100,000 h 100,000 h 50,000 h L xb yc z At the end of the service life: Luminous flux decrease to "x" percent up to "y" percent of all luminaires fall below "x" up to "z" percent of all luminaires break down completely Mechanical data Material Enclosure Material Polyester resin, glass fibre-reinforced Colour colour grey, similar to RAL 7035 Seal Silicone foam gasket in the lamp cover Translucent cover Polycarbonate Luminaire locking Central locking which can be opened/closed using a socket key M8 / wrench size 13, hinged lamp cover Mounting / Installation Cable glands Standard luminaire Plastic: Metal: 2 x M25 x 1.5 cable gland 8161 and 2 x M25 x 1.5 stopping plugs 8290 (enclosed) 2 x metal plates M20 x 1.5 connected by means of PE for metal cable entries Attention: cable entries must be ordered separately Special: max. 4 bores for M20, M25, NPSM ½ max. 2 bores for NPT ¾ Metal cable glands: M20 x 1.5, M25 x 1.5; earthing of the metal cable entries by means of metal plates Connection Standard: Spring clamp terminals 5-pole: L1, L2, L3, N, PE (with through wiring) Clamping range: 1 x 0.75... 4 mm 2 (solid/finely stranded) (2 free clamping units for each pole available) Special: Terminal block with covering 5-pole: L1, L2, L3, N, PE Clamping range: 2x 0.75... 6 mm 2 (solid); 2 x 0.75... 4 mm 2 (finely and extra finely stranded) Through wiring Standard light fitting with Light fittings are equipped with internal through wiring. Ingoing and outgoing leads can be connected to the opposite sides. Terminals: see techn. data Wiring cross section: 2.5 mm 2 for max. 16 A. Assembly Optional Standard luminaire without On the connection side, there are 2 bores M25 x 1.5 for cable entries for ingoing and outgoing wiring of the connection line (ingoing and outgoing leads on one side). Standard: Special: 2 x M8 insert nuts in the enclosure Mounting grooves in the enclosure for the use of fastening and ceiling rails for variable luminaire mounting (variable mounting distances for luminaires L = 700 mm: 320... 480 mm; L = 1310 mm: 670... 930 mm) Lighting /3

Light distribution curves 16615E00 28 W without diffusor 28 W with diffusor 16616E00 16617E00 52 W without diffusor 52 W with diffusor 16618E00 /4 Lighting

Accessories and Spare Parts Designation Figure Description Art. no. Weight Lamp cover for luminaire L=700 222427 0.639 Socket key for luminaire L=1310 222428 1.149 M8 / wrench size 13; to open/close the central locking kg 222430 0.210 15507E00 Ring bolt M8, direct mounting in insert nuts 115736 0.112 Pipe clamp 05378E00 R 1 1 / 2 222459 1.200 R 1 1 / 4 222458 1.250 15583E00 R 2 222460 1.300 with mounting rail for a variable mounting distance; Material: stainless steel Mounting bracket mounting clamp mounted on a mounting rail for a variable mounting distance 222456 0.400 15585E00 Mounting rail for a variable mounting distance 222826 0.300 15584E00 Pole mounting sleeve 16985E00 for the subsequent mounting on lights 18 W and 36 W, completely with assembly parts 227512 3.200 Ceiling and wallmounting bracket 222827 2.400 15586E00 mounted on a mounting rail for a variable mounting distance; Material: stainless steel Lamp can be swiveled in steps of 15 Bracket for wall mounting with tube for side entry lamp; with tube, length 400 mm, d 42 mm 108947 2.480 05460E00 Switch Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.026 10809E00 Lighting /5

Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations b L1 L2 M25 x 1,5 L3 M25 x 1,5 h1 15440E00 Dimensions Luminaire 28 W 52 W L1 700 [27.56] 1310 [51.57] L2 1) 400 [15.75] 800 [31.50] L3 2) 320... 480 [12.60... 18.90] 670... 930 [26.38... 36.61] b 184 [7.24] 184 [7.24] h1 125 [4.92] 125 [4.92] 1) fixed mounting distance 2) variable mounting distance EXLUX 6402 Standard luminaire Dimensional Drawings for Assembly Parts and Accessories (All Dimensions in mm [inches]) - Subject to Alterations 12 [ 0, 47 ] 30,50 [ 1, 20 ] 215 [ 8.46] 18,50 [ 0, 73 ] 30 [1,18]. 9 [0,35] 193-198 [7,60-7,80] 124 [ 4, 88] 11 [ 0, 43] 86 [ 3, 39] 74 [ 2, 91] 32 [1,26] 6,10 [0,24] ø 6,10 ø 8,10 9 [ø. 0, 24] [ø 0,32] [0,35] 13 [0,51] 215 [ 8, 46] 193-198 [7,60. - 7,80]. 143 [5,63] 15778E00 15779E00 Mounting rail /6 Lighting

Dimensional Drawings for Assembly Parts and Accessories (All Dimensions in mm [inches]) - Subject to Alterations ø 20 [ø 0,79] 24 [0,95] ø 42 [ø 1 1/4] ø 48 [ø 1 1/2] ø 60 [ø 2] 162 [6,38] 172 [6,77] 180,50 [1 1/4] 187,50 [1 1/2] 200,50 [2] 15782E00 15781E00 15783E00 Ring bolt fitted in insert nut of the luminaire 10x15 A Mounting bracket fitted in mounting rail Pipe clamp fitted in mounting rail A [1,39] 34 65,50-74,50 [2,58-2,93] 110 [4,33] 8,50 [0,35] 296 [11,65] 8,50 [0,35] 15780E00 Wall mounting bracket fitted in mounting rail 198 [7,80] [6,30] 42 [ 1,65] 120 [4,72] 143 [5,63] 104 [4,09] ø 10,50 [ ø 0,41] 130 [5,12] 220 [8,66] 03257E00 Bracket for wall mounting with pipe section 15 SW 5 20 [0,79] 180 [7,09] 400 [15,75] We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Lighting /7