BTL5-P1 _-M -HB/WB-FA /F -C Micropulse Linear Transducer - Rod Style



Similar documents
BTL5-S1 -M -HB/WB-FA /F -C Micropulse Linear Transducer - Rod Style

PROFIBUS-DP BTL5-T1 -M/U -B/Z-S103. Technical Description User's Guide. english

D. PARAMETER SPECIFICATION Measured Variable: Displacement

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Redundancy Module QUINT-DIODE/40

How To Power A Schen

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Inductive sensor NI10-M18-Y1X-H1141

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Series 6000 Torque measured metal bellow coupling

Encoder WDGI 58H.

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Analog signal converters CC-E I/I Current / current isolators

Instruction Manual Differential Pressure Transmitter

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

User s Manual Inductive Analog Position Sensor BIL SmartSens No E Edition 0802

Cross-beam scanning system to detect slim objects. 100 mm in

BNI EIP Z009 IP67 Module, Unmanaged Switch

STRATO LED Drivers 70W, Single output

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Pressure transmitter For general industrial applications Model A-10

Description. Dimensions. Features. precision works better

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Electronic Pressure Switch EDS 3000

Mounting Instructions. Torque Transducer. A en

Telephone- and leased line modem for industrial applications TD-36

Electronic Pressure Switch EDS 300

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Rotary actuators Rotary wing drives Series RAK. Brochure

Three-phase monitoring relay CM-PFE

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Conductive Level Switch FK 2 Technical Data:

RM4TG20 three-phase network control relay RM4-T - range V

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

ABSOLUTE ROTARY ENCODER ETHERNET/IP

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Adjustment functions for both span and shift have been incorporated

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Operating Instructions for Plastic Flow Meter. Model: KSK

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

BOS 73K... BOS 74K...

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

MAGNETOSTICTIVE TRANSDUCER

Series 7500 Torque Sensor

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Proximity Switches RS (Reed Switch)

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

ACTUATOR LA37 PRODUCT DATA SHEET

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

LVDT. Inductive Position Transducer. SM Series. Key-Features:

TECHNICAL DATASHEET Incremental Encoder RI 58-H

Liquid Level Limit Switch liquiphant T FTL 20

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide

49 Series - Relay interface modules A. Features

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

QR12 (1.22 ) Diameter Optical Encoder

Digital display DA 48

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

DS 600. A contact free flux gate based current measurement sensor 600A rms

Digital input modules

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

Cable Plug acc. to DIN EN , Form A

R&S ZNC Vector Network Analyzer Specifications

Technical Data. Dimensions

Givare NC-SRS 280 och 880

Operating instructions

Magnetic proximity switches

48 SERIES Relay interface modules 10 A

Transcription:

User's Manual Balluff GmbH Schurwaldstraße 9 73765 Neuhausen a.d.f. Germany Phone +49 7158 173-0 Fax +49 7158 5010 balluff@balluff.de www.balluff.com 1

Contents 1 Safety Advisory... 2 1.1 Proper application... 2 1.2 Qualified personnel... 2 1.3 Use and inspection... 2 1.4 Scope... 2 2 Function and characteristics... 3 2.1 Characteristics... 3 2.2 Function... 3 3 Installation... 4 3.1 Mounting... 5 3.2 Transducer, Installation... 5 3.3 Magnets, Installation... 6 4 Wiring... 6 4.1 Cable axial and radial... 6 5 Startup... 7 5.1 Check connections... 7 5.2 Turning on the system... 7 5.3 Check output values... 7 5.4 Check functionality... 7 5.5 Fault conditions... 7 6 Versions (indicated on part label)... 7 6.1 Included in shipment... 7 6.2 Available lengths... 7 7 Accessories... 7 7.1 Magnets... 7 7.2 Mounting nut... 7 8 Technical Data... 8 8.1 Dimensions, weights, ambient conditions... 8 8.2 Supply voltage (external)... 8 8.3 Outputs... 8 8.4 Connection to processor... 8 1 Safety Advisory Read this manual before installing and operating the Micropulse Transducer. 1.1 Proper application The BTL5 Micropulse transducer is intended to be installed in a machine or system. Together with a controller (PLC) or a processor it comprises a position measuring system and may only be used for this purpose. Unauthorized modifications and non-permitted usage will result in the loss of warranty and liability claims. 1.2 Qualified personnel This guide is intended for specialized personnel who will perform the installation and setup of the system. 1.3 Use and inspection The relevant safety regulations must be followed when using the trans- ducer system. In particular, steps must be taken to ensure that should the transducer system become defective no hazards to persons or property can result. This includes the installation of additional safety limit switches, emergency shutoff switches and maintaining the permissible ambient conditions. 1.4 Scope This guide applies to the model BTL5-P1...HB/WB-... Micropulse transducer. An overview of the various models can be found in chapter 6 Versions (indicated on part label) on page 7. Note: For special versions, which are indicated by an -SA _ designation in the part number, other technical data may apply (affecting calibration, wiring, dimensions etc.). 2

2 Function and characteristics 2.1 Characteristics Micropulse transducers are characterized by: Very high resolution, repeatability, and linearity Absolute output signal Tough assembly Housing of stainless steel Wear- and maintenance-free measuring principle Insensitive to shock, vibration, contamination, and noise Pressure rated to 600 bar Teflon cable Capability of connecting cable guard systems Enclosure rating per IEC 60529: Cable version IP 68 (type tested at 5 bar / 48 h) IP69/K with connected cable guard system 2.2 Function The transducer contains a waveguide enclosed by an outer stainless steel rod. A magnet attached to the moving member of the machine or to the cylinder piston is moved over the rod and its position constantly updated. The magnet ring must remain within the measuring range. The magnet defines the measured position on the waveguide. An externally generated INIT pulse interacts with the magnetic field of the magnet to generate a magnetostrictive torsional wave in the waveguide which propagates at ultrasonic speed. The torsional wave arriving at the end of the waveguide is absorbed in the damping zone. The wave arriving at the beginning of the waveguide creates an electrical signal in the coil surrounding the waveguide. The propagation time of the wave is used to determine the position which is output as digital information. This takes place with high precision and repeatability within the measuring range indicated as the nominal stroke length. At the rod end is a damping zone, within which no reliable signal is available, but which may be entered by the magnet. The electrical connection between the transducer, the controller and the power supply is via a fixed cable. Dimensions for installing the Micropulse transducer: Fig. 3-1 Dimensions for installing the magnet: Fig. 3-4 3

3 Installation BTL5...HB/WB-...-C - axial M18 1.5 HB: 30-1mm WB: 2" -0.04" ➀ Magnet Nom. length = stroke ➁ Damping zone ➀ Ø 5 for Hookspanner Ø 58-62, tightening torque max. 100 Nm Mounting surface Thread size HB: M18 1.5 WB: 3/4"-16UNF Blind hole M4 4/ 6 deep ➀ unusable area ➁ not included BTL5...HB/WB-...-C - radial HB: 30-1mm WB: 2" -0.04" ➀ Magnet ➁ Nom. length = stroke Damping zone ➀ Blind hole M4 4/ 6 deep Mounting surface Fig. 3-1: Transducer BTL5-...HB/WB-..., Dimensions Important Installation Notes: The contact surface of the transducer must be completely contacted by the mounting surface. The O-ring supplied must make a perfect pressure seal, i.e. the bevel for the O-ring must be configured exactly as shown in Fig. 3-3. To achieve secure mounting, use the proper nut for the mounting thread. When tightening the transducer, do not exceed a tightening torque of 100 Nm. For horizontal mounting of transducer with stroke lengths greater than 500 mm, the pressure tube should be supported or attached at its end. When installing in a hydraulic cylinder, do not allow the magnet ring to rub against the pressure tube. The bore diameter in the piston and cylinder rod should be at least 13 mm. 4

3 Installation (cont.) 3.1 Mounting When possible, use non-magnetizable material for attaching the transducer and magnet ring. Fig. 3-2. When attaching the transducer to magnetizable materials, appropriate measures must be taken to protect against magnetic disturbances Fig. 3-2. Note the recommended distance of the transducer and cylinder from strong, external magnetic fields. non-magnetizable material ➀ - ➂ for magnetizable materials ➃ for non-magnetizable materials Fig. 3-2: Mounting a = Spacer made of non-magnetizable materials b = Magnet 3.2 Transducer, Installation The smallest permissible distance between magnet ring and rod mounting surface is shown in Fig. 3-1. The transducer has either a M18 1.5 thread or a 3/4"-16UNF thread for mounting. The sealing is carried cut with the O-ring supplied at the flange facing. Threaded hole M18 1.5 per ISO 6149 O-ring 15.4 2.1 Threaded hole 3/4"-16UNF per SAE J475 O-ring 15.3 2.4 Bevel for O-ring Threaded hole Fig. 3-3: Threaded hole for mounting the BTL with O-ring 5

3 Installation (cont.) 3.3 Magnets, Installation A magnet is required for each transducer. This must be ordered separately. Fig. 3-4. For mounting the magnet we recommend to use non-magnetizable material. Fig. 3-2. BTL-P-0814-GR-PAF BTL-P-1013-4R BTL-P-1014-2R BTL-P-1012-4R Fig. 3-4: Magnet (optional) 4 Wiring 4.1 Cable axial and radial Cable length max. 500 m; Ø 6 to 8 mm. Longer lengths may be used if construction, shielding and routing are such that external noise fields will have no effect on signal integrity. BTL5-P1-... INIT START/STOP INIT START/STOP GND +24 V High noise immunity on the line between the transducer and processor is provided by the differential line drivers used for the RS 485/422 interface. The differential signal is carried to the processor, which makes it available as analog or digital information for further processing. YE GY PK GN BU BN processor card or controller Fig. 4-1: BTL5-P1 -... with processor card/controller, wiring example 4 Wiring (cont.) Note the following when making electrical connections: System and control cabinet must be at the same ground potential. To ensure the electromagnetic compatibility (EMC) which Balluff warrants with the CE Mark, the following instructions must be strictly followed. BTL transducer and the processor/control must be connected using shielded cable. Shielding: Copper filament braided, 85 % coverage. The cable shield must be grounded on the control side, i.e., connected to the protection ground. Pin assignments can be found in Table 4-1. Connections on the controller side may vary according to the controller and configuration used. To avoid coupled noise, avoid proximity to high-current lines when routing cable between transducer, controller and power supply. Inductive coupled noise from AC harmonics (e.g., from phase controls) are especially critical, against which the cable shield offers very little protection. Control and data signals Cable BTL5-P1... YE yellow GY gray ➀ Unused leads can be tied to GND on the control side, but they must never be connected to the shield. Table 4-1: Wiring INIT START/STOP (2nd edge) PK pink INIT GN green START/STOP (2nd edge) Supply voltage (external) BU blue GND BN brown WH white +24 V not used ➀ 6

5 Startup 5.1 Check connections Although the connections are polarity reversal protected, components can be damaged by improper connections and overvoltage. Before you apply power, check the connections carefully. 5.2 Turning on the system Note that the system may execute uncontrolled movements when first turned on or when the transducer is part of a closed-loop system whose parameters have not yet been set. Therefore make sure that no hazards could result from these situations. 5.3 Check output values After replacing or repairing a transducer, it is advisable to verify the values for the start and end position of the magnet in manual mode. If values other* than those present before the replacement or repair are found, a correction should be made. * Transducers are subject to modification or manufacturing tolerances. 5.4 Check functionality The functionality of the transducer system and all its associated components should be regularly checked and recorded. 5.5 Fault conditions When there is evidence that the transducer system is not operating properly, it should be taken out of service and guarded against unauthorized use. 6 Versions (indicated on part label) Supply voltage: 1 = DC 24 V Electr. connection, FA05: Teflon cable 5 m, axial F05: Teflon cable 5 m, radial BTL5-P1-M0450-HB-FA05-C Micropulse Linear Transducer Rod Style, Mounting: Nom. length (4digits): C: For connection of cable guard system HB = metric thread M18x1.5 WB = Thread 3/4"-16UNF M = metric in mm Digital output signals: BTL5-P1... Start Stop 6.1 Included in shipment Transducer with condensed guide 6.2 Available lengths Nominal stroke lengths of from 25 to 4000 mm are available for ideally sizing the transducer to the application. 7 Accessories (order separately) 7.1 Magnets Magnet BTL-P-1013-4R, BTL-P-1012-4R Dimensions Fig. 3-4 Weight approx. 10 g Housing anodized aluminum Operating temp. 40 C to +85 C included in shipment Spacer 8 mm Material POM (Polyoxymethylene) Magnet BTL-P-1014-2R Dimensions Fig. 3-4 Weight approx. 10 g Housing anodized aluminum Operating temp. 40 C to +85 C Magnet BTL-P-0814-GR-PAF Dimensions Fig. 3-4 Weight approx. 2 g Housing Polyamide bound ferrite Operating temp. 40 C to +85 C 7.2 Mounting nut BTL5...-HB... Mounting nut M18x1.5 BTL-A-FK01-E-M18x1.5 BTL5...-WB... Mounting nut 3/4"-16UNF BTL-A-FK01-E-3/4"-16UNF 7

8 Technical Data Typical values at DC 24 V, room temperature and BTL with nominal length of 500 mm. Ready for operation at once, full accuracy after warm-up. With magnet BTL-P-1013-4R, BTL-P-1014-2R or BTL-P-1012-4R: Resolution < 2 µm Hysteresis < 4 µm Repeatability < 6 µm (resolution + hysteresis) System resolution is determined by the processor or external controller. Recommended sampling rate: Nominal length f Standard < 1000 mm 0.5 to 2 khz < 2000 mm 0.5 to 1 khz > 2000 mm 0.5 khz 8.2 Supply voltage (external) Regulated supply voltage BTL5-_1... 20 to 28 V DC Ripple < 0.5 Vpp Current draw < 90 ma (at 1 khz) Inrush < 3 A/0.5 ms Polarity reversal protection built-in Overvoltage protection Transzorb diodes Electric strength GND to housing 500 V DC Non-linearity: Nom. length < 500 mm > 500 mm ±100 µm ±0.02 % FS Temperature coefficient (6 µm + 5 ppm * nominal length)/k Shock loading 100 g/6 ms per IEC 60068-2-27 1 Continuous shock 100 g/2 ms per IEC 60068-2-29 1 Vibration 12 g, 10 bis 2000 Hz per IEC 60068-2-6 1 (take care to avoid inherent resonances of protective tube) Pressure up to 600 bar when installed in a hydraulic cylinder 1 Individual specifications as per Balluff factory standard 7.1 Dimensions, weights, ambient conditions Nominal length < 4000 mm Dimensions Fig. 3-1 Weight ca. 2 kg/m Housing Stainless steel Pressure tube Stainless steel 1.4571 diameter 10.2 mm wall thickness 2 mm e-modulus ca. 200 kn/mm 2 Mounting threads M18 1.5 or 3/4"-16UNF Operating temp. 40 C to +85 C Humidity < 90 %, non-dewing Protection rating per IEC 60529 with connector attached: cable version IP 68 (type tested at 5 bar / 48 h) IP69/K with connected cable guard system 8.3 Control signals INIT pulse Level +5 V RS 485/422 driver Length 1 µs (max. 3 µs) 8.4 Connection to processor BTL5-...-FA05 with connecting cable, axial arrangement, 5 m long BTL5-...-F05 with connecting cable, radial arrangement, 5 m long Teflon cable -40 C to +200 C UL authorization File No. E227256 The CE Mark verifies that our products meet the requirements of EU Directive 2004/108/EC (EMC Directive) and the EMC Law. Testing in our EMC Laboratory, which is accredited by DATech for Testing Electromagnetic Compatibility, has confirmed that Balluff products meet the EMC requirements of the following Generic Standards: EN 61000-6-4 (emission) EN 61000-6-2 (noise immunity) The following patents have been granted in connection with this product: US Patent 5 923 164 Apparatus and Method for Automatically Tuning the Gain of an Amplifier Emission tests: RF Emission EN 55011 Group 1, Class A+B Noise immunity tests: Static electricity (ESD) EN 61000-4-2 Severity level 3 Electromagnetic fields (RFI) EN 61000-4-3 Severity level 3 Fast transients (Burst) EN 61000-4-4 Severity level 3 Surge EN 61000-4-5 Severity level 2 Line-induced noise induced by high-frequency fields EN 61000-4-6 Severity level 3 Magnetic fields EN 61000-4-8 Severity level 4 No. 857 939-726 E 00.000000 Edition 0709; specifications subject to changes. 8