BTL5-S1 -M -HB/WB-FA /F -C Micropulse Linear Transducer - Rod Style



Similar documents
BTL5-P1 _-M -HB/WB-FA /F -C Micropulse Linear Transducer - Rod Style

PROFIBUS-DP BTL5-T1 -M/U -B/Z-S103. Technical Description User's Guide. english

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

D. PARAMETER SPECIFICATION Measured Variable: Displacement

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Redundancy Module QUINT-DIODE/40

How To Power A Schen

Inductive sensor NI10-M18-Y1X-H1141

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Cross-beam scanning system to detect slim objects. 100 mm in

BNI EIP Z009 IP67 Module, Unmanaged Switch

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Series 6000 Torque measured metal bellow coupling

Encoder WDGI 58H.

Description. Dimensions. Features. precision works better

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Three-phase monitoring relay CM-PFE

Mounting Instructions. Torque Transducer. A en

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Rotary actuators Rotary wing drives Series RAK. Brochure

Telephone- and leased line modem for industrial applications TD-36

ABSOLUTE ROTARY ENCODER ETHERNET/IP

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Pressure transmitter For general industrial applications Model A-10

BOS 73K... BOS 74K...

Analog signal converters CC-E I/I Current / current isolators

Instruction Manual Differential Pressure Transmitter

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

User s Manual Inductive Analog Position Sensor BIL SmartSens No E Edition 0802

STRATO LED Drivers 70W, Single output

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

RM4TG20 three-phase network control relay RM4-T - range V

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Absolute Rotary Encoder E6CP

Series 7500 Torque Sensor

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage Regulator SPAU 341 C. Product Guide

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Adjustment functions for both span and shift have been incorporated

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

BNI IOL K006 BNI IOL K006. IO-Link Sensor-Hub analog User s Guide

Electronic Pressure Switch EDS 3000

MAGNETOSTICTIVE TRANSDUCER

DS 600. A contact free flux gate based current measurement sensor 600A rms

Proximity Switches RS (Reed Switch)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Digital input modules

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Operating Instructions for Plastic Flow Meter. Model: KSK

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Electronic Pressure Switch EDS 300

Operating instructions

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

R&S ZNC Vector Network Analyzer Specifications

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

49 Series - Relay interface modules A. Features

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

and Accelerometers

Subminiature Load Cell Model 8417

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

R&S ZNBT8 Vector Network Analyzer Specifications

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

maxon sensor maxon sensor

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

ABSOLUTE OPTICAL ROTARY ENCODER MULTITURN BIT PARALLEL

48 SERIES Relay interface modules 10 A

Liquid Level Limit Switch liquiphant T FTL 20

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Reaction Torque Sensor

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

ACTUATOR LA37 PRODUCT DATA SHEET

QR12 (1.22 ) Diameter Optical Encoder

Transcription:

User's Manual Balluff GmbH Schurwaldstraße 9 73765 Neuhausen a.d.f. Germany Phone +49 7158 173-0 Fax +49 7158 5010 balluff@balluff.de www.balluff.com 1

Contents 1 Safety Advisory... 2 1.1 Proper application... 2 1.2 Qualified personnel... 2 1.3 Use and inspection... 2 1.4 Scope... 2 2 Function and Characteristics... 3 2.1 Characteristics... 3 2.2 Function... 3 2.3 SSI interface... 3 3 Installation... 4 3.1 Mounting... 5 3.2 Transducer, Installation... 5 3.3 Magnets, Installation... 6 4 Wiring... 6 4.1 Cable axial and radial... 6 5 Startup... 7 5.1 Check connections... 7 5.2 Turning on the system... 7 5.3 Check output values... 7 5.4 Check functionality... 7 5.5 Fault conditions... 7 6 Versions (indicated on part label)... 7 6.1 Included in shipment... 7 6.2 Available lengths... 7 7 Accessories... 8 7.1 Magnets... 8 7.2 Compatible devices... 8 7.3 Mounting nut... 8 8 Technical Data... 9 8.1 Dimensions, weights, ambient conditions... 9 8.2 Supply voltage (external)... 9 8.3 Control signals... 9 8.4 Connection to processor... 9 1 Safety Advisory Read this manual before installing and operating the Micropulse Transducer. 1.1 Proper application The BTL5 Micropulse transducer is intended to be installed in a machine or system. Together with a controller (PLC) or a processor it comprises a position measuring system and may only be used for this purpose. Unauthorized modifications and non-permitted usage will result in the loss of warranty and liability claims. 1.2 Qualified personnel This guide is intended for specialized personnel who will perform the installation and setup of the system. 1.3 Use and inspection The relevant safety regulations must be followed when using the trans- ducer system. In particular, steps must be taken to ensure that should the transducer system become defective no hazards to persons or property can result. This includes the installation of additional safety limit switches, emergency shutoff switches and maintaining the permissible ambient conditions. 1.4 Scope This guide applies to the model BTL5-S1...-M...HB/WB... Micropulse transducer. An overview of the various models can be found in chapter 6 Versions (indicated on part label) on page 7. Note: For special versions, which are indicated by an -SA _ designation in the part number, other technical data may apply (affecting calibration, wiring, dimensions etc.). 2

2 Function and Characteristics 2.1 Characteristics Micropulse transducers feature: High data security: Output data are checked for validity and plausibility in the µc. Very high resolution, repeatability and linearity Absolute output signal Measurement range monitoring with "Out of Range" Bit 2 21. Immunity to shock, vibration, and contamination Tough assembly Housing of stainless steel Wear- and maintenance-free measuring principle Pressure rated to 600 bar Teflon cable Capability of connecting cable guard systems Enclosure rating per IEC 60529: Cable version IP 68 (type tested at 5 bar / 48 h) IP69/K with connected cable guard system 2.2 Function The transducer contains a tubular waveguide enclosed by an outer stainless steel rod. A magnet attached to the moving member of the machine or to the cylinder piston is moved over the rod and its position constantly updated. The magnet defines the measured position on the waveguide. An internally generated INIT pulse interacts with the magnetic field of the magnet to generate a magnetostrictive torsional wave in the waveguide which propagates at ultrasonic speed. The torsional wave arriving at the end of the waveguide is absorbed in the damping zone. The wave arriving at the beginning of the waveguide creates an electrical signal in the coil surrounding the waveguide. The corresponding value is output as synchronous serial data (SSI) via the RS 485/422 interface. This takes place with high precision and repeatability within the measuring range indicated as the nominal stroke length. At the rod end is a damping zone, within which no reliable signal is available, but which may be entered by the magnet. The electrical connection between the transducer, the processor/controller and the power supply is via a cable. Dimensions for installing the Micropulse transducer: Fig. 3-1 Dimensions for installing the magnet: Fig. 3-4 2.3 SSI interface Depending on the BTL version, the SSI interface uses 24 or 25 bits and the position values are transmitted in Gray or binary code. The max. clock frequency t depends on the cable length section 8 Technical Data on page 9. For the purposes of error detection bit 2 21 is provided as an Out of Range message, Fig. 2-1 and Fig. 2-2. Sending of the position values is finished within time t m. It is started with the falling edge of the last clock pulse. After this time the BTL is ready for the next data transmission. +Clk Clock sequence 1 2 3 4 23 24 t t v t m +Data MSB LSB Out of ➀ Range Fig. 2-1: Pulse diagram, example with 24 bit coding ➀ only for resolution > 5 µm Null point t < t m t v = 150 ns t m = 31 µs measured with 1 m cable independent of the clock frequency The time t m starts with the falling edge of the last clock impulse (bit 24 or bit 25 depending on the version). End point Position of magnet: 1) out of the measurement range 2) within the measurement range 3) magnet not present "Out of Range" Bit 2 21 will be set after the occurence of the event. Value of the output data 2 0... 2 20 : 1a) 0 1b) max. at end point + 10 mm 2) proportional to distance 3) 0 Technical data are valid within the measurement range only, i.e. between null and end point. Fig. 2-2: Output data shown with "Out of Range" situation 3

3 Installation BTL5...HB/WB-...-C - axial M18 1.5 HB: 30-1mm WB: 2" -0.04" ➀ Magnet Nom. length = stroke ➁ Damping zone ➀ Ø 5 for Hookspanner Ø 58-62, tightening torque max. 100 Nm Mounting surface Thread size HB: M18 1.5 WB: 3/4"-16UNF Blind hole M4 4/ 6 deep ➀ unusable area ➁ not included BTL5...HB/WB-...-C - radial HB: 30-1mm WB: 2" -0.04" ➀ Magnet ➁ Nom. length = stroke Damping zone ➀ Blind hole M4 4/ 6 deep Mounting surface Fig. 3-1: Transducer BTL5-...HB/WB-..., Dimensions Important Installation Notes: The contact surface of the transducer must be completely contacted by the mounting surface. The O-ring supplied must make a perfect pressure seal, i.e. the bevel for the O-ring must be configured exactly as shown in Fig. 3-3. To achieve secure mounting, use the proper nut for the mounting thread. When tightening the transducer, do not exceed a tightening torque of 100 Nm. For horizontal mounting of transducer with stroke lengths greater than 500 mm, the pressure tube should be supported or attached at its end. When installing in a hydraulic cylinder, do not allow the magnet ring to rub against the pressure tube. The bore diameter in the piston and cylinder rod should be at least 13 mm. 4

3 Installation (cont.) 3.1 Mounting When possible, use non-magnetizable material for attaching the transducer and magnet ring. Fig. 3-2. When attaching the transducer to magnetizable materials, appropriate measures must be taken to protect against magnetic disturbances Fig. 3-2. Note the recommended distance of the transducer and cylinder from strong, external magnetic fields. non-magnetizable material ➀ - ➂ for magnetizable materials ➃ for non-magnetizable materials Fig. 3-2: Mounting a = Spacer made of non-magnetizable materials b = Magnet 3.2 Transducer, Installation The smallest permissible distance between magnet ring and rod mounting surface is shown in Fig. 3-1. The transducer has either a M18 1.5 thread or a 3/4"-16UNF thread for mounting. The sealing is carried cut with the O-ring supplied at the flange facing. Threaded hole M18 1.5 per ISO 6149 O-ring 15.4 2.1 Threaded hole 3/4"-16UNF per SAE J475 O-ring 15.3 2.4 Bevel for O-ring Threaded hole Fig. 3-3: Threaded hole for mounting the BTL with O-ring 5

3 Installation (cont.) 3.3 Magnets, Installation A magnet is required for each transducer. This must be ordered separately. Fig. 3-4. For mounting the magnet we recommend to use non-magnetizable material. Fig. 3-2. BTL-P-0814-GR-PAF 4 Wiring (cont.) Note the following when making electrical connections: System and control cabinet must be at the same ground potential. To ensure the electromagnetic compatibility (EMC) which Balluff warrants with the CE Mark, the following instructions must be strictly followed. BTL-P-1013-4R BTL-P-1014-2R BTL-P-1012-4R BTL transducer and the processor/control must be connected using shielded cable. Shielding: Copper filament braided, 85 % coverage. Fig. 3-4: Magnet (optional) 4 Wiring 4.1 Cable axial and radial Cable length max. 400 m; Ø 6 to 8 mm. Longer lengths may be used if construction, shielding and routing are such that external noise fields will have no effect on signal integrity. Caution! False data will result from reversing the +Clk and Clk inputs. The cable shield must be grounded on the control side, i.e., connected to the protection ground. Pin assignments can be found in Table 4-1. Connections on the controller side may vary according to the controller and configuration used. To avoid coupled noise, avoid proximity to high-current lines when routing cable between transducer, controller and power supply. Inductive coupled noise from AC harmonics (e.g., from phase controls) are especially critical, against which the cable shield offers very little protection. BTL5-S1 +Clk Clk +Data Data GND +24 V YE PK GY GN BU BN Processor/ Controller Colors BTL5-S1... Interface signals YE yellow +Clk PK pink -Clk GY gray +Data GN green Data Supply voltage (external) BU blue GND BN brown +24 V WH white do not connect Fig. 4-1: BTL5-S1 -... with Processor/Controller, connection example Table 4-1: Wiring 6

5 Startup 5.1 Check connections Although the connections are polarity reversal protected, components can be damaged by improper connections and overvoltage. Before you apply power, check the connections carefully. 5.2 Turning on the system Note that the system may execute uncontrolled movements when first turned on or when the transducer is part of a closed-loop system whose parameters have not yet been set. Therefore make sure that no hazards could result from these situations. 5.3 Check output values After replacing or repairing a transducer, it is advisable to verify the values for the start and end position of the magnet in manual mode. If values other* than those present before the replacement or repair are found, a correction should be made. * Transducers are subject to modification or manufacturing tolerances. 5.4 Check functionality The functionality of the transducer system and all its associated components should be regularly checked and recorded. 5.5 Fault conditions When there is evidence that the transducer system is not operating properly, it should be taken out of service and guarded against unauthorized use. 6 Versions (indicated on part label) Supply voltage: 1 = DC 24 V Electr. connection, BTL5-S102-M0450-HB-FA05-C FA05: Teflon cable 5 m, axial F05: Teflon cable 5 m, radial Micropulse Linear Transducer SSI interface Rod Style, Mounting: C: For connection of cable guard system HB = metric thread M18 1.5 WB = Thread 3/4"-16UNF Nom. length (4digits): M = metric in mm Resolution: 2 = 5 µm 3 = 10 µm 4 = 20 µm 5 = 40 µm 6 = 100 µm 7 = 2 µm 8 = 50 µm Code: 24 bit 0 = binary, rising 1 = Gray, rising 2 = binary, falling 3 = Gray, falling 25 bit 6 = binary, rising 7 = Gray, rising 8 = binary, falling 9 = Gray, falling 6.1 Included in shipment Transducer with condensed guide 6.2 Available lengths Nominal stroke lengths of from 25 to 4000 mm are available for ideally sizing the transducer to the application. 7

7 Accessories (order separately) 7.1 Magnets Magnet BTL-P-1013-4R, BTL-P-1012-4R Dimensions Fig. 3-4 Weight approx. 10 g Housing anodized aluminum Operating temp. 40 C to +85 C included in shipment Spacer 8 mm Material POM (Polyoxymethylene) Magnet BTL-P-1014-2R Dimensions Fig. 3-4 Weight approx. 10 g Housing anodized aluminum Operating temp. 40 C to +85 C Magnet BTL-P-0814-GR-PAF Dimensions Fig. 3-4 Weight approx. 2 g Housing Polyamide bound ferrite Operating temp. 40 C to +85 C 7.2 Compatible devices Display: BDD-AM10-1-SSI display and limit controller with 2 relay outputs 7.3 Mounting nut BTL5...-HB... Mounting nut M18x1.5 BTL-A-FK01-E-M18x1.5 BTL5...-WB... Mounting nut 3/4"-16UNF BTL-A-FK01-E-3/4"-16UNF 8

8 Technical Data Typical values at DC 24 V, room temperature and BTL with nominal length of 500 mm. Ready for operation at once, full accuracy after warm-up. With magnet BTL-P-1013-4R, BTL-P-1014-2R or BTL-P-1012-4R: Resolution (LSB) depending on version: BTL5-S1 _2... 5 µm BTL5-S1 _3... 10 µm BTL5-S1 _4... 20 µm BTL5-S1 _5... 40 µm BTL5-S1 _6... 100 µm BTL5-S1 _7... 2 µm BTL5-S1 _8... 50 µm Non-linearity for resolution < 10 µm ± 30 µm for resolution > 10 µm ± 2 LSB Hysteresis < 1 LSB Repeatability < 2 LSB (resolution + hysteresis) Temperature coefficient < (6 µm + 5 ppm * nominal length)/k lag error 2.5 Frame Shock loading 100 g/6 ms per IEC 60068-2-27 1 Continuous shock 100 g/2 ms per IEC 60068-2-29 1 Vibration 12 g, 10 to 2000 Hz per IEC 60068-2-6 1 (take care to avoid inherent resonances of protective tube) Pressure up to 600 bar when installed in a hydraulic cylinder 1 Individual specifications as per Balluff factory standard 8.1 Dimensions, weights, ambient conditions Nominal length < 4000 mm Dimensions Fig. 3-1 Weight approx. 2 kg/m Housing Stainless steel Pressure tube Stainless steel 1.4571 Diameter 10.2 mm Wall thickness 2 mm E-modulus approx. 200 kn/mm 2 Mounting threads M18 1.5 or 3/4"-16UNF Operating temp. 40 C to +85 C Humidity < 90 %, non-dewing Protection rating per IEC 60529 with connector attached: cable version IP 68 (type tested at 5 bar / 48 h) IP69/K with connected cable guard system 8.2 Supply voltage (external) Regulated supply voltage BTL5-_1... 20 to 28 V DC Ripple < 0.5 Vpp Current draw < 90 ma Inrush < 3 A/0.5 ms Polarity reversal protection built-in Overvoltage protection Transzorb diodes Electric strength GND to housing 500 V DC 8.3 Control signals Interface RS 485/422 Clock input: +Clk, Clk (via optical coupler) Clock frequency max. 1000 khz Output data +Data, Data Position information 24 or 25 bit serial UL authorization File No. E227256 The CE Mark verifies that our products meet the requirements of EU Directive 2004/108/EC (EMC Directive) and the EMC Law. Testing in our EMC Laboratory, which is accredited by DATech for Testing Electromagnetic Compatibility, has confirmed that Balluff products meet the EMC requirements of the following Generic Standards: EN 61000-6-4 (emission) EN 61000-6-2 (noise immunity) 8.4 Connection to processor BTL5-...-FA05 with connecting cable, axial arrangement, 5 m long BTL5-...-F05 with connecting cable, radial arrangement, 5 m long Teflon cable -40 C to +200 C The clock frequency is a function of the cable length: Cable length Clock frequency < 25 m < 1000 khz < 50 m < 500 khz < 100 m < 400 khz < 200 m < 200 khz < 400 m < 100 khz Table 8-1: Clock frequency The following patents have been granted in connection with this product: US Patent 5 923 164 Apparatus and Method for Automatically Tuning the Gain of an Amplifier Emission tests: RF Emission EN 55011 Group 1, Class A+B Noise immunity tests: Static electricity (ESD) EN 61000-4-2 Severity level 3 Electromagnetic fields (RFI) EN 61000-4-3 Severity level 3 Fast transients (Burst) EN 61000-4-4 Severity level 3 Surge EN 61000-4-5 Severity level 2 Line-induced noise induced by high-frequency fields EN 61000-4-6 Severity level 3 Magnetic fields EN 61000-4-8 Severity level 4 No. 857 937-726 E 00.000000 Edition 0709; specifications subject to changes. 9